PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Fabrication of poly(dimethylsiloxane) microfluidic system based on masters directly printed with an office laser printer.

Applications of poly(dimethylsiloxane) (PDMS)-based microfluidic systems are more popular nowadays. Previous fabrication methods of the masters for PDMS microchannels require complicated steps and/or special device. In this paper, we demonstrated that the toner printed on the transparency film with the office laser printer (1200 dpi) can be used as the positive relief of the masters. The transparency film was printed in two steps in order to obtain the same printing quality for the crossed lines. With the laser-printed master, the depth of the fabricated PDMS microchannels was ca. 10 microm and the smallest width was ca. 60 microm. Surface characteristics of the PDMS/PDMS microchannels were performed with SEM. Their electrokinetic properties were investigated by the aids of the measurement of electroosmotic flow (EOF) and the Ohm's curve. Using the PDMS/PDMS microchip CE systems, electroactive biological molecules and non-electroactive inorganic ions were well separated, respectively. This simple approach could make it easy to carry out the studies of PDMS microfluidic systems in more general labs without special devices.

Dimethylpolysiloxanes↗

Microfluidic chip with electrochemiluminescence detection using 2-(2-aminoethyl)-1-methylpyrrolidine labeling.

A tertiary amine derivative, 2-(2-aminoethyl)-1-methylpyrrolidine (AEMP) was successfully developed as electrochemiluminescence (ECL) probe within microfluidic chip using ECL detection in this paper. The system was characterized by the interaction between biotin and avidin. In principle, tertiary amine derivatives containing active group can be used as a potential alternative of traditional tris(2,2'-bipyridine)ruthenium(II) [Ru(bpy)3(2+)] label. Firstly, The ECL efficiency of AEMP was characterized via comparing with that of two coreactants enhancing Ru(bpy)3(2+) ECL, TPA and proline. At same condition, AEMP has a similar ECL efficiency to TPA, and much higher than proline. After AEMP reacted with NHS-LC-biotin (succinimidyl-6-(biotinamido) hexanoate), the products and their ECL were analyzed by directly injecting it in the microfluidic chip. A 4.5 cm microchannel was used to separate the mixture of AEMP and biotinylated AEMP. The present works indicated that AEMP has a good reactivity to the analytes containing carboxyl group with a similar ECL efficiency to TPA. Under optimal condition, the detection limits (based on 3 S/N) of AEMP was 2.7 microM. The system was also validated by the reaction between biotin and avidin. The calculated binding ratio between avidin and biotin based on the present method was 4.4.

Aminocaproates↗

Fabrication of microfluidic devices using dry film photoresist for microchip capillary electrophoresis.

An inexpensive, disposable microfluidic device was fabricated from a dry film photoresist using a combination of photolithographic and hot roll lamination techniques. A microfluidic flow pattern was prefabricated in a dry film photoresist tape using traditional photolithographic methods. This tape became bonded to a poly(methyl methacrylate) (PMMA) sheet with prepouched holes when passed through a hot roll laminator. A copper working electrode and platinum decoupler was readily incorporated within this microchip. The integrated microchip device was then fixed in a laboratory-built Plexiglas holder prior to its use in microchip capillary electrophoresis. The performance of this device with amperometric detection for the separation of dopamine and catechol was examined. The separation was complete within 50 s at an applied potential of 200 V/cm. The relative standard deviations (RSD) of analyte migration times were less than 0.71%, and the theoretical plate numbers for dopamine and catechol were 3.2 x 10(4) and 4.1 x 10(4), respectively, based on a 65 mm separation channel.

Electrophoresis, Capillary↗

Novel multi-depth microfluidic chip for single cell analysis.

A novel multi-depth microfluidic chip was fabricated on glass substrate by use of conventional lithography and three-step etching technology. The sampling channel on the microchip was 37 microm deep, while the separation channel was 12 microm deep. A 1mm long weir was constructed in the separation channel, 300 microm down the channel crossing. The channel at the weir section was 6 microm deep. By using the multi-depth microfluidic chip, human carcinoma cells, which easily aggregate, settle and adhere to the surface of the channel, can be driven from the sample reservoir to the sample waste reservoir by hydrostatic pressure generated by the difference of liquid level between sample and sample waste reservoirs. Single cell loading into the separation channel was achieved by applying a set of pinching potentials at the four reservoirs. The loaded cell was stopped by the weir and precisely positioned within the separation channel. The trapped cell was lysed by sodium dodecyl sulfate (SDS) containing buffer solution in 20s. This approach reduced the lysing time and improved the reproducibility of chip-based electrophoresis separations. Reduced glutathione (GSH) and reactive oxygen species (ROS) were used as model intracellular components in single human carcinoma cells, and the constituents were separated by chip-based electrophoresis and detected by laser-induced fluorescence (LIF). A throughput of 15 samples/h, a migration time precision of 3.1% RSD for ROS and 4.9% RSD for GSH were obtained for 10 consecutively injected cells.

Fluorescence↗

Surface modification on microfluidic devices with 2-methacryloyloxyethyl phosphorylcholine polymers for reducing unfavorable protein adsorption.

Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.

Adsorption↗

Why the move to microfluidics for protein analysis?

There has been a recent trend towards the miniaturization of analytical tools, but what are the advantages of microfluidic devices and when is their use appropriate? Recent advances in the field of micro-analytical systems can be classified according to instrument performance (which refers here to the desired property of the analytical tool of interest) and two important features specifically related to miniaturisation, namely reduction of the sample volume and the time-to-result. Here we discuss the contribution of these different parameters and aim to highlight the factors of choice in the development and use of microfluidic devices dedicated to protein analysis.

Animals↗

Dynamic osmotic loading of chondrocytes using a novel microfluidic device.

Many cells exhibit disparate responses to a mechanical stimulus depending on whether it is applied dynamically or statically. In this context, few studies have examined how cells respond to dynamic changes of the extracellular osmolality. In this study, we hypothesized that the cell size change response of cultured articular chondrocytes would be dependent on the frequency of applied osmotic loading. To test this hypothesis, we developed a novel microfluidic device, to apply hydrostatic pressure-driven dynamic osmotic loading by applying composition modulated flow, adapted from Tang and co-workers. This microfluidic device was used to study osmotic loads of +/-180 mOsm at a frequency up to 0.1 Hz with a constant minimal fluid-shear stress, and permit real-time monitoring of cell responses. Bovine articular chondrocytes were observed to exhibit increasing changes in cell volume with decreasing osmotic loading frequency. When the cell volume response was modeled by an exponential function, chondrocytes exhibited significantly different volume change responses to dynamic osmotic loading at 0.0125 Hz and static osmotic loading applied for a period of four minutes (Delta = +/-180 mOsm relative to the isotonic 360 mOsm). The intracellular calcium response at 0.0125 Hz was also monitored and compared with the response to static loading. Coupled with phenomenological or constitutive models, this novel approach could yield new information regarding cell material properties in response to dynamic loading that may contribute new insights into mechanisms of cellular homeostasis and mechanotransduction.

Animals↗

A water-activated pump for portable microfluidic applications.

An on-chip micropump for portable microfluidic applications was investigated using mathematical modeling and experimental testing. This micropump is activated by the addition of water, via a dropper, to ionic polymer particles that swell due to osmotic effects when wetted. The resulting particle volume increase deflects a membrane, forcing a separate fluid from an adjacent reservoir. The micropump components, along with the microfluidic components, are fabricated using the contact liquid photolithographic polymerization (CLiPP) method. The maximum flow rate achieved with this pump is 17 microL per minute per mg of dry polymer particles of 355-425 microm in diameter. The pump flow rate may be controlled by adjusting the particle size and amount, the membrane properties, and the channel dimensions. The experimental results demonstrate good agreement with an analytical model describing the particle swelling and its coupling with resistive forces from the bending membrane, viscous flow in the microchannel, and interfacial effects. Key features of this micropump are that it can be placed directly on a microdevice, and that it requires only a small amount of water and no external power supply to function. Therefore, this pumping system is useful for applications in which a highly portable device is required.

Microfluidic Analytical Techniques↗

Fabrication and characterization of microfluidic probes for convection enhanced drug delivery.

Convection enhanced drug delivery (CED) is a promising therapeutic method for treating diseases of the brain by enhancing the penetration of drugs. Most controlled release delivery methods rely on diffusion from a source to transport drugs throughout tissue. CED relies on direct infusion of drugs into tissue at a sufficiently high rate so that convective transport of drug is at least as important as diffusive transport. This work describes the fabrication and characterization of microfluidic probes for CED protocols and the role diffusion plays in determining penetration. Microfluidic channels were formed on silicon substrates by employing a sacrificial photoresist layer encased in a parylene structural layer. Flow in the microchannels was characterized by applying constant upstream pressures from 35 to 310 kPa, which resulted in flow rates of 0.5-4.5 microL/min. The devices were used to infuse Evans Blue and albumin in hydrogel brain phantoms. The results of these infusions were compared to a simple convection-diffusion model for infusions into porous media. In vivo infusions of albumin were performed in the gray matter of rats at upstream pressures of 35, 70, and 140 kPa. The microfabricated probes show reduced evidence of backflow along the device-tissue interface when compared with conventional needles used for CED.

Albumins↗

Applications of microfluidics for neuronal studies.

Microfabrication processes have changed the technology used in consumer goods, and have now advanced into applications in biology. Microfluidic platforms are microfabricated tools that are gaining popularity for studies of molecular and cellular biology. These platforms can allow precise control of the environment surrounding individual cells and they have been used to study physiologic and pharmacologic responses at the single-cell level. This article reviews microfluidic technology with emphasis on advances that could apply to the study of the nervous system, including architecture for isolation of axons, integrated electrophysiology, patterned physical and chemical substrate cues, and devices for the precisely controlled delivery of possible therapeutic agents such as trophic factors and drugs. The potential of these chips for the study of neurological diseases is also discussed.

Animals↗

FISH and chips: marine bacterial communities analyzed by flow cytometry based on microfluidics.

To unveil the structure of natural marine pelagic bacterial communities, PCR-based techniques as well as fluorescence in situ hybridizations (FISH) were successfully performed in the past. Using fluorescence microscopes or confocal laser scanning microscopes (CLSM) for the analysis of FISH experiments, it was possible to differentiate bacterial communities, but most attempts to combine flow cytometry and FISH for this purpose have failed till now. Here we present a successful analysis of FISH experiments of natural marine pelagic bacterial communities using a flow cytometer based on microfluidics (Agilent 2100 bioanalyzer). Marine water samples were enriched on polycarbonate filters and hybridized with Cy5 labeled gene probes of different phylogenetic depth. Bacteria were detached from the filters and subsequently analyzed in the Cell Chip of the Agilent 2100 Bioanalyzer. Samples were counter-stained using SYTOX. In all samples the EUB338 positive signals could be clearly differentiated from those of the NON probe. Furthermore a dominance of alpha-protebacteria (as indicated by the probes ALF968 and G rB) could be observed. Microfluidics based flow cytometry is a promising technique for the analysis of natural bacterial communities from the marine environment.

Bacteria↗

Rapid and simple detection of food poisoning bacteria by bead assay with a microfluidic chip-based system.

A rapid bead assay for detecting pathogenic bacteria with a simple microfluidic chip-based system was developed. Five oligonucleotide probes corresponding to the 16S rRNA of the targeted bacteria were coupled covalently to fluorescent beads. Four species of bacteria (Escherichia coli, Salmonella enterica subsp. enterica serovar Enteritidis, Yersinia enterocolitica, and Bacillus cereus) were used as representative food-borne pathogenic bacteria. The RNAs extracted from pure cultures of these microorganisms were fluorescently labeled and hybridized to the oligonucleotide probes-immobilized fluorescent beads (Bead assay). The duplexes of RNAs and the probes-immobilized beads were analyzed with the commercially available microfluidic chip-based system. This bead assay provided results within 3 h following RNA extraction from bacterial cells.

Bacillus cereus↗

DNA probe attachment on plastic surfaces and microfluidic hybridization array channel devices with sample oscillation.

DNA probe immobilization on plastic surfaces and device assembly are both critical to the fabrication of microfluidic hybridization array channel (MHAC) devices. Three oligonucleotide (oligo) probe immobilization procedures were investigated for attaching oligo probes on four different types of plastic surfaces (polystyrene, polycarbonate, poly(methylmethacrylate), and polypropylene). These procedures are the Surmodics procedure, the cetyltrimethylammonium bromide (CTAB) procedure, and the Reacti-Bind procedure. To determine the optimal plastic substrate and attachment chemistry for array fabrication, we investigated plastic hydrophobicity, intrinsic fluorescence, and oligo attachment efficiency. The Reacti-Bind procedure is least effective for attaching oligo probes in the microarray format. The CTAB procedure performs well enough to use in array fabrication, and the concentration of CTAB has a significant effect on oligo immobilization efficiency. We also found that use of amine-modified oligo probes resulted in better immobilization efficiency than use of unmodified oligos with the CTAB procedure. The oligo probe immobilization on plastic surfaces by the Surmodics procedure is the most effective with regard to probe spot quality and hybridization sensitivity. A DNA hybridization assay on such a device results in a limit of detection of 12pM. Utilizing a CO(2) IR laser machining and adhesive layer approach, we have developed an improved procedure for realizing a DNA microarray inside a microfluidic channel. This device fabrication procedure allows for more feasible spot placement in the channel and reduced sample adsorption by adhesive tapes used in the fabrication procedure. We also demonstrated improved hybridization kinetics and increased detection sensitivity in MHAC devices by implementing sample oscillation inside the channel. A limit of detection of 5pM has been achieved in MHAC devices with sample oscillation.

Carbocyanines↗

Socket with built-in valves for the interconnection of microfluidic chips to macro constituents.

This paper reports a prototype for a standard connector between a microfluidic chip and the macro world. This prototype demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data signals and energy supply. It supports up to 10 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. The socket has built-in valves for each flow channel. It also contains 28 pins for the connection of electrical signals and power. Built-in valves make it possible to control the flow in each channel independently. A chip ( 11.0 x 11.0 x 0.9 mm) can be mounted into or dismounted from the socket with one touch. The fluidic connectors of the socket are designed to contact vertically on the top of chip. And the electrical connectors (the spring array) of that physically support the chip and contact lead pads at the bottom of chip. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.

Equipment Design↗

Microarray and microfluidic methodology for genotyping cytokine gene polymorphisms.

Cytokine genetic polymorphisms are the subject of disease-association studies that require large-scale human genotyping. Polymerase chain reaction based custom microarrays and microfluidics systems were used to develop genotyping assays for following cytokine polymorphisms: tumor necrosis factor-alpha G-308A, interleukin-4 (IL-4) C-589T, interferon-gamma (CA)n repeats, IL-1RN 86-bp variable number of tandem repeats (VNTR), and CCR5 32-bp indel. For G-308A, 70.9% of DNA samples assayed were homozygous for wild type, 25.5% were heterozygous, and none were homozygous for variant allele. For C-589T, 35.5% of DNA samples were homozygous for wild type, 38% were heterozygous, and 22% were homozygous for variant. For IL-1RN VNTR, 71% of DNA samples were homozygous and the remainder were heterozygous. For CCR5, 96.4% of amplicons were homozygous for wild type, and 3.6% were heterozygous containing deletion. For IFN-gamma (CA)n repeats, 35.6% had 2,2 alleles, 42.2% had 2,3 alleles, and 11% had 3,3 alleles with alleles 1 through 5 corresponding to 11 through 15 repeats, respectively. There was good concordance between the results we obtained and current "gold-standard" methodologies for analyzing single nucleotide polymorphisms and size polymorphisms. Electronic DNA concentration with high stringency predisposes microarray technology to hybridization fidelity and accuracy, and microfluidics systems outperform conventional methodologies for size polymorphisms. Comprehensive genotyping can be achieved for clinical epidemiologic studies on cytokine gene polymorphisms using this approach.

Cytokines↗

Microfluidic technologies in drug discovery.

Microfluidic systems are increasingly used as tools in various stages of the drug discovery process. Microscale systems offer several obvious advantages, such as low sample consumption and significantly reduced analysis or experiment time. These technologies raise the possibility of massive parallelization and concomitant reduction in cost per acquired data point. In addition, fluids in confined spaces display unique behaviors that can be used to acquire information not accessible using macroscopic systems. This article will focus on the implementation of microfluidic systems and technologies in the process of drug discovery.

Chemistry, Pharmaceutical↗

A microfluidic platform using molecular beacon-based temperature calibration for thermal dehybridization of surface-bound DNA.

This work presents a simple microfluidic device with an integrated thin-film heater for studies of DNA hybridization kinetics and double-stranded DNA melting temperature measurements. The heating characteristics of the device were evaluated with a novel, noninvasive indirect technique using molecular beacons as temperature probes inside reaction chambers. This is the first microfluidic device in which thermal dehybridization of surface-bound oligonucleotides was performed for measurement of double-stranded DNA melting temperatures with +/- 1 degrees C precision. Surface modification and oligonucleotide immobilization were performed by continuously flowing reagents through the microchannels. The resulting reproducibility of oligonucleotide surface densities, at 9% RSD, was better than for the same modification chemistries on glass slides in unstirred reagent solutions (RSD=20%). Moreover, the surface density of immobilized DNA probe molecules could be varied controllably by changing the concentration of the reagent solution used for immobilization. Thus, excellent control of surface characteristics was made possible, something which is often difficult to achieve with larger devices. Solid-phase hybridization reactions, a fundamental aspect of microarray technologies often taking several hours in conventional systems, were reduced to minutes in this device. It was also possible to determine forward rate constants for hybridization, k. These varied from 820,000 to 72,000 M(-1) s(-1), decreasing as surface densities increased. Surface densities could therefore be optimized to obtain rapid hybridization using such an approach. Taken together, this combined microfluidic/small-volume heating approach represents a powerful tool for surface-based DNA analysis.

Calibration↗

Microfluidic devices for the high-throughput chemical analysis of cells.

A microfluidic device is reported that integrated cell handling, rapid cell lysis, and electrophoretic separation and detection of fluorescent cytosolic dyes. The device function was demonstrated using Jurkat cells that were loaded with the fluorogenic dyes - carboxyfluorescein diacetate, Oregon green carboxylic acid diacetate, or Calcein AM. The loaded cells were hydrodynamically transported from the cell-containing reservoir to a region on the microfluidic device where they were focused and then rapidly lysed using an electric field. Complete lysis was accomplished in <33 ms. The hydrolyzed, fluorescent dyes in the cell lysate were automatically injected into a separation channel on the device and detected 3 mm downstream of the injection point. The total separation time was approximately 2.2 s with absolute migration time reproducibilities of <1% and efficiencies ranging from 2300 to 4000 theoretical plates. Results from 139 cells are reported. A small fraction of these cells, approximately 9%, were found to enzymatically hydrolyze the loaded dyes in a manner significantly different from the majority of the cells. Cell analysis rates of 7-12 cells/min were demonstrated and are >100 times faster than those reported using standard bench-scale capillary electrophoresis.

Algorithms↗