PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Multiple injection techniques for microfluidic sample handling.

This paper presents an experimental and numerical investigation into electrokinetic focusing flow injection for bioanalytical applications on 1 x N (i.e., 1 sample inlet port and N outlet ports) and M x N (i.e., M sample inlet ports and N outlet ports) microfluidic chips. A novel device is presented which integrates two important microfluidic phenomena, namely electrokinetic focusing and valveless flow switching within multiported microchannels. The study proposes a voltage control model which achieves electrokinetic focusing in a prefocusing sample injection system and which allows the volume of the sample to be controlled. Using the developed methods, the study shows how the sample may be prefocused electrokinetically into a narrow stream prior to being injected continuously into specified outlet ports. The microfluidic chips presented within this paper possess an exciting potential for use in a variety of techniques, including high-throughput chemical analysis, cell fusion, fraction collection, fast sample mixing, and many other applications within the micrototalanalysis systems field.

Automation↗

Microfluidic device for capillary electrochromatography-mass spectrometry.

A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.

Electrophoresis, Capillary↗

Zeta potential determination by streaming current modelization and measurement in electrophoretic microfluidic systems.

Electrophoresis in capillary and microfluidic systems, used in analytical chemistry to separate charged species, are quite sensitive to surface phenomena in terms of separation performances. In order to improve theses performances, new surface functionalization techniques are required. There is a need for methods to provide fast and accurate quantification about surface charges at liquid/solid interfaces. We present a fast, simple, and low-cost technique for the measurement of the zeta-potential, via the modelization and the measurement of streaming currents. Due to the small channel cross section in microfluidic devices, the streaming current modelization is easier than the streaming potential measurement. The modelization combines microfluidic simulations based on the Navier-Stokes equation and charge repartition simulations based on the Poisson-Boltzmann equation. This method has been validated with square and circular cross section shape fused-silica capillaries and can be easily transposed to any lab-on-chip microsystems.

Electrochemistry↗

Zeta potential of microfluidic substrates: 2. Data for polymers.

Zeta potential data are reviewed for a variety of polymeric microfluidic substrate materials. Many of these materials currently used for microchip fabrication have only recently been employed for generation of electroosmotic flow. Despite their recent history, polymeric microfluidic substrates are currently used extensively for microchip separations and other techniques, and understanding of the surface zeta potential is crucial for experimental design. This paper proposes the use of pC (the negative logarithm of the counterion concentration) as a useful normalization for the zeta potential on polymer substrates in contact with indifferent univalent counterions. Normalizing zeta by pC facilitates comparison of results from many investigators. The sparseness of available data for polymeric substrates prevents complete and rigorous justification for this normalization; however, it is consistent with double layer and adsorption theory. For buffers with indifferent univalent cations, normalization with the logarithm of the counterion concentration in general collapses data onto a single zeta/pC vs. pH curve, and (with the exception of PMMA) the repeatability of the data is quite encouraging. Normalization techniques should allow improved ability to predict zeta potential performance on microfluidic substrates and compare results observed with different parameters.

Electric Capacitance↗

Determination of inorganic ions using microfluidic devices.

The separation and detection of inorganic ions on microfluidic devices has received little attention since the 'lab-on-a-chip' concept has revolutionised the field of electrokinetically driven analysis. This review presents a summary and discussion of the published literature on inorganic analysis using microfluidic devices and includes sections on electromigration separation methods, namely isotachophoresis (ITP), capillary electrophoresis (CE), and hyphenated ITP-CE, together with a brief account of flow injection analysis. The review concludes with the authors' perspective on future directions for inorganic analysis on microfluidic devices.

Chemistry Techniques, Analytical↗

Microfluidic devices for the analysis of apoptosis.

Apoptosis is the outcome of a metabolic cascade that results in cell death in a controlled manner. Due to its important role in maintaining balance in organisms, in mechanisms of diseases, and tissue homeostasis, apoptosis is of great interest in the emerging fields of systems biology. Research into cell death regulation and efforts to model apoptosis processes have become powerful drivers for new technologies to acquire ever more comprehensive information from cells and cell populations. The microfluidic technology promises to integrate and miniaturize many bioanalytical processes, which offers an alternative platform for the analysis of apoptosis. This review aims to highlight the recent developments of microfluidic devices in measuring the hallmarks as well as the dynamic process of cellular apoptosis. The potential capability and an outlook of microfluidic devices for the study of apoptosis are addressed.

Animals↗

Electrospray interfacing of polymer microfluidics to MALDI-MS.

The off-line coupling of polymer microfluidics to MALDI-MS is presented using electrospray deposition. Using polycarbonate microfluidic chips with integrated hydrophobic membrane electrospray tips, peptides and proteins are deposited onto a stainless steel target followed by MALDI-MS analysis. Microchip electrospray deposition is found to yield excellent spatial control and homogeneity of deposited peptide spots, and significantly improved MALDI-MS spectral reproducibility compared to traditional target preparation methods. A detection limit of 3.5 fmol is demonstrated for angiotensin. Furthermore, multiple electrospray tips on a single chip provide the ability to simultaneously elute parallel sample streams onto a MALDI target for high-throughput multiplexed analysis. Using a three-element electrospray tip array with 150 microm spacing, the simultaneous deposition of bradykinin, fibrinopeptide, and angiotensin is achieved with no cross talk between deposited samples. In addition, in-line proteolytic digestion of intact proteins is successfully achieved during the electrospray process by binding trypsin within the electrospray membrane, eliminating the need for on-probe digestion prior to MALDI-MS. The technology offers promise for a range of microfluidic platforms designed for high-throughput multiplexed proteomic analyses in which simultaneous on-chip separations require an effective interface to MS.

Microfluidic Analytical Techniques↗

Gold nanoparticles for microfluidics-based biosensing of PCR products by hybridization-induced fluorescence quenching.

Colloidal gold nanoparticles were used to develop a simple microfluidics-based bioassay that is able to recognize and detect specific DNA sequences via conformational change-induced fluorescence quenching. In this method, a self-assembled monolayer of gold nanoparticles was fabricated on the channel wall of a microfluidic chip, and DNA probes were bonded to the monolayer via thiol groups at one end and a fluorophore dye was attached to the other end of the probe. The created construct is spontaneously assembled into a constrained arch-like conformation on the particle surface and, under which, the fluorescence of fluorophores is quenched by gold nanoparticles. Hybridization of target DNAs results in a conformational change of the construct and then restores the fluorescence, which serves as a sensing method for the target genes. The nanocomposite constructed on the glass surface was characterized by UV absorbance measurement and the quenching efficiency for different fluorophores was evaluated by Stern-Volmer studies. The applicability of proposed assay was first demonstrated by the use of a pair of synthesized complementary and noncomplementary DNA sequences. The method was further applied for the detection of the PCR product of dengue virus with the use of enterovirus as the negative control, and results indicate that the assay is specific for the target gene. Moreover, using this approach, dehybridization, hybridization, and detection of the target genes can be performed in situ on the same microfluidic channel. Thus, this method could be regarded as one-pot reaction and it holds great promises for clinical diagnostics.

Biosensing Techniques↗

Assessment of Joule heating and its effects on electroosmotic flow and electrophoretic transport of solutes in microfluidic channels.

Joule heating is inevitable when an electric field is applied across a conducting medium. It would impose limitations on the performance of electrokinetic microfluidic devices. This article presents a 3-D mathematical model for Joule heating and its effects on the EOF and electrophoretic transport of solutes in microfluidic channels. The governing equations were numerically solved using the finite-volume method. Experiments were carried out to investigate the Joule heating associated phenomena and to verify the numerical models. A rhodamine B-based thermometry technique was employed to measure the solution temperature distributions in microfluidic channels. The microparticle image velocimetry technique was used to measure the velocity profiles of EOF under the influence of Joule heating. The numerical solutions were compared with experimental results, and reasonable agreement was found. It is found that with the presence of Joule heating, the EOF velocity deviates from its normal "plug-like" profile. The numerical simulations show that Joule heating not only accelerates the sample transport but also distorts the shape of the sample band.

Electrophoresis↗

Sacrificial layer microfluidic device fabrication methods.

Over the past 15 years, research in the field of microfluidics has experienced rapid growth due to significant potential advantages such as low cost, short analysis times, and elimination of sources of contamination. Although etched and thermally bonded glass substrates have seen widespread use and offer solid performance, device fabrication still remains cumbersome. Recent advances in sacrificial layer microfabrication methods for microfluidics have overcome many disadvantages of conventional fabrication approaches. Phase-changing sacrificial layers have been implemented in making inexpensive and high-performance polymer microchips for electrophoretic analysis, protein focusing, and sample preconcentration. In addition, novel channel fabrication methods based on standard thin-film processes, which are readily integratable with microfabrication techniques used for electrical components, are being applied increasingly for the creation of microfluidic devices. These new sacrificial layer fabrication approaches will be instrumental in making low-cost and high-quality polymer microchips, and in interfacing electrical and fluidic systems on glass or semiconductor substrates.

Equipment Design↗

An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection.

This study presents an integrated microfluidic chip capable of performing DNA/RNA (deoxyribonucleic acid/ribonucleic acid) amplification, electrokinetic sample injection and separation, and on-line optical detection of nucleic acid products in an automatic mode. In the proposed device, DNA/RNA samples are first replicated using a micromachine-based PCR module or reverse transcription PCR (RT-PCR) module and then transported by a pneumatic micropump to a sample reservoir. The samples are subsequently driven electrokinetically into a microchannel, where they are separated electrophoretically and then detected optically by a buried optical fiber. The various modules of the integrated microfluidic chip are fabricated from cheap bio-compatible materials, such as PDMS, polymethylmethacrylate, and soda-lime glass. The functionality of the proposed device is demonstrated through its successful application to the DNA-based bacterial detection of Streptococcus pneumoniae and the RNA-based detection of Dengue-2 virus. It is shown that the low thermal inertia of the PCR/RT-PCR modules reduces the sample and reagent consumption and shortens the reaction time. With less human intervention, the subsequent DNA separation and detection could be performed in an automatic mode. The integrated microfluidic device proposed in this study represents a crucial contribution to the fields of molecular biology, genetic analysis, infectious disease detection, and other biomedical applications.

DNA↗

Integrated microfluidic devices with enhanced separation performance: application to phosphoproteome analyses of differentiated cell model systems.

This work reports on the application of a microfluidic device integrating nanoscale LC to nanoelectrospray MS (nano-LC-chip-MS) for the analysis of complex protein digests. Peak profile analyses of more than 700 peptide ions, reproducibly detected across replicate nano-LC-chip-MS runs (n = 5), indicated that the system provided RSD values of 0.24% on retention time, +/- 30 ppm on m/z measurement and +/- 30% variation on intensity over three orders of magnitude. RP adsorbant media with different alkyl chains and particle size packed in both trapping and separation channels were investigated to improve the chromatographic performance of this system. A two-fold improvement in chromatographic peak capacity was achieved using microfluidic devices comprising a 5 mircrom C3 trap with 2.5 microm C18 trap separation channel compared to the traditional 5 microm C18 stationary phase. Enhanced sample selectivity for the identification of phosphopeptides was obtained by combining immobilized metal affinity media prior to peptide separation on the RP microfluidic device. This system was evaluated in the context of differential phosphoproteome analyses to identify changes in signaling events and protein expression of human monocytes following the administration of phorbol ester.

Animals↗

DNA separation with low-viscosity sieving matrix on microfabricated polycarbonate microfluidic chips.

Microfluidic devices have been fabricated on polycarbonate (PC) substrates by use of a hot embossing method using a silicon master template. By adding auxiliary lines around the functional channel on the silicon master, its lifetime was significantly prolonged and the bonding strength of the PC cover plate to the microfluidic chip was greatly improved. More than 300 polycarbonate microfluidic chips have been replicated with the same silicon mold. CE separation of Phi X-174/HaeIII DNA restriction fragments, with high resolution efficiency and good reproducibility, was achieved on these devices using the low-viscosity sieving matrix HPMC-50. Temperature was found to have a significant effect on separation efficiency.

Bacteriophage phi X 174↗

Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays.

Microfluidics are emerging as a promising technology for miniaturizing biological assays for applications in diagnostics and research in life sciences because they enable the parallel analysis of multiple analytes with economy of samples and in short time. We have previously developed microfluidic networks for surface immunoassays where antibodies that are immobilized on one wall of a microchannel capture analytes flowing in the microchannel. This technology is capable of detecting analytes with picomolar sensitivity and from sub-microliter volume of sample within 45 min. This paper presents the theoretical modeling of these immunoassays where a finite difference algorithm is applied to delineate the role of the transport of analyte molecules in the microchannel (convection and diffusion), the kinetics of binding between the analyte and the capture antibodies, and the surface density of the capture antibody on the assay. The model shows that assays can be greatly optimized by varying the flow velocity of the solution of analyte in the microchannels. The model also shows how much the analyte-antibody binding constant and the surface density of the capture antibodies influence the performance of the assay. We then derive strategies to optimize assays toward maximal sensitivity, minimal sample volume requirement or fast performance, which we think will allow further development of microfluidic networks for immunoassay applications.

Antigen-Antibody Complex↗

Optimization of reporter cells for expression profiling in a microfluidic device.

The emergence of green fluorescence protein (GFP) technologies has enabled non-invasive monitoring of cell function and gene expression. GFP-based expression studies are typically performed in traditional single-dish or multi-well formats to monitor a small number of genes or conditions that do not lend well to scaling, high-throughput analysis, or single-cell measurements. We have recently developed a microfluidic device, the Living Cell Array (LCA), for monitoring GFP-based gene expression in a high-throughput manner. Here, we report the optimization of GFP reporter cell characteristics in this microfluidic device for gene expression profiling. A reporter cell line for the transcription factor NF-kappa B was generated and used as the model cell line. Reporter cells were seeded in the LCA and NF-kappa B activated by addition of the cytokine TNF-alpha . Our studies show that the fluorescence kinetics from the reporter cell line in response to both single and repeated TNF-alpha stimulation in the LCA is similar to that observed in standard tissue culture. In addition, our data also indicate that multiple expression waves can be reliably monitored from a small population of reporter cells. Using reporter cell line subcloning and cell cycle synchronization, we demonstrate that the kinetics and magnitude of induced fluorescence in the reporter cell lines can be further improved to maximize the fluorescence readout from reporter cell lines, thereby improving their applicability to live cell expression profiling. Our studies establish some of the important criteria to be considered when using reporter cell lines for dynamic expression profiling in microfluidic devices.

Cell Culture Techniques↗

A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate.

A microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The device consists of a SU-8 waveguide, microfluidic channels and grooves for the insertion of optic fibres. It was fabricated by one-step photolithography of SU-8 polymer resist. Different channel widths (50-300 microm) were tested in terms of detection sensitivity. A wide range of flow rates were applied to investigate the influence of flow rate on signal fluctuations. The separation between optical fibre sensor and microfluidic channel and the width of fluidic channel have been optimized to maximize the detection sensitivity. It was revealed that 250 microm of channel width is the optimum light path length for a compromise between detection sensitivity and interference of ambient light. The independence of detection signals on flow rates was demonstrated within the range of flow rate (0.5-5 ml/hr) tested. Compared with conventional lactate detection, the device is proved to have high accuracy, relatively low limit of detection (50 mg/L) and reasonably fast response time (100 sec). The fabrication of device is simple and low cost. The present work has provided some fundamental data for further system optimization to meet specific detection requirements.

Biosensing Techniques↗

Elucidating in vitro cell-cell interaction using a microfluidic coculture system.

This work presents a novel microfluidic coculture system that improves the accuracy of evaluating the interaction between cocultured cell types. A microfluidic coculture chip, fabricated by CO(2) laser direct-writing on polymethyl methacrylate (PMMA), was designed to separate two cell types using a microchannel, while permitting transfer of cellular media. The system has two up-stream wells and five down-stream wells. As an example, released inflammatory cytokines (e.g., interleukin-1 beta (IL-1 beta) and tumor necrosis factor-alpha (TNF-alpha)), activated in up-stream macrophages, flow through a microfluidic mixing system, generating linear concentration gradients in down-stream wells and inducing down-stream osteoblasts to release prostaglandin E2 (PGE2), a well-known bone resorption marker. Osteoblast viability was assessed by 3-[4, 5-dimethylthiazol-2-yl]-2, 5-diphenyltetrazolium bromide (MTT) assay. This novel coculture system can be applied to evaluate cell-cell interaction while physically separating interacting cells.

Cell Communication↗

Magnetic-based microfluidic platform for biomolecular separation.

A novel microfluidic platform for manipulation of micro/nano magnetic particles was designed, fabricated and tested for applications dealing with biomolecular separation. Recently, magnetic immunomagnetic cell separation has attracted a noticeable attention due to the high selectivity of such separation methods. Strong magnetic field gradients can be developed along the entire wire, and the miniaturized size of these current-carrying conductors strongly enhances the magnetic field gradient and therefore produces large, tunable and localized magnetic forces that can be applied on magnetic particles and confine them in very small spots. Further increases in the values of the generated magnetic field gradients can be achieved by employing miniaturized ferromagnetic structures (pillars) which can be magnetized by an external magnetic field or by micro-coils on the same chip. In this study, we demonstrate magnetic beads trapping, concentration, transportation and sensing in a liquid sample under continuous flow by employing high magnetic field gradients generated by novel multi-functional magnetic micro-devices. Each individual magnetic micro-device consists of the following components: 1. Cu micro-coils array embedded in the silicon substrate with high aspect ratio conductors for efficient magnetic field generation 2. Magnetic pillar(s) made of the magnetic alloy NiCoP for magnetic field focusing and magnetic field gradient enhancement. Each pillar is magnetized by its corresponding coil 3. Integrated sensing coil for magnetic beads detection 4. Microfluidic chamber containing all the previous components. Magnetic fields of about 0.1 T and field gradients of around 300 T/cm have been achieved, which allowed to develop a magnetic force of 3 x 10(-9) N on a magnetic particle with radius of 1 mum. This force is large enough to trap/move this particle as the required force to affect such particles in a liquid sample is on the order of approximately pN. Trapping rates of up to 80% were achieved. Furthermore, different micro-coil designs were realized which allowed various movement modes and with different step-sizes. These results demonstrate that such devices incorporated within a microfluidic system can provide significantly improved spatial resolution and force magnitude for quick, efficient and highly selective magnetic trapping, separation and transportation, and as such they are an excellent solution for miniaturized mu-total analysis systems.

Biopolymers↗