PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polystyrenes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Covalently Bound Antibody on Polystyrene Latex Beads: Formation, Stability, and Use in Analyses of White Blood Cell Populations.

CD4 or CD8 antibodies were covalently bound to latex beads by reaction of activated CD4 or CD8 monoclonal antibodies with 2-µm-diameter, 1,3-diaminopropane (DAP) coupled, polystyrene aldehyde/sulfate latex beads. Spectrophotometric analyses of the filtrates of the antibody-bead conjugation mixtures for unreacted antibody allowed construction of binding curves of antibody for the polystyrene bead surface and evaluation of binding constants for association of antibody with bead, ranging from 1.5x10(7) to 1.6x10(7) M(-1) for CD4 and CD8 antibodies. The reaction of the antibody thiol group with the activated maleimide group on the bead at pH 7.2-7.3 was complete within 10-15 min. The kinetics of CD4 or CD8 monoclonal antibody displacement from the surface of covalently conjugated antibody-polystyrene latex beads was followed as a function of temperature (5, 22, and 37 degrees C) and the nature of the final diluent for the antibody-coated beads by measuring the concentration of antibody in the filtrates of conjugated beads by an ELISA (enzyme-linked immunosorbent assay). The displacement reaction showed a pseudo-zero-order dependence of the rate, with constants, k(1), ranging from 0.65x10(-17) to 270x10(-17) M s(-1). The functionality of antibody-coated beads suspended in various media was also monitored in a biological cell assay with whole blood. The cell assay depends on forming a layer of beads around targeted lymphocytes to distinguish them from nontargeted lymphocytes by differences in dc or rf conductivity or median angle light scatter. Covalently bound CD4 and CD8 antibody beads stored in one set of media at 5, 22, and 37 degrees C over a period of 16 weeks showed excellent results in the STKS assay with various blood donors, which correlated well (correlation coefficients of 0.99 for CD4 data and 0.93 for CD8 data) with reference results obtained with fluorescent markers by flow cytometry. Covalently bound CD4/CD8 beads stored for 2 weeks in BSA buffer at 5-37 degrees C performed equally well in providing accurate values of the percentage of CD4- or CD8-positive cells in the total white blood cell population, whereas the same beads stored in the 47-50 degrees C range showed some failures in performance. Comparison with antibody concentrations in filtrates of adsorbed antibody-bead suspensions showed 2- to 10-fold greater amounts of free antibody at comparable elapsed time, media, and temperature conditions. A threshold of 1-2 µg/mL of free antibody was necessary before adverse effects on the biological cell assay were noticeable. Copyright 2001 Academic Press.

Journal Article↗

Glutathione depletion in isolated rat heaptocytes caused by styrene and the thermal degradation products of polystyrene.

Depletion of reduced glutathione (GSH) was induced in isolated rat hepatocytes incubated with styrene or exposed for 120 min to products from oxidative thermal degradation of polystyrene. The depletion depended on the concentrations of styrene and on the degradation temperature. Styrene (1 mM) or products from degradation of polystyrene at 200 degrees C (concentration of styrene in exposure atmosphere 0.7 ppm) had no detectable effect on glutathione levels in isolated hepatocytes. At higher degradation temperatures (250 degrees C and 300 degrees C, with styrene concentrations of 2.5 and 25 ppm, respectively) a rapid depletion was detected as well as with 3 mM styrene in incubation mixture. The latency of lactate dehydrogenase was affected neither by the polystyrene degradation products nor by the styrene added to the incubation mixture.

Animals↗

Immobilization of viral and mycoplasma antigens and of immunoglobulins on polystyrene surface for immunoassays.

The immobilization of purified influenza virus, rubella virus, crude nuclear cytomegalovirus antigen and of mycoplasma on polystyrene tubes was studied using radio-iodinated preparations. The antigen activities on tube surfaces were determined using sequentially specific human antibodies and alkaline phosphatase-conjugated anti-human IgG in an enzyme-immunoassay (EIA) reaction. In addition, immobilization of radio-iodinated human IgG, IgM, and IgA, serving as model proteins, was studied using the respective anti-immunoglobulin conjugates in EIA directly. Pretreatment of the surface with albumin and glutaraldehyde inhibited the adsorption and antigenicity of IgG. Increase of temperature and thus of speed of adsorption did not affect the fraction of antigen eluted during the test procedure. Only with IgG and IgA was it necessary to saturate the polystyrene surface in order to achieve maximal reactivity in EIA. With other antigens, maximal reactivity in EIA was obtained with amounts of protein much lower than the maximal amount that could be adsorbed per tube. IgM was found to have an exceptionally high affinity to polystyrene.

Antigens, Bacterial↗

Detection of immune complexes using a solid-phase C1q polystyrene ball assay.

A polystyrene ball C1q solid-phase assay (PSB C1q SPA) has been developed for quantitating immune complexes in human serum. While similar to the previously reported solid-phase C1q assays in principle, the use of polystyrene balls with a specular finish has resulted in an assay with significantly improved accuracy, sensitivity and reproducibility. The sensitivity of the assay based on the amount of AHGG bound per microgram C1q added was approximately 12-fold higher in the PSB assay compared to the polystyrene tube solid-phase C1q method. In order to correct for variable background contributions in different samples, values obtained with heat-inactivated C1q were subtracted from each experimental result. Reproducibility studies yielded a coefficient of variation (CV) of 10 and 4% in day-to-day assays using 25 microgram and 100 microgram AHGG/ml normal serum, respectively compared to 11--15% for the tube technique. Within run measurements gave a CV of 37 and 20% at the low and high levels of AHGG. Aggregated human gamma-globulin (AHGG) was used as a model immune complex and when chromatographed on Biogel A-15m yielded major fractions at greater than or equal to 15,000,000 and 150,000 daltons. Maximum binding of AHGG to PSB C1q occurred with aggregates greater than 15,000,000 daltons. Optimum binding of human albumin-anti-albumin complexes in the PSB C1q SPA occurred at a molar ratio of 1 : 1.5. The size distribution of this complex active in the assay determined by sucrose density gradients was 14--32 S with peaks at 21 and 27 S. A normal range of immune complexes was determined as 15 +/- 8 microgram AHGG equivalents (+/- 2 S.D., n = 65). Approximately 70% of rheumatoid arthritis, linear scleroderma, vasculitis, Sjögren's and glomerulonephritis and 40% of SLE patients were above 2 S.D. of normal. SLE patients demonstrated elevations in immune complexes only during periods of increased disease severity. The assay was a useful monitor of plasmapheresis in an SLE patient, showing decreases in immune complexes after each plasmapheresis. DNA did not interfere with AHGG binding whereas lipemia prevented detection of added AHGG.

Antigen-Antibody Complex↗

Aerosol size standards in the nanometer size range II. Narrow size distributions of polystyrene 3-11 nm in diameter.

A technique for generating charged aerosols of polystyrene (pSty) with narrow size distributions has been developed. It is based on electrospraying commercial narrow mass standards of pSty dissolved in l-methyl-2-pyrrolidone (NMP) seeded with the newly synthesized salt dimethyl ammonium formate. This salt imparts a much larger electrical conductivity than previously known NMP electrolytes, leading to higher quality sprays with greatly reduced attachment of impurities. Controlling the solute concentration enables forming polystyrene particles containing from one up to more than ten single polystyrene molecules, whereby 4 mass standards with molecular weights from 9200 up to 96,000 g/mol yield particles covering densely the diameter range from 3 to 11 nm. Combined mobility and mass measurement with a differential mobility analyzer and a mass spectrometer in tandem are carried out with a pSty sample 9200 amu in molecular weight. They fix directly the mass versus mobility relation near 9200 amu, and indirectly for the other standards and their clusters. The apparent particle density resulting from mobility versus mass data agrees with the bulk density of the polymer, indicating that the particles are dense and spherical. Although these standards have been studied only in gaseous suspension, their injection in liquids such as water where pSty is insoluble should keep them spherical.

Journal Article↗

A novel preparation route for platinum-polystyrene heterogeneous nanocomposite particles using alcohol-reduction method.

Platinum nanoparticles are homogeneously immobilized onto the polystyrene surface using alcohol-reduction method for the first time. Sulfonate groups were employed as a chemical protocol to make a binding between platinum nanoparticle and polystyrene surface. A large number of quasi-spherical platinum nanoparticles with a size of approximately 5 nm in diameter are formed and strongly attached to the polystyrene surface modified with sulfonate groups. The formation mechanism of composite materials was discussed briefly. The most distinguished features of this novel preparation route include simple operation, and absence of the toxic reducing agent. In addition, this novel preparation route can be extended to the preparation of other noble metal-polymer heterogeneous nanocomposites such as silver, gold, palladium, iridium and ruthenium.

Journal Article↗

Comparison of the isolation of adducts of 2'-deoxycytidine and 2'-deoxyguanosine with phenylglycidyl ether by high-performance liquid chromatography on a reversed-phase column and a polystyrene-divinylbenzene column.

2'-Deoxycitidine (dCyd) and 2'-deoxyguanosine (dGuo) were subjected to reaction with phenylglycidyl ether (PGE) in methanol in order to study the formation of the corresponding 2'-deoxynucleoside adducts. Separation methods were developed on analytical and semi-preparative scales using high-performance liquid chromatography with photodiode-array detection on a reversed-phase column and on a polystyrene-divinylbenzene column. The use of the latter column was prompted by decomposition of the preparatively isolated dGuo-PGE adducts on the reversed-phase column. The use of a polystyrene-divinylbenzene column solved this problem and also revealed the presence of one more peak in both the dCyd- and dGuo-PGE reaction mixtures. The adducts of dCyd and dGuo were isolated on preparative reversed-phase and polystyrene-divinylbenzene columns and characterized by UV, fast atom bombardment mass and 360 MHz 1H NMR spectrometry. The adducts of dCyd were the diastereomers of N-3-(2-hydroxy-3-phenoxypropyl)-2'-deoxycytidine and N4-(2-hydroxy-3-phenoxypropyl)-2'-deoxycytidine whereas those of dGuo were the two diastereomers of N-7-(2-hydroxy-3-phenoxypropyl)-2'-deoxyguanosine and a third peak which appeared to be mainly N2-(2-hydroxy-3-phenoxypropyl)-2'-deoxyguanosine.

Chromatography, High Pressure Liquid↗

Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separation of polymers. Comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in high-performance liquid chromatography of polystyrenes.

Gradient elution separations of polystyrene standards in a monolithic molded 50 x 8 mm I.D. poly(styrene-co-divinylbenzene) rod column and in 50 x 8 mm I.D. and 30 x 4.1 mm I.D. columns packed with porous and non-porous poly(styrene-co-divinylbenzene) beads has been carried out. All of these separation media differ in shape and porosity. Excellent separations of eight polystyrene standards were achieved with both the molded monolithic rod and porous beads at moderate flow-rates. However, the monolithic medium proved to be superior for high-speed separations using very steep gradients at a flow-rate of 20 ml/min. Three polystyrene standards were separated in the rod column within 4 s. The separation in the column packed with non-porous beads was poor at flow-rates of 2-8 ml/min, while higher flow-rates led to an unacceptably high back pressure.

Chromatography, High Pressure Liquid↗

Molar mass and molar mass distribution of polystyrene particle size standards.

Monodisperse polystyrene microspheres and nanospheres are often used as particle size standards for calibration of size-measuring instruments. They are potentially useful as the mass standards for particle mass spectrometry as well. We demonstrated in this work that it is possible to achieve high-precision mass determination for single polystyrene spheres using a quadrupole ion trap. We introduced the particles into the trap by laser-induced acoustic desorption and probed them with light scattering. Mass-to-charge ratios of the individual particles were determined from applied trap-driving frequencies, voltage amplitudes and the observed starlike oscillatory trajectories projected on the radial plane. Creation of one-electron differentials through charge-state changes by electron bombardment allowed determination for the absolute mass of a single trapped particle to a precision better than 0.1%. Both molar mass and molar mass distribution were deduced from a large number of measurements for NIST polystyrene particle size standards (SRMs 1690 and 1691). Our results are in excellent agreement with the size measurement for the 0.895-microm spheres (NIST SRM 1690), but a small discrepancy (4%) in number-average mass was found for the 0.269-microm spheres (NIST SRM 1691).

Journal Article↗

Ordered nanoporous polymers from polystyrene-polylactide block copolymers.

Nanoporous polystyrene monoliths were prepared from polystyrene-polylactide (PS-PLA) block copolymers that form hexagonally packed nanocylinders of PLA in a PS matrix. A morphology diagram was developed to determine the range in composition and molecular weight over which this morphology existed. Macroscopic alignment of these materials gave anisotropic monoliths that were subjected to mild degradation conditions leading to the chemical etching of the PLA. The resulting nanoporous monoliths consisted of a polystyrene matrix containing hexagonally close-packed, oriented, and continuous nanoscopic channels (pore size was tunable through synthesis or blending) lined with chemically accessible hydroxyl functional groups. Both the precursors and the porous materials were analyzed moleculary (size-exclusion chromatography and proton nuclear magnetic resonance spectroscopy) and structurally (small-angle X-ray scattering, scanning electron microscopy, and differential scanning calorimetry). In addition, the surface area and pore size distribution of the nanoporous monoliths were characterized (N2 adsorption measurements). These nanoporous materials have remarkable potential as hosts for nanomaterial synthesis, size-selective catalyst supports, and advanced separations.

Journal Article↗

PNIPAM-co-polystyrene core-shell microgels: structure, swelling behavior, and crystallization.

The present contribution presents the single-step preparation and characterization of poly(N-isopropyl acrylamide)-co-polystyrene core-shell microgels with varying polystyrene content. The swelling behavior of the particles is investigated using dynamic light scattering and differs significantly from the swelling behavior of poly(N-isopropyl acrylamide) homopolymer particles. The lower critical solution temperature is found to be shifted to lower temperatures upon increasing the polystyrene content of the particles. The core-shell structure of the particles is revealed by means of small angle neutron scattering (SANS) using the method of contrast variation. Additionally, the formation of mesoscopic crystals of these particles is investigated by means of scanning electron microscopy and also by SANS. The particles seem to have preferable properties with respect to crystallization compared to homopolymer microgels.

Journal Article↗

Coating noble metal nanocrystals (Ag, Au, Pd, and Pt) on polystyrene spheres via ultrasound irradiation.

The method of ultrasound irradiation is used for anchoring metallic nanocrystals (Ag, Au, Pd, and Pt) onto the surface of polystyrene spheres. In former studies, almost all the sonochemically prepared, coated metallic nanomaterials were formed as amorphous nanoparticles (Pol, V. G.; et al. Langmuir 2002, 18, 3352; Pol, V. G.; et al. Chem. Mater. 2003, 15, 1111; Zhong, Z. Y.; et al. Chem. Mater. 1999, 11 (9), 2350; Pol, V. G.; et al. Chem. Mater. 2003, 15, 1378), which were coated on various substrates (silica spheres, carbon spherules, titania, and alumina). On the other hand, the noble metal nanoparticles deposited on polystyrene spheres via ultrasound irradiation yielded nanocrystalline Ag, Au, Pd, and Pt particles on the surface of polystyrene as as-synthesized materials. The sonochemical mechanism is proposed based on chemical interactions between the particles.

Journal Article↗

Gold nanoshells on polystyrene cores for control of surface plasmon resonance.

A method is presented for synthesizing core-shell structures consisting of monodisperse polystyrene latex nanospheres as cores and gold nanoparticles as shells. Use of polystyrene spheres as the core in these structures is advantageous because they are readily available commercially in a wide range of sizes, and with dyes or other molecules doped into them. Gold nanoparticles, ranging in size from 1 to 20 nm, are prepared by reduction of a gold precursor with sodium citrate or tetrakis(hydroxymethyl)phosphonium chloride (THPC). Carboxylate-terminated polystyrene spheres are functionalized with 2-aminoethanethiol hydrochloride (AET), which forms a peptide bond with carboxylic acid groups on their surface, resulting in a thiol-terminated surface. Gold nanoparticles then bind to the thiol groups to provide up to about 50% coverage of the surface. These nanoparticles serve as seeds for growth of a continuous gold shell by reduction of additional gold precursor. The shell thickness and roughness can be controlled by the size of the nanoparticle seeds as well as by the process of their growth into a continuous shell. By variation of the relative sizes of the latex core and the thickness of the gold overlayer, the plasmon resonance of the nanoshell can be tuned to specific wavelengths across the visible and infrared range of the electromagnetic spectrum, for applications ranging from the construction of photonic crystals to biophotonics. The position and width of the plasmon resonance extinction peak are well-predicted by extended Mie scattering theory.

Journal Article↗

Grafting of amino functional monomer onto initiator-modified polystyrene particles.

Polystyrene nanoparticles with grafted chains of an amino functionalized polymer were prepared by a two-step polymerization process. In the first step, the polystyrene seed particles were synthesized by the conventional batch emulsion polymerization using terpolymer HAS (hydroperoxide monomer, acrylic acid, and styrene) as a surface-active initiator. The surface of the obtained particles contains carboxyl groups, which are responsible for the latex stability, and residual undecomposed hydroperoxide groups. Therefore, in the second step, an amino functional monomer was grafted onto the hydroperoxide modified polystyrene particles by a "grafting from" approach. X-ray photoelectron spectroscopy, NMR, and scanning electron microscopy were used to examine the surface of the amino functionalized particles. The amount of incorporated amino groups onto the particles was determined by fluorescenometric titration. In general, the number of amino groups on the particle surface increased with the increase of the functional monomer content in the reaction mixture. The incorporation of the functional monomer was also confirmed by electrophoretic measurements. Final particles possess amphoteric character due to the presence of amino and carboxyl groups on the surface. Adsorption of human immunoglobulins G onto the amino functionalized particles was studied as a function of pH and ionic strength. The covalent binding of human IgG was performed using the glutaraldehyde preactivation method. The immunoreactivity of the latex-IgG complex was examined by the latex agglutination test.

Journal Article↗

Close-packed colloidal crystalline arrays composed of polystyrene latex coated with titania nanosheets.

We have demonstrated that polystyrene latex coated with titania nanosheets can be fabricated into a close-packed colloidal crystalline array, and that these coated colloidal spheres can be used to control the peak position of optical stop bands through the coating. The titania-nanosheets-coated polystyrene latex was prepared by the layer-by-layer (LBL) assembly coating process, involving alternating lamination of cationic polyelectrolytes and anionic titania nanosheets on monodisperse polystyrene latex particles. The Bragg diffraction peak of the colloidal crystalline array shifted to longer wavelengths with the coating of titania nanosheets. This red shift was caused by an increase in refractive index upon coating, as revealed by angle-resolved reflection spectra measurements. The current work suggests new possibilities for the creation of advanced colloidal crystals having tunable optical properties from tailored colloidal spheres.

Journal Article↗

Polystyrene-supported dicyclohexylphenylphosphine adducts of amine- and phosphite-based palladacycles in the Suzuki coupling of aryl chlorides.

The polystyrene-immobilised palladacyclic complexes [Pd(TFA)(kappa2-N,C-C6H4CH2NMe2){P(C6H4-4-PS)Cy2}] and [PdCl(kappa2-P,C-{P(OC6H2-2,4-tBu2)(OC6H3-2,4-tBu2)2}{P(C6H4-4-PS)Cy2}](PS = polystyrene) and the homogeneous analogues [Pd(TFA)(kappa2-N,C-C6H4CH2NMe2)(PPhCy2)] and PdCl(kappa2-P,C-{P(OC6H2-2,4-tBu2)(OC6H3-2,4-tBu2)2}(PPhCy2)] were synthesised and characterised. The X-ray structure of one of the homogeneous analogues, [Pd(TFA)(kappa2-N,C-C6H4CH2NMe2)(PPhCy2)] was determined. All the complexes have been tested and show good activity in the Suzuki coupling of aryl chloride substrates. While the polystyrene-immobilised complexes are not recyclable, they are easily extracted and show low levels of palladium leaching.

Journal Article↗

Physical and chemical changes in polystyrene during electron irradiation using EELS in the TEM: contribution of the dielectric function.

We have performed electron energy-loss spectroscopy analysis of polystyrene in the analytical transmission electron microscope in order to evaluate the possibility of obtaining both chemical and dielectric information on the polymer at the submicrometre scale. Irradiation has also been studied, particularly the influence of the specimen temperature on the kinetics of degradation. The main results show that polystyrene is resistant to electron beam with a critical dose of about 104 C m-2 at 127 K. Spectra could be acquired with doses less than this critical dose. We were thus able to propose an identification of the different chemical bonds of carbon (including the C-H bond), in agreement with previous X-ray absorption near-edge structure experiments. The chemical changes in polystyrene due to severe irradiation damage are also visible in the carbon K-edge near-edge structure. At the same time, we calculated the dielectric function from the low-loss part of the spectra. Interestingly, this part of the spectrum is the most sensitive to irradiation, since great changes can be seen during exposure. Lastly, we propose a degradation process, in agreement with all these results.

Journal Article↗

Variability of the influence of physicochemical factors affecting bacterial adhesion to polystyrene substrata.

The role of electrostatic and hydrophobic interactions and solid and liquid surface tensions in the adhesion of four bacterial species (Pseudomonas fluorescens, Enterobacter cloacae, Chromobacterium sp., and Flexibacter sp.) to hydrophobic polystyrene petri dishes and to more hydrophilic polystyrene tissue culture dishes was investigated. The effect of electrostatic interactions was investigated by determining the effects of different electrolyte solutions on attachment to and of different electrolyte and pH solutions on detachment from the polystyrene substrate. The significance of solid and liquid surface tensions and hydrophobic interactions was investigated by measuring the effects of different surfactants (including a concentration series of dimethyl sulfoxide) on adhesion and detachment. Adhesion varied with bacterial species, substratum, and electrolyte type and concentration, with no apparent correlation between adhesion and electrolyte valence or concentration. The influence of different pH and detergent solutions on bacterial detachment also varied with species, substratum, pH, and detergent type; however, the greatest degree of detachment of all strains from the surfaces was produced by detergent treatment. The results suggest that adhesion cannot be attributed to any one type of adhesive interaction. There was some evidence for both electrostatic and hydrophobic interactions, but neither interaction could wholly account for the data.

Journal Article↗