PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Absorbable Implants”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

In vitro and in vivo testing of bioabsorbable antibiotic containing bone filler for osteomyelitis treatment.

The use of local antibiotics from a biodegradable implant is appealing concept for treatment of chronic osteomyelitis. Our aim was to develop a new drug delivery system based on controlled ciprofloxacin release from poly(D/L-lactide). Cylindrical composite pellets (1.0 x 0.9 mm) were manufactured from bioabsorbable poly(D/L-lactide) matrix and ciprofloxacin (7.4 wt %). In vitro studies were carried out to delineate the release profile of the antibiotic and to verify its antimicrobial activity by means of MIC testing. A long-term study in rabbits was performed to validate the release of ciprofloxacin from the composite in vivo. Therapeutic level of ciprofloxacin (>2 microg/mL) was maintained between 60 and 300 days and the concentration remained below the potentially detrimental level of 20 microg/mL in vitro. The released ciprofloxacin had retained its antimicrobial properties against common pathogens. In an exploratory long-term in vivo study with three rabbits, ciprofloxacin could not be detected from the serum after moderate filling (160 mg) of the tibia (follow-up 168 days), whereas after high dosing (a total dose of 1,000 mg in both tibias) ciprofloxacin was found temporarily at low serum concentrations (14-34 ng/mL) during the follow-up of 300 days. The bone concentrations of ciprofloxacin could be measured in all samples at 168 and 300 days. The tested copolylactide matrix seems to be a promising option in selection of resorbable carriers for sustained release of antibiotics, but the composite needs modifications to promote ciprofloxacin release during the first 60 days of implantation.

Absorbable Implants↗

[Biodegradable cage. Osteointegration in spondylodesis of the sheep cervical spine].

Bioabsorbable implants are commonplace in knee and shoulder surgery. Bioabsorbable poly(l-lactide-co-D,L-lactide) (PLDLLA) cage devices have potential benefits over autologous tricortical iliac crest bone graft and metallic cages for cervical spine interbody fusion. The purpose of this study was to compare interbody fusion of an autologous tricortical iliac crest bone graft with that of a bioabsorbable cage using a sheep cervical spine interbody fusion model. This study was designed to determine differences in (1) the ability to preserve postoperative distraction, (2) biomechanical stability, and (3) histological characteristics of intervertebral bone matrix formation. Sixteen full-grown Merino sheep underwent C3/4 discectomy and fusion. After 12 weeks, there was no significant difference between the results with the bioabsorbable PLDLLA cages and tricortical bone grafts. The cage also did not show advanced interbody fusion but did, however, show large osteolysis, which allows skepticism regarding the value of this bioabsorbable implant.

Absorbable Implants↗

A comparative radiological assessment of polylactide pins over 3 years in vivo.

Biodegradable polylactide implants allow secure fixation of osteochondral fractures with minimal adverse effects. The goal of this prospective, randomized animal study was to show whether osteoconductive effects can be achieved through the development of poly-L/DL(70/30)lactide composite implants with 10% beta-tricalcium phosphate, and whether degradation can be positively influenced and adverse effects minimized using such implants. An additional goal was to clarify which radiological procedure is most suitable to observe the course of follow-up. Thirtysix medial femoral condyle osteotomies of sheep were fixed with either 3 poly-L/DL-lactide pins or 3 composite pins, and the pin canal widths were measured with conventional radiographs, with CT, MRI, and histologically after 3, 18, and 36 months. All fractures healed completely without displacement or clinically relevant complications. The pin canals dilated secondary to pin degradation at the 12th month, and then decreased in size later. At 36 months, the pins had microscopically disappeared, and the canals were filled with bone or scar tissue. There were no statistically significant differences between the pin-types. Poly-L/DL-lactide pins and composite C-pins are suitable for secure fixation of small osteochondral fractures. Osteoconductive effects of biocompatibility or osseous integration relating to composite development were not evident. Conventional radiography and computer tomography were suitable techniques for observation of pin canals. Due to frequently observed artifact, MRI was not suitable to observe the course of the implants.

Absorbable Implants↗

Coralline bone graft substitutes.

Coralline porous ceramics are biocompatible and osteoconductive implants. They have proven to be effective as bone graft substitutes in large animal models and in humans. Bone and supporting soft tissue grow into and throughout their porosity if the implant is placed in direct apposition to viable bone and the interfaces are stabilized. The bone within the implant remodels in response to Wolff's law. Both the implant properties (chemistry and porosity) and the biologic environment modulate the rate of implant resorption. Composite technology with resorbable polymers can improve the mechanical properties of these ceramics.

Absorbable Implants↗

Vancomycin encapsulation in biodegradable poly(epsilon-caprolactone) microparticles for bone implantation. Influence of the formulation process on size, drug loading, in vitro release and cytocompatibility.

Vancomycin encapsulation in biodegradable poly(epsilon-caprolactone) microparticles (200 microm mean diameter) was most efficient with a simple emulsion technique that dispersed 122.5 mg/g of polymer. Scanning electron micrographs showed smooth or pitted particles. Dissolution studies were correlated with microparticle morphology, indicating higher release with pitted particles when vancomycin was encapsulated in a dissolved state. The cytocompatibility of these poly(epsilon-caprolactone) microparticles was demonstrated by a direct contact cytotoxic assay. This material can be considered as an efficient drug delivery system for bone implantation.

Absorbable Implants↗

The effects of guided bone regeneration and grafting on implants placed into immediate extraction sockets. An experimental study in dogs.

Guided bone regeneration (gbr) for the treatment of insufficient bone volume around implants can be performed using membranes with or without grafting materials (i.e., autogenous, allogenous, xenogenous, or alloplastic grafts). A possible way to evaluate the quality of implant osseointegration is the torque necessary to remove implants from their bony housing. The aim of this study was to compare the torques necessary to remove dental implants from implant beds reconstructed with different bone substitutes and GBR or GBR alone in 6 adult mongrel dogs. All mandibular premolars were extracted and 3 extraction sockets on each side were enlarged using a trephine bur. A 13 mm titanium screw-type dental implant (3.75 mm diameter) was placed in each enlarged extraction socket so that only the apical 3 to 4 mm were engaged in bone. The 3 defects were then randomly treated with either 1) canine demineralized freeze-dried bone allograft (DFDBA) plus GBR using an expanded polytetrafluoroethylene membrane (DFDBA+GTAM); 2) bioabsorbable hydroxyapatite and GBR (HA+GTAM); or 3) GBR (GTAM alone). After 6 months, the torque to remove the implants was measured in 4 animals and analyzed using ANOVA. There were no statistically significant differences between the 3 groups (GTAM alone: 46.37+/-16.41 Ncm; HA+GTAM: 46.00+/-16.59 Ncm; DFDBA+ GTAM: 52.15+/-29.24 Ncm). In addition, the influence of early removal of barriers on the torque values was evaluated with the t-test. Comparing exposed versus retained membranes by treatment modality, the only statistically significant difference was found in the DFDBA+GTAM group. When the torque values of all implants with exposed and retrieved membranes were compared to all those with retained membranes a significant difference could be detected. Histologic sections were prepared from the 2 dogs not included in the removal torque testing. In the histometric analysis the GTAM alone group showed a mean mineralized bone-to-implant-contact of 27.1%, the DFDBA+GTAM group of 34.6%, and the HA+GTAM of 39.3%. The mineralized bone-to-implant-contact of the HA+GTAM group was significantly higher than that of the GTAM alone group. In addition, the mineralized bone-to-implant-contact was divided into an apical and coronal part using the apical seventh thread as the dividing landmark. In the apical region, there was no significant difference between the groups regarding mineralized bone-to-implant-contact. In the coronal part the mineralized bone-to-implant-contact of the GTAM alone group was significantly lower compared to the other 2 groups. Within the limits of this investigation, it can be concluded that the type of grafting material will not influence torque removal values, but that early membrane exposure and removal will negatively influence the torque measurements. The combination of GBR with a bone substitute increased the mineralized bone-to-implant contact.

Absorbable Implants↗

Porous polyethylene implant for cranioplasty and skull base reconstruction.

OBJECT: Cranial reconstruction after skull base surgery is important for restoration of function and cosmesis. The authors describe their experience with the Medpor porous polyethylene implant for cosmetic cranioplasty and reconstruction after skull base surgery. METHODS: Medpor, a biocompatible implant, is flexible and can be contoured to facilitate surgical reconstruction of small to medium (< 8 cm) convexity or cranial base defects resulting from a variety of skull base approaches. This method provides similar cosmetic results to standard alloplast cranioplasty while decreasing operating time. The porous nature of the material allows ingrowth of soft tissue and bone to increase implant strength and decrease the risk of infection. This material can also be used safely in reconstruction of the cranium and skull base adjacent to the paranasal sinuses. CONCLUSIONS: The authors have used the Medpor porous polyethylene implant in 611 standard cranial and skull base procedures and have achieved excellent cosmetic results and no implant-related complications.

Absorbable Implants↗

Comparison of the efficacy and longevity of nonpenetrating glaucoma surgery with and without a new, nonabsorbable hydrophilic implant.

BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.

Absorbable Implants↗

125I vicryl suture implants as a surgical adjuvant in cancer of the head and neck.

Sixty-four intraoperative 125I seed implants using absorbable suture (Vicryl) carriers were performed in 53 patients with head and neck cancers at Stanford between 1975 and 1980. In previously untreated patients, local control in the implanted volume or in all head and neck sites was obtained in 79 and 71%, respectively. Five of these patients (40%) remained NED. Of 34 patients with recurrent carcinomas, local control was obtained in the implant volume in 20 (59%), while 38% had no recurrence post-implantation in any head and neck site. The incidence of complications is correlated with 125I radiation doses, total millicuries inserted, seed strength used, and tissue volume implanted for both untreated patients and those with local recurrences. Guidelines for the optimal use of the above 4 parameters are also presented. We conclude that 125I seed Vicryl intraoperative suture implants are an effective surgical adjuvant in the treatment of advanced, previously untreated or recurrent head and neck cancers.

Brachytherapy↗

[Resorbable rods and screws of polyglycolide in stabilizing malleolar fractures. A clinical study of 600 patients].

Absorbable internal fracture fixation implants have been in large-scale clinical use since 1984. The main advantage of these devices is that no subsequent operation for implant removal is required. In this study the results obtained in a series of 600 patients with displaced malleolar fractures who were operated on over a 6-year period (1985-1990) using rods or screws made of polyglycolide were analysed. Rod fixation was used in 63% and screw fixation in 37% of the patients. Recovery was uneventful in 91.5%. Bacterial wound infection occurred in 1.2% and failure of fixation necessitating reoperation in 0.8% (5 patients). In 4 of these 5 patients a refixation procedure with AO devices was performed. In one elderly patient with failed fixation talocrural arthrodesis had to be done. A sterile inflammatory foreign-body reaction complicated the course in 6.5%. The incidence of these reactions was higher during the early years of the study, when the implants contained an aromatic quinone dye, than later, when stain-free implants were used. The foreign-body reactions were transient and did not significantly influence the ultimate results of treatment. During the 6-year period the use of absorbable implants has made it possible for resources corresponding to several hundred hardware removal procedures to be used for other purposes.

Adolescent↗

Application of the lithium and magnesium initiators for the synthesis of glycolide, lactide, and epsilon-caprolactone copolymers biocompatible with brain tissue.

The subject of this work is new method of the synthesis of biodegradable copolymers compatible with brain tissue. Copolymerization of glycolide with lactide was conducted in solution or in bulk in the presence of LiBu, LiAcac, MgBu(2), Mg(acac)(2) as initiators. In all cases, copolymers with molecular weight of 20000-40000 were obtained, which enables to use them as drug carriers. During the reactions of copolymer chain growth, the intermolecular transesterification occurs, changing the distribution of comonomeric units in copolymer chain. Magnesium initiators showed a lower contribution to transesterification in comparison with lithium and calcium compounds. The copolymerization of glycolide with epsilon-caprolactone using magnesium compounds as initiators was also described. The random glycolide/epsilon-caprolactone copolymer (10/90) obtained with MgBu(2) was used in in vivo study in the forms of microspheres and foils. Complete degradation of microspheres during 6 weeks was observed after the implantation to brain tissue. All implanted copolymers are compatible with brain tissue.

Absorbable Implants↗

Fabrication of microstructures in photosensitive biodegradable polymers for tissue engineering applications.

Combining the MEMS technology and biology requirements for tissue engineering, the fabrication processes of microstructured chambers and microchannels made in biodegradable photosensitive polymers are presented. The fabrication processes, based on softlithography are very fast and flexible. Various single and multistepwise microstructures could be achieved using the biodegradable polymers. Microstructures down to 50microm, which are suitable for liver reconstructs, could be fabricated. As the pCLLA acrylate photosensitive polymer has interesting property for implantable bioreactors, that is, its softness, we examined the ability of various mammalian cells to grow and spread on it. With Hep G2 cells, human umbilical blood vessel endothelial cells (HUVEC), 3T3-L1 mouse fibroblasts, static cultures could be successfully performed on single stepwise microstructures. Then, by using this photosensitive biodegradable polymer, a microstructure with simple fluidic channels is fabricated and a perfusion experiment could be carried out. Both cell cultures and perfusion experiments suggested the possibility to use the present photosensitive polymer as microfluidic supports for biodegradable bioreactors for implantation applications.

3T3-L1 Cells↗

Bone formation and resorption of highly purified beta-tricalcium phosphate in the rat femoral condyle.

The aim of this study was to examine the chronological histology associated with highly purified beta-tricalcium phosphate (beta-TCP) implanted in the rat femoral condyle. Specimens were harvested on days 4, 7, 14, 28 and 56 after implantation, and were analyzed by tartrate-resistant acid phosphatase (TRAP) staining, immunohistochemistry of the ED1 protein as a marker of the phagocyte system, and in situ hybridization with digoxigenin-labeled alpha1 chain of type I procollagen (COL1A1), osteopontin and osteocalcin. beta-TCP was resorbed in a chronological manner. Although new bone was not observed on day 4, fibroblast-like cells around beta-TCP were positive for COL1A1 and osteopontin mRNA. New bone formation presented after day 7. In the double-staining for OPN and ED1 on day 7, most cells around beta-TCP were positive for either osteopontin mRNA or ED1 protein. However, there were some doubly positive multinucleated cells, suggesting that they belonged to the mononuclear phagocyte system. After day 28, the implanted region was replaced with bone marrow. Multinucleated TRAP-positive and ED1-positive cells which adhered to beta-TCP at all stages seemed to be osteoclasts and they continuously resorbed beta-TCP. beta-TCP has a good biocompatibility since both bioresorption and bone formation started at an early stage after implantation.

Absorbable Implants↗

Repair of long intercalated rib defects using porous beta-tricalcium phosphate cylinders containing recombinant human bone morphogenetic protein-2 in dogs.

A new method to repair rib defects with biomaterials containing recombinant human bone morphogenetic protein-2 (rhBMP-2) is presented in this report. We had reported previously the successful regeneration of bony rib defects by placing a short chain of small beta-tricalcium phosphate (beta-TCP) cylinders on the intact periosteum. The multi-cylinder implants were ineffective in promoting rib repair when the periosteum was absent. By adding rhBMP-2 to the beta-TCP cylinders, we were able to promote rib bone regeneration in the presence or absence of the periosteum. The osteogenic capacity of the rhBMP-2/beta-TCP composite implant and the time required to complete regeneration were evaluated in a canine model. An 8cm long section of rib bone, including the periosteum, was removed and replaced with a chain of the rhBMP-2/beta-TCP cylinders. At 6 weeks after implantation, the ribs were restored to their original configuration and mechanical strength. The multi-cylinder beta-TCP implants were degraded and replaced by new bone in 12 weeks. This new degradable bone-inducing implant material has significant clinical potential for rib repair.

Absorbable Implants↗

Sustained release of bovine serum albumin using implantable wafers prepared by MPEG-PLGA diblock copolymers.

MPEG-PLGA diblock copolymers, consisting of methoxy polyethylene glycol (MPEG) and poly(L-lactic-co-glycolic acid) (PLGA), were synthesized by ring-opening polymerization of L-lactide and glycolide in the presence of MPEG as an initiator. Implantable wafers, using diblock copolymers as a drug carrier, were fabricated by direct compression method after freeze milling of the diblock copolymers and bovine serum albumin-fluorescein isothiocyanate (BSA-FITC) as a model protein drug. The wafers prepared with MPEG-PLGA diblock copolymers exhibited initial burst in the release of BSA. The BSA release profiles from the wafers depended on MPEG-PLGA diblock copolymer compositions. The in vitro release of the BSA also correlated with the degradation rate of the PLGA part in the diblock polymers. The wafers prepared from diblock copolymers with an increased MPEG segment showed the more structural metamorphosis of crack form due to higher water absorption of MPEG inside the wafer, and induced faster BSA release. The wafers prepared by using MPEG-PLGA diblock copolymers in the presence of small intestinal submucosa (SIS) as a drug carrier additive exhibited controlled BSA release profiles, although the wafers exhibited release patterns with a lag time at the initial stage as the MPEG segment in diblock copolymer compositions increased. Thus, we confirmed that the MPEG-PLGA diblock copolymers could be used as a protein delivery carrier in implantable wafer form.

Absorbable Implants↗

Biologically engineered protein-graft-poly(ethylene glycol) hydrogels: a cell adhesive and plasmin-degradable biosynthetic material for tissue repair.

To address the need for bioactive materials toward clinical applications in wound healing and tissue regeneration, an artificial protein was created by recombinant DNA methods and modified by grafting of poly(ethylene glycol) diacrylate. Subsequent photopolymerization of the acrylate-containing precursors yielded protein-graft-poly(ethylene glycol) hydrogels. The artificial protein contained repeating amino acid sequences based on fibrinogen and anti-thrombin III, comprising an RGD integrin-binding motif, two plasmin degradation sites, and a heparin-binding site. Two-dimensional adhesion studies showed that the artificial protein had specific integrin-binding capability based on the RGD motif contained in its fibrinogen-based sequence. Furthermore, heparin bound strongly to the protein's anti-thrombin III-based region. Protein-graft-poly(ethylene glycol) hydrogels were plasmin degradable, had Young's moduli up to 3.5 kPa, and supported three-dimensional outgrowth of human fibroblasts. Cell attachment in three dimensions resulted from specific cell-surface integrin binding to the material's RGD sequence. Hydrogel penetration by cells involved serine-protease mediated matrix degradation in temporal and spatial synchrony with cellular outgrowth. Protein-graft-poly(ethylene glycol) hydrogels represent a new and versatile class of biomimetic hybrid materials that hold clinical promise in serving as implants to promote wound healing and tissue regeneration.

Absorbable Implants↗

Treatment of complete acromioclavicular dislocation: present indications and surgical technique with biodegradable cords.

We report a retrospective study of 48 patients with complete acromioclavicular dislocation (Tossy III). All patients (38 male; 10 female) with an average age of 33.4 years underwent surgery including PDS-augmentation. More than half of the injuries were caused by sport accidents. There were no complications during surgery. 87% of the patients were free of complaints and subjectively very satisfied with the surgical results. By radiological examination we diagnosed a subluxation of the clavicula in 25% of the cases and arthrosis in 17% of the cases. Assessment of subjective complaints, the clinical examination, and the radiological diagnostic according to the Taft Score (0-12 points) resulted in an average value of 10.2 points. The surgical intervention using PDS-cord augmentation in cases of complete acromioclavicular separation is a safe and economic method with a low complication rate. Advantages are possible early-functional treatment, no risk of movement of implants, and avoidance of metal removal.

Absorbable Implants↗