Calcium absorption from corn tortilla is relatively high and is dependent upon calcium content and liming in Mexican women.

Corn tortillas are the staple food of Mexico. During their preparation, calcium is added to the tortillas; therefore, tortillas are the main source of calcium for a large proportion of the population. The bioavailability of calcium from lime-treated tortillas in humans is not known. The objectives of the present study were to determine calcium absorption from corn tortilla, to determine the effect of lime treatment on calcium absorption from corn tortilla, and to compare calcium absorption from tortilla prepared with a commercial corn flour and tortillas prepared with the traditional lime treatment at home. Nonpregnant, nonlactating women (n = 9) were administered 3 different treatments: 1) 180 g of corn tortilla prepared from corn flour with no lime treatment (CF), 2) 180 g of corn tortilla prepared from lime-treated commercial corn flour (LTCCF), or 3) 180 g of corn tortillas prepared from lime-treated home-prepared corn flour (LTHCF). Calcium absorption was measured using an established dual-tracer stable isotope technique. Calcium absorption of CF, LTCCF, and LTHCF was (mean +/- SD): 44 +/- 3.2, 32 +/- 4.4, and 30 +/- 2.4%, respectively; the fractional calcium absorption from CF differed from that of either LTCCF or LTHCF (P < 0.01). The total amount of calcium absorbed per treatment was higher in LTHCF (98.10 mg +/- 21.7) than in LTCCF (59.9 mg +/- 23.7, P < 0.001) and CF (3.78 mg +/- 0.9, P < 0.0.001). In conclusion, calcium absorption from corn tortillas is high and dependent on calcium concentration. The addition of calcium during lime treatment increases calcium concentration and total calcium absorption.

Absorption↗

Neutron absorbed dose determination by calculations of recoil energy.

The aim of this work is to calculate the absorbed dose to matter due to neutrons in the 5-150 MeV energy range. Materials involved in the calculations are Al2O3, CaSO4 and CaS, which may be used as dosemeters and have already been studied for their luminescent properties. The absorbed dose is assumed to be mainly due to the energy deposited by the recoils. Elastic reactions are treated with the ECIS code while for the non-elastic ones, a Monte Carlo code has been developed and allowed to follow the nucleus decay and to determine its characteristics (nature and energy). Finally, the calculations show that the absorbed dose is mainly due to non-elastic process and that above 20 MeV this dose decreases slightly with the neutron energy.

Absorption↗

Difficulty in dislodging in vivo fixed radiostrontium.

Many trials based on the basic phenomena of isotopic dilution, adsorption, ion exchange, chelation, etc., have been attempted for the decorporation of radiostrontium, particularly Sr, after its entry in the in vivo system. We have recently demonstrated a non-isotopic carrier effect of some common calcium salts (calcium = 9 mg mL) to reduce the whole body retention of radiostrontium, if administered within 2 h after radiostrontium exposure and furthermore once daily, in rats, supplemented with calcium fortified diet. However, 25-30% of radiostrontium (compared to 50-60% in untreated animals) was still found to be retained in the animal even after 2 wk of treatment. Trial of some simple interventional measures, which would not adversely affect the animal metabolism, like pyrophosphate and magnesium sulfate, sodium citrate, chitin (a bio-absorbent), crown ether (a metal-chelator), and ammonium chloride, was therefore attempted to dislodge this remaining radiostrontium by switching over these animals to normal diet and subjecting them to different lines of treatment with these simple interventions through diet and drinking water separately for a further 4 wk. However, this remaining portion of radiostrontium is fixed in the bone and is difficult to dislodge.

Absorption↗

A supernumerary tooth fused to the facial surface of a maxillary permanent central incisor: case report.

A case of a supernumerary tooth fused to the facial surface of a maxillary permanent central incisor is reported. Root canal therapy on the maxillary central incisor was performed due to pulpal communication between the supernumerary tooth and the maxillary central incisor after removing the supernumerary tooth structure. The communication was sealed with mineral trioxide aggregate. The difference between fusion and gemination is discussed.

Aluminum Compounds↗

Adhesion of human osteoblasts on root-end filling materials.

Adhesion of human osteoblasts to root-end filling materials (mineral trioxide aggregate (MTA), IRM, composite, and amalgam) was observed by scanning electron microscopy. Root-end filling materials were inserted into 96-well flat-bottomed plates and condensed to disks of approximately 1 mm thick and the same diameter as the wells. After the disks were set, they were placed in the bottom of Nunc four-well culture plates at one disk per well. Then human osteoblasts were seeded into the wells at 1.5 x 10(5) cells per well. After 1 day in culture the disks of root-end filling materials along with cells grown on their surface were examined with a scanning electron microscopy. Results showed that osteoblasts attached and spread on MTA and composite by forming a monolayer. Osteoblasts also attached on amalgam, but with few cells spreading. In the presence of IRM, osteoblasts appeared rounded with no spreading. These results indicate that osteoblasts have a favorable response to MTA and composite resin compared with IRM and amalgam.

Aluminum Compounds↗

A new mineral trioxide aggregate root-end filling technique.

Carrier and syringe-type devices are currently used to deliver mineral trioxide aggregate as a root-end filling material. In certain surgical situations these devices may be too difficult to use because of the location of the surgical site and the small size of the root-end preparation. This paper describes a new technique to overcome these difficulties by the formation and delivery of mineral trioxide aggregate pellets.

Aluminum Compounds↗

PH changes at the surface of root dentin after intracanal dressing with calcium oxide and calcium hydroxide.

This study was designed to compare pH changes at the cervical and apical surfaces of root dentin after canal obturation with calcium oxide or calcium hydroxide pastes. The effect of the exposure to CO2 on the pH at the root surface also was assessed for both materials. Thirty-six extracted human canines were selected and instrumented. Wells 1 mm deep x 1.5 mm in diameter were drilled in the cervical and apical regions of the buccal root surface. The teeth were randomly divided into two groups and obturated with either calcium hydroxide or calcium oxide. pH was measured in the cervical and apical wells at varying time intervals until 48 days posttreatment. After pH measurement on day 48 the vials were flushed with CO2 and the pH measured again at days 53 and 68. The results indicated a similar pattern of pH increase after treatment with either calcium oxide or calcium hydroxide. pH dropped significantly after exposure to CO2 in both groups. This study demonstrated that hydroxyl ions produced when calcium oxide reacts with water diffuse through the dentinal tubules to the surface of the root in a manner similar to hydroxyl ions from calcium hydroxide.

Analysis of Variance↗

Leakage evaluation of root end filling materials using endotoxin.

Mineral trioxide aggregate (MTA) has been shown to possess excellent sealing ability when tested with dye, bacteria, and a fluid filtration technique. Endotoxin, a component of the cell wall of Gram-negative bacteria, has been proposed to play a role in the pathogenesis of periradicular lesions. This study used a modified Limulus Amebocyte Lysate test for the presence of endotoxin as a tracer and compared the sealing ability of Super-EBA, IRM, amalgam, and MTA. The results showed that MTA permitted less endotoxin leakage than IRM and amalgam at 1, 2, 6, and 12 wk (p < 0.05), and leaked less than Super-EBA at 2 and 12 wk (p < 0.05).

Aluminum Compounds↗

In vitro evaluation of furcal perforation repair using mineral trioxide aggregate or resin modified glass lonomer cement with and without the use of the operating microscope.

This study evaluated in vitro the effect of using the operating microscope on repairing furcation perforations using Vitrebond or mineral trioxide aggregate. Forty-six human molar teeth were mounted into a jig attached to a simulated jaw. The teeth were allocated randomly to four groups (n = 10). Furcal perforations were made in the teeth using an ISO 012 round bur in a slow-speed hand-piece. Each material was used to repair a group of teeth with and without the use of the operating microscope. The remaining six teeth provided positive and negative controls. All groups were stored in 100% humidity, and the repair materials were allowed to set for 72 h at room temperature before being assessed for the quality of placement under x26 magnification. Leakage at the repair was then tested using India ink; the teeth were demineralized, dehydrated in alcohol, and rendered transparent in methyl salicylate. Dye penetration into the furcation repair was evaluated at x26 magnification. There was no difference in the acceptability of the repair with either material whether or not the operating microscope was used. The perforations repaired with mineral trioxide aggregate leaked significantly less to the tracer dye than those repaired with Vitrebond (p < 0.001).

Aluminum Compounds↗

Repair of perforating internal resorption with mineral trioxide aggregate: a case report.

A case of internal resorption with buccal perforation was found in a maxillary central incisor. Because of the extensive lesion and continuous exudation, surgical intervention was used. The apical third was obturated with gutta-percha, and the perforated lesion was repaired with mineral trioxide aggregate. The residual canal space was filled by thermoplasticized gutta-percha technique, and the coronal cavity was restored with composite resin. The symptoms and signs ceased, and the results were satisfactory at 1-year follow-up.

Adult↗

Adhesion of human fibroblasts to root-end-filling materials.

This study evaluated the attachment of cultured explants of human periodontal ligament fibroblasts and gingival fibroblasts to different root-end-filling materials. Although periodontal ligament and gingival fibroblasts initially attached avidly to Geristore, these same cells displayed no significant attachment to ProRoot, Tytin amalgam, or SuperEBA. With further incubation on Geristore, the attachment of both periodontal ligament and gingival fibroblasts improved and these cells proliferated. In contrast, no improvement in attachment or proliferation was observed for cells incubated for greater times with ProRoot, Tytin amalgam, or SuperEBA. Because the attachment characteristics of these two groups of fibroblasts were identical, we examined the potential role of the extracellular matrix family of receptors (integrins) on the attachment of gingival fibroblasts. Gingival fibroblast attachment to collagen type I was determined to be dependent on alpha1beta1 and alpha2beta1 integrins, whereas their attachment to the RGD-binding sequence of fibronectin and vitronectin was partially inhibited by antibodies to the beta1 and alphaV integrin subunits. However, attachment of gingival fibroblasts to Geristore was not reduced by the addition of any of the attachment-perturbing anti-integrin antibodies examined. Thus, gingival fibroblasts attach to Geristore, but this attachment was mediated by mechanisms other than integrins.

Aluminum Compounds↗

Placement of mineral trioxide aggregate using two different techniques.

The purpose of this study was to determine if the adaptation of mineral trioxide aggregate (MTA) would differ when placed into simulated root canals of varying length when using two different placement and condensation methods. Hand condensation was compared to ultrasonic condensation. Eighty polyethylene tubes were divided into four groups of 20 tubes each. The tubes in the four groups were prepared to receive 3-, 5-, 7-, and 10-mm lengths of MTA respectively. Each group of 20 tubes was subdivided; 10 samples of each length had MTA placed and condensed by the hand method and the other 10 by the ultrasonic method. After condensation the samples were evaluated with a light microscope and radiographs for the degree of adaptation of the MTA to the tube walls and for the presence of voids within the MTA material itself. The results demonstrated an 80% agreement for findings between the light microscopy and radiographic evaluation. Hand condensation resulted in better adaptation to the tube walls and less voids than the ultrasonic method. There was no significant difference in the results for any of the four lengths of MTA placed by the hand method (p > 0.9). At this time hand condensation should be considered the preferred method for placement of MTA.

Aluminum Compounds↗

Attachment and morphological behavior of human periodontal ligament fibroblasts to mineral trioxide aggregate: a scanning electron microscope study.

The attachment and morphology of human periodontal ligament fibroblasts to mineral trioxide aggregate (MTA) was evaluated using a scanning electron microscope. The material was placed at an apical cavity of 30 single-rooted slices of extracted human teeth. The specimens were divided into two groups of 15 root slices each (freshly mixed and set state). For each experimental group, five root slices were used per observation period (4, 8, and 24 h). A set of two glass slides was used per observation period for the control group. The experiments were performed in tissue-culture cluster 96-well plates in which 1 ml of human periodontal ligament fibroblast cell suspension was placed over the MTA filling and the control glass slides. For the positive-control group, 0.5 ml of methyl methacrylate 2% (vol/vol) was added to the cell suspensions before being dispensed into the wells. Results showed the normal cell morphology in the negative controls. Few round cells with less smooth surfaces and many rough blebs were seen in the positive control, and most of these cells did not show any attachment to the substratum. Similar observations were seen with the freshly prepared-MTA group. In the set-MTA group, cells were round and flattened, displayed smooth surfaces, and appeared to be tightly attached to MTA. It was concluded that the quality and quantity of cell attachment to the retrofilling material could be used as a criterion to evaluate material's toxicity. This research (FN#1077) is registered with the College of Dentistry research center, King Saud University, Riyadh, Saudi Arabia. The author thanks the administration of the King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia, and in particular Dr. M. N. Al-Ahdal for providing the use of the Molecular Virology and Infectious Disease Laboratory, Mr. Yunus Siddiqui for his support, and Dr. Saad AL-Nazhan for his assistance in preparing the manuscript.

Aluminum Compounds↗

Repair of root perforations using mineral trioxide aggregate: a long-term study.

Root perforations adversely affect the prognosis of teeth. Inadequacy of the repair materials has been a contributing factor to the poor outcome of repair procedures. Mineral trioxide aggregate (MTA) is a relatively new material that is being successfully used to repair perforations. The purpose of this study was to evaluate the success rate of root perforation repairs using MTA. A list of all of the perforation repairs completed with MTA at an endodontic residency program was obtained. Sixteen cases were included that met the criteria for this study. Pretreatment, immediate posttreatment, and at least 1 year follow-up radiographs were evaluated in a double-blind manner to determine the presence or absence of any pathologic changes adjacent to the perforation site. The results showed that all 16 cases demonstrated normal tissue architecture adjacent to the repair site at the recall visit. Teeth with existing lesions showed resolution of the lesion, and teeth without preoperative lesions continued to demonstrate absence of lesion formation at the follow-up visit. Based on the results of this study, MTA provides an effective seal of root perforations and shows promise in improving the prognosis of perforated teeth that would otherwise be compromised.

Aluminum Compounds↗

Perforation repair comparing two types of mineral trioxide aggregate.

The purpose of this study was to evaluate the ability of two types of mineral trioxide aggregate (MTA) to seal furcal perforations in extracted human molars using an anaerobic bacterial leakage model. Forty, human, maxillary and mandibular molars were randomly divided into two experimental groups of 18, with two teeth used as positive controls and two teeth without perforations used as negative controls. Experimental group 1 was repaired with gray-colored MTA and group 2 with off-white-colored MTA. A dual-chamber, anaerobic, bacterial-leakage model was assembled. Brain-heart infusion broth with yeast extract, hemin, and menadione was used as the culture broth for Fusobacterium nucleatum. Two of 18 gray-colored MTA samples leaked and three off-white-colored MTA samples leaked. There was no significant difference between the two types of MTA in preventing leakage of F. nucleatum past furcal perforation repairs.

Aluminum Compounds↗