PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19Linked to original sources

Microbioassay system for an anti-cancer agent test using animal cells on a microfluidic gradient mixer.

We developed a novel microbioassay system equipped with a gradient mixer of two solutions, and we applied the microfluidic system to an anti-cancer agent test using living animal cells on a microchip. A microchannel for the gradient mixing of two solutions and eight other microchannels for cell assay were fabricated on a poly(dimethylsiloxane) substrate using a soft-lithography method. The functions necessary for this bioassay, i.e., cell culturing, chemical stimulation, cell staining, and fluorescence determination, were integrated into the microfluidic chip. Eight gradient concentrations of the fluorescein solution, ranging from 1 to 98 microg/ml, were archived at 0.1 microl/min on a microchip. A stomach cancer cell line was cultured, and a cell viability assay was conducted using 5-Fluorouracil as an anti-cancer agent on the microchip. Cell viability changed according to the estimated concentration of the agent solution. With the microbioassay system, an anti-cancer agent test was conducted using living cells simultaneously in eight individual channels with the gradient concentration of the agent on a microchip.

Animals↗

Bacterial P450-catalyzed polyketide hydroxylation on a microfluidic platform.

The incorporation of a multicomponent, cofactor-dependant P450 into a microfluidic biochip is demonstrated. The PikC hydroxylase Streptomyces venezuelae was incorporated into a PDMS-based microfluidic channel. The enzyme was immobilized to Ni-NTA agarose beads via in situ attachment following the addition of the beads to the microchannel. The enzyme loading was approximately 6 microg per mg of beads resulting in a microchannel loading of 10.7 mg/mL. This high enzyme loading enabled the rapid hydroxylation of the macrolide YC-17 to methymycin and neomethymycin in about equal amounts with a conversion of >90% at a flow rate of 70 nL/min. This high reactivity allowed rapid hydroxylation reactions to be performed with short residence times, which is critical for complex enzymes with limited inherent stability.

Bioreactors↗

Enrichment using antibody-coated microfluidic chambers in shear flow: model mixtures of human lymphocytes.

Isolation of phenotypically-pure cell subpopulations from heterogeneous cell mixtures such as blood is a difficult yet fundamentally important task. Current techniques such as fluorescent activated cell sorting (FACS) and magnetic-activated cell sorting (MACS) require pre-incubation with antibodies which lead to processing times of at least 15-60 min. In this study, we explored the use of antibody-coated microfluidic chambers to negative deplete undesired cell types, thus obtaining an enriched cell subpopulation at the outlet. We used human lymphocyte cell lines, MOLT-3 and Raji, as a model system to examine the dynamic cell binding behavior on antibody coated surfaces under shear flow. Shear stress ranging between 0.75 and 1.0 dyn/cm2 was found to provide most efficient separation. Cell adhesion was shown to follow pseudo-first order kinetics, and an anti-CD19 coated (Raji-depletion) device with approximately 2.6 min residence time was demonstrated to produce 100% pure MOLT-3 cells from 50-50 MOLT-3/Raji mixture. We have developed a mathematical model of the separation device based on the experimentally determined kinetic parameters that can be extended to design future separation modules for other cell mixtures. We conclude that we can design microfluidic devices that exploits the kinetics of dynamic cell adhesion to antibody coated surfaces to provide enriched cell subpopulations within minutes of total processing time.

Antibodies↗

Preconcentration and separation of double-stranded DNA fragments by electrophoresis in plastic microfluidic devices.

We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard trade mark devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/microL of DNA in 0.1xpolymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.

Automation↗

Microfluidic systems in proteomics.

We present the state-of-the-art in miniaturized sample preparation, immunoassays, one-dimensional and multidimensional analyte separations, and coupling of microdevices with electrospray ionization-mass spectrometry. Hyphenation of these different techniques and their relevance to proteomics will be discussed. In particular, we will show that analytical performances of microfluidic analytical systems are already close to fulfill the requirements for proteomics, and that miniaturization results at the same time in a dramatic increase in analysis throughput. Throughout this review, some examples of analytical operations that cannot be achieved without microfluidics will be emphasized. Finally, conditions for the spreading of microanalytical systems in routine proteomic labs will be discussed.

Electrophoresis↗

Surface characterization using chemical force microscopy and the flow performance of modified polydimethylsiloxane for microfluidic device applications.

The widespread interest in micro total analysis systems has resulted in efforts to develop devices in cheaper polymer materials such as polydimethylsiloxane (PDMS) as an alternative to expensive glass and silicon devices. We describe the oxidation of the PDMS surface to form ionizable groups using a discharge from a Tesla coil and subsequent chemical modification to augment electroosmotic flow (EOF) within the microfluidic devices. The flow performance of oxidized, amine-modified and unmodified PDMS materials has been determined and directly compared to conventional glass devices. Exact PDMS replicas of glass substrates were prepared using a novel two step micromolding protocol. Chemical force microscopy has been utilized to monitor and measure the efficacy of surface modification yielding information about the acid/base properties of the modified and unmodified surfaces. Results with different substrate materials correlates well with expected flow modifications as a result of surface modification. Oxidized PDMS devices were found to support faster EOF (twice that of native PDMS) similar to glass while those derivatized with 3-aminopropyl triethoxysilane (APTES) showed slower flow rates compared to native PDMS substrates as a result of masking surface charge. Results demonstrate that the surface of PDMS microdevices can be manipulated to control EOF characteristics using a facile surface derivatization methodology allowing surfaces to be tailored for specific microfluidic applications and characterized with chemical force microscopy.

Dimethylpolysiloxanes↗

Microfluidic tectonics platform: A colorimetric, disposable botulinum toxin enzyme-linked immunosorbent assay system.

A fabrication platform for realizing integrated microfluidic devices is discussed. The platform allows for creating specific microsystems for multistep assays in an ad hoc manner as the components that perform the assay steps can be created at any location inside the device via in situ fabrication. The platform was utilized to create a prototype microsystem for detecting botulinum neurotoxin directly from whole blood. Process steps such as sample preparation by filtration, mixing and incubation with reagents was carried out on the device. Various microfluidic components such as channel network, valves and porous filter were fabricated from prepolymer mixture consisting of monomer, cross-linker and a photoinitiator. For detection of the toxoid, biotinylated antibodies were immobilized on streptavidin-functionalized agarose gel beads. The gel beads were introduced into the device and were used as readouts. Enzymatic reaction between alkaline phosphatase (on secondary antibody) and substrate produced an insoluble, colored precipitate that coated the beads thus making the readout visible to the naked eye. Clinically relevant amounts of the toxin can be detected from whole blood using the portable enzyme-linked immunosorbent assay (ELISA) system. Multiple layers can be realized for effective space utilization and creating a three-dimensional (3-D) chaotic mixer. In addition, external materials such as membranes can be incorporated into the device as components. Individual components that were necessary to perform these steps were characterized, and their mutual compatibility is also discussed.

Antibodies↗

Total serum protein N-glycome profiling on a capillary electrophoresis-microfluidics platform.

We implemented 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled asparagine-linked glycan (N-glycan) profiling on a microfluidic electrophoresis platform. Using 11.5 cm effective length etched channels and 4% linear polyacrylamide as the separation matrix, the major N-glycans in human serum were profiled in 12 min with a resolution comparable to what is achieved for these analytes on gel-based DNA sequencers. This demonstration suggests a practical clinical application for high-speed compact analyzers which might be uniquely based on microfluidic devices.

Electrophoresis, Capillary↗

Immobilized microfluidic enzymatic reactors.

The use of enzymes for cleavage, synthesis or chemical modification represents one of the most common processes used in biochemical and molecular biology laboratories. The continuing progress in medical research, genomics, proteomics, and related emerging biotechnology fields leads to exponential growth of the applications of enzymes and the development of modified or new enzymes with specific activities. Concurrently, new technologies are being developed to improve reaction rates and specificity or perform the reaction in a specific environment. Besides large-scale industrial applications, where typically a large processing capacity is required, there are other, much lower-scale applications, benefiting form the new developments in enzymology. One such technology is microfluidics with the potential to revolutionize analytical instrumentation for the analyses of very small sample amounts, single cells or even subcellular assemblies. This article aims at reviewing the current status of the development of the immobilized microfluidic enzymatic reactors (IMERs) technology.

Animals↗

Recent developments in detection for microfluidic systems.

Microfluidic systems have become more and more important in the field of analytical chemistry. Detection methods on these microsystems are essential for the identification and quantification of chemical species that are being analyzed. This review concentrates on the latest developments of optical detection methods and mass spectrometry in conjunction with microfluidic systems. Electrochemical methods are discussed in another review in the same issue of this journal. Within the optical detection section, topics such as multiplexed detection and the use of waveguides are discussed. Within the discussion of mass spectrometry, the main focus is on electrospray emitters as interfaces between microsystem and spectrometer. Apart from optical detection and mass spectrometry, other techniques such as flame ionization and nuclear magnetic resonance are also mentioned.

Equipment Design↗

Isoelectric focusing in cyclic olefin copolymer microfluidic channels coated by polyacrylamide using a UV photografting method.

As an alternative material to glass or silicon, microfluidic devices made from a cyclic olefin copolymer (COC) were fabricated. This material is of interest because of the relative ease of fabrication, low costs, and solvent resistance. However, as a result of the strong hydrophobic interactions normally present, COC surfaces are not suitable for protein separations. To reduce the protein adsorption and make COC suitable for protein separations, UV-initiated grafting of polyacrylamide was used to coat the surface of COC devices. The change in surface properties caused by different graft times was studied. The surface hydrophilicity and electroosmotic mobility were characterized by contact angle and electroosmosis measurements. Isoelectric focusing was performed to test protein separations in polyacrylamide-coated COC microchannels. A single protein, carbonic anhydrase, was used to analyze the focusing effects and peak capacities in uncoated and polyacrylamide-coated COC devices. Peak capacities ranging from 75 to 190 were achieved with a polyacrylamide-coated surface. A mixture of two proteins, conalbumin labeled with Alexa Fluor 488 and beta-lactoglobulin A labeled with Alexa Fluor 546, was used to test protein separations. Linear and rapid separation of proteins was achieved in the polyacrylamide-coated COC microfluidic device.

Acrylic Resins↗

Temperature measurements in microfluidic systems: heat dissipation of negative dielectrophoresis barriers.

The manipulation of living biological cells in microfluidic channels by a combination of negative dielectrophoretic barriers and pressure-driven flows is widely employed in lab-on-a-chip systems. However, electric fields in conducting media induce Joule heating. This study investigates if the local temperatures reached under typical experimental conditions in miniaturized systems cause a potential risk for hyperthermic stress or cell damage. Two methods of optical in situ temperature detection have been tested and compared: (i) the exposure of the thermo-dependent fluorescent dye Rhodamine B to heat sources situated in microfluidic channels, and (ii) the use of thermoprecipitating N-alkyl-substituted acrylamide polymers as temperature threshold probes. Two-dimensional images of temperature distributions in the vicinity of active negative dielectrophoresis (nDEP)-barriers have been obtained and local temperature variations of more than 20 degrees C have been observed at the electrode edges. Heat propagation via both buffer and channel walls lead to significant temperature increases within a perimeter of 100 microm and more. These data indicate that power dissipation has to be taken into account when experiments at physiological temperatures are planned.

Cell Physiological Phenomena↗

Unconventional detection methods for microfluidic devices.

The direction of modern analytical techniques is to push for lower detection limits, improved selectivity and sensitivity, faster analysis time, higher throughput, and more inexpensive analysis systems with ever-decreasing sample volumes. These very ambitious goals are exacerbated by the need to reduce the overall size of the device and the instrumentation - the quest for functional micrototal analysis systems epitomizes this. Microfluidic devices fabricated in glass, and more recently, in a variety of polymers, brings us a step closer to being able to achieve these stringent goals and to realize the economical fabrication of sophisticated instrumentation. However, this places a significant burden on the detection systems associated with microchip-based analysis systems. There is a need for a universal detector that can efficiently detect sample analytes in real time and with minimal sample manipulation steps, such as lengthy labeling protocols. This review highlights the advances in uncommon or less frequently used detection methods associated with microfluidic devices. As a result, the three most common methods - LIF, electrochemical, and mass spectrometric techniques - are omitted in order to focus on the more esoteric detection methods reported in the literature over the last 2 years.

Electrophoresis, Capillary↗

DNA sequencing and multiplex STR analysis on plastic microfluidic devices.

The ability of plastic microfluidic devices with separation channel lengths of 6, 10 or 18 cm to perform high-quality and high-performance ssDNA analysis was evaluated. Specifically, four-color DNA sequencing separation of a terminator sequencing standard using replaceable, urea-denaturing linear polyacrylamide (LPA) solution as a sieving matrix, yielded read lengths of 410 bases in 15 min with base calling accuracy of 99.2% on a 6-cm device, and 640 bases in 35 min with accuracy of 98.0% on a 18-cm device. A two-color sizing analysis of four-locus (CSF1PO, TPOX, TH01, vWA) short tandem repeats (STRs) allelic ladder on a 10-cm device indicated a mean SD of +/- 0.08 base pairs (bp) between runs, and single bp resolution of spiked TH01 allele 9.3 (198 bp) from TH01 allele 10 (199 bp) of the CTTv ladder with R = 0.81. A four-color multiplex sizing analysis of three different AmpFlSTR allelic ladders consisting of nine loci (D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820) and gender alleles (Amelogenin) on a 10-cm device had a mean SD of +/- 0.15 bp between runs for sizing three loci, i.e., FGA, D18S51 and D3S818; alleles differing by 2 bp in size were resolved with resolutions close to baseline. This work demonstrates that plastic microfluidic devices are capable of quality sequencing and STR sizing comparable to that of glass devices of similar separation lengths.

DNA, Single-Stranded↗

Genotyping with microfluidic devices.

In the past few years, electrophoresis microchips have been increasingly utilized to interrogate genetic variations in the human and other genomes. Microfluidic devices can be readily applied to speed up existing genotyping protocols, in particular the ones that require electric field-mediated separations in conjunction with restriction fragment analysis, DNA sequencing, hybridization-based techniques, allele-specific amplification, heteroduplex analysis, just to list the most important ones. As a result of recent developments, microfabricated electrophoresis devices offer several advantages over conventional slab-gel electrophoresis, such as small sample volume requirement, low reagent consumption, the option of system integration and easy multiplexing. The analysis speed of microchip electrophoresis is significantly higher than that of any other electric field-mediated separation techniques. State-of-the-art microfluidic bioanalytical devices already claim their place in most molecular biology laboratories. This review summarizes the recent developments in microchip electrophoresis methods of nucleic acids, particularly for rapid genotyping, that will most likely play a significant role in the future of clinical diagnostics.

Animals↗

Usefulness of an integrated microfluidic device (HPLC-Chip-MS) to enhance confidence in protein identification by proteomics.

Nanoflow liquid chromatography/mass spectrometry (nanoLC/MS) has become a current tool in proteomics applications increasingly used in the search for new biomarkers. A new integrated microfluidic device (HPLC-Chip), coupled to ion trap mass spectrometry (ITMS), appears as an innovative and robust tool for improving the identifications commonly performed by nanoLC/MS/MS. We tested this device for the identification of proteins obtained from two-dimensional gel electrophoresis or chromatography. The chip allows the measurement of reproducible retention times that, in association with m/z ratios, was found useful for identifying peptide sequences without ambiguity. A sensitivity increase of a factor of at least 5-fold is obtained compared to the results obtained previously in our laboratory by conventional nanoLC/MS/MS on the same ion trap. We conclude that this recently available microfluidic device can be a valuable tool during biomarker discovery programs, particularly identifying low-abundance proteins.

Chromatography, High Pressure Liquid↗

A microfluidic SELEX prototype.

Aptamers are nucleic acid binding species capable of recognizing a wide variety of targets ranging from small organic molecules to supramolecular structures, including organisms. They are isolated from combinatorial libraries of synthetic nucleic acid by an iterative process referred to as SELEX (Systematic Evolution of Ligands by Exponential Enrichment). Here we describe an automated microfluidic, microline-based assembly that uses LabView-controlled actuatable valves and a PCR machine, and which is capable of the selection and synthesis of an anti-lysozyme aptamer as verified by sequence analysis. The microfluidic prototype described is 1) a simple apparatus that is relatively inexpensive to assemble, making automated aptamer selection accessible to many investigators, and 2) useful for the continued "morphing" of macro-->meso-->microfabricated structures until a convergence to a few functional systems evolves and emerges, partly or completely achieving simpler, smaller and more rapid SELEX applications.

Electrophoresis, Agar Gel↗

Electroporation of cells in microfluidic devices: a review.

In recent years, several publications on microfluidic devices have focused on the process of electroporation, which results in the poration of the biological cell membrane. The devices involved are designed for cell analysis, transfection or pasteurization. The high electric field strengths needed are induced by placing the electrodes in close proximity or by creating a constriction between the electrodes, which focuses the electric field. Detection is usually achieved through fluorescent labeling or by measuring impedance. So far, most of these devices have only concerned themselves solely with the electroporation process, but integration with separation and detection processes is expected in the near future. In particular, single-cell content analysis is expected to add further value to the concept of the microfluidic chip. Furthermore, if advanced pulse schemes are employed, such microdevices can also enhance research into intracellular electroporation.

Animals↗