PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “dynamic range”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

The influences of ambiguity phase aberration profiles on focusing quality in the very near field part II: dynamic range focusing on reception.

In Part I of this work, the influences of ambiguity phase aberration profiles, including constant, tilted, and quadratic profiles, on focusing quality have been quantitatively analyzed with the very near field approximation for single range focusing on transmission. In this paper, their influences are analyzed in a very different situation: dynamic range focusing on reception, which is commonly used in medical ultrasound imaging for beam formation on reception. It is shown that the results for dynamic range focusing on reception are dramatically different from those for single range focusing on transmission. For example, constant phase aberration profiles are harmless to focusing quality for single range focusing on transmission but become harmful for dynamic range focusing on reception. The analysis also shows that, compared with single range focusing on transmission, dynamic range focusing on reception is much more sensitive to ambiguity phase aberration profiles, which have adverse effects on focusing quality even in the near field and far field. These significant differences are caused by the fundamental differences between single range focusing and dynamic range focusing as well as between transmission and reception. Numerical and simulation results are also derived to test the correctness and accuracy of the theoretical results.

Algorithms↗

Elastographic dynamic range expansion using variable applied strains.

In elastography, we want to image the entire range of stiffnesses of the elastic components found in inhomogeneous tissues. In order to achieve this, the elastographic dynamic range should equal the entire stiffness dynamic range in the target. Various sources of noise limit the dynamic range of elastography. The recently-defined strain filter concept offers an analytical and graphical way of observing these limitations. In this paper, we describe a method that achieves the expansion of the elastographic dynamic range. It involves the application of variable strains in combination with selective storage of strain data that have optimal elastographic signal-to-noise ratios. This expands the current dynamic range of elastography by orders of magnitude when compared to single compression elastography. The process is explained theoretically using the strain filter framework, and 1 D as well as 2D tissue simulations are used to corroborate the theory.

Algorithms↗

Dynamic-range compression in surface-coil MRI.

The large dynamic range in signal intensity present in MR surface-coil images makes proper windowing and photography difficult. By removing the low-spatial frequency information caused by variations in surface-coil field intensity from the high-spatial frequency information containing the image data, a considerable compression of this dynamic range of signal intensity is possible. To accomplish this, a technique was implemented on a digital computer for use with MR surface-coil image data. The compression was done as a postprocessing option after the patient scan had been completed and therefore did not alter actual scan times. Although the image signal-to-noise was not altered, the ease of photography for most images was improved. Thus, digital dynamic-range compression is a practical technique to aid in surface-coil MRI studies.

Adenocarcinoma↗

Dynamic range control processing of digital chest images. A clinical evaluation.

PURPOSE: The clinical usefulness of an advanced image-processing system called "dynamic range control processing" was investigated, with which selected parts of the dynamic range of digital chest images could be controlled. MATERIAL AND METHODS: A comparative study of 3 different post-processed formats of storage phosphor (SR) images was performed in 35 patients with abnormalities in the chest. The 3 formats were SR images with standard mode (SR-standard), SR images with strong edge-enhancement (SR-enhanced), and dynamic range controlled SR images (SR-controlled). RESULTS: For lung abnormalities, there was no difference among the 3 SR image formats. For normal mediastinal structures and lung abnormalities covered by the heart or diaphragm, SR-controlled and SR-enhanced images were significantly superior to SR-standard images, while no difference was found between SR-controlled and SR-enhanced images except for the trachea and bony structures. CONCLUSION: Dynamic range control processing appears to be a useful method for displaying SR chest images with an extremely wide dynamic range.

Adolescent↗

Changes in responses of wide dynamic range neurons in the spinal dorsal horn after dorsal root or dorsal root ganglion compression.

STUDY DESIGN: The electrophysiologic responses of wide dynamic range neurons in the spinal dorsal horn by compression of the dorsal root or of the dorsal root ganglion were investigated. OBJECTIVES: This study identified differences between the compression of the dorsal root against the compression of the dorsal root ganglion by examining the responses of wide dynamic range neurons. SUMMARY OF BACKGROUND DATA: The wide dynamic range neurons studied were known to be excited by primary afferent fibers, not only combined A delta and C-nociceptive fibers but also low threshold mechanoreceptive A beta fibers and A delta fibers of down hairs. Thus, the wide dynamic range neurons are classified as nociceptive neurons. METHODS: Extracellular activities of 32 wide dynamic range neurons were recorded from the laminae 4-6 of the seventh lumbar cord in anesthetized cats. A microvessel clip (40 g) was applied to compress the dorsal root or the dorsal root ganglion. RESULTS: Dorsal root compression produced only an initial burst (about 10-40 seconds). Prolonged repetitive firings were rarely maintained. In contrast, dorsal root ganglion compression resulted in a maintained repetitive firing throughout the period of compression. After release of compression of the dorsal root and the dorsal root ganglion, responses to brushing were facilitated, and the low threshold center of the receptive field expanded. CONCLUSIONS: These findings are consistent with the previous report that the radicular pain associated with a herniated intervertebral disc initially results from compression of the dorsal root ganglion.

Animals↗

Adaptive dynamic range optimization (ADRO): a digital amplification strategy for hearing aids and cochlear implants.

Adaptive dynamic range optimization (ADRO) is an amplification strategy that uses digital signal processing techniques to improve the audibility, comfort, and intelligibility of sounds for people who use cochlear implants and/or hearing aids. The strategy uses statistical analysis to select the most information-rich section of the input dynamic range in multiple-frequency channels. Fuzzy logic rules control the gain in each frequency channel so that the selected section of the dynamic range is presented at an audible and comfortable level. The ADRO processing thus adaptively optimizes the dynamic range of the signal in multiple-frequency channels. Clinical studies show that ADRO can be fitted easily to all degrees of hearing loss for hearing aids and cochlear implants in a direct and intuitive manner, taking the preferences of the listener into account. The result is high acceptance by new and experienced hearing aid users and strong preferences for ADRO compared with alternative amplification strategies. The ADRO processing is particularly well suited to bimodal and hybrid stimulation which combine electric and acoustic stimulation in opposite ears or in the same ear, respectively.

Algorithms↗

HDR VolVis: high dynamic range volume visualization.

In this paper, we present an interactive high dynamic range volume visualization framework (HDR VolVis) for visualizing volumetric data with both high spatial and intensity resolutions. Volumes with high dynamic range values require high precision computing during the rendering process to preserve data precision. Furthermore, it is desirable to render high resolution volumes with low opacity values to reveal detailed internal structures, which also requires high precision compositing. High precision rendering will result in a high precision intermediate image (also known as high dynamic range image). Simply rounding up pixel values to regular display scales will result in loss of computed details. Our method performs high precision compositing followed by dynamic tone mapping to preserve details on regular display devices. Rendering high precision volume data requires corresponding resolution in the transfer function. To assist the users in designing a high resolution transfer function on a limited resolution display device, we propose a novel transfer function specification interface with nonlinear magnification of the density range and logarithmic scaling of the color/ opacity range. By leveraging modern commodity graphics hardware, multiresolution rendering techniques and out-of-core acceleration, our system can effectively produce an interactive visualization of large volume data, such as 2,048(3).

Algorithms↗

[Determination of the dynamic range of digital X-ray receivers].

Specific features of determination of the dynamic range of digital X-ray receivers are considered. Various procedures for dynamic range determination are compared. The minimal permissible and optimal dynamic ranges are estimated.

Radiographic Image Enhancement↗

The dynamic range of biologic functions and variation of many environmental cues may be declining in the modern age: implications for diseases and therapeutics.

We hypothesize that declining dynamic range and variation of environmental cues may contribute to health dysfunctions, and that judicious expansion of biologic dynamic ranges may be beneficial. Three disparate examples involving the endocrine, autonomic, and musculoskeletal systems are discussed. Daytime sheltering, optical shading, and nighttime use of artificial light may reduce circadian luminal variation. The resulting melatonin alterations may contribute to systemic dysfunctions. Loss of temporal variation of other hormones may contribute to biologic dysfunctions, especially those involving the hypothalamic-pituitary axis. Reduced variation of physical exertion, environmental stressors, and thermal gradients that characterize modern lifestyles may reduce the autonomic dynamic range resulting in lowered heart rate variability and a myriad of systemic dysfunctions. The health benefits of activities such as exercise, meditation, acupuncture, coitus, and laughter may operate through increasing autonomic variability. Reduced physical exertion also accounts for declining dynamic range of musculoskeletal function. The resulting muscle atrophy, fat infiltration, and sarcomere shortening may not only have deleterious local effects, but may also be involved in systemic metabolic dysfunctions such as insulin resistance. The extent to which our endogenous systems rely on environmental variation for self-tuning and the impact that under-utilization of compensatory mechanisms has on biologic function are not well understood. Modern therapeutic approaches generally result in reversion to the mean of physiologic functions and may buffer against variation. For example, beta-blockers are given to reduce adrenergic excess, insulin to treat insulin insufficiency, serotonin-reuptake inhibitors for depression, and refractive lenses for myopia. By undermining the demand for native compensatory functions, such therapeutic strategies may actually impair future ability to respond to biologic disequilibria. Generalizing from these observations, we anticipate benefits of therapeutic and lifestyle approaches that expand, rather than reduce, the dynamic range of many biologic experiences.

Animals↗

Alzheimer disease constricts the dynamic range of spatial attention in visual search.

A cued visual search task was used to examine the dynamic range over which spatial attention affects target identification during visual search. Precues varied in validity (valid, invalid, or neutral) and in precision (cue size) of target localization. Participants were "young-old" (65-74 years) and "old-old" (75-85 years) elderly adults and individuals in the mild stage of dementia of the Alzheimer type (DAT). For all participants, search was speeded as the precision with which a precue surrounding the location of a subsequently appearing target increased (precue size decreased). The cue size effect was evident in both feature and conjunction search, but was greatly reduced in both old-old and DAT groups compared to the young-old. However, whereas all non-demented adults showed a progressive modulation of search efficiency over the entire range of cue sizes, the dynamic range of spatial attention was restricted to the most precise cue in the DAT group. The restriction in the dynamic range of spatial attention may represent an underlying component of the impairment in perceptual and memory functioning found in early-stage DAT.

Adult↗

Effects of dynamic range and amplitude mapping on phoneme recognition in Nucleus-22 cochlear implant users.

OBJECTIVE: To determine the consequences for phoneme recognition of errors in setting threshold and loudness levels in cochlear implant listeners using a 4-channel continuous interleaved sampling (CIS) speech processor. DESIGN: Three Nucleus-22 cochlear implant listeners, who normally used the SPEAK speech processing strategy participated in this study. An experimental 4-channel CIS speech processor was implemented in each listener as follows. Speech signals were band-pass filtered into four broad frequency bands and the temporal envelope of the signal in each band was extracted by half-wave rectification and low-pass filtering. A power function was used to convert the extracted acoustic amplitudes to electric currents. The electric currents were dependent on the exponent of the mapping power function and the electrode dynamic range, which was determined by the minimum and maximum stimulation levels. In the baseline condition, the minimum and maximum stimulation levels were defined as the psychophysically measured threshold level (T-level) and maximum comfortable level (C-level). In the experimental conditions, the maximum stimulation levels were fixed at the C-level and the dynamic range (in dB) was changed by varying the minimum stimulation levels on all electrodes. This manipulation simulates the effect of an erroneous measurement of the T-level. Phoneme recognition was obtained as the dynamic range of electrodes was changed from 1 dB to 20 dB and as the exponent of the power-law amplitude mapping function was changed from 0.1 to 0.4. RESULTS: For each mapping condition, the electric dynamic range had a significant, but weak effect on vowel and consonant recognition. For a strong compression (p = 0.1), best vowel and consonant scores were obtained with a large dynamic range (12 dB). When the exponent of the mapping function was changed to 0.2 and 0.4, the dynamic range producing the highest scores decreased to 6 dB and 3 dB, respectively. CONCLUSIONS: Phoneme recognition with a 4-channel CIS strategy was only mildly affected by large changes in both electric threshold and loudness mapping. Errors in threshold by a factor of 2 (6 dB) and in the loudness mapping exponent by a factor of 2 were required to produce a significant decrease in performance. In these extreme conditions, the effect of the electric dynamic range on phoneme recognition could be due to two independent factors: abnormal loudness growth and a reduction in the number of discriminable intensity steps. The decrease in performance caused by a reduced electric dynamic range can be compensated by a more expansive power-law mapping function, as long as the number of discriminable intensity steps is moderately large (e.g., >8).

Acoustic Stimulation↗

An analysis of the dynamic range and linearity of an infrared DNA sequencer.

We are currently developing genotyping software and protocols for use on the Li-Cor model 4000(L) infrared fluorescence DNA sequencers. During the development of the genotyping software it became apparent that the potential dynamic range of the instrument was not being realized when the data collection parameters were optimized to produce a high-contrast image on the computer screen. In particular, we were unable to obtain peaks with signal to noise (S/N) greater than about 30:1 and the stronger peaks often saturated the detector. Because the numerical dynamic range available in 16-bit data collection mode exceeds 65000, our limited dynamic range of about 30 in actual data was somewhat puzzling. Hence, we undertook a study to explore the dynamic range and linearity of the Li-Cor DNA sequencer in order to minimize background fluorescence and noise as well as maximize the available S/N. Data is presented on the background and noise using different polyacrylamide gel mixes with various signal gain and offset values, and the relative contribution of the glass, gel and instrumentation to the background fluorescence is discussed. Based on these results, optimum gain and offset values were determined that maintain the background fluorescence at approximately 1-2% of the maximum dynamic range with a minimum amount of noise. Using these optimized values, we determined the detection system is linear over three orders of magnitude by titrating known quantities of an infrared fluorophore-labeled primer. In addition, we were able to detect approximately 15.2 amoles of labeled primer. The results provided by this study establish a set of guidelines for evaluating how to set the signal gain and offset in order to minimize the background and maximize the S/N and dynamic range of the Li-Cor sequencer.

DNA↗

Dynamic range compression in MRI by means of a nonlinear gradient pulse.

In current magnetic resonance imaging (MRI), valuable information must often be discarded because the NMR signal has greater dynamic range than the analog-to-digital converter (ADC) hardware. Typically, a small set of high-intensity data points near the center of the spin echo is responsible for most of the MRI data dynamic range. We predict that it is possible to reduce the dynamic range of the MRI spin echo by incorporating an identical nonlinear gradient pulse into each repetition of the imaging pulse sequence, prior to data sampling. This pulse converts the phase distribution of the subject, ordinarily a linear function of image coordinates, into a nonlinear function. A nonlinear phase distribution can have a negligible impact on image magnitude and yet a profound impact on spin-echo magnitude. Given a nonlinear phase distribution, there will no longer be a single data point at which all of the protons have an identical phase (the echo center). Instead, the protons become phase coherent on a piecemeal basis, the echo peak is smoothed out, and its maximum amplitude and dynamic range are greatly diminished. Using gradient pulses of quadratic spatial variation, we estimate that maximum echo amplitude and dynamic range can be reduced in most cases by an order of magnitude.

Analog-Digital Conversion↗

Speech dynamic range and its effect on cochlear implant performance.

This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50-dB distribution of speech envelope levels. Phoneme recognition was also obtained in ten CLARION implant users as a function of the input dynamic range from 10 to 80 dB in 10-dB steps. Acoustic amplitudes within a specified input dynamic range were logarithmically mapped into the 10-20-dB range of electric stimulation typically found in cochlear-implant users. Consistent with acoustic data, the perceptual data showed that a 50-60-dB input dynamic range produced optimal speech recognition in these implant users. The present results indicate that speech dynamic range is much greater than the commonly assumed 30-dB range. A new amplitude mapping strategy, based on envelope distribution differences between consonants and vowels, is proposed to optimize acoustic-to-electric mapping of speech sounds. This new strategy will use a logarithmic map for low-frequency channels and a more compressive map for high-frequency channels, and may improve overall speech recognition for cochlear-implant users.

Adult↗

Computational modeling of a new fluorescent biosensor for caspase proteolytic activity improves dynamic range.

The class of fluorescence resonance energy transfer (FRET) protein biosensors that are useful for measuring protease activity is composed of a tandem fusion of yellow fluorescent protein (YFP), a cleavage recognition sequence, and cyan fluorescent protein (CFP). The dynamic range of these FRET-based protein biosensors is often weak, but applications such as high throughput drug screening require stronger dynamic ranges. Using the biosensor for the caspase-3 protease as an example, here we showed a computational approach to improve the FRET dynamic range based on the atomic structure of caspase-3 bound to its inhibitor. This result was verified from our experiments where the FRET dynamic range improved by at least 60% on average in both in vitro and in vivo contexts. In concept, the same strategy can be applied to improve dynamic range of other FRET-based protein biosensors for protease activity where there exist solved atomic structures for protein complexes.

Caspase 3↗

Comparison of linear gain and wide dynamic range compression hearing aid circuits II: aided loudness measures.

OBJECTIVES: The goal of this study was to test the theoretical advantages of a single-channel wide dynamic range compression (WDRC) circuit fitted using the DSL method for increased dynamic range and normalized loudness growth. DESIGN: Ten adolescents and young adults with moderate to severe sensorineural hearing loss were fitted monaurally with the Siemens Viva 2 Pro behind-the-ear instrument set to DSL 4.0 targets for both linear gain and WDRC processing. Threshold, upper limit of comfort and loudness growth were measured in the unaided, linear gain and WDRC conditions for warble tones, environmental sounds and speech. Twelve adult listeners with normal hearing also were tested monaurally in the unaided condition to provide normative data for comparison purposes. RESULTS: The WDRC hearing aid provided a greater input dynamic range than the linear circuit for all stimuli. The dynamic range was normalized for more subjects with the WDRC than the linear hearing aid. In addition, exponential loudness growth functions fitted to the loudness growth data showed that, on average, loudness growth was more normalized with the WDRC hearing aid fitted to DSL[i/o] targets than the linear hearing aid fitted to DSL[i/o] targets. CONCLUSIONS: WDRC processing, fitted using the DSL[i/o] method, has potential applications in hearing aid fittings for listeners with moderate to severe hearing loss because it provides an audible, comfortable and tolerable amplified signal across a wider range of inputs than linear gain processing, without the need for volume control adjustments.

Adolescent↗

Dynamic range and language abilities in deaf adolescents.

The relationship between language abilities and dynamic range was studied in two groups of significantly deaf adolescents. One group (N = 21) attended a school for the deaf, and the other (N = 23) consisted of either students in regular schools or those attending units for the deaf within regular schools. Two measures of dynamic range were obtained, and language ability was defined by performance on a syntactic abilities test. Acoustic reflexes were also obtained and the relationship to language abilities was determined. Dynamic range was observed to be a highly significant predictor of language score within the deaf school group, but did not relate to language score within the regular school group. Presence or absence of the acoustic reflex bore no apparent relationship to language ability.

Adolescent↗

Effect of slow-acting wide dynamic range compression on measures of intelligibility and ratings of speech quality in simulated-loss listeners.

The purpose of this study was twofold: (a) to determine the extent to which 4-channel, slow-acting wide dynamic range amplitude compression (WDRC) can counteract the perceptual effects of reduced auditory dynamic range and (b) to examine the relation between objective measures of speech intelligibility and categorical ratings of speech quality for sentences processed with slow-acting WDRC. Multiband expansion was used to simulate the effects of elevated thresholds and loudness recruitment in normal hearing listeners. While some previous studies have shown that WDRC can improve both speech intelligibility and quality, others have found no benefit. The current experiment shows that moderate amounts of compression can provide a small but significant improvement in speech intelligibility, relative to linear amplification, for simulated-loss listeners with small dynamic ranges (i.e., flat, moderate hearing loss). This benefit was found for speech at conversational levels, both in quiet and in a background of babble. Simulated-loss listeners with large dynamic ranges (i.e., sloping, mild-to-moderate hearing loss) did not show any improvement. Comparison of speech intelligibility scores and subjective ratings of intelligibility showed that listeners with simulated hearing loss could accurately judge the overall intelligibility of speech. However, in all listeners, ratings of pleasantness decreased as the compression ratio increased. These findings suggest that subjective measures of speech quality should be used in conjunction with either objective or subjective measures of speech intelligibility to ensure that participant-selected hearing aid parameters optimize both comfort and intelligibility.

Acoustic Stimulation↗