PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fluorescence imaging”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Distribution of non-heme porphyrin content of individual erythrocytes by fluorescence image cytometry and its application to lead poisoning.

The quantitation of the non-heme porphyrin content of circulating erythrocytes is an important tool in the screening, diagnosis, and management of lead disease, iron deficiency anemia, and certain porphyrias. Useful information about these pathological conditions may be obtained from the distribution of the non-heme porphyrin content of individual red blood cells. An image-based cytometry system was developed and used to determine the cellular distributions of zinc protoporphyrin (ZPP) in the erythrocytes of normal and lead-exposed human subjects. The fluorescence cytometry system described here lends itself to a wide range of statistical studies of cell populations, in which extrinsic fluorescent probes or antibodies may be used instead of porphyrin. Image-based cytometry appears to offer a number of important advantages over the more conventional flow cytometry systems, including greater sensitivity, applicability to a wider range of cellular parameters, and the ability to retain images of each cell used in the survey for subsequent examination. Pairs of absorption and fluorescence images of many fields of dispersed immobilized red cells were acquired by means of a program which controls the microscope stage, focussing, shutters, filter wheels, and a cooled, slow-scan CCD camera. The observed marked differences in the ZPP distributions of erythrocytes from donors with chronic and acute lead exposure are discussed in terms of the metabolism of internalized lead.

Algorithms↗

Two-photon excitation fluorescence imaging of the living juxtaglomerular apparatus.

Recently, multiphoton excitation fluorescence microscopy has been developed that offers important advantages over confocal imaging, particularly for in vivo visualization of thick tissue samples. We used this state-of-the-art technique to capture high-quality images and study the function of otherwise inaccessible cell types and complex cell structures of the juxtaglomerular apparatus (JGA) in living preparations of the kidney. This structure has multiple cell types that exhibit a complex array of functions, which regulate the process of filtrate formation and renal hemodynamics. We report, for the first time, on high-resolution three-dimensional morphology and Z-sectioning through isolated, perfused kidney glomeruli, tubules, and JGA. Time-series images show how alterations in tubular fluid composition cause striking changes in single-cell volume of the unique macula densa tubular epithelium in situ and how they also affect glomerular filtration through alterations in associated structures within the JGA. In addition, calcium imaging of the glomerulus and JGA demonstrates the utility of this system in capturing the complexity of events and effects that are exerted by the specific hypertensive autacoid angiotensin II. This imaging approach to the study of isolated, perfused live tissue with multiphoton microscopy may be applied to other biological systems in which multiple cell types form a functionally integrated syncytium.

Angiotensin II↗

Ratiometric fluorescence-imaging assays of plant membrane traffic using polyproteins.

Fluorescent protein markers are widely used to report plant membrane traffic; however, effective protocols to quantify fluorescence or marker expression are lacking. Here the 20 residue self-cleaving 2A peptide from Foot and Mouth Disease Virus was used to construct polyproteins that expressed a trafficked marker in fixed stoichiometry with a reference protein in a different cellular compartment. Various pairs of compartments were simultaneously targeted. Together with a bespoke image analysis tool, these constructs allowed biosynthetic membrane traffic to be assayed with markedly improved sensitivity, dynamic range and statistical significance using protocols compatible with the common plant transfection and transgenic systems. As marker and effector expression could be monitored in populations or individual cells, saturation phenomena could be avoided and stochastic or epigenetic influences could be controlled. Surprisingly, mutational analysis of the ratiometric assay constructs revealed that the 2A peptide was dispensable for efficient cleavage of polyproteins carrying a single internal signal peptide, whereas the signal peptide was essential. In contrast, a construct bearing two signal peptide/anchors required 2A for efficient separation and stability, but 2A caused the amino-terminal moiety of such fusions to be mis-sorted to the vacuole. A model to account for the behaviour of 2A in these and other studies in plants is proposed.

Amino Acid Sequence↗

Fluorescence imaging of electrical activity in cardiac cells using an all-solid-state system.

Tracking spatial and temporal determinants of cardiac arrhythmogenesis at the cellular level presents challenges to the optical mapping techniques employed. In this paper, we describe a compact system combining two nontraditional low-cost solutions for excitation light sources and emission filters in fluorescence measurements of transmembrane potentials, Vm, or intracellular calcium, [Ca2+]i in cardiac cell networks. This is the first reported use of high-power blue and green light emitting diodes (LEDs), to excite cell monolayers stained with Vm - (di-8-ANEPPS) or [Ca2+]i - (Fluo-3) sensitive dyes. In addition, we use simple techniques for fabrication of suitable thin emission filters with uniform properties, no auto-fluorescence, high durability and good flexibility for imaging Vm or [Ca2+]i. The battery-operated LEDs and the fabricated emission filters, integrated with a fiber-optic system for contact fluorescence imaging, were used as tools to characterize conduction velocity restitution at the macro-scale. The versatility of the LEDs for illumination is further emphasized through 1) demonstration of their usage for epi-illumination recordings at the single-cell level, and 2) demonstration of their unique high-frequency light modulation ability. The LEDs showed excellent stability as excitation light sources for fluorescence measurements; acceptable signal-to-noise ratio and negligible cell photodamage and indicator dye photobleaching were observed.

Action Potentials↗

Fluorescence imaging reveals the nuclear behavior of peroxisome proliferator-activated receptor/retinoid X receptor heterodimers in the absence and presence of ligand.

In a global approach combining fluorescence recovery after photobleaching (FRAP), fluorescence correlation spectroscopy (FCS), and fluorescence resonance energy transfer (FRET), we address the behavior in living cells of the peroxisome proliferator-activated receptors (PPARs), a family of nuclear receptors involved in lipid and glucose metabolism, inflammation control, and wound healing. We first demonstrate that unlike several other nuclear receptors, PPARs do not form speckles upon ligand activation. The subnuclear structures that may be observed under some experimental conditions result from overexpression of the protein and our immunolabeling experiments suggest that these structures are subjected to degradation by the proteasome. Interestingly and in contrast to a general assumption, PPARs readily heterodimerize with retinoid X receptor (RXR) in the absence of ligand in living cells. PPAR diffusion coefficients indicate that all the receptors are engaged in complexes of very high molecular masses and/or interact with relatively immobile nuclear components. PPARs are not immobilized by ligand binding. However, they exhibit a ligand-induced reduction of mobility, probably due to enhanced interactions with cofactors and/or chromatin. Our study draws attention to the limitations and pitfalls of fluorescent chimera imaging and demonstrates the usefulness of the combination of FCS, FRAP, and FRET to assess the behavior of nuclear receptors and their mode of action in living cells.

Active Transport, Cell Nucleus↗

In vivo near-infrared fluorescence imaging.

Photon penetration into living tissue is highly dependent on the absorption and scattering properties of tissue components. The near-infrared region of the spectrum offers certain advantages for photon penetration, and both organic and inorganic fluorescence contrast agents are now available for chemical conjugation to targeting molecules. This review focuses on those parameters that affect image signal and background during in vivo imaging with near-infrared light and exogenous contrast agents. Recent examples of in vivo near-infrared fluorescence imaging of animals and humans are presented, including imaging of normal and diseased vasculature, tissue perfusion, protease activity, hydroxyapatite and cancer.

Animals↗

Fluorescence imaging microscopy of cellular markers in ischemic vs non-ischemic cardiomyopathy after left ventricular unloading.

BACKGROUND: The heart undergoes repair and initiates protective mechanisms via ventricular unloading. We examined the presence of 2 markers in pre-unloaded and post-unloaded human cardiac tissue that are important indicators of cardiac failure, tumor necrosis factor-alpha and inducible nitric oxide synthase. We also measured 2 nuclear transcription factors, NFkappaB50 and NFkappaB65, comparing quantities and localizations to determine if mechanical unloading reduced their presence, as these markers are also thought to be indicators of impending heart failure. Amounts and localizations in patients that had been diagnosed with either ischemic or non-ischemic cardiomyopathy were compared after mechanical unloading with a left ventricular assist device. To establish that unloading had been achieved, levels of atrial natriuretic protein were determined. METHODS: Core biopsies were harvested at assist device implantation and removal. Fluorescence deconvolution microscopy image reconstructions of fluorescence probes were correlated with data obtained by western Blot and electrobility shift assays. RESULTS: Statistically significant differences in localization and amounts of tumor necrosis factor and nitric oxide synthase were seen between pre- and post-assist device samples. Amounts of tumor necrosis factor and nitric oxide synthase in ischemic tissue were increased at the time of assist device removal, but decreased in dilated or idiomyopathic samples. Ventricular unloading resulted in reduced levels of natriuretic protein, with the greatest reduction being seen in ischemic tissue. Both NFkappaB50 and NFkappaB65 increased in ischemic tissue, but only NFkappaB50 in non-ischemic samples. CONCLUSIONS: Changes in localization of the factors and altered levels of cytokine and nitric oxide synthase indicate that the heart switches to a "protective and repair" mode, and mechanical unloading allows this transition to occur. Observed changes were dependent on the etiology of the disease.

Atrial Natriuretic Factor↗

Near-infrared fluorescent imaging of matrix metalloproteinase activity after myocardial infarction.

BACKGROUND: We used a molecular probe activated by protease cleavage to image expression of matrix metalloproteinases (MMPs) in the heart after myocardial infarction. METHODS AND RESULTS: We synthesized and characterized a near-infrared fluorescent (NIRF) probe that is activated by proteolytic cleavage by MMP2 and MMP9. The NIRF probe was injected into mice at various time points up to 4 weeks after myocardial infarction induced by ligation of the left anterior descending coronary artery. NIRF imaging of MMP activity increased in the infarct region, with maximal expression at 1 to 2 weeks, persisting to 4 weeks. Zymography and real-time polymerase chain reaction analysis showed that MMP9 expression is increased at 2 to 4 days, and MMP2 expression is increased at 1 to 2 weeks. Dual-label confocal microscopy showed colocalization of NIRF imaging with neutrophils on day 2, and flow cytometric analysis confirmed that NIRF signal is associated with leukocytes in the infarct zone. CONCLUSIONS: This study demonstrates that the activity of MMPs in the myocardium may be imaged by use of specific activity-dependent molecular probes.

Animals↗

Time-resolved confocal fluorescence imaging and spectrocopy system with single molecule sensitivity and sub-micrometer resolution.

We present novel technical features and results from a two channel confocal fluorescence lifetime microscope, which allows to efficiently investigate fluorescence dynamics down to the single molecule level. The MicroTime 200 time-resolved fluorescence microscope offers a multicolor excitation where different picosecond diode lasers are used. For imaging and positioning purposes we utilize a compact Piezo scanner which allows, due to a novel scanning algorithm and synchronisation technique, a superior movement and positioning accuracy. The data acquisition is completely based on time-correlated single photon counting, where every photon is detected and stored individually with its specific timing information (Time-Tagged Time-Resolved mode). This multiparameter data acquisition scheme offers the opportunity to analyse the parameter dependencies in a multitude of different ways. Standard intensity analysis can be used to reconstruct 2D-images or the temporal evolution (time trace) of the fluorescence of a single spot. The information from the two distinct detector channels additionally allows to investigate the polarisation of the emitted light or its spectral composition, for example for analysis of Fluorescence Resonance Energy Transfer (FRET). The timing information down to a picosecond scale offers the possibility not only to reconstruct fluorescence decay constants of each pixel for the purpose of Fluorescence Lifetime Imaging (FLIM) but also to analyze the fluorescence fluctuation correlation function of any single spot of interest. The flexible multichannel detector scheme enables in this case also a cross-correlation between spectrally separated parts of the emission light, or even identical parts of the fluorescence to eliminate detector artifacts. The photon arrival coincidence analysis can also be expanded in the sub-ns range to study fluorescence antibunching in the fluorescence emission of single molecules. The ability of combining these different pieces of temporal information allows the construction of extremely powerful analysis methods and assays. We demonstrate a variety of these capabilities with results obtained from fluorescently labeled latex beads, biological samples, and single molecules excited in the blue or red wavelength region.

Equipment Design↗

Classification accuracy in multiple color fluorescence imaging microscopy.

BACKGROUND: The discriminatory power and imaging efficiency of different multicolor FISH (M-FISH) analysis systems are key factors in obtaining accurate and reproducible classification results. In a recent paper, Garini et al. put forth an analytical technique to quantify the discriminatory power ("S/N ratio") and imaging efficiency ('excitation efficiency') of multicolor fluorescent karyotyping systems. METHODS: A parametric model of multicolor fluorescence microscopy, based on the Beer-Lambert law, is analyzed and reduced to a simple expression for S/N ratio. Parameters for individual system configurations are then plugged into the model for comparison purposes. RESULTS: We found that several invalid assumptions, which are used to reduce the complex mathematics of the Beer-Lambert law to a simple S/N ratio, result in some completely misleading conclusions about classification accuracy. The authors omit the most significant noise source, and consider only one highly abstract and unrepresentative situation. Unwisely chosen parameters used in the examples lead to predictions that are not consistent with actual results. CONCLUSIONS: The earlier paper presents an inaccurate view of the M-FISH situation. In this short communication, we point out several inaccurate assumptions in the mathematical development of Garini et al. and the poor choices of parameters in their examples. We show results obtained with different imaging systems that indicate that reliable and comparable results are obtained if the metaphase samples are well-hybridized. We also conclude that so-called biochemical noise, not photon noise, is the primary factor that limits pixel classification accuracy, given reasonable exposure times.

Chromosomes↗

Oligomerization of epidermal growth factor receptors on A431 cells studied by time-resolved fluorescence imaging microscopy. A stereochemical model for tyrosine kinase receptor activation.

The aggregation states of the epidermal growth factor receptor (EGFR) on single A431 human epidermoid carcinoma cells were assessed with two new techniques for determining fluorescence resonance energy transfer: donor photobleaching fluorescence resonance energy transfer (pbFRET) microscopy and fluorescence lifetime imaging microscopy (FLIM). Fluorescein-(donor) and rhodamine-(acceptor) labeled EGF were bound to the cells and the extent of oligomerization was monitored by the spatially resolved FRET efficiency as a function of the donor/acceptor ratio and treatment conditions. An average FRET efficiency of 5% was determined after a low temperature (4 degrees C) incubation with the fluorescent EGF analogs for 40 min. A subsequent elevation of the temperature for 5 min caused a substantial increase of the average FRET efficiency to 14% at 20 degrees C and 31% at 37 degrees C. In the context of a two-state (monomer/dimer) model for the EGFR, these FRET efficiencies were consistent with minimal average receptor dimerizations of 13, 36, and 69% at 4, 20, and 37 degrees C, respectively. A431 cells were pretreated with the monoclonal antibody mAb 2E9 that specifically blocks EGF binding to the predominant population of low affinity EGFR (15). The average FRET efficiency increased dramatically to 28% at 4 degrees C, indicative of a minimal receptor dimerization of 65% for the subpopulation of high affinity receptors. These results are in accordance with prior studies indicating that binding of EGF leads to a fast and temperature-dependent microclustering of EGFR, but suggest in addition that the high affinity functional subclass of receptors on quiescent A431 cells are present in a predimerized or oligomerized state. We propose that the transmission of the external ligand-binding signal to the cytoplasmic domain is effected by a concerted relative rotational rearrangement of the monomeric units comprising the dimeric receptor, thereby potentiating a mutual activation of the tyrosine kinase domains.

Binding, Competitive↗

In vivo near-infrared fluorescence imaging of integrin alphavbeta3 in an orthotopic glioblastoma model.

PURPOSE: Expression of cell adhesion molecule integrin alpha(v)beta(3) is significantly up-regulated during tumor growth, and sprouting of tumor vessels and correlates well with tumor aggressiveness. The purpose of this study was to visualize tumor integrin alpha(v)beta(3) expression in vivo by using near-infrared fluorescence (NIRF) imaging of Cy5.5-linked cyclic arginine-glycine-aspartic acid (RGD) peptide in an orthotopic brain tumor model. PROCEDURES: U87MG glioma cells transfected with the firefly luciferase gene were stereotactically injected into nude mice in the right frontal lobe. Bioluminescence imaging (BLI) using D: -luciferin substrate and small animal magnetic resonance imaging (MRI) using gadolinium contrast enhancement were conducted weekly after tumor cell inoculation to monitor intracranial tumor growth. Integrin alpha(v)beta(3) expression was assessed by using a three-dimensional optical imaging system (IVIS 200) 0-24 hours after administration of 1.5 nmol monomeric Cy5.5-RGD via the tail vein. Animals were injected intravenously with both Texas Red-tomato lectin and Cy5.5-RGD prior to sacrifice to visualize peptide localization to tumor vasculature using histology. RESULTS: Fluorescence microscopy demonstrated specific Cy5.5-RGD binding to both U87MG tumor vessels and tumor cells with no normal tissue binding. NIRF imaging showed highest tumor uptake and tumor to normal brain tissue ratio two hours postinjection (2.64 +/- 0.20). Tumor uptake of Cy5.5-RGD was effectively blocked by using unlabeled c(RGDyK), and injection of Cy5.5 dye alone showed nonspecific binding. CONCLUSIONS: Optical imaging via BLI and NIRF offer a simple, effective, and rapid technique for noninvasive in vivo monitoring and semiquantitative analysis of intracranial tumor growth and integrin alpha(v)beta(3) expression. This study suggests that NIRF via fluorescently labeled RGD peptides may provide enhanced surveillance of tumor angiogenesis and anti-integrin treatment efficacy in orthotopic brain tumor models.

Animals↗

Heterogeneity of Ca2+-permeable AMPA/kainate channel expression in hippocampal pyramidal neurons: fluorescence imaging and immunocytochemical assessment.

The presence of Ca2+-permeable AMPA/kainate (Ca-A/K) channels on hippocampal pyramidal neurons (HPNs) has been controversial, although they are present on many forebrain GABAergic neurons. We combined high-resolution fluorescence Ca2+ imaging with surface AMPA receptor (AMPAR) subunit immunocytochemistry to examine the expression of functional Ca-A/K channels in dissociated hippocampal neurons at the subcellular level. In GABAergic neurons [identified by glutamate decarboxylase (GAD) immunocytochemistry], focal application of AMPA induced large dendrosomatic intracellular [Ca2+] ([Ca2+]i) rises, consistent with their known strong Ca-A/K channel expression. Surface immunostaining for the AMPAR subunits GluR1 and GluR2 revealed abundant dendritic GluR1 puncta containing little or no GluR2, which, when present, was limited to diffuse staining in the soma and proximal dendrites. In contrast, the majority of HPNs (putatively identified by morphological criteria and lack of GAD labeling) showed little or no AMPA-induced [Ca2+]i rise. Correspondingly, most HPNs showed strong dendritic labeling for both GluR1 and GluR2 that colocalized extensively. A subpopulation of HPNs, however, displayed noticeable [Ca2+]i rises that began and often reached their highest levels in discrete dendritic regions. In these HPNs, levels of GluR1 relative to GluR2 were higher, and GluR1 was often present without overlying GluR2. The present studies, which are the first to directly examine the relationship between the local complement of cell surface AMPAR and the presence of dendritic Ca-A/K channels, clearly indicate that considerable cell surface GluR2 does not preclude the presence of Ca-A/K channels and further show that HPNs display considerable heterogeneity in terms of apparent Ca-A/K channel expression.

Animals↗

Use of block copolymer-stabilized cadmium sulfide quantum dots as novel tracers for laser scanning confocal fluorescence imaging of blend morphology in polystyrene/poly(methyl methacrylate) films.

This paper describes the first use of polymer-coated quantum dots (QDs) as fluorescent tracers for LSCFM imaging of phase morphology in polymer blends. Cadmium sulfide (CdS) QDs stabilized at the surface with a PS-b-PAA block copolymer are shown to be well dispersed via their polystyrene (PS) brush layer in the PS phase of solvent-cast 40/60 (w/w) PS/PMMA blends. The QDs are excluded from the PMMA phase, providing excellent fluorescence contrast for LSCFM imaging of the phase-separated blends. The presence of PS-b-PAA-stabilized QDs does not appear to affect the blend morphology, since the observed morphologies are the same when the percentage of QDs within the PS phase is varied from 10 to 50 wt %. These QD fluorescent tracers are used to characterize several aspects of blend morphology in solvent-cast 40/60 PS/PMMA blends containing PS homopolymer with either 100 (low molecular weight) or 1250 (high molecular weight) repeat units. In the PS(1250)/PMMA blends, a percolating distribution of PMMA droplets (2-25 mum) in a PS matrix is observed in the bulk, and a distinct inversion in the continuous phase is found near the glass substrate. In the PS(100)/PMMA blends, a "phase-in-phase" morphology is found, consisting of large PS domains (20-100 mum) dispersed in a PMMA continuous phase and small PMMA domains (1-2 mum) scattered throughout the larger PS droplets. The observed change in blend structure is attributed to a lower interfacial tension for the lower molecular weight PS.

Journal Article↗

The effects of illumination and focal distance on light-induced fluorescence images in vitro.

When using quantitative light-induced fluorescence a number of factors can influence illumination level. The purpose of this study was to investigate, using a high-resolution camera and fibre-optic light source, the impact of illumination level and focal distance on common quantitative light-induced fluorescence outcomes. Twenty-four extracted teeth were examined using 6 illumination levels and 4 focal distances. Analysis was conducted using multiple linear regression models fitted to log DeltaQ, log DeltaF and log area with clustering of teeth and robust standard errors. Separate models were used for the different light and focal levels. The regression coefficients were significant for both DeltaQ and DeltaF but not area. Despite the significant regressions the actual effect was very small, and unlikely to confound clinical trial or practice results.

Dental Caries Activity Tests↗

Scanning surface confocal microscopy for simultaneous topographical and fluorescence imaging: application to single virus-like particle entry into a cell.

We have developed a method for simultaneous recording of high-resolution topography and cell surface fluorescence in a single scan which we call scanning surface confocal microscopy. The resolution of the system allows imaging of individual fluorescent particles in the nanometer range on fixed or live cells. We used this technique to record the interaction of single virus-like particles with the cell surface and demonstrated that single particles sink into the membrane in invaginations reminiscent of caveolae or pinocytic vesicles. This method provides a technique for elucidating the interaction of individual viruses and other nanoparticles, such as gene therapy vectors, with target cells. Furthermore, this technique should find widespread application for studying the relationship of fluorescently tagged molecules with components of the cell plasma membrane.

Animals↗

Catheter confocal fluorescence imaging and functional magnetic resonance imaging of local and systems level recovery in the regenerating rodent sciatic nerve.

The goal of the present work was to develop minimally invasive imaging techniques to monitor local regeneration of peripheral nerves and to determine the extent of return to function of brain cortical regions associated with that nerve. The sciatic nerve crush model was applied to Sprague-Dawley rats and conventional histological staining for myelin, axons and cell architecture was carried out, as well as traditional behavioral testing, to verify that nerve regeneration was occurring. The rate of sciatic nerve regeneration was measured by determining the distance a lipophilic, fluorescence probe (DiO) would move along the nerve's membrane following a direct injection into the sciatic nerve. This movement was monitored using a catheter based, confocal fluorescence microscope. Two to five days after the crush, the dye moved 1.4 + 0.6 mm/day, as compared to a distance of 5.3 + 0.5 mm/day in the normal nerve. Between 9 and 13 days following the crush, the distance the dye moved increases to 5.5 + 0.5 mm/day, similar to the control, and by 15 days following the crush, the distance increased to 6.5 + 0.9 mm/day. Functional Magnetic Resonance Imaging (fMRI) measurements were performed on alpha-chloralose anesthetized rats to monitor the return of somatosensory cortical functions, which were activated by the stimulation of the lesioned peripheral nerve. fMRI results showed the return of cortical activation around 15 days following the crush procedure. However, the somatosensory cortical region activated by stimulating the crushed hindpaw was significantly smaller in extent than the intact hindpaw stimulation. These findings demonstrate that fluorescence imaging and fMRI can integrate local and system level correlates of nerve regeneration in a non-destructive manner, thus enabling serial imaging of individual animals.

Animals↗

Seven-color fluorescence imaging of tissue samples based on Fourier spectroscopy and singular value decomposition.

Seven-color analyses of immunofluorescence-stained tissue samples were accomplished using Fourier spectroscopy-based hyperspectral imaging and singular value decomposition. This system consists of a combination of seven fluorescent dyes, three filtersets, an epifluorescence microscope, a spectral imaging system, a computer for data acquisition, and data analysis software. The spectra of all pixels in a multicolor image were taken simultaneously using a Sagnac type interferometer. The spectra were deconvolved to estimate the contribution of each component dye, and individual dye images were constructed based on the intensities of assigned signals. To obtain mixed spectra, three filter sets, i.e., Bl, Gr, and Rd for Alexa488 and Alexa532, for Alexa546, Alexa568, and Alexa594, and for Cy5 and Cy5.5, respectively, were used for simultaneous excitation of two or three dyes. These fluorophores have considerable spectral overlap which precludes their separation by conventional analysis. We resolved their relative contributions to the fluorescent signal by a method involving linear unmixing based on singular value decomposition of the matrices consisting of dye spectra. Analyses of mouse thymic tissues stained with seven different fluorescent dyes provided clear independent images, and any combination of two or three individual dye images could be used for constructing multicolor images.

Animals↗