PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Read depth”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

The effect of ankle oedema on bone ultrasound assessment at the heel.

Relatively inexpensive, portable bone ultrasound systems are of particular relevance to disabled or elderly subjects, who may have problems with access to other forms of densitometry. The effects of local soft tissues on ultrasound measurements are poorly understood and, as ankle oedema is common in such subjects, we examined its consequences for bone ultrasound readings at the heel. Eleven elderly subjects (mean age 81 years) with below-knee pitting oedema were assessed using a direct-contact bone ultrasound system (CUBA Clinical). We made a total of 16 series of readings, 6 unilateral and 5 bilateral. In each series an initial reading was followed by repeated pressure over the measurement site to disperse oedema; subsequent readings were thus subject to a progressively lessening degree of local oedema, until a steady state was eventually reached in which no further oedema could be displaced. Heel width fell by a mean of 6.3 mm between initial and steady-state readings; consistent with the clinical appearance of moderate oedema, pitting to a mean depth of only 3.15 mm. Measurements in the presence of oedema were compared with those after its elimination, and oedema was shown to cause a mean reduction of 23.9 m/s in velocity of sound (VOS) and of 5.5 dB/MHz in broadband ultrasound attenuation (BUA). Both changes were equivalent to a fall by a quarter of one standard deviation of the reference range, and were significant at p < 0.05 on paired t-test. As the severity of oedema will vary through the day, and from day to day, measurement protocols for bone ultrasound should pay attention to the confounding effects of oedema.

Aged↗

Light microscopic depth measurements of thick sections.

Measurements of the thickness of a thick histological section or the depth of an object within the section, can be made most easily by reading differences in the setting of the fine focus knob of a compound light microscope. Two corrections must be made to such measurements: (1) when using a dry objective, a factor of 1.5 for the index of refraction of the specimen, and (2) a correction for the calibration of the fine focus itself. In addition, several precautions should be taken to minimize errors in the readings.

Histological Techniques↗

IOLSTAT--a program for comprehensive intraocular lens equation comparison with statistical analysis.

A computer program that will simultaneously solve five of the major intraocular lens (IOL) equations predicting the primary implant power required for emmetropia or ametropia is presented. The program can, alternatively, predict the degree of ametropia given the power of an IOL. The resultant predictions are analyzed using weighted and unweighted statistics, predicting a mean and a standard deviation. The results are displayed in a table which lists the prediction and the percent deviation from the weighted mean for each equation. The program features automatic averaging of keratometer readings, ultrasound axial length corrections, and an algorithm for estimating postoperative anterior chamber depth.

Algorithms↗

Laparoscopic lymph node dissection using ultrasonically activated shears: comparison with electrosurgery.

PURPOSE: To assess and compare perioperative parameters in two groups of patients treated by different laparoscopic techniques of lymph node dissection (LND) for gynecologic cancer. PATIENTS AND METHODS: Between April 1996 and March 2001, 59 consecutive women with microinvasive cervical cancer (N = 5) or clinical stage I endometrial cancer (N = 54) underwent laparoscopic LND during a primary staging procedure using an electrosurgery (ELC) or ultrasonic (US) operative technique. The two groups were compared for perioperative outcomes. Differences between the two groups were determined by the Wilcoxon's rank-sum test. RESULTS: Laparoscopic LND and other staging procedures were completed successfully in 58 women (98.3%). There were no statistically significant differences between the groups with regard to perioperative outcomes (operation time, time for LND, blood loss, hospital stay, complications), but there was a significant difference (P = 0.0008) in the number of lymph nodes harvested: a mean of 13.7 in the ELC group and 17.5 in the US group. The pathologists found that the reading of histology slides was easier after US dissections because of the greater depth of thermal injury in the lymphatic tissue in ELC group. CONCLUSION: The US operative technique ensures efficient coagulation, cutting, dissection, and grasping for laparoscopic LND in patients with cervical and endometrial cancer.

Adult↗

Comparison of 6-month results of implantation of the 1CU accommodative intraocular lens with conventional intraocular lenses.

OBJECTIVE: To evaluate the clinical results of implantation of the new 1CU accommodative intraocular lens (IOL) in cataract patients and to compare results with those of conventional IOLs. DESIGN: Nonrandomized comparative trial. PARTICIPANTS: Twenty eyes of 20 patients (mean age = 65.8+/-13.3 years) in the 1CU group and 20 eyes of 20 patients (mean age = 67.4+/-11.6 years) in the control group. METHODS: All patients underwent phacoemulsification and IOL implantation. The 1CU accommodative lens was used in 20 eyes, and conventional IOLs (polymethyl methacrylate, hydrophilic or hydrophobic acrylate) were used in the control group. Patients were observed prospectively, and 6-month data were analyzed. MAIN OUTCOME MEASURES: Accommodative ranges determined by 3 different methods (near point, defocusing, and retinoscopy). Secondary outcome measures were (1) increase of anterior chamber depth after topical application of 1% cyclopentolate eyedrops and (2) distance-corrected near visual acuity with Birkhäuser reading charts at 35 cm. RESULTS: We observed a higher accommodative range with all 3 methods (mean = 1.83+/-0.49 vs. 1.16+/-0.27 diopters [D] [near point], 1.85+/-0.43 vs. 0.64+/-0.21 D [defocusing], and 0.98+/-0.55 vs. 0.17+/-0.22 D [retinoscopy]), a larger increase of anterior chamber depth after cyclopentolate eyedrops (mean = 0.42+/-0.18 vs. 0.11+/-0.06 mm), and better distance-corrected near visual acuity (median = 0.4 vs. 0.2) in the 1CU group relative to the control group. All differences between the 2 groups were statistically highly significant (P<0.001). CONCLUSIONS: In the present study, the 1CU accommodative IOL showed increased accommodative range and better near visual acuity than a control group with conventional IOLs. Further research is necessary to confirm these results in masked, randomized, prospective studies and to confirm further the accommodative power of this group of new IOLs.

Accommodation, Ocular↗

Polymerization depths of contemporary light-curing units using microhardness.

PURPOSE: This research investigated composite depths of cure using a variety of light-curing units and exposure protocols. MATERIALS AND METHODS: Composite (Herculite XRV, shade A2, Kerr, Orange, California) was exposed in opaque compules to conventional quartz tungsten halogen (QTH) units, soft-start units, high-intensity QTH and plasma arc (PAC) curing lights, and one argon laser. Cured compules were sonicated to remove uncured composite and were sectioned and polished along the long axis to expose cured composite. Knoop hardness was measured 0.5 mm from the irradiated, top surface and then at 1.0 mm and in 1.0-mm increments until reliable readings could no longer be obtained. Hardness values were compared by analysis of variance at similar depths within a specific curing-light classification, using the hardness of the standard 40-second conventional QTH exposure as comparison (Dunnett's t-test). Depth of cure was defined as the deepest hardness value found equivalent to that at 0.5-mm depth for a specific curing light and scenario. RESULTS: Conventional QTH lights provided similar hardness profiles. At 2-mm depth, use of a different unit or curing tip made no difference in hardness compared with the standard. At this depth, soft-start (pulse-delay and step-cure) methods yielded hardness similar to that of the standard. High-intensity QTH lights provided similar hardness at 2-mm depth in 10 seconds to that of the standard 40-second exposure. Plasma arc exposure for less than 10 seconds produced inferior hardness compared with the standard. A 10-second PAC and a 5-second laser exposure gave hardness at 2-mm depth equivalent to that of the 40-second standard. Depth of cure for almost all curing scenarios was not greater than 2 mm. CLINICAL SIGNIFICANCE: Similar-type conventional QTH lights with different tip diameter (8 and 12 mm) provide similar composite cure characteristics. Soft-start techniques provide similar cure profiles to those achieved with conventional QTH technique when used according to manufacturer's recommendations. High-intensity QTH units and the argon laser can reduce exposure time while providing composite with similar hardness to that of conventional QTH curing. Plasma arc exposure should be at least of 10 seconds duration to provide hardness equivalent to that achieved with conventional 40-second QTH exposure. Even with consideration of high-intensity curing units, composite increments should still be no greater than 2 mm to provide homogeneous hardness.

Analysis of Variance↗

Rapid depth dose determination by a computer-controlled dosimetry system.

A comprehensive depth dose measuring system controlled by a small computer has been designed to enable full depth dose information for a linear accelerator to be obtained within one day. An ionization microchamber is moved rapidly under computer control in a horizontal plane to preselected points within a water phantom by two stepping motors to a spatial resolution of 0-025 mm. The ionization current pulses are converted to DC voltages by an interface providing complete charge integration and yet having a rapid response to drastic changes in dose level. These are fed to the computer for analysis and subsequent conversion to depth dose data. The chamber path follows a preselected fan-shaped grid after automatic determination of the X-ray beam central axis. The combination of rapid chamber motion with halts for charge integration and computer sampling has resulted in fast data acquisition independent of measurement response times. This information, which is stored on disc, can be directly read by a treatment planning program. The overall accuracy of measurement lies within 0-5% of the true depth dose at any point. Central axis and transverse profiles can be assessed at the time of measurement through visualization on the computer storage oscilloscope.

Computers↗

Informed consent and decision-making: patients' experiences of the process of recruitment to phases I and II anti-cancer drug trials.

This paper presents an examination of the process of recruitment in cancer clinical trials. This research was undertaken as part of a larger study which sought to assess the psychosocial impact of participation in phases I and II anti-cancer drug trials from the patient's perspective. Through a combination of in-depth interviews with 55 patients who were offered participation in a clinical trial, and reading ease assessments of the written information they were given, patients' experiences of recruitment to the trial and their perceptions of the informed consent process were obtained. The results indicate that patients decisions may be influenced by the way information was presented to them verbally and that the written information was difficult for them to understand. This aspect of the research identified the powerful influence of the verbal consultation when seeking consent for trial involvement, the lack of understanding patients had of what they were taking part in and the need to address the readability of the written information with which they are provided.

Adult↗

Preconception genetic counseling.

The purpose of this chapter has not been to be all-inclusive, but to raise awareness of the benefits of preconception consultation in the prevention of birth defects. If there is to be a significant decrease in the incidence of congenital malformations, it will come only by intervention that occurs prior to organogenesis, and that opportunity is lost by the first prenatal visit. For the practitioner interested in a more in-depth analysis of the subject of preconception counseling, the two books listed as supplementary reading provide a wealth of information essential to the care of the patient planning a pregnancy.

Congenital Abnormalities↗

WHOLE GENOME TARGETED ENRICHMENT AND SEQUENCING OF HUMAN-INFECTING CRYPTOSPORIDIUM spp.

Cryptosporidium spp. are protozoan parasites that cause severe illness in vulnerable human populations. Obtaining pure Cryptosporidium DNA from clinical and environmental samples is challenging because the oocysts shed in contaminated feces are limited in quantity, difficult to purify efficiently, may derive from multiple species, and yield limited DNA (<40 fg/oocyst). Here, we develop and validate a set of 100,000 RNA baits (CryptoCap_100k) based on six human-infecting Cryptosporidium spp. (C. cuniculus, C. hominis, C. meleagridis, C. parvum, C. tyzzeri, and C. viatorum) to enrich Cryptosporidium spp. DNA from a wide array of samples. We demonstrate that CryptoCap_100k increases the percentage of reads mapping to target Cryptosporidium references in a wide variety of scenarios, increasing the depth and breadth of genome coverage, facilitating increased accuracy of detecting and analyzing species within a given sample, while simultaneously decreasing costs, thereby opening new opportunities to understand the complex biology of these important pathogens.

Journal Article↗

Construction of a model eye and its applications.

Construction details are given of a model eye, based on the Bennett and Rabbetts schematic eye. It incorporates a cornea, lens, and spherical fundus. Distilled water filled the anterior and vitreous chambers. By means of a micrometer screw, the vitreous chamber depth can be precisely varied to produce axial ametropia from +11 to -17 D. Readings taken over the greater part of this range with a Topcon Autorefractor RM-A6500 were found to be repeatable and reproducible within +/- 0.25 D. The model eye was used to investigate the relationship between the actual size of a fundus feature and its photographic image in two different fundus cameras. With a Zeiss Oberkochen camera of telecentric design the magnification was found to remain constant whatever the degree of axial ametropia, whereas with a Carl Zeiss Jena camera the magnification varied linearly with ametropia. A technique developed by Littmann for determining the actual size of a retinal feature when using a fundus camera of telecentric design is discussed briefly.

Eye↗

[Polarity effects of commercial plane-parallel ionization chamber in therapeutic electron dosimetry-Results with C-134A ionization chamber.].

Plane-parallel ionization chambers that exhibit polar effects with low energy electron beams are recommended for therapeutic electron dosimetry. In this study, the polarity effects of a C-134A ionization chamber, a major commercially available plane-parallel ionization chamber in Japan, were characterized as a function of mean energy at various depths. Polarity effects were measured at representative depths along depth dose curves of nominal 4, 6, 9, 12 and 15 MeV electron beams, and were compared with previously reported results. Polarity errors for the ionization chamber studied were shown to monotonically increase with decreasing mean energy at a given depth and were maximal at about 1-2 MeV. It was also shown that polarity errors depended on the energy of the incident electron beam. The polarity error of the C-134A ionization chamber was larger than that of other previously investigated plane-parallel ionization chambers. Because the magnitude of polarity effects should be determined throughout the depth dose curve in therapeutic electron dosimetry, it is always necessary to measure ionization readings taken at both polarities.

Electrons↗

[Evaluation of the absorbed dosage in Compton tomography].

Tomographic images with electronic density can be obtained by irradiation with a monoenergetic beam and detection of the scattered Compton photons. The results of a dosimetric study on the beam of an irradiating Compton unit (equipped with two 192Ir 277.5 GBq sources) are here presented. Doses along the central axis of the beam were measured using thermoluminescent LIF-100 dosimeters. Measurements were taken both in water (RFA-3 Therados) and in cork phantoms. Isodose distributions were estimated by reading the automatic photo-densitometry of radiographic films. A simple algorithm for calculating depth dose values was obtained by analyzing experimental data. The mean absorbed dose (mad) in soft tissues (up to 25 cm deep) was 2.81 mGy for a work load of 7.4 X 10(11) Bq min. The mad in standard thorax was calculated also, which amounted to 3.78 mGy.

Absorption↗

The clinical assessment of binocular vision before and after a working day.

This paper looks at the clinical investigative and measurement procedures used in assessing binocular vision at the beginning of a normal working day and compared with the same procedures carried out in the afternoon which included several hours of close work. In 84 young adults, it was found that dissociated heterophoria, associated heterophoria and fixation disparity increased. This was accompanied by visual symptoms. It is likely that any decompensation of heterophoria is worse at the end of a working day. The results of this investigation raise the question of the value of some clinical tests for binocular assessment carried out at the beginning of the day.

Adolescent↗

Near vision stress: vergence adaptation and accommodative fatigue.

Changes in the visual system following prolonged near work were investigated. Fifteen young, normal subjects undertook a severe, two hour long, binocular near visual task at 20 cm without any breaks. Fusional stress was assessed by near 'phoria change. Refractive change was measured with an autorefractometer to investigate whether transient myopia occurred and its subsequent recovery. The near task caused vergence adaptation which was primarily due to the fusional stress of the task (accounting for 67% of its variance). The 'phoria change was to a lesser extent (40%) dependent on the accommodative "stress" of the task. Fatigue of the accommodative system resulted in increased accommodative innervation to maintain the same accurate response. Increased innervation can continue after the task on subsequent distance viewing, resulting in transient myopia (mean 0.29 DS). This transient myopia was found to be due to a transient regression of the far point towards the subject's tonic accommodation level. This can be accounted for by a shift of the tonic level as well as an increased bias towards the pre-task tonic level.

Accommodation, Ocular↗

The influence of Cervantes on the future creator of psychoanalysis.

Our work is intended to recreate the origins of the 'future creator of psychoanalysis'. Cervantes had a decisive influence on Freud. Don Quixote occupied a central place during a period which we consider to be crucial in the creation of psychoanalysis; we refer to the summer of 1883 during which Freud confessed to Martha that he had become more interested in this book than in brain anatomy. In this work, Cervantes delves in-depth into problems which he had set out in The Colloquy of the Dogs, read by Freud in his adolescence when he was learning Spanish and which confronted some of the great psychoanalytic themes such as reality-fantasy, language, instinct and reason, traumatic situations, 'family romance', etc. These themes appear in a psychoanalytically structured dialogue in which one of the dogs, Berganza, tells his life story (in the form of catharsis) to the other dog, Cipión, with whom Freud identified himself. Basically, it is the psychotherapeutic model that Freud used with his own hysterical patients. Another dialogue which was essential for Freud was that of Don Quixote and Sancho Panza, due to the following major reasons (as well as others): For the clear discrimination between reality and fantasy as well as their interplay. Because madness is presented as a complex phenomenon, but intelligible in terms of human motives. For the penetrating description of the transition in Don Quixote from mania to depression. Because at that moment of his life, Freud himself was living through a personal conflict between his dreams of carrying out some scientific feat and the demands of attending to his mundane necessities.

Austria↗

Reproducibility and accuracy of three methods for assessment of demineralization depth of the occlusal surface: an in vitro examination.

This laboratory study of 100 occlusal surfaces investigated the reproducibility and accuracy of a visual ranked caries scoring system, an electronic caries scoring system (ECM) using a continuous conductance scale, and a radiographic ranked caries scoring system. Histological examination of the teeth served as a gold standard to validate the ability of each system to assess lesion depth and predict softened, demineralized dentine. After training, 3 examiners carried out each scoring system on two separate occasions. Kappa values for visual, ECM and radiographic ranked scoring systems showed good inter- and intra-examiner reproducibility levels and acceptable limits of agreement for ECM readings. When scoring systems were tabulated against histological scores there was a high correlation between the visual and ECM methods and lesion depth in both enamel and dentine, but radiographic examination could not detect enamel caries. When compared to the histological scoring, the Spearman correlation coefficients for the visual scoring ranged between 0.87 and 0.93, for the ECM between 0.80 and 0.85 and for the radiographic scoring system between 0.76 and 0.78. No tooth scored as visually sound had histological evidence of dentine caries. Soft dentine corresponded to demineralization involving the middle third of the dentine or more which was related to visual cavity formation or an ECM reading above 9 (score 3 or 4). The radiograph was an excellent predictor of soft dentine. In conclusion, the new visual system appears promising, but takes time to learn. The reproducibility and accuracy for the ECM is acceptable while radiographs miss early occlusal lesions.

Bicuspid↗

Depth cues do not underlie attentional modulations of the Stroop effect.

The well-known Stroop effect is usually attributed to the automaticity of word reading. Recently, Wühr and Waszak (2003) had participants name the color of one of two rectangles and found that words in the relevant object produced larger Stroop effects than did words in the irrelevant object or in the background. They attributed this difference to an object-based mechanism of attentional selection that amplifies processing of all the features of an attended object. However, in the displays used by Wühr and Waszak, occlusion suggested the presence of different depth planes. Hence, the increased Stroop effect could have resulted from perceiving the words to be in the same depth plane as the relevant object and not from perceiving the words to be parts of the relevant object. Two experiments tested between these accounts by using displays without monocular depth cues. The results of both experiments replicate those of Wühr and Waszak, supporting their object-based account.

Adult↗