PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of phenylurea herbicides in aqueous samples.

Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.

Calibration↗

Headspace solid-phase microextraction of sulphides and disulphides using Carboxen-polydimethylsiloxane fibers in the analysis of wine aroma.

Headspace solid-phase microextraction was applied to gas chromatography coupled to flame photometric detection to develop a method for analysing volatile sulphides and disulphides in wine. The Carboxen-polydimethylsiloxane-coated silica fiber was tested and different parameters such as presampling time, ionic strength, stirring, headspace volume, ethanol concentration, time and temperature of extraction were optimized to make extraction as efficient as possible. The optimized conditions enabled limits of detection to be obtained at the ng/l levels. The fiber tested has a strong affinity for the sulphur compounds studied and enables these analytes to be quantitatively determined in wines. The Carboxen-polydimethylsiloxane-coated fiber is more efficient at extracting than fibers such as those which are polydimethylsiloxane-coated and polyacrylate-coated, but its repeatability is worse. The overall process was successfully applied to identify and quantify sulphur compounds in white, red, rose and vintage wines.

Adsorption↗

Identification of various urinary metabolites of fluorene using derivatization solid-phase microextraction.

A method for the qualitative analysis of various metabolites of fluorene is presented. The method uses solid-phase microextraction with an 85 microm polyacrylate fiber for extraction, headspace silylation with BSTFA and MTBSTFA without any catalyst for on-fiber derivatization and GC-MS in the selected ion monitoring mode for separation and detection. The suitability of the method for profile analysis of polycyclic aromatic hydrocarbon metabolites is shown by analyzing an urine of an occupationally exposed person after enzymatic cleavage of the excreted conjugates. Satisfactory separation of all investigated metabolites was achieved without interferences due to matrix peaks.

Calibration↗

Airflow rate in the quantitation of volatiles in air streams by solid-phase microextraction

A previously reported method for nonequilibrium quantitation of air-borne volatiles from air streams by solid-phase microextraction (SPME) was improved by broadening its scope. The original method was defined for the 100-microm poly(dimethylsiloxane) fiber type for a wide range of analytes, sampling temperatures, and sampling times, but only for four specific airflow configurations. The present study extends the choice of volumetric airflow rates to a continuous range between 2 and 220 mL/min. Kinetics of absorption was characterized for 21 different airflow rates within this range using n-alkanes of 11-18 carbons. Nonlinear regression analysis was used to develop a relationship between airflow rate and absorption kinetics and then to integrate these results into the previous model. The overall model (with 8 fitted degrees of freedom and based on 2240 measurements) had an r2 value of 0.9972 and residual variability (RSD) of 9.75%, which compared favorably with the sampling precision of SPME (approximately 5%). The method allows absolute quantitation by SPME for a broad range of analytes and sampling parameters without prior calibration of the individual fiber and regardless of whether equilibration is complete. Simulations are presented that demonstrate how the choice of airflow rate can affect quantitation.

Journal Article↗

Evaluation of solid-phase microextraction for time-weighted average sampling of volatile sulfur compounds at ppb concentrations.

The potential of solid-phase microextraction (SPME) for time-weighted average (TWA) sampling of volatile sulfur compounds in air at ppb concentrations was investigated. The target compounds (hydrogen sulfide, methanethiol (MeSH), ethanethiol (EtSH), dimethyl sulfide (Me2S), and dimethyl disulfide (Me2S2)) were extracted using SPME with a Carboxen-poly(dimethylsiloxane) fiber coating, and diffusion was controlled by keeping the fiber retracted within the needle of the sampling device. The effects of several important experimental variables (air velocity, direction of air flow, analyte concentration, humidity, temperature, extraction time) were studied. The uptake by the fiber was not affected by the direction of the air flow or the air velocity. The effects of concentration, humidity, temperature, and extraction time were examined in experiments with a central composite face design. The results showed that all or most of the investigated parameters had a significant impact on the uptake rates of H2S, MeSH, EtSH, and Me2S, which invalidated time-weighted average sampling of these compounds by SPME under the tested conditions. Moreover, reverse diffusion of H2S, MeSH, and EtSH occurred at 40% relative humidity. For Me2S2, the uptake rate had a variation of only 8% within the whole experimental domain, and the experimental value derived for the uptake rate was consistent with the theoretical value. This result was confirmed by comparative analyses of industrial samples by the standard addition method. Therefore, SPME appears to be a suitable technique for TWA sampling of Me2S2 using the Carboxen-poly(dimethylsiloxane) fiber coating. Finally, in an investigation of potential losses during storage of the fiber, no significant losses of the target compounds were detected after 3 days at -80 degrees C.

Journal Article↗

Calibration for on-site analysis of hydrocarbons in aqueous and gaseous samples using solid-phase microextraction.

Rapid sampling and sample preparation methodology was investigated using adsorptive poly(dimethylsiloxane)/divinylbenzene and Carboxen/poly(dimethylsiloxane) solid-phase microextraction (SPME) fiber coatings and volatile aromatic hydrocarbons (BTEX: benzene, toluene, ethylbenzene, and o-xylene). A flow-through system was used to generate a standard aqueous solution of BTEX as model sample with known linear velocity. Parameters that affect the extraction process, including sampling time, concentration, water velocity, and temperature, were investigated. Very short sampling times from 10 s and sorbents with strong affinity and large capacity were used to ensure the effect of '"zero sink" and to calibrate the extraction process in the initial linear extraction region. Several different concentrations were investigated, and it was found that mass uptake changes with concentration linearly. The increase of water velocity increases mass uptake, though the increase is not linear. Temperature does not affect mass uptake significantly under typical field sampling conditions. To further accurately describe rapid SPME analysis of aqueous samples, a new model translated from heat transfer to a circular cylinder in cross-flow was used. An empirical correlation to this model was used to predict the mass-transfer coefficient. Findings indicate that predicted mass uptake compares well with experimental mass uptake. The new model was tested for rapid air sampling, and it was found that this new model also predicted rapid air sampling accurately. Findings presented in this study extend the existing fundamental knowledge related to rapid sampling/sample preparation with SPME.

Journal Article↗

Screening method for nitroaromatic compounds in water based on solid-phase microextraction and infrared spectroscopy.

A new method is described for determining nitroaromatic compounds in water that combines solid-phase microextraction (SPME) and infrared (IR) spectroscopy. In this method, the compounds are extracted from a 250-mL volume of water into a small square (3.2 cm x 3.2 cm x 61.2 microm thick) of silicone polycarbonate copolymer film (MEM-213). Five nitroaromatic compounds, including 2,4,6-trinitrotoluene (TNT), were chosen to evaluate the SPME/IR procedure. Quantitation limits for the five test compounds range from 50 microg/L for TNT to 400 microg/L for nitrobenzene. Precision values, determined at aqueous concentrations of four times the quantitation limit, range from 4 to 7%, and linear dynamic ranges extend to the maximum limit of the IR instrumentation. The potential of this SPME/IR method for determining nitroaromatics in natural water samples was also investigated by extracting "real world" soil samples contaminated with TNT. Results obtained from the SPME/ IR determination of the diluted extracts were in reasonable agreement with those obtained from dichloromethane extraction followed by gas chromatographic analysis.

Chromatography, Gas↗

Bioconcentration of organic chemicals: is a solid-phase microextraction fiber a good surrogate for biota?

When organic chemicals are extracted from a water sample with solid-phase microextraction (SPME) fibers, the resulting concentrations in exposed fibers are proportional to the hydrophobicity of the compounds. This fiber accumulation is analogous to the bioconcentration of chemicals observed in aquatic organisms. The objective of this study was to investigate the prospect of measuring the total concentration in SPME fibers to estimate the total body residue in biota for the purpose of risk assessment. Using larvae of the midge, Chironomus riparius and disposable 15-microm poly(dimethylsiloxane) fibers, we studied the accumulation and accumulation kinetics of a number of narcotic compounds with a range of log K(ow) between 3 and 6. The fibers, which have a larger surface area-to-volume ratio, had consistently higher uptake and elimination rate constants (k1 and k2, respectively) than midge larvae and accumulated the chemicals 5 times faster. Comparison of the relationships of the partition coefficients K(PDMS-water) and K(midge-water) (lipid-normalized) to log K(ow) for all compounds yielded a factor of 28 for translating fiber concentrations to biota concentrations. This factor can be used to estimate internal concentrations in biota for compounds structurally similar to the compounds in this study. The exact chemical domain to which this factor can be applied needs to be defined in future research.

Animals↗

Quantitative determination of geosmin in red beets (Beta vulgaris L.) using headspace solid-phase microextraction.

An improved analytical method for the determination of geosmin in red beets was developed using headspace solid-phase microextraction (HSPME). Volatiles of beet juice were extracted in headspace for 2 h using a polydimethylsiloxane/divinylbenzene fiber, thermally desorbed from the fiber, and analyzed by gas chromatography. The HSPME method was determined to be suitable for geosmin analysis as evidenced by high relative recovery (99.2%), low relative standard deviation (7.48%), and reasonable detection limit (1 microg/kg of beet root tissue). The concentrations of geosmin in four beet cultivars ranged from 9.69 +/- 0.22 to 26.7 +/- 0.27 microg/kg, depending on cultivar.

Beta vulgaris↗

Dynamic field sampling of airborne organophosphate triesters using solid-phase microextraction under equilibrium and non-equilibrium conditions.

A simple setup for dynamic air sampling using a solid-phase microextraction (SPME) device designed for use in the field was evaluated for organophosphate triester vapour under both equilibrium and non-equilibrium conditions. The effects of varying the applied airflows in the sampling device were evaluated in order to optimise the system with respect to the Reynolds number and magnitude of the boundary layer that developed near the surface. Further, the storage stability of the analytes was studied for both capped and uncapped 100-microm PDMS fibres. Organophosphate triesters are utilized on large scales as flame-retardants and/or plasticizers, for instance in upholstered furniture. In indoor working environments these compounds have become common components in the surrounding air. Measurements were performed in a recently furnished working environment and the concentration of tris(2-choropropyl) phosphate was found to be 7 microg m(-3).

Air Pollutants, Occupational↗

Evaluation of solid-phase microextraction desorption parameters for fast GC analysis of cocaine in coca leaves.

By its simplicity and rapidity, solid-phase microextraction (SPME) appears as an interesting alternative for sample introduction in fast gas chromatography (fast GC). This combination depends on numerous parameters affecting the desorption step (i.e., the release of compounds from the SPME fiber coating to the GC column). In this study, different liner diameters, injection temperatures, and gas flow rates are evaluated to accelerate the thermal desorption process in the injection port. This process is followed with real-time direct coupling a split/splitless injector to a mass spectrometer by means of a short capillary. It is shown that an effective, quantitative, and rapid transfer of cocaine (COC) and cocaethylene (CE) is performed with a 0.75-mm i.d. liner, at 280 degrees C and 4 mL/min gas flow rate. The 7-microm polydimethylsiloxane (PDMS) coating is selected for combination with fast GC because the 100-microm PDMS fiber presents some limitations caused by fiber bleeding. Finally, the developed SPME-fast GC method is applied to perform in less than 5 min, the quantitation of COC extracted from coca leaves by focused microwave-assisted extraction. An amount of 7.6 +/- 0.5 mg of COC per gram of dry mass is found, which is in good agreement with previously published results.

Chromatography, Gas↗

Optimisation of the derivatisation reaction and subsequent headspace solid-phase microextraction method for the direct determination of chlorophenols in red wine.

An acetylation reaction for the derivatisation of the three chlorophenols involved in cork taint was optimised using a Doehlert design for direct application in wine samples. In this first step, the optimum reaction pH, by adding different amounts of KHCO3, and the required quantity of derivatisation reagent were fixed. Then a series of parameters relevant for the headspace solid-phase microextraction process, such as desorption conditions, salt addition and agitation sample were evaluated. A simultaneous study of the type of fibre and extraction temperature was performed at five levels and based on the results obtained the rest of factors (sample volume and exposition time) that could potentially affect the extraction yields were optimised by a central composite design. According to the validation of the method, we propose here, to our knowledge, the first application of solid-phase microextraction for the direct analysis of chlorophenols in red wine samples.

Acetic Anhydrides↗

Enantiomeric monoterpene emissions from natural and damaged Scots pine in a boreal coniferous forest measured using solid-phase microextraction and gas chromatography/mass spectrometry.

In order to develop a valuable method for accurate screening of biogenic emissions from undisturbed living plants or for plant-insect interactions, solid-phase microextraction (SPME) has been combined with dynamic branch enclosure cuvettes and enantioselective GC/MS. The study was conducted at Hyytiälä forest station, Finland within a boreal coniferous forest dominated by Scots pine (Pinus sylvestris). The SPME method was optimized for monoterpenes by testing three fibre coatings: polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and carbowax/divinylbenzene (CW/DVB) and determining the optimum exposure time. The PDMS/DVB fibre was found to be most suitable and was used to characterize emissions of P. sylvestris enclosed in dynamic branch enclosure cuvettes by exposure for 1 min followed by desorption and separation on a beta-cyclodextrin column installed in the GC/MS oven. Dynamic cuvette measurements have been compared to static headspace SPME samples of the emission of detached needles from the same tree species and a portable dynamic air sampler (PDAS)-SPME for sampling the ambient air around the same trees. The method developed has allowed an accurate characterization of the gaseous emission of P. sylvestris and the identification of 17 isoprenoids comprising chiral and achiral monoterpenes. Two chemotypes of Scots pine can be differentiated through their emission of (+)-delta-3-carene. While SPME-dynamic cuvette, portable dynamic sampler and absorbent results agreed well, significant differences in enantiomeric ratios were observed in natural emissions and those of damaged leaves. Therefore, in enantioselective studies of plant-insect and/or plant-plant interactions, the two enantiomers of a given monoterpene should be treated as two separate substances.

Finland↗

Characterization of volatile organic compounds and odors by in-vivo sampling of beef cattle rumen gas, by solid-phase microextraction, and gas chromatography-mass spectrometry-olfactometry.

Volatile organic compounds (VOCs) and odors in cattle rumen gas have been characterized by in-vivo headspace sampling by solid-phase microextraction (SPME) and analysis by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). A novel device enabling headspace SPME (HS-SPME) sampling through a cannula was designed, refined, and used to collect rumen gas samples from steers. A Carboxen-polydimethylsiloxane (PDMS) fiber (85 microm) was used for SPME sampling. Fifty VOCs from ten chemical groups were identified in the rumen headspace. The VOCs identified had a wide range of molecular weight (MW) (34 to 184), boiling point (-63.3 to 292 degrees C), vapor pressure (1.05x10(-5) to 1.17x10(2) Pa), and water solubility (0.66 to 1x10(6) mg L-1). Twenty-two of the compounds have a published odor detection thresholds (ODT) of less than 1 ppm. More than half of the compounds identified are reactive and have an estimated atmospheric lifetime of <24 h. The amounts of VFAs, sulfide compounds, phenolic compounds, and skatole, and the odor intensity of VFAs and sulfide compounds in the rumen gas were all higher after feeding than before feeding. These results indicate that rumen gases can be an important potential source of aerial emissions of reactive VOCs and odor. In-vivo sampling by SPME then GC-MS-O analysis can be a useful tool for qualitative characterization of rumen gases, digestion, and its relationship to odor and VOC formation.

Animal Feed↗

Application of solid-phase microextraction combined with derivatization to the determination of amphetamines by liquid chromatography.

This work evaluates the utility of solid-phase microextraction (SPME) in the analysis of amphetamines by liquid chromatography (LC) after chemical derivatization of the analytes. Two approaches have been tested and compared, SPME followed by on-fiber derivatization of the extracted amphetamines, and solution derivatization followed by SPME of the derivatives formed. Both methods have been applied to measure amphetamine (AP), methamphetamine (MA), and 3,4-methylenedioxymethamphetamine (MDMA), using the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) and carbowax-templated resin (CW-TR)-coated fibers. Data on the application of the proposed methods for the analysis of different kind of samples are presented. When analyzing aqueous solutions of the analytes, both approaches gave similar analytical performance, but the sensitivity attainable with the solution derivatization/SPME method was better. The efficiencies observed when processing spiked urine samples by the SPME/on-fiber derivatization approach were very low. This was because the extraction of matrix components into the fiber coating prevented the extraction of the reagent. In contrast, the efficiencies obtained for spiked urine samples by the solution derivatization/SPME approach were similar to those obtained for aqueous samples. Therefore, the later method would be the method of choice for the quantification of amphetamines in urine.

Amphetamines↗

Sampling and analysis of volatile organic compounds in bovine breath by solid-phase microextraction and gas chromatography-mass spectrometry.

A relatively noninvasive method consisting of a face mask sampling device, solid-phase microextraction (SPME) fibers, and a gas chromatography-mass spectrometry (GC-MS) for the identification of volatile organic compounds (VOCs) in bovine breath was developed. Breath of three morbid steers with respiratory tract infections and three healthy steers were sampled seven times in 19 days for 15 min at each sampling. The breath VOCs adsorbed on the divinylbenzene (DVB)-Carboxen-polydimethyl siloxane (PDMS) 50/30 microm SPME fibers were transported to a laboratory GC-MS system for separation and identification with an in-house spectral library of standard chemicals. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Statistical analyses using Chi-square test on the frequency of detection of each VOC in each group was performed. The presence of acetaldehyde (P < or = 0.05) and decanal (P < or = 0.10) were associated more with clinically morbid steers while methyl acetate, heptane, octanal, 2,3-butadione, hexanoic acid, and phenol were associated with healthy steers at P < or = 0.10. The results suggest that noninvasive heath screening using breath analyses could become a useful diagnostic tool for animals and humans.

Animals↗

Solid-phase extraction versus solid-phase microextraction for the determination of chlorinated paraffins in water using gas chromatography-negative chemical ionisation mass spectrometry.

Solid-phase extraction (SPE) and solid-phase microextraction (SPME) were evaluated for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples using gas chromatography coupled to negative chemical ionisation mass spectrometry (GC-NCI-MS). For SPE optimisation, four commercially available SPE cartridges were tested and several SPE parameters, such as the elution solvent, elution volume and breakthrough volume were studied. The best results were obtained with Varian Bond Elut-C18. In order to achieve a high selectivity in the determination of SCCPs, GC-NCI-MS was used. Quality parameters of the optimised SPE and SPME procedures were determined, and the best results were obtained for the SPE/GC-NCI-MS method with LODs of 5 and 20 ng l(-1) for tap and river water, respectively. This method was successfully applied to the analysis of SCCPs in river water samples at concentrations below the microg l(-1) level.

Chlorine↗