PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Design of a compact disk-like microfluidic platform for enzyme-linked immunosorbent assay.

This paper presents an integrated microfluidic device on a compact disk (CD) that performs an enzyme-linked immunosorbent assay (ELISA) for rat IgG from a hybridoma cell culture. Centrifugal and capillary forces were used to control the flow sequence of different solutions involved in the ELISA process. The microfluidic device was fabricated on a plastic CD. Each step of the ELISA process was carried out automatically by controlling the rotation speed of the CD. The work on analysis of rat IgG from hybridoma culture showed that the microchip-based ELISA has the same detection range as the conventional method on the 96-well microtiter plate but has advantages such as less reagent consumption and shorter assay time over the conventional method.

Animals↗

Ultrasonic mixing in microfluidic channels using integrated transducers.

This paper presents a microfluidic mixer that uses acoustic stirring created by ultrasonic waves. The ultrasound is introduced into the channel by integrated piezoelectric transducers. The transducers are made of a zinc oxide thin film, which is deposited on the bottom surface of a quartz substrate. The poly(dimethylsiloxane) channel is aligned to the transducers on the top surface of the substrate. The transducers are designed for operation around 450 MHz. The main mechanism of the mixing is the acoustic stirring of the fluid perpendicular to the flow direction. The radiation pressure that is generated by the transducer causes the stirring inside the microfluidic channel. The performance of the mixer is characterized by mixing phenolphthalein solution and sodium hydroxide dissolved in ethyl alcohol. Flow rates on the order of 1-100 microL/min are used. The transducers are driven by 1.2 V(rms) sinusoidal voltages at 450 MHz.

Microfluidics↗

DNA displacement assay integrated into microfluidic channels.

This paper describes the development of a unique fluorescence-based DNA diagnostic microfluidic assay that does not require labeling of the target sequence prior to analysis. The assay is based on the displacement of a short sacrificial fluorescent-tagged indicator oligomer by a longer untagged target sequence as it is electrophoresed through a DNA-containing hydrogel plug immobilized in a microfluidic channel. The distinct advantages of this assay are the short sensing times, as a result of directed electrophoretic transport of target DNA to the sensing element, combined with the ability to detect nonlabeled target DNA.

DNA↗

Detection of phosphorylated peptides in proteomic analyses using microfluidic compact disk technology.

A compact disk (CD)-based microfluidic method for selective detection of phosphopeptides by mass spectrometry is described. It combines immobilized metal affinity chromatography (IMAC) and enzymatic dephosphorylation. Phosphoproteins are digested with trypsin and processed on the CD using nanoliter scale IMAC with and without subsequent in situ alkaline phosphatase treatment. This is followed by on-CD matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Dephosphorylation of the IMAC-enriched peptides allows selective phosphopeptide detection based on the differential mass maps generated (mass shifts of 80 Da or multiples of 80 Da). The CD contains 96 microstructures, each with a 16 nL IMAC microfluidic column. Movement of liquid is controlled by differential spinning of the disk. Up to 48 samples are distributed onto the CD in two equal sets. One set is for phosphopeptide enrichment only, the other for identical phosphopeptide enrichment but combined with in situ dephosphorylation. Peptides are eluted from the columns directly into MALDI target areas, still on the CD, using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into a MALDI mass spectrometer for analysis down to the femtomole level. The average success rate in phosphopeptide detection is over 90%. Applied to noncharacterized samples, the method identified two novel phosphorylation sites, Thr 735 and Ser 737, in the ligand-binding domain of the human mineralocorticoid receptor.

Alkaline Phosphatase↗

Microfluidic selection and retention of a single cardiac myocyte, on-chip dye loading, cell contraction by chemical stimulation, and quantitative fluorescent analysis of intracellular calcium.

A microfluidic method to study the contraction of a single cardiac myocyte (heart muscle cell) has been developed. This method integrates various single-cell operations as well as on-chip dye loading, and quantitative analysis of intracellular calcium concentration, [Ca2+]i. After the channel enlargement by on-chip etching to accommodate large-sized cardiac myocytes, a single cell is selected and retained at a V-shaped cell retention structure within the microchip. Owing to the fragile property of the cardiac myocytes that could easily be damaged by centrifugation, the calcium-sensitive fluorescent dye was loaded in the cell by on-chip dye loading. This on-chip method minimized the damage to the cells from the use of a centrifuge in the conventional method and provided a way of cellular analysis of fragile cells. Subsequently, quantitative analysis of [Ca2+]i of a single cardiac myocyte by fluorescence measurement was achieved for the first time in a microfluidic chip, thanks to the intracellular calcium stimulant of ionomycin. The resting [Ca2+]i of the cardiomyocyte determined was consistent with the literature value. From the spontaneous contraction study, it was found that fluorescence intensity cannot represent the [Ca2+]i variation accurately, which implied the importance of the quantitative analysis of [Ca2+]i.

Animals↗

Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs.

The present investigation describes the analytical performances of a microfluidic device comprising an enrichment column, a reversed-phase separation channel, and a nanoelectrospray emitter embedded altogether in polyimide layers. This configuration minimizes transfer lines and connections and reduces postcolumn peak broadening and dead volumes. This compact and versatile modular nanoLC-chip system was interfaced to both ion trap and time-of-flight mass spectrometers, and its analytical potentials were evaluated in the context of proteomics applications. The figures of merit of this system in terms of peak capacity, reproducibility, sensitivity, and linear dynamic range of peptide detection were determined using tryptic digests of complex protein extracts including albumin- and immunoglobulin-depleted rat plasma samples. The analysis of peak profiles for more than 600 peptide ions reproducibly detected across replicate nanoLC-chip-MS runs (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity with RSD values of less than 0.5 and 9.1%, respectively. Variation in peptide abundance as low as 2-fold changes was identified for spiked tryptic digests present at levels of 2-5 fmol in plasma samples. Sensitivity measurements were performed on dilution series of protein digests spiked into rat plasma samples and provided a detection limit of 1-5 fmol. The modular concept of the microfluidic systems also facilitated the integration of two-dimensional chromatography (strong cation exchange/C18) thereby increasing the sample loading and selectivity of the nanoLC-chip-MS system. The application of this integrated device was evaluated for complex rat plasma samples to compare the number of protein identifications obtained using one- and two-dimensional nanoLC-chip-MS/MS.

Biomarkers↗

Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices.

An important problem in the life sciences and in health care is simple and rapid detection of biomarkers. Although microfluidic devices are potentially useful in addressing this problem, current techniques for automating fluid delivery--which include valves and electroosmosis--require sophisticated microfabrication of the chip, bulky instrumentation, or both. In this paper, we describe a simple and reliable technique for storing and delivering a sequence of reagents to a microfluidic device. The technique is low-cost, requires minimal user intervention, and can be performed in resource-poor settings (e.g., outside of a laboratory) in the absence of electricity and computer-controlled equipment. In this method, cartridges made of commercially available tubing are filled by sequentially injecting plugs of reagents separated by air spacers. The air spacers prevent the reagents from mixing with each other during cartridge preparation, storage, and usage. As an example, we used this "plug-in cartridge" technology to complete a solid-phase immunoassay in a microchannel in 2 min with low-nanomolar sensitivity and demonstrate the diagnosis of HIV in 13 min.

Acquired Immunodeficiency Syndrome↗

Si-supported mesoporous and microporous oxide interconnects as electrophoretic gates for application in microfluidic devices.

Microfluidic analysis systems are becoming an important technology in the field of analytical chemistry. An expanding area is concerned with the control of fluids and species in microchannels by means of an electric field. This paper discusses a new class of Si-compatible porous oxide interconnects for gateable transport of ions. The integration of such thin oxide films in microfluidics devices has been hampered in the past by the compatibility of oxides with silicon technology. A general fabrication method is given for the manufacture of silicon microsieve support structures by micromachining, on which a thin oxide layer is deposited by the spin-coating method. The deposition method was used for constructing gamma-alumina, MCM-48 silica, and amorphous titania films on the support structures, from both water-based and solvent-based oxide sols. The final structures can be applied as microporous and mesoporous interconnecting walls between two microchannels. It is demonstrated that the oxide interconnects can be operated as ion-selective electrophoretic gates. The interconnects suppress Fick diffusion of both charged and uncharged species, so that they can be utilized as ionic gates with complete external control over the transport rates of anionic and cationic species, thus realizing the possibility for implementation of these Si-compatible oxide interconnects in microchip analyses for use as dosing valves or sensors.

Diffusion↗

Microfluidic immunoassay for bacterial toxins with supported phospholipid bilayer membranes on poly(dimethylsiloxane).

We report a heterogeneous immunoassay for cholera toxin (CT) using supported bilayer membranes (SBMs) in a poly(dimethylsiloxane) (PDMS) microfluidic device. Phosphatidylcholine membranes assembled on plasma-oxidized PDMS by vesicle fusion bring about favorable surface properties, such as improved wettability and protein resistance. Contact angle measurements show that the lipid membranes can preserve hydrophilic surfaces for hours, whereas untreated substrates rapidly undergo hydrophobic recovery. Fluorescence recovery after photobleaching performed in situ reveals that the membranes have relatively high lateral mobility. Experimental data-fitting to theoretical models yields diffusion coefficients of 1.8 +/- 0.7 microm(2)/s on PDMS and 3.4 +/- 0.8 microm(2)/s on glass. Fluorescence studies utilizing tagged proteins show that SBMs reduce nonspecific adsorption of avidin and BSA on PDMS by 2-3 orders of magnitude, as compared to that on plasma oxidized surfaces. SBMs and their protein-resistant properties are not significantly affected by long flow times, indicating good membrane stability. These studies increase our understanding of the relationship between molecular level interactions and membrane properties, allowing for development of a rapid heterogeneous immunoassay for CT in PDMS microchips with cell surface receptor molecules. Using optimized sample injection and buffer washing conditions, microfluidic immunoassay of CT is complete within 25 min, and a dynamic range over 3 orders of magnitude with a detection limit of 8 fmol of toxin is achieved.

Adsorption↗

Manipulation of self-assembled structures of magnetic beads for microfluidic mixing and assaying.

We present an original concept of manipulation of magnetic microbeads in a microchannel. It is based on the dynamic motion of a self-assembled structure of ferrimagnetic beads that are retained within a microfluidic flow using a local alternating magnetic field. The latter induces a rotational motion of the magnetic particles, thereby strongly enhancing the fluid perfusion through the magnetic structure that behaves as a dynamic random porous medium. The result is a very strong particle-liquid interaction that can be controlled by adjusting the magnetic field frequency and amplitude, as well as the liquid flow rate, and is at the basis of very efficient liquid mixing. The principle is demonstrated using a microfluidic chip made of poly(methyl methacrylate) with integrated soft ferromagnetic plate structures. The latter are part of an electromagnetic circuit and serve to locally apply a magnetic field over the section of the microchannel. Starting from a laminar flow pattern of parallel fluorescein dye and nonfluorescent liquid streams, we demonstrate a 95% mixing efficiency using a mixing length of only 400 microm and at liquid flows of the order of 0.5 cm/s. We anticipate that the intense interaction between the fluid and magnetic particles with functionalized surfaces holds large potential for the development of future bead-based assays.

Magnetics↗

Stable microstructured network for protein patterning on a plastic microfluidic channel: strategy and characterization of on-chip enzyme microreactors.

Chemical modification of a poly(methyl methacrylate) (PMMA) microchannel surface has been explored to functionalize microfluidic chip systems. A craft copolymer was designed and synthesized to introduce the silane functional groups onto the plastic surface first. Furthermore, it has been found that, through a silicon-oxygen-silicon bridge that formed by tethering to these functional groups, a stable patterning network of gel matrix could be achieved. Thus, anchorage of proteins could be realized onto the hydrophobic PMMA microchannels with bioactivity preserved as far as possible. The protein homogeneous patterning in a microfluidic channel has been demonstrated by performing microchip capillary electrophoresis with laser-induced fluorescence detection and confocal fluorescence microscopy. To investigate the bioactivity of enzymes entrapped within stable silica gel-derived microchannels, the suggested scheme was employed to the construction of immobilized enzyme microreactor-on-a-chip. The proteolytic activity of immobilized trypsin has been demonstrated with the digestion of cytochrome c and bovine serum albumin at a fast flow rate of 4.0 microL/min, which affords the short residence time less than 5 s. The digestion products were characterized using MALDI-TOF MS with sequence coverage of 75 and 31% observed, respectively. This research exhibited a simple but effective strategy of plastic microchip surface modification for protein immobilization in biological and proteomic research.

Amino Acid Sequence↗

Thermoplastic elastomer gels: an advanced substrate for microfluidic chemical analysis systems.

We demonstrate the use of thermoplastic elastomer gels as advanced substrates for construction of complex microfluidic networks suitable for use in miniaturized chemical analysis systems. These gels are synthesized by combining inexpensive polystyrene-(polyethylene/polybutylene)-polystyrene triblock copolymers with a hydrocarbon extender oil for which the ethylene/butylene midblocks are selectively miscible. The insoluble styrene end blocks phase separate into localized nanodomains, resulting in the formation of an optically transparent, viscoelastic, and biocompatible gel network that is melt-processable at temperatures in the vicinity of 100 degrees C. This unique combination of properties allows microfluidic channels to be fabricated in a matter of minutes by simply making impressions of the negative relief structures on heated master molds. Melt processability allows multiple impressions to be made against different masters to construct complex geometries incorporating multi-height features within the same microchannel. Intricate interconnected multilayered structures are also easily fabricated owing to the ability to bond and seal multiple layers by briefly heating the material at the bond interface. Thermal and mechanical properties are tunable over a wide range through proper selection of gel composition.

Biocompatible Materials↗

Thermoplastic microfluidic platform for single-molecule detection, cell culture, and actuation.

We have developed a multipurpose microfluidic platform that allows for sensitive fluorescence detection on inexpensive disposable chips. The fabrication scheme involves rapid injection molding of thermoplastics, followed by silica deposition and covalent attachment of an unstructured flexible lid. This combines the virtues of elastomer technology with high-throughput compact disk injection molding. Using this technique, the time to produce 100 chips using a single master can be lowered from more than 1 week by standard PDMS technologies to only a couple hours. The optical properties of the fabricated chips were evaluated by studying individual fluorescence-labeled DNA molecules in a microchannel. Concatemeric DNA molecules were generated through rolling circle replication of circular DNA molecules, which were labeled by hybridization of fluorescence-tagged oligonucleotides. Rolling circle products (RCPs) were detected after as little as 5 min of DNA polymerization, and the RCPs in solution showed no tendency for aggregation. To illustrate the versatility of the platform, we demonstrate two additional applications: The flexible property of the lid was used to create a peristaltic pump generating a flow rate of 9 nL/s. Biocompatibility of the platform was illustrated by culturing Chinese hamster ovary cells for 7 days in the microfluidic channels.

Animals↗

Microfluidic chip for low-flow push-pull perfusion sampling in vivo with on-line analysis of amino acids.

Multilayer soft lithography was used to prepare a poly(dimethylsiloxane) microfluidic chip that allows for in vivo sampling of amino acid neurotransmitters by low-flow push-pull perfusion. The chip incorporates a pneumatically actuated peristaltic pump to deliver artificial cerebrospinal fluid to a push-pull perfusion probe, pull sample from the probe, perform on-line derivatization with o-phthaldialdehyde, and push derivatized amino acids into the flow-gated injector of a high-speed capillary electrophoresis-laser-induced fluorescence instrument. Peristalsis was achieved by sequential actuation of six, 200 microm wide by 15 microm high control valves that drove fluid through three fluidic channels of equal dimensions. Electropherograms with 100,000 theoretical plates were acquired at approximately 20-s intervals. Relative standard deviations of peak heights were 4% in vitro, and detection limits for the excitatory amino acids were approximately 60 nM. For in vivo measurements, push-pull probes were implanted in the striatum of anesthetized rats and amino acid concentrations were monitored while sampling at 50 nL/min. o-Phosphorylethanolamine, glutamate, aspartate, taurine, glutamine, serine, and glycine were all detected with stable peak heights observed for over 4 h with relative standard deviations of 10% in vivo. Basal concentrations of glutamate were 1.9 +/- 0.6 microM (n = 4) in good agreement with similar methods. Monitoring of dynamic changes of neurotransmitters resulting from 10-min applications of 70 mM K(+) through the push channel of the pump was demonstrated. The combined system allows temporal resolution for multianalyte monitoring of approximately 45 s with spatial resolution 65-fold better than conventional microdialysis probe with 4-mm length. The system demonstrates the feasibility of sampling from a complex microenvironment with transfer to a microfluidic device for on-line analysis.

Amino Acids↗

Microfluidic platform for liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures.

A microfluidic chip that integrates all the fluidic components of a gradient liquid chromatography (LC) system is described. These chips were batch-fabricated on a silicon wafer using photolithographic processes and with Parylene as the main structural material. The fabricated chip includes three electrolysis-based electrochemical pumps, one for loading the sample and the other two for delivering the solvent gradient; platinum electrodes for delivering current to the pumps and establishing the electrospray potential; a low-volume static mixer; a column packed with silica-based reversed-phase support; integrated frits for bead capture; and an electrospray nozzle. The fabricated structures were able to withstand pressures in excess of 250 psi. The device was used to perform a liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of a mixture of peptides from the trypsin digestion of bovine serum albumen (BSA). Gradient elution through the 1.2-cm column was performed at a flow rate of 80 nL/min. Compared to the analysis of the same sample using a commercial nanoflow LC system, the chromatographic resolution was nearly as good, and the total cycle time was significantly reduced because of the minimal volume between the pumps and the column. Results demonstrate the potential of mass-produced, low-cost microfluidic systems capable of performing LC separations for proteomics applications.

Amino Acid Sequence↗

NMR analysis on microfluidic devices by remote detection.

We present a novel approach to perform high-sensitivity NMR imaging and spectroscopic analysis on microfluidic devices. The application of NMR, the most information-rich spectroscopic technique, to microfluidic devices remains a challenge because the inherently low sensitivity of NMR is aggravated by small fluid volumes leading to low NMR signal and geometric constraints resulting in poor efficiency for inductive detection. We address the latter by physically separating signal detection from encoding of information with remote detection. Thereby, we use a commercial imaging probe with sufficiently large diameter to encompass the entire device, enabling encoding of NMR information at any location on the chip. Because large-diameter coils are too insensitive for detection, we store the encoded information as longitudinal magnetization and flow it into the outlet capillary. There, we detect the signal with optimal sensitivity, using a solenoidal microcoil, and reconstruct the information encoded in the fluid. We present a generally applicable design for a detection-only microcoil probe that can be inserted into the bore of a commercial imaging probe. Using hyperpolarized 129Xe gas, we show that this probe enables sensitive reconstruction of NMR spectroscopic information encoded by the large imaging probe while keeping the flexibility of a large coil.

Microfluidic Analytical Techniques↗

Open, microfluidic flow cell for studies of interfacial processes at gas-liquid interfaces.

Interfacial processes involving peripheral proteins depend on the composition and packing density of the interfacial lipid molecules. As a biological membrane model, lipid monolayers at the gas-liquid interface allow independent control of these parameters. However, measuring protein adsorption to monolayers has been difficult. To aid in this and other studies of the interfacial processes, we have developed an open, microfluidic flow cell with which surface physical properties can be controlled and monitored in well-defined lipid monolayers while varying aqueous-phase composition. Using this apparatus, we implement a recently described fluorescence method (Momsen, W. E.; Mizuno, N. K.; Lowe, M. E.; Brockman, H. L. Anal. Biochem. 2005, 346, 139-49) to characterize the adsorption/desorption of glucagon to 1,2-dioleoyl-sn-glycerol monolayers at 27 mN/m. Analysis of the data gives reasonable and self-consistent results for kinetic and thermodynamic constants. Varying the packing density of 1,2-dioleoyl-sn-glycerol does not alter the extent of glucagon adsorption, but comparable measurements with 1-steaoryl-2-oleoyl-sn-glycero-3-phosphocholine show a critical dependence. Because it allows a high degree of control of both lipid monolayer properties and aqueous-phase composition, this microfluidic flow cell should find wide applicability in many areas of research into interfacial processes.

Adsorption↗

Liver-specific functional studies in a microfluidic array of primary mammalian hepatocytes.

Nearly half a billion dollars in resources are lost each time a drug candidate is withdrawn from the market by the Food and Drug Administration (FDA) for reasons of liver toxicity. The number of late-phase drug developmental failures due to liver toxicity could potentially be reduced through the use of hepatocyte-based systems capable of modeling the response of in vivo liver tissue to toxic insults. With this article, we report progress toward the goal of realizing an array of primary hepatocytes for use in high-throughput liver toxicity studies. Described herein is the development of a 64 (8 x 8) element array of microfluidic wells capable of supporting micropatterned primary rat hepatocytes in coculture with 3T3-J2 fibroblasts. Each of the wells within the array was continuously perfused with medium and oxygen in a nonaddressable format. The key features of the system design and fabrication are described, including the use of two microfluidic perfusion networks to provide the coculture with an independent and continuous supply of cell culture medium and oxygen. Also described are the fabrication techniques used to selectively pattern hepatocytes and 3T3-J2 fibroblasts within the wells of the array. The functional studies used to demonstrate the synthetic and metabolic capacity of the array are outlined in this article. These studies demonstrate that the hepatocytes contained within the array are capable of continuous, steady-state albumin synthesis (78.4 microg/day, sigma = 3.98 microg/day, N = 8) and urea production (109.8 microg/day, sigma = 11.9 microg/day, N = 8). In the final section of the article, these results are discussed as they relate to the final goal of this research effort, the development of an array of primary hepatocytes for use in physiologically relevant toxicology studies.

3T3 Cells↗