Development of a device for rapid diagnosis of Down's syndrome.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The present-day problems in tuberculosis control are associated with a difficulty in detecting Mycobacterium tuberculosis (MBT) in due time and in determining its drug sensitivity by conventional microbiological assays. The determination of the drug sensitivity of MBT takes much time from 2 weeks to 3 months, which fails to initiate and perform specific therapy timely. Molecular genetic techniques, including biochip analysis, yield results in 24-48 hours, which solves the problem of choosing and initiating adequate antibacterial therapy in the shortest possible time after tuberculosis is diagnosed. To assess the situation associated with the prevalence of rifampicin-resistant tuberculosis, by using the biochip analysis, the authors have examined 501 patients with tuberculosis who live in the Kyrghyz Republic. Drug resistance has been found in 40.3% of the examinees. At the same time, their primary and secondary drug resistance is 25.7 and 61.8%, respectively. In tuberculosis patients living in Kyrghyzstan, rifampicin resistance of MBT is more frequently due to mutations in 531 (59.2%), 526 (20.8%), and 516 (8.0%) codons in the rpoB gene.
Explore the source record for details and available documents.
New-generation battery-powered products are required to provide increasingly greater performance. This article examines technology solutions and design techniques that can be employed to achieve ultralow-power medical devices.
Explore the source record for details and available documents.
This paper introduces the new research achievement and progress of electro-physiology in olfaction and gustation. Classical implements such as patch-clamp or glass pipette are not appropriate in the dynamic detection of cellular signal transportation. In view of this, we have analyzed the feasibilities and challenges of olfactory or gustatory cell-based biosensors such as field effect transistor (FET) and light addressable potentiometric sensor (LAPS). Finally we present the research work carried our in out lab and a future prospective on the development in this field.
OBJECTIVE: To investigate the expression of gene BRG1 in prostatic intraepithelial neoplasia and adenocarcinoma, and the relationship between gene BRG1 expression and the clinicopathological features of prostate carcinoma. METHODS: Gene BRG1 expression was evaluated in 37 cases of human prostate carcinoma, 13 human prostatic intraepithelial neoplasia (PIN) and 14 human benign prostatic hyperplasia (BPH) by using immunohistochemistry (EnVision method) and tissue microarray. RESULTS: The positive rates of BRG1 protein were 81.08% (30/37), 38.46% (5/13) and 14.28% (2/14) in prostate carcinoma, PIN and BPH, respectively, significantly higher in the first group than in the latter two (P < 0.05). There was no statistically significant difference in BRG1 gene expression either between PIN and BPH (P > 0.05) or between the groups of the moderate differentiation (the Gleason histologic grading: 5-7) and the lower one (the Gleason histologic grading: 8-10) (P > 0.05). CONCLUSION: BRG1 may play an important role in the development of prostate carcinoma. Tissue microarray technology, with the advantages of high throughput, conciseness, rapidity, high efficiency, low cost, and nice reproducibility, has significant practical value and broad application prospects in pathology.
Parallel two-phase laminar flow, which is formed when two solutions flow in microchannels, has been developed and has advanced unique research in the area of microchip analysis. In two-phase laminar flow, channel size has a significant effect on the efficiency of chemical reactions. However, the sizes of microchannels vary greatly in many studies. In this paper, we report on the effect of microchannel size on chemical reactions on a microchip. Aspect ratio is defined as the ratio of depth to width of a microchannel. Five microchips with different aspect ratios (from 0.50 to 2.00) were fabricated by mechanical machining. The reaction of nitrous acid and Saltzman reagent was carried out on these microchips and the absorbance was measured on-line in a capillary tube, which was attached to the outlet on the microchip. The results showed that the color reaction occurred more efficiently as the aspect ratio increased. This result is expected to be useful when determining the size of microchannels.
An ultrasensitive and nonlabeled detection method of nonfluorescent molecules on a microchip was developed by realizing a thermal lens microscope (TLM) with a 266-nm UV pulsed laser as an excitation light source (UV-TLM). Pulsed laser sources have advantages over continuous-wave laser sources in more compact size and better wavelength tuning, which are important for microchip-based analytical systems. Their disadvantage is difficulty in applying a lock-in amplifier due to the high (>10(4)) duty ratio of pulse oscillation. To overcome this problem, we realized a quasi-continuous-wave excitation by modulating the pulse trains at approximately 1 kHz and detecting the synchronous signal with a lock-in amplifier. The optimum pulse repetition frequency was obtained at 80 kHz, which was reasonable considering thermal equilibrium time. Furthermore, a permissible flow velocity in the range of 6.6-19.8 mm/s was found to avoid sensitivity decrease due to photochemical reactions and thermal energy dissipation. Under these conditions, we detected adenine aqueous solutions on a fused-silica microchip without labeling and obtained a sensitivity that was 350 times higher than that in a spectrophotometric method. The sensitivity was enough for detection on a microchip with an optical path length that was 2-3 orders shorter than that in conventional cuvettes. Finally, the UV-TLM method was applied to liquid chromatography detection. Fluorene and pyrene were separated in a microcolumn and detected in a capillary (50-microm inner diameter) with 150 times higher sensitivity than a spectrophotometric method. Our method provides highly sensitive and widely applicable detections for various analytical procedures and chemical syntheses on microchips.
This paper describes an indium tin oxide (ITO) electrode-based Ru(bpy)3(2+) electrochemiluminecence (ECL) detector for a microchip capillary electrophoresis (CE). The microchip CE-ECL system described in this article consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate with an ITO electrode fabricated by a photolithographic method. The PDMS layer was reversibly bound to the ITO electrode plate, which greatly simplified the alignment of the separation channel with the working electrode and enhanced the photon-capturing efficiency. In our study, the high separation electric field had no significant influence on the ECL detector, and decouplers for isolating the separation electric field were not needed in the microchip CE-ECL system. The ITO electrodes employed in the experiments displayed good durability and stability in the analytical procedures. Proline was selected to perform the microchip device with a limit of detection of 1.2 microM (S/N = 3) and a linear range from 5 to 600 microM.
Micro miniaturization of analytical procedures is having significant impact on diagnostic testing, and will enable highly complex clinical testing to be miniaturized and permit testing to move from the central laboratory into non-laboratory settings. The diverse range of micro analytical devices includes microchips, gene chips, bioelectronic chips. They have been applied to several clinically important assays (e.g., PCR, immunoassay). The main advantages of the new devices are integration of multiple steps in complex analytical procedures, diversity of application, sub-microliter consumption of reagents and sample, and portability. These devices form the basis of new and smaller analyzers (e.g., capillary electrophoresis) and may ultimately be used in even smaller devices useful in decentralized testing (lab-on-a-chip, personal laboratories). The impact of microchips on healthcare costs could be significant via timely intervention and monitoring, combined with improved treatments (e.g., microchip-based pharmacogenomic tests). Empowerment of health consumers to perform self-testing is limited, but microchips could accelerate this process and so produce a level of self-awareness of biochemical and genetic information hitherto unimaginable. The next level of miniaturization is the nanochip (nanometer-sized features) and the technological foundation for these futuristic devices is discernable in nanotubes and self-assembling molecular structures.
A membrane-based desalting step integrated in a MS microchip is presented: drugs, peptides and proteins are adsorbed on a hydrophobic poly(vinylidene difluoride) membrane, which allows the washing out of salts. The integration with microfluidics permits a controlled elution of analytes from the membrane and their direct mass spectrometric analysis by electrospray ionisation MS. The desalting process is demonstrated with picomole amounts of propanolol, insulin and cytochrome c. Moreover, this stop-and-go desalting process is tolerant to high concentrations of urea, and to the presence of reductants such as dithiothreitol. This particular feature allowed the chemical tagging of cysteines in beta-lactoglobulin A with iodoacetamide. Finally, the integration of chemical tagging, on-chip desalting and MS microchip paves the way for the development of high-throughput analytical procedure for structural proteomics.
A silica-based solid-phase extraction system suitable for incorporation into a microchip platform (nu-total analytical system; nu-TAS) would find utility in a variety of genetic analysis protocols, including DNA sequencing. The extraction procedure utilized is based on adsorption of the DNA onto bare silica. The procedure involves three steps: (i) DNA adsorption in the presence of a chaotropic salt, (ii) removal of contaminants with an alcohol/water solution, and (iii) elution of the adsorbed DNA in a small volume of buffer suitable for polymerase chain reaction (PCR) amplification. Multiple approaches for incorporation of this protocol into a microchip were examined with regard to extraction efficiency, reproducibility, stability, and the potential to provide PCR-amplifiable DNA. These included packing microchannels with silica beads only, generating a continuous silica network via sol-gel chemistry, and combinations of these. The optimal approach was found to involve immobilizing silica beads packed into the channel using a sol-gel network. This method allowed for successful extraction and elution of nanogram quantities of DNA in less than 25 min, with the DNA obtained in the elution buffer fraction. Evaluation of the eluted DNA indicated that it was of suitable quality for subsequent amplification by PCR.
White blood cells are isolated from whole blood in silicon-glass 4.5-microliter microchips containing a series of 3.5-micron feature-sized 'weir-type' filters, formed by an etched silicon dam spanning the flow chamber. Genomic DNA targets, e.g., dystrophin gene, can be directly amplified using the polymerase chain reaction (PCR) from the white cells isolated on the filters. This dual function microchip provides a means to simplify nucleic acid analyses by integrating in a single device two key steps in the analytical procedure, namely, cell isolation and PCR.
Microfluidic devices integrating membrane-based sample preparation with electrophoretic separation are demonstrated. These multilayer devices consist of 10 nm pore diameter membranes sandwiched between two layers of PDMS substrates with embedded microchannels. Because of the membrane isolation, material exchange between two fluidic layers can be precisely controlled by applied voltages. More importantly, since only small molecules can pass through the nanopores, the integrated membrane can serve as a filter or a concentrator prior to microchip electrophoresis under different design and operation modes. As a filter, they can be used for separation and selective injection of small analytes from sample matrix. This has been effectively applied in rapid determination of reduced glutathione in human plasma and red blood cells without any off-chip deproteinization procedure. Alternatively, in the concentrator mode, they can be used for online purification and preconcentration of macromolecules, which was illustrated by removing primers and preconcentrating the product DNA from a PCR product mixture.
Microfabricated devices enable rapid separations of a variety of clinically significant analytes, including DNA, proteins, and amino acids. However, absorbance detection has been difficult to achieve on these devices, prohibiting analysis of nonfluorophore-bearing or nonfluorescently tagged analytes. An alternative detection technique exploiting indirect fluorescence has been adapted to the electrophoretic microchip to provide fast analysis of amino acids, bypassing the need for absorbance detection or fluorescence derivitization procedures. Nineteen of the standard amino acids could be detected with an average detection limit of 32.9 microM (approximately 1.6 amol). Despite the fact that the detection sensitivity was lower than that achievable by labeling the amino acids with fluorescein isothiocyanate (approximately 1 nM), circumventing sample preparation and the difficulties inherent with tagging complex samples make this technique attractive for a variety of assays where sensitivity is not critical. To demonstrate the applicability to real sample matrixes, the analysis of urine with elevated amino acid levels is used as a model system where the elevated levels are indicative of a variety of pathologies including amino acid metabolism disorders and kidney malfunction. The minimal sample handling and rapid separations achievable by employing indirect detection on microchips provides the potential for high-throughput applications for certain amino acid analyses.
A method of electrochemically cleaning noble metal electrodes is presented and characterized for electrophoresis microchips with electrochemical detection. First, the loss of sensitivity due to electrode fouling by serotonin is characterized as a function of injection number and analyte concentration. Signal attenuation is observed to be greater at high concentrations (100 microM) and negligible at very low concentrations (approximately 1 microM). Next, an electrochemical treatment procedure is optimized to yield sensitive and reproducible amperometric detection of the highly adsorptive compounds, serotonin and histamine. Thus, the performance of the electrode is reproducibly regenerated following as much as a approximately 99% reduction in surface activity. Utilizing the optimized three-level waveform, derived from that used for pulsed amperometric detection, detection limits as low as 78 nM and 17 microM have been obtained for serotonin and histamine, respectively. In the case of serotonin, this represents the lowest detection limit for a neurotransmitter by microchip electrophoresis with amperometric detection and the first report of amperometric detection of histamine detection at an unmodified platinum electrode. Repeated use of the electrode and application of electrochemical treatment did not appear to measurably affect the noise, longevity, metal adhesion, or physical appearance of the electrode.
An improved fabrication of poly(methyl methacrylate) (PMMA)-based capillary electrophoresis microchips has been demonstrated. The microchannel structures on PMMA substrates were generated by one-step hot embossing procedure using a stainless steel template. Hundreds of patterned PMMA substrates have been successfully obtained using the single metal template. Sequent microchannel enclosure with high yield up to 90% was accomplished by a vacuum-assisted thermal bonding method. The results of profilometric scanning of separated substrates showed the dimensions of the channels were well preserved during the bonding process. Finally, analytical functionalities of these PMMA microchips were demonstrated by performing fast electrophoretic separations and high sensitive end-column amperometric detections of dopamine and catechol. The entire fabrication methodology may also be useful for preparation of other thermoplastic microfluidic systems.