PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “dynamic range”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Dynamic range relations for auditory primary afferents.

Dynamic range is one of four attributes typically assigned to the plot of firing rate vs. stimulus level of an auditory primary afferent. Dynamic range is generally understood to be the contiguous range of sound-pressure-level over which the neuron can indicate some small level change. Typically, however, dynamic range has been quantified as the width in decibels between the endpoints of the rate-level plot, which is not a measure of sensitivity to level change. A sensitivity measure is provided here by first deriving an equation for the intensity-difference limen (DL) in terms of attributes of the rate-level curve. The result is a generally U-shaped curve of DL vs. level. Any given criterion DL corresponds to a horizontal line cutting the DL curve at two points, with the separation in decibels between those points providing a dynamic range for that DL criterion. Plotting the dynamic ranges vs. the respective DLs yields a dynamic range curve. These were made for 62 afferents from the cat. The dynamic ranges of sloping-saturating rate-level plots do not exceed those for sigmoidal plots until the DL criterion reaches 50 dB, supporting the conclusion of Palmer and Evans [Cochlear fibre rate-intensity functions: no evidence for basilar membrane nonlinearities, Hearing Research 2 (1980) 319-326] that sloping saturation is not a reflection of cochlear nonlinearity.

Acoustic Stimulation↗

Sensitive high-resolution white-light Schlieren technique with a large dynamic range for the investigation of ablation dynamics.

We developed a modified Hoffman contrast technique with a 12 ns pulsed incoherent extended white-light source that enables an easily interpretable visualization of ablation plumes with high resolution, a large dynamic range, and color information. By comparison, a conventional dark-field setup with a slitlike laser light source provides large sensitivity but a small dynamic range, and it is difficult to interpret the filtered images.

Algorithms↗

Estimating auditory neuronal dynamic range using a fitted function.

To obtain the dynamic range of an auditory afferent, the neuron's firing rate is plotted versus stimulus level, and the dynamic range is taken as the difference between the threshold for evoked firing, and the level at which firing rate saturates. Those dynamic range endpoints are typically defined in terms of the neuron's spontaneous firing rate and its maximum firing rate, according to a plurality of schemes, each of which depends on user-chosen sets of numerical criteria. The dynamic ranges predicted by some of these schemes are compared for the first time, and the resulting estimates can differ by a factor of 2. A step can be taken towards standardizing the measurement of neuronal dynamic range, if dynamic range is incorporated into a rate-level function as a parameter. To build this function, it is first assumed that the neuron's rate-level response reaches half its maximum at a level half-way between the threshold and the level at saturation, i.e. at threshold plus half the dynamic range. Then the firing rates at threshold and at threshold plus dynamic range are defined according to the most popular of the endpoint schemes. The resulting equation produces credible estimates of neuronal properties when fitted, and correctly predicts the behavior of the slope of the empirical rate-level plot [McGee, 1983. M.S. thesis, Creighton University; Ohlemiller et al., 1991. J. Acoust. Soc. Am. 90, 274-287]. Thus, despite not being deterministic, the new equation has remarkable predictive power. When two of the rate-level functions are added and weighted, the resulting equation fits sloping-saturating data better than any functions presently employed.

Animals↗

Auditory dynamic range derived from the mean rate-intensity function in the cat.

Loudness change is perceived over a far greater range than the discrimination range of single afferents-the "dynamic range problem" [1]. However, earlier neural count models have not fully considered how variability in the dynamic ranges, thresholds, spontaneous rates, and saturation rates of these afferents may affect overall dynamic range. In the present model, all four of these characteristics appear in a logistic rate-intensity function that fits well with sigmoidally firing cat neurons (a double logistic fits well with sloping-saturating units). These equations were averaged statistically over parameter distributions for each of three spontaneous rate groups. An average over these groups (weighted by relative group size) was used to compute discriminability for a patch of basilar membrane. The upper limit on dynamic range for a patch one critical band wide at 8 kHz was 89 dB SPL, less than implied by psychophysics [2]. A two-channel model extended the upper limit by only 3 dB, and splitting the population into four channels did not improve this limit. Seven channels, optimally combined, provided a dynamic range nearly equal to that of an ideal observer that treats each fiber as a separate channel. Moreover, the contribution of sloping-saturating units to discriminability was not as great as popularly expected. Changing the variances of fiber dynamic ranges did not strongly affect overall dynamic range in any of these computations. In sum, when the distributions of neural parameters are taken into account, local pooling can greatly mitigate the "dynamic range problem."

Animals↗

Dynamic range requirements in digital mammography.

The dynamic range and the number of gray levels, gamma s, required for digital mammography has been evaluated using an energy transport model. The effects of molybdenum (Mo) and tungsten (W) target spectra and the energy-dependent attenuation by elemental filters, breast tissue, and a phosphor screen were included in the model. For detectors with ideal optical coupling and no inherent detector noise, 3,100 gray levels are discernable (requiring 12 bits per pixel), assuming a 40 kVp, W target spectrum (1.0 mm A1 filtration), a mean glandular dose to a 5 cm thick breast of 0.6 mGy, and an ideal observer with a 5 mm diam viewing aperture. The effects of inherent detector noise and realistic coupling efficiency on gamma s were also examined. For the 40 kVp, W spectrum, a detector with total coupling efficiency of 16 electrons (e-) per x-ray interaction and a dynamic range of 3000 (maximum carrier signal of 1.93 x 10(5) e-/pixel and inherent detector noise of 64 e- pixel) would decrease the number of gray levels that could be resolved by only 2% compared to a detector with ideal coupling and no inherent noise. A detector with a total coupling efficiency of 2.0 electrons per x-ray interaction and a dynamic range of 240 (maximum carrier signal 2.41 x 10(4) e-/pixel and inherent detector noise of 100 e-/pixel) would reduce the number of gray levels by 26% for the 40 kVp spectrum. On the basis of dynamic range, W spectra are preferable for digital mammography, since Mo spectra yielding the same signal-to-noise ratio require a detector with dynamic range twice as large, and with a 30% greater saturation signal. When no scatter rejection method is used, scattered radiation over a 254 cm2 imaging field reduces the number of discernable gray levels by 23% for a 5 cm thick breast and 34% for an 8 cm thick breast.

Breast↗

Energy, range dynamics and global species richness patterns: reconciling mid-domain effects and environmental determinants of avian diversity.

Spatial patterns of species richness follow climatic and environmental variation, but could reflect random dynamics of species ranges (the mid-domain effect, MDE). Using data on the global distribution of birds, we compared predictions based on energy availability (actual evapotranspiration, AET, the best single correlate of avian richness) with those of range dynamics models. MDE operating within the global terrestrial area provides a poor prediction of richness variation, but if it operates separately within traditional biogeographic realms, it explains more global variation in richness than AET. The best predictions, however, are given by a model of global range dynamics modulated by AET, such that the probability of a range spreading into an area is proportional to its AET. This model also accurately predicts the latitudinal variation in species richness and variation of species richness both within and between realms, thus representing a compelling mechanism for the major trends in global biodiversity.

Animals↗

Dynamic range of the contralateral stapedius reflex in cochlear implant patients.

The dynamic range of the contralateral Stapedius reflex elicited by analog electrostimulation via cochlear implant was investigated in 8 subjects supplied with a Vienna prosthesis. The study comprised patients fitted with intracochlear devices as well as patients with extracochlear devices. Sinusoidal bursts of 125, 500, 1,000 and 2,000 Hz were used as stimulation signals. Only in one patient was saturation of reflex amplitude observed. The dynamic range of the Stapedius reflex was defined either by the difference in stimulus level for reflex saturation or individual uncomfortable loudness level and reflex threshold. Two different methods were used, yielding values between 0.1 and 12 dB, with a median of 4 dB. The individual results were compared with individual psychoacoustic quantities, i.e. subjective dynamic range (difference between sensation threshold and uncomfortable loudness level) and residual dynamic range (difference between most comfortable loudness level and uncomfortable loudness level). The reflex dynamic range is located within the residual dynamic range of electrostimulation. Thus the Stapedius reflex dynamic range can be applied as a rough estimate of minimum residual dynamic range.

Acoustic Stimulation↗

Evaluation of detector dynamic range in the x-ray exposure domain in mammography: a comparison between film-screen and flat panel detector systems.

Digital detectors in mammography have wide dynamic range in addition to the benefit of decoupled acquisition and display. How wide the dynamic range is and how it compares to film-screen systems in the clinical x-ray exposure domain are unclear. In this work, we compare the effective dynamic ranges of film-screen and flat panel mammography systems, along with the dynamic ranges of their component image receptors in the clinical x-ray exposure domain. An ACR mammography phantom was imaged using variable mAs (exposure) values for both systems. The dynamic range of the contrast-limited film-screen system was defined as that ratio of mAs (exposure) values for a 26 kVp Mo/Mo (HVL=0.34 mm Al) beam that yielded passing phantom scores. The same approach was done for the noise-limited digital system. Data from three independent observers delineated a useful phantom background optical density range of 1.27 to 2.63, which corresponded to a dynamic range of 2.3 +/- 0.53. The digital system had a dynamic range of 9.9 +/- 1.8, which was wider than the film-screen system (p<0.02). The dynamic range of the film-screen system was limited by the dynamic range of the film. The digital detector, on the other hand, had an estimated dynamic range of 42, which was wider than the dynamic range of the digital system in its entirety by a factor of 4. The generator/tube combination was the limiting factor in determining the digital system's dynamic range.

Breast Neoplasms↗

Signal-to-noise in phase angle reconstruction: dynamic range extension using phase reference offsets.

The dynamic range of phase-reconstructed magnetic resonance images is compared to that of magnitude-reconstructed images. From analysis of propagation of errors, the phase angle noise is phase-independent and given in radians by sigma ([I])/[I], the noise-to-signal ratio of the corresponding magnitude-reconstructed image. As the phase can range from minus pi to pi, the phase angle dynamic range is 2 pi times that of the signal magnitude. These results agree with experiment, verifying that the noise in the two receiver channels is uncorrelated. An artifact-free technique is presented for correcting phase spillover, which further extends the phase angle dynamic range. The reconstruction-based reference phase is adjusted on a local basis so that the boundary of phase wraparound is reconstructed near the center of the [- pi, pi] interval. For a particular flow study, the phase signal-to-noise was extended over twofold by spillover correction, to a value 15 times that of the magnitude signal-to-noise.

Algorithms↗

Relationship between the dynamic range of cochlear nerve fibres and their spontaneous activity.

The dynamic ranges of cochlear nerve fibres in cats were determined automatically and were related to the fibres' rates of spontaneous activity, in both pooled data and data from individual cochlear nerves. The dynamic range represents the range of levels of a tone at the characteristic frequency of the fibre evoking mean discharge rates between spontaneous and saturated activity. In common with the findings of other investigators, the distribution of spontaneous discharge rates was bimodal. The total population could be divided into two sub-populations with spontaneous discharge rates above and below 15 spikes/s, respectively. The mean dynamic range of fibres having spontaneous discharge rates in excess of 15 spikes/s, was 41 dB (+/- 0.65 S.E.); that for fibres with rates below 15 spikes/s was 50 dB (+/- 1.2 S.E.). While the distributions of dynamic ranges of the two populations overlapped, they were significantly different, and dynamic ranges in excess of 60 dB were only found in substantial numbers (23%) in the population having low spontaneous discharge rates. Some of these were not saturated at the highest stimulus levels used.

Animals↗

Dynamic range enhancement for cochlear implants.

HYPOTHESIS: The addition of a continuous, unmodulated, high-rate pulse train to sinusoidal stimuli presented by the cochlear implant to implant recipients will result in increases in the psychophysical dynamic range. BACKGROUND: The hearing dynamic range of cochlear implant patients is markedly reduced compared with that of normal-hearing individuals. This has negative implications for both speech perception and sound quality in these patients. It has been suggested that the addition of an unmodulated high-rate pulse train to deafened auditory nerves could create spontaneous-like neural activity, similar to that recorded from normal ears, of which one significant benefit would be an increase in the dynamic range of cochlear implant users. METHODS: Twenty-nine patients who underwent implantation with the Clarion CII device participated in this single-blinded prospective study. The psychophysical dynamic range of 28 of these subjects was measured with sinusoidal stimuli in response to various levels of an additional unmodulated high-rate pulse train. RESULTS: All the tested subjects (n = 28) demonstrated an increase in dynamic range in response to an appropriate level of unmodulated high-rate pulse train. The largest increase in dynamic range for each subject had a mean value of 6.7 dB. CONCLUSION: The addition of an unmodulated high-rate pulse train to the electric signal presented to cochlear implant patients results in significant increases in dynamic range for sinusoidal stimuli.

Acoustic Stimulation↗

The effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.

OBJECTIVE: To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN: Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The amplitudes of the sine waves were compressed in a systematic fashion to simulate the effect of reduced dynamic range. The compressed signals were presented to 10 normal-hearing listeners for identification. RESULTS: There was a significant effect of compression for all test materials. The effect of the compression on speech understanding was different for the three test materials (vowels, consonants, and sentences). Vowel recognition was affected the most by the compression, and consonant recognition was affected the least by the compression. Feature analysis indicated that the reception of place information was affected the most. Sentence recognition was moderately affected by the compression. CONCLUSIONS: Dynamic range should affect the speech perception abilities of cochlear implant users. Our results suggest that a relatively wide dynamic range is needed for a high level of vowel recognition and a relatively small dynamic range is sufficient to maintain consonant recognition. We infer from this outcome that, if other factors were held equal, an implant patient with a small dynamic range could achieve moderately high scores on tests of consonant recognition but poor performance on vowel recognition, and that it is more likely for an implant patient with a large dynamic range to obtain high scores on vowel recognition than for an implant patient with a small dynamic range.

Cochlear Implants↗

Dynamic range of neural rate responses in the ventral cochlear nucleus of awake cats.

1. Response thresholds and dynamic range properties of neurons in the ventral cochlear nucleus (VCN) of awake cats were measured by fitting a computational model to rate-level functions for best frequency (BF) tone bursts and for bursts of broad-band noise. Dynamic range measurements were performed in quiet and in the presence of continuous background noise. 2. The sample of neurons obtained in the VCN of awake cats exhibited a variety of peristimulus histograms (PSTHs) and thresholds. All PSTH response types previously described in the VCN of anesthetized cats were found in awake cats. The lowest thresholds for neural responses were observed at sound pressure levels that were equivalent to behavioral thresholds of absolute auditory sensitivity. 3. When responses to BF tones or bursts of broad-band noise were recorded in quiet backgrounds, the dynamic range properties of most units in the VCN of awake cats were not significantly different from dynamic range properties of auditory nerve fibers (ANFs) in anesthetized cats or VCN units in decerebrate cats. All auditory units showed a larger dynamic range for noise bursts than for tone bursts, but VCN units with primary-like and onset PSTHs showed larger dynamic ranges for responses to noise bursts than that of ANFs and VCN chopper units. 4. When tests were performed in the presence of continuous noise, rate-level functions for BF tone bursts shifted to higher tone levels and showed a more compressed range of driven rates in comparison with data obtained in quiet. Compression of the rate-level function in noise resulted from an increase in driven rate at low tone levels and a decrease in rate at high tone levels. These changes in the rate-level function suggest that noise may reduce the range of BF tone levels that are potentially encoded by a unit's rate responses. By exhibiting larger shifts and less compression in background noise, VCN units in awake cats better preserved the dynamic range of their rate responses to BF tones than ANFs in anesthetized cats or VCN units in decerebrate cats. 5. Rate-level functions were obtained from a small sample of VCN units not only with the cat performing the behavioral task but also with the cat awake and sitting quietly in the testing apparatus. No differences in noise-induced shift or compression were noted between the two testing conditions.(ABSTRACT TRUNCATED AT 400 WORDS)

Acoustic Stimulation↗

Maximal dynamic range electrotactile stimulation waveforms.

A new method to measure the dynamic range of electrotactile (electrocutaneous) stimulation uses both steepest ascent (gradient) and one-variable-at-a-time methods to determine the waveform variables that maximize the subjective magnitude (intensity) of the electrotactile percept at the maximal current without discomfort for balanced-biphasic pulse bursts presented at a 15-Hz rate. The magnitude at the maximal current without discomfort is maximized by the following waveform (range tested in parentheses): number of pulses/burst = 6 (1-20), pulse repetition rate within a burst = 350 Hz (200-1500), and phase width = 150 microseconds (40-350). The interphase interval (separation between positive and negative phases in a biphasic pulse) does not affect dynamic range from 0-500 microseconds. The number of pulses/burst has a large effect on the perceived dynamic range when this is measured using a subjective-magnitude-based algorithm, whereas it has little effect on the traditional dynamic range measure, i.e., (maximal current without discomfort)/(sensation threshold current). The perceived stimulus magnitude at the maximal current without discomfort is approximately twice as strong with 6 pulses/burst as it is with 1 pulse/burst (a frequently-used waveform).

Bias↗

Effects of the acoustical dynamic range on speech recognition with cochlear implants.

The amplitude compression function in a speech processor for cochlear implants maps the wide acoustical dynamic range of sounds into the smaller electrical dynamic range available on the implanted electrodes. In this study, we examined the effects of systematic variations of the acoustical dynamic range of the compression function on speech recognition with cochlear implants. Statistical measures of the amplitude distribution of speech sounds were made in each channel of a research speech processor providing more than 50 dB of input signal-to-noise ratio. Several systematic variations of the dynamic range of the compression function were implemented on this basis, and speech recognition was determined using vowel and consonant identification tests in three experienced cochlear implant users. Results demonstrated that the acoustical dynamic range of the compression function does have a significant effect on speech recognition with cochlear implants. They suggest that a dynamic range of about 45 dB is necessary for optimal speech recognition.

Acoustics↗

Range of acceptable stimulus intensities: an estimator of dynamic range for intensive perceptual continua.

The dynamic range (DR) of a sensory system is the span (usually given in log units) from the lowest to highest intensities over which a continuously graded response is evoked, and may be a distinctive feature of each such system. Teghtsoonian (1971) proposed that, although DR varies widely over sensory systems, its subjective size (SDR) is invariant. Assuming the psychophysical power law, the exponent for any continuum is given by the ratio of subjective span to DR, both quantities expressed logarithmically. Thus, exponents are inversely related to the DR and many be interpreted as indexes of it. Because DR can be difficult or even dangerous to measure directly, we sought to define a smaller range representing some fixed proportion of DR that could be used in its place to test the hypothesis of an invariant subjective range. Observations manipulated the intensities of five target continua to produce the broadest range they found acceptable and reasonably comfortable, a range of acceptable stimulus intensities (RASIN). Combined with an assumed constant SDR (derived from previous research), RASINs accurately predicted exponents obtained by magnitude production from the same observers on the five continua, as well as exponents reported in the literature.

Hand Strength↗

C fiber responses of wide dynamic range neurons in the spinal dorsal horn.

Responses of wide dynamic range neurons in the spinal dorsal horn to input from C fibers with various conduction velocities were analyzed. The wide dynamic range neurons studied were located in the laminae IV-VI of the spinal dorsal horn. The C fiber response to stimulation of the superficial peroneal nerve consisted of three components: early, middle, and late. The separation into three components was found to be caused by asynchronous volleys in three different classes of C fibers in the superficial peroneal nerve. The phenomenon of windup was observed to occur always in the late component, frequently in the middle component, and to a far lesser extent in the early component. The early component was augmented by sciatic nerve compression, indicating that the initial part of the C fiber response is suppressed within the spinal cord by an inhibitory effect of A fiber afferent volleys. An intravenous administration of a specific N-methyl-D-aspartate receptor antagonist, MK-801 hydrogen maleate, significantly suppressed the middle and late components of the C fiber response, although the effect on the early component was insignificant. Thus, one can infer that the hyperexcitability of wide dynamic range neurons to input from early components of cutaneous C fiber stimuli will yield hyperpathic symptoms such as paresthesia, hyperalgesia, and allodynia associated with damaged peripheral nerves, and that learning how to inhibit the hyperexcitability of wide dynamic range neurons to input from early components of C fiber stimuli will lead to the curative treatment for neuropathic pain.

Animals↗

High-rate conditioning pulse trains in cochlear implants: dynamic range measures with sinusoidal stimuli.

The addition of a continuous, unmodulated, high-rate pulse train to the electrical signals of cochlear implant recipients results in statistically significant increases in psychophysical dynamic range (41 out of 46 electrode pairs tested). The observed increases in dynamic range are thought to result from nerve conditioning by appropriate levels of high-rate pulse train. Five dynamic range profiles are characterized, defining the different responses of dynamic range observed with increasing levels of the conditioner. Four of the five profiles demonstrate increases in dynamic range, with three showing behavior consistent with stochastic resonance. One profile depicts evidence of adaptation in response to higher levels of the conditioner, with a recovery period lasting throughout the duration (on the scale of tens of minutes) of experimentation. Dynamic range profiles are shown to be similar across sinusoidal frequencies (202, 515, and 1031 Hz) but potentially different across electrode pairs (electrodes 1-2, 7-8, and 15-16). Correlation analysis does not reveal any predictors of optimal conditioner level or amount of dynamic range increase with the conditioner.

Adult↗