PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Optical Fibers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Development of an "electroptode" immunosensor: indium tin oxide-coated optical fiber tips conjugated with an electropolymerized thin film with conjugated cholera toxin B subunit.

We demonstrate that it is possible to create surface-conductive fiber optics, upon which may be electropolymerized a biotinylated polypyrrole thin film, which may then be used to affinity coat the fiber with molecular recognition probes. This fiber-optic electroconductive surface modification is done by the deposition of a thin layer of indium tin oxide. Thereafter, biotin-pyrrole monomers are electropolymerized onto the conductive metal oxide surface and then exposed to avidin. Avidin-biotin interactions were used to modify the fiber optics with biotin-conjugated cholera toxin B subunit molecules, for the construction of an immunosensor to detect cholera antitoxin antibodies. The biosensor was tested for sensitivity, nonspecificity, and overall practicality.

Antibodies↗

An innovative strategy for immobilization of receptor proteins on to an optical fiber by use of poly(pyrrole-biotin).

We report an innovative and useful procedure for immobilization of antibodies on to a fiber-optic silica surface. The procedure consists in the chemical oxidation of pyrrole-biotin monomers that are readily deposited as a thin film of poly(pyrrole-biotin) polymer on to the end-face of the fiber. The film was shown to be sufficiently translucent to enable photon coupling within the fiber transducer and its presence was demonstrated by means of fluorescent micrographs of bound rhodamine-labeled avidin. Fiber-optics modified with cholera toxin B subunit molecules were tested for sensitivity, non-specificity, and overall practicality. It was shown that the fiber-optic immuno-assay for the detection of anti-cholera toxin antibody was up to three orders of magnitude more sensitive than the classical enzyme-linked immunosorbent assay (ELISA).

Biotin↗

Multiple capillary DNA sequencer that uses fiber-optic illumination and detection.

An 8-capillary prototype electrophoresis system for DNA sequencing has been constructed. The sequence of 400-450 bases can be obtained from each capillary in less than an hour from sequencing reactions generated with four-color fluorescent terminators. Illumination of each capillary and collection of fluorescence is through individual optical fibers. Resolution of the DNA ladder is through a replaceable sieving matrix of linear polyacrylamide in reusable coated capillaries. Light from an argon ion laser is introduced into a fused biconically tapered fiber-optic splitter, and individual fibers deliver approximately 10 mW of 514 nm light to each of the eight electrophoresis capillaries. Illumination and collection are by fibers normal to the surface of the electrophoresis capillary and at right angle to each other. Illumination by a fiber with low numerical aperture and collection by a fiber with high numerical aperture provides good sensitivity and signal-to-noise ratios without the need for microlenses (limit of detection: 1.5 x 10(-11)M fluorescein analog dye with a signal-to-noise ratio of 2). The eight collection fibers are passed in parallel through holographic filters for Rayleigh rejection and into an imaging spectrograph, which simultaneously displays the full fluorescence spectrum (475-648 nm) from the eight capillaries in parallel on the surface of an intensified charge-coupled device (CCD). The CCD is read out at a rate of 3.4 complete images per second.

DNA↗

Fiber-optic DNA sensor for fluorometric nucleic acid determination.

Single-stranded deoxyribonucleic acid (ssDNA) thymidylic acid icosanucleotides (dT20) were synthesized on the surfaces of derivatized quartz optical fibers to create an optical DNA biosensor. The synthesis made use of an automated solid-phase synthesizer and phosphoramidite synthons. The covalently immobilized oligomers were found to hybridize with complementary ssDNA (cDNA) or ssRNA (cRNA) from solution, and the device was regenerable for multiple cycles of application. Hybridization on optical fibers was detected by the use of the fluorescent DNA stain ethidium bromide (EB). The procedure used hybridization assay techniques and provided a detection limit of 86 ng x mL(-1) cDNA and a sensitivity of 200% fluorescence intensity increase per 100 ng x mL(-1) of cDNA, with one cycle of hybridization analysis requiring 45 min. The sensor has been observed to be regenerable (minimum of five cycles) and to sustain full activity after prolonged storage times (1 year), harsh washing conditions (sonication), and sterilization (autoclaving). The extent of hybridization between the immobilized and complementary nucleic acid strands was determined by UV absorbance thermal denaturation studies wherein all 20 bases on each strand of the nucleic acid were found to be involved in duplex formation.

Biosensing Techniques↗

Mirror magneto-optical trap using circularly polarized light-emitting optical fibers.

A fiber-optic mirror magneto-optical trap (mirror-MOT) that uses a pair of circularly polarized light-emitting optical fibers as an optical access is demonstrated. The fiber is fabricated so that a length of birefringence fiber, designed to be a quarter wave retarder at both wavelengths of 780 and 852 nm, is attached directly onto a polarization-maintaining normal fiber. The polarization states of light emitted from the fibers are sufficiently circular for the operation of a mirror-MOT with 87Rb atoms. The mirror-MOT is able to capture approximately the same number of atoms obtainable with a conventional mirror-MOT. The technique makes it possible to fabricate a compact MOT apparatus by introducing the optical fibers directly into an ultrahigh-vacuum chamber.

Journal Article↗

Fiber optic in vivo imaging in the mammalian nervous system.

The compact size, mechanical flexibility, and growing functionality of optical fiber and fiber optic devices are enabling several new modalities for imaging the mammalian nervous system in vivo. Fluorescence microendoscopy is a minimally invasive fiber modality that provides cellular resolution in deep brain areas. Diffuse optical tomography is a non-invasive modality that uses assemblies of fiber optic emitters and detectors on the cranium for volumetric imaging of brain activation. Optical coherence tomography is a sensitive interferometric imaging technique that can be implemented in a variety of fiber based formats and that might allow intrinsic optical detection of brain activity at a high resolution. Miniaturized fiber optic microscopy permits cellular level imaging in the brains of behaving animals. Together, these modalities will enable new uses of imaging in the intact nervous system for both research and clinical applications.

Animals↗

PRDX1 as a novel urinary biomarker for bladder cancer: Development of an integrated fiber optic sensing platform.

In this study, integrated proteomic and transcriptomic analyses identified peroxiredoxin 1 (PRDX1) as a novel urinary biomarker for bladder cancer (BC). PRDX1 was significantly upregulated in BC tissues and was associated with poorer overall survival. In vitro experiments further demonstrated that PRDX1 promotes malignant phenotypes of BC cells, including proliferation, migration, and invasion. Silencing PRDX1 in BC cells significantly reduced the invasiveness and proliferation ability.To address the clinical need for rapid and non-invasive detection, we developed an innovative optical fiber biosensor based on surface plasmon resonance (SPR) technology for the quantitative detection of urinary PRDX1. The biosensor exhibited excellent analytical performance, including high sensitivity (limit of detection: 0.06 ng/mL), a wide linear range (0-25 ng/mL), rapid response (∼14 s), as well as good stability and selectivity. In clinical validation involving 97 BC patients and 30 healthy controls, the biosensor demonstrated outstanding diagnostic performance, with an area under the receiver operating characteristic curve (AUC) of 0.91 and an overall diagnostic accuracy of 86.6%, outperforming conventional enzyme-linked immunosorbent assay (ELISA). Collectively, this study not only identifies PRDX1 as a promising biomarker for non-invasive diagnosis and prognostic evaluation of BC, but also establishes an efficient SPR-based optical fiber sensing platform, providing new insights into both clinical detection and the functional role of PRDX1 in BC progression.

Humans↗

Laser recannalization of atheromatous vessels using fiber optics.

A laser endoscope was devised using optic fibers in order to provide a means of visualization and removal of atheromatous plaques from arteries in cadavers and experimental animals. Atheromatous plaques were satisfactorily lased off in a few seconds, although contraction of lased vessels was observed. A self-focusing fiber was shown to provide laser access to and visualization of the body via a single optic fiber of feasibly less than 0.2 mm diameter.

Angioplasty, Balloon↗

An evanescent wave biosensor--Part II: Fluorescent signal acquisition from tapered fiber optic probes.

A biosensor was developed using antibodies, fluorescence and the evanescent wave to detect antigen binding at the surface of an optical fiber. Cladding was removed from the core along the distal end of a step-index optical fiber, and recognition antibodies were immobilized on the declad core to form the probe sensing region. Immersing the declad probe in aqueous solution creates a V-number mismatch between the immersed probe and the clad fiber. Probes created with reduced sensing region radius exhibited improved response by decreasing the V-number mismatch. Tapering the radius of this region has further improved probe response. Ray tracing analysis of the tapered probe demonstrated that the evanescent wave penetration depth increases along the length of the taper. Experiments correlating position of refraction along the taper with launch angle at the proximal end were realized in the ray tracing model. An evanescent wave immunoassay was performed with a series of the tapered fiber probes, each tapered from the fiber core radius (100 microns) to different end radii. An end radius of 29 microns was found to produce maximal signal from the tapered probe. Factors leading to the determination of the optimized probe are discussed.

Biosensing Techniques↗

Miniature fiber-optic pressure sensor with a polymer diaphragm.

The fabrication and experimental investigation of a miniature optical fiber pressure sensor for biomedical and industrial applications are described. The sensor measures only 125 microm in diameter. The essential element is a thin polymer diaphragm that is positioned inside the hollow end of an optical fiber. The cavity at the fiber end is made by a simple and effective micromachining process based on wet etching in diluted HF acid. Thus a Fabry-Perot interferometer is formed between the inner fiber-cavity interface and the diaphragm. The fabrication technique is described in detail. Different sensor prototypes were fabricated upon 125 microm-diameter optical fiber that demonstrated pressure ranges from 0 to 40 and from 0 to 1200 kPa. A resolution of less than 10 Pa was demonstrated in practice. The fabrication technique presented facilitates production of simple and low-cost disposable pressure sensors by use of materials with that ensure the required biocompatibility.

Journal Article↗

Free cholesterol fiber-optic biosensor for serum samples with simplex optimization.

An optical fiber biosensor for free cholesterol monitoring in serum samples is described. Silicone-entrapped tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) complex, the luminescence of which is sensitive to oxygen changes, is used as an optical transducer of the oxidation of cholesterol by cholesterol oxidase. The biocatalyst is entrapped in a graphite powder layer deposited onto the dyed silicone film. Optimization of some interdependent chemical variables which affect the performance of the biosensor has been achieved by application of a super-modified simplex method. The dynamic range of the biosensing membranes is found to be 0.15-3.0 mM of free cholesterol. Studies of the reproducibility, stability and interferences of the device, as well as the application of the sensor to measurements in serum samples, are reported. Simplex optimization has proven to be a very useful tool in the search for the optimal conditions for performing analyses with the optical fiber biosensor.

Biosensing Techniques↗

A fiber-optic evanescent wave DNA biosensor based on novel molecular beacons.

We have prepared a novel optical fiber evanescent wave DNA biosensor using a newly developed molecular beacon DNA probe. The molecular beacons (MB) are oligonucleotide probes that become fluorescent upon hybridization with target DNA/RNA molecules. Biotinylated MBs have been designed and immobilized on an optical fiber core surface via biotin-avidin or biotin-streptavidin interactions. The DNA sensor based on a MB does not need labeled analyte or intercalation reagents. It can be used to directly detect, in real-time, target DNA/RNA molecules without using competitive assays. The sensor is rapid, stable, highly selective, and reproducible. We have studied the hybridization kinetics of the immobilized MB by changing the ionic strength of the hybridization solution and target DNA concentration. Our result shows divalent cations play a more important role than monovalent cations in stabilizing the MB stem hybrids and in accelerating the hybridization reaction with target DNA/RNA molecules. The concentration detection limit of the MB evanescent wave biosensor is 1.1 nM. The MB DNA biosensor has been applied to the analysis of specific gamma-actin mRNA sequences amplified by polymerase chain reaction.

Actins↗

Fiber-optic biosensors--an overview.

This article reviews progress and developments during the past five years in the field of optical fiber biosensors. Because of the expense and time constraints associated with modern laboratory analysis, there is a growing need for real-time, low-cost technology that can be used industrially, environmentally, and clinically, and to monitor food processing. Miniaturization, integrated systems, and multianalyte determination have become key aspects of sensor development and efforts in this direction will also be discussed, with some pointers to likely directions of future research in the area. The review will provide information about the analytical characteristics and applications of fiber-optic biosensors classified depending on the biorecognition element employed - enzymes, whole cells, antibodies, nucleic acids, and biomimetic polymers.

Biosensing Techniques↗

Oxygen optrode for use in a fiber-optic glucose biosensor.

An optical fiber oxygen sensor, based on the dynamic quenching of the luminescence of tris(1,10-phenanthroline)-ruthenium(II) cation by molecular oxygen, is presented. The complex is adsorbed onto silica gel, incorporated in a silicone matrix possessing a high oxygen permeability, and placed at the tip of the optical fiber. Oxygen has been monitored continuously in the 0-750 Torr range, with the detection limit being as low as 0.7 Torr. The device has been applied to the development of a fast responding and highly sensitive fiber-optic glucose biosensor based on this highly sensitive oxygen transducer. The sensor relates oxygen consumption (as a result of enzymatic oxidation) to glucose concentration. The enzyme is immobilized on the surface of the oxygen optrode; carbon black is used as an optical isolation in order to prevent ambient light and sample fluorescence to interfere. Measurements have been performed in a flow-through cell in air-equilibrated glucose standard solutions of pH 7.0. The effects of enzyme immobilization procedures (including enzyme immobilization on carbon black) as to response times (around 6 min), analytical ranges (0.06-1 mM glucose), reproducibility in sensor construction, and long-term stability have been studied as well.

Biosensing Techniques↗

Fiber optic probe cytometer.

An optical fiber probe is used to both excite and collect fluorescence from a suspension of cells. The configuration of the probe is such that one or a few cells are sensed at a time, with a convenient cell concentration. With fluorescently labeled antibodies to cellular antigens, the fiber optic cytometer is able to identify the presence of a specific set of cells with high sensitivity.

ABO Blood-Group System↗

Capillary-electrode alignment by an optical-fiber connector for amperometric detection in capillary electrophoresis.

We describe here an electrochemical cell ideal for routine analysis of CE-EC experiments (capillary electrophoresis coupled with electrochemical detection). The cell was modified from a fiber-optic connector, named MT, which allowed frequent change and fast alignment between a pair of 4-strand fiber ribbons. The relative standard deviations of the current response and migration time for 100 microM dopamine were, respectively, 3.7 and 0.5% in five repetitive routines of disconnecting, polishing, and assembling the CE cell. The time required for alignment of the separation capillary and the working electrode was < 10 s, once all components were assembled in an MT fiber-optic plug. These features enabled CE-EC users to polish the working electrode and reassemble the EC cell as in HPLC-EC. However, to accommodate the channel dimensions of the commercially available MT, a special order capillary with outer diameter of 125 microm is necessary at this stage.

Catecholamines↗

A novel FRET-based optical fiber biosensor for rapid detection of Salmonella typhimurium.

A biosensor that is portable and permits on-site analysis of samples would significantly reduce the large economical burden of food products recalls. A fiber optic portable biosensor utilizing the principle of fluorescence resonance energy transfer (FRET) was developed for fast detection of Salmonella typhimurium (S. typhimurium) in ground pork samples. Labeled antibody-protein G complexes were formed via the incubation of anti-Salmonella antibodies labeled with FRET donor fluorophores (Alexa Fluor 546) and protein G (PG) labeled with FRET acceptor fluorophores (Alexa Fluor 594). Utilizing silanization, the labeled antibodies-PG complexes were then immobilized on decladded, tapered silica fiber cores to form the evanescent wave-sensing region. The biosensors were tested in two different solutions: (1) PBS doped with S. typhimurium and (2) homogenized pork sample with S. typhimurium. The fiber probes tested in a S. typhimurium doped phosphate buffered solution demonstrated the feasibility of the biosensor for detecting S. typhimurium as well as determined the optimal packing density of the labeled antibody-PG complexes on the surface of fibers. The results showed that a packing density of 0.033 mg/ml produced the lowest limit of detection of 10(3)cells/ml with 8.2% change in fluorescence. The fiber probes placed in homogenized pork samples inoculated with S. typhimurium showed a limit of detection of 10(5)CFU/g with a 6.67% in fluorescence within a 5-min response time. These results showed that the FRET-based fiber optic biosensor can become a useful analytical tool for detection of S. typhimurium in real food samples.

Animals↗

Optical-fiber-based Mueller optical coherence tomography.

An optical-fiber-based multichannel polarization-sensitive Mueller optical coherence tomography (OCT) system was built to acquire the Jones or Mueller matrix of a scattering medium, such as biological tissue. For the first time to our knowledge, fiber-based polarization-sensitive OCT was dynamically calibrated to eliminate the polarization distortion caused by the single-mode optical fiber in the sample arm, thereby overcoming a key technical impediment to the application of optical fibers in this technology. The round-trip Jones matrix of the sampling fiber was acquired from the reflecting surface of the sample for each depth scan (A scan) with our OCT system. A new rigorous algorithm was then used to retrieve the calibrated polarization properties of the sample. This algorithm was validated with experimental data. The skin of a rat was imaged with this fiber-based system.

Animals↗