PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Capsulorhexis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Plate-haptic silicone intraocular lens implantation: long-term results.

PURPOSE: To present the 10- to 12-year functional and morphological results of in-the-bag implantation of a foldable, plate-haptic, silicone posterior chamber intraocular lens (IOL). SETTING: Department of Ophthalmology, University of Vienna Medical School, Vienna, Austria. METHODS: Between September 1987 and December 1989, 160 silicone posterior chamber IOLs (Staar AA-4203C) were implanted in the capsular bag through a 3.5 mm corneoscleral incision after a continuous curvilinear capsulorhexis was created. In spring 1999, 36 patients (38 eyes) could be included in a follow-up examination. RESULTS: The median follow-up was 10.5 years +/- 2 (SD). The mean visual acuity was 0.82 +/- 0.34. The mean refraction (spherical equivalent) was +0.57 diopter (D), an insignificant change from the mean at the first postoperative follow-up at 1 month (+0.40 D). Slitlamp examination showed mildly dispersed pigment on the IOL surface in 81.58% of cases. All IOLs had a Tyndall effect (clouding). In 84.21%, the effect was minimal, in 10.53% it was moderate, and in 5.26% it was more intense. Ninety-two percent of the IOLs were centered within 0.5 mm. Of the 22 cases of decentration (57.89%), 86.36% were toward the 12 o'clock position in the bag. The neodymium:YAG capsulotomy rate was 10.52%. There were no cases of IOL-related inflammation or a clinically significant cystoid macular edema. CONCLUSION: The 10- to 12-year results suggest favorable clinical results of implantation of Staar AA-4203C plate-haptic, silicone posterior chamber IOLs.

Aged↗

Forceps-guided nuclear cleavage cataract extraction.

We introduce a manual nuclear fragmentation technique, forceps-guided nuclear cleavage. A 5.5 to 7.0 mm superior scleral incision is started 1.5 mm posterior to the limbus. Two additional 1.0 mm paracenteses are made at 3 and 9 o'clock in clear cornea close to the limbus. A continuous curvilinear capsulorhexis (CCC) is created; in most cases, 4 to 5 radial relaxing incisions are made in the CCC. The anterior and equatorial cortex and epinucleus are removed with 2-handed irrigation/aspiration via the 2 paracenteses with the nucleus in the capsular bag. The nucleus is prolapsed into the anterior chamber. A nucleus hook is inserted via the 3 o'clock paracentesis and applied to the 6 o'clock nuclear equator to hold the nucleus. A nucleus cleaving forceps is inserted through the upper incision to the 12 o'clock equator of the nucleus and advanced to one-third depth of the nucleus. The forceps is relaxed while the nucleus is cleaved in half.

Aged↗

Management of the small pupil for clear corneal cataract surgery.

PURPOSE: To evaluate the benefits of using the Perfect Pupil expansion device (Becton Dickinson Ophthalmic Surgical) for cataract surgery. SETTING: Eye Laser Center, Tucson, Arizona, USA. METHODS: Thirty patients whose pupils failed to dilate beyond 4.0 mm were selected to have the Perfect Pupil used during their cataract surgery. The Perfect Pupil was inserted through an unenlarged 2.8 mm clear corneal incision into the pupillary aperture. The capsulorhexis, hydrodissection, phacoemulsification, and injection of the intraocular lens were performed through the expanded pupil with the device in place. The pupil size before, during, and after surgery was measured. RESULTS: The mean pupil size was 3.2 mm preoperatively, 7.8 mm after insertion of the device, and 4.3 mm after its removal. There were no cases of iris sphincter tear, bleeding, ruptured capsule, or irregular pupil postoperatively. CONCLUSION: The Perfect Pupil was beneficial during small-incision cataract surgery in cases in which the pupil failed to dilate adequately. The device was easy to insert and remove, expanded the pupil to approximately 8.0 mm, protected the iris sphincter during surgery, and allowed the pupil to return to its normal size, shape, and function postoperatively.

Capsulorhexis↗

Permanent blue discoloration of a hydrogel intraocular lens by intraoperative trypan blue.

A 79-year-old white man had cataract surgery in the right eye with implantation of an Acqua intraocular lens (IOL) (Mediphacos). Trypan blue 0.1% was used during surgery to stain the anterior capsule and enhance the contrast during capsulorhexis. Seven days after surgery, the patient presented with "dark and double" vision (monocular diplopia). The IOL was decentered superiorly and appeared dark blue. The lens was explanted 2 months after surgery and sent for gross and microscopic analyses in a dry state and after hydration. The same analyses were performed on 2 unused lenses of the same design that had been immersed in diluted trypan blue solutions (0.01% and 0.001%). On the explanted lens, the dark blue staining was denser in the optic, especially in its periphery. The blue discoloration could not be removed after 24 hours of lens immersion in a balanced salt solution at 37 degrees C. Permanent staining of the unused lenses was also obtained after immersion in the trypan blue solutions.

Aged↗

Determining the lowest trypan blue concentration that satisfactorily stains the anterior capsule.

PURPOSE: To determine the lowest concentration of trypan blue that will stain the anterior capsule satisfactorily to perform a safe continuous curvilinear capsulorhexis and to describe a staining technique using a dispersive viscoelastic material. SETTING: Cerrahpasa School of Medicine, University of Istanbul, Istanbul, Turkey. METHODS: Trypan blue 0.1% (Vision Blue) was diluted by half by adding an equal volume of balanced salt solution (BSS) in a stepwise pattern continuously until the concentration failed to stain the anterior capsule satisfactorily. After the dilution, 4 concentrations of the dye were obtained: 0.050%, 0.025%, 0.0125%, and 0.00625%. The volume of dye used for staining was 0.1 cc at all concentrations. Each concentration of the dye was applied using a classic air-bubble technique or a technique in which the dye was injected under sodium hyaluronate 3.0%-chondroitin sulfate 4.0% (Viscoat) onto the anterior lens surface without using an air bubble to reform the anterior chamber. Each diluted concentration was used in 10 eyes by the same surgeon, with 5 eyes having the air-bubble technique and 5 having the viscoelastic technique. The 0.1% concentration was used in 5 eyes, all having the viscoelastic technique. RESULTS: Trypan blue in concentrations as low as 0.0125% stained the anterior capsule satisfactorily. In addition, staining was possible under the Viscoat. The viscoelastic technique was faster, safer, and easier to perform than the air-bubble technique. CONCLUSIONS: As trypan blue is a potentially carcinogenic vital dye and its possible long-term side effects are unknown, the lowest effective concentration should be used. A concentration lower than 0.1% was effective in staining the anterior capsule even under dispersive viscoelastic material.

Capsulorhexis↗

Spontaneous disinsertion of a haptic from a 3-piece acrylic foldable intraocular lens after surgery.

A 49-year-old man with cataracts had uneventful phacoemulsification, continuous curvilinear capsulorhexis, and implantation of an MA30BA acrylic foldable intraocular lens (IOL) in the bag. One week later, 1 haptic spontaneously dropped off and the optic dislocated into the anterior chamber. The IOL was surgically removed and replaced with a new acrylic foldable IOL. Examination of the explanted IOL revealed that the loop hole was not created in the middle of the side face, leading to in vivo detachment of the haptic postoperatively.

Acrylic Resins↗

Nucleus cryoinversion for extraction of highly complicated cataracts.

We describe a technique for cataract extraction in vitrectomized eyes that uses secured removal of the nucleus with no manipulation of the capsular bag. After a large scleral tunnel is prepared and a capsulorhexis created, a 20-gauge retinal cryoprobe enveloped in a plastic or a silicone sleeve is introduced into the anterior chamber. The cryoprobe engages the nucleus by a "freeze-grip" and rotates it 180 degrees so that the nucleus is elevated into the anterior chamber with no force applied to the capsule and the cryoprobe supporting it from below. The cryoprobe is replaced by a vectis under the nucleus and with the help of another instrument from above, the nucleus is removed. Aspiration of cortical material under low-pressure fluid maintenance of the anterior chamber completes removal of the cataract. An intraocular lens is then implanted in the ciliary sulcus for maximum capsule support.

Capsulorhexis↗

Inflammation after implantation of hydrophilic acrylic, hydrophobic acrylic, or silicone intraocular lenses in eyes with cataract and uveitis: comparison to a control group.

PURPOSE: To compare the course of inflammation after small-incision cataract surgery with implantation of 1 of 3 types of foldable intraocular lenses (IOLs) in eyes with uveitis. SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: Seventy-four eyes with uveitis and cataract and 68 control eyes with cataract were prospectively selected to receive a foldable hydrophilic acrylic (Hydroview, Bausch & Lomb), hydrophobic acrylic (AcrySof, Alcon), or silicone (CeeOn 911, Pharmacia) IOL. All surgery was performed by the same surgeon using a standardized protocol: clear corneal incision, capsulorhexis, phacoemulsification, and in-the-bag IOL implantation. Preoperative and postoperative inflammation was evaluated by measuring aqueous flare preoperatively and 1, 3, 7, 28, 90, and 180 days after surgery using the Kowa FC-1000 laser flare-cell meter. All uveitic eyes were in remission for at least 3 months before surgery. RESULTS: In the uveitic eyes, there was no statistically significant difference in the postoperative course of flare and cell among the 3 IOL groups. Six months after surgery in uveitic eyes, flare values reached preoperative levels and the cell count was lower than preoperatively in all 3 IOL groups. Relative flare values were higher in the eyes with uveitis and a CeeOn 911 IOL; however, the difference between this group and the 2 acrylic IOL groups was not significant. CONCLUSIONS: There were no significant differences in inflammation after implantation of foldable IOLs in uveitic eyes. Although absolute flare values and cell counts in eyes with uveitis were higher than in control eyes, primarily because of a damaged blood-aqueous barrier (BAB), BAB recovery was similar between the 2 groups. The changes in the BAB indicate that foldable IOL implantation is safe in uveitic eyes.

Acrylic Resins↗

Pediatric cataract surgery with or without anterior vitrectomy.

PURPOSE: To evaluate after-cataract formation in children having cataract surgery with or without dry anterior vitrectomy and possible differences according to age. SETTING: St. Erik's Eye Hospital, Stockholm, Sweden. METHODS: This retrospective study comprised 85 eyes of 85 patients from 0 to 15 years old who had cataract surgery with or without anterior vitrectomy after the implantation of an intraocular lens (IOL). All patients had primary posterior capsulorhexis but no optic capture. Thirty-five patients received a heparin-surface-modified poly(methyl methacrylate) IOL (809C, Pharmacia & Upjohn) and 50 patients, a foldable acrylic IOL (AcrySof(R), Alcon). The records from follow-up visits at the patients' home clinics were used for analysis. RESULTS: Significantly fewer children were operated on for after-cataract if they had cataract surgery with anterior vitrectomy (P <.05). This applied to both IOL types. In the children older than 7 years in the AcrySof IOL group, there was no difference in the frequency of after-cataract surgery (P >.05). CONCLUSION: In children younger than 7 years with an AcrySof IOL, the rate of after-cataract surgery was significantly less in those who had an anterior vitrectomy at the time of cataract surgery (P <.05). In younger children, it is advantageous to perform cataract surgery with anterior vitrectomy to help prevent after-cataract formation; however, vitrectomy is not necessary in older children.

Acrylic Resins↗

Viscoanesthesia. Part III: removal time of OVD/viscoanesthetic solutions from the capsular bag of postmortem human eyes.

PURPOSE: To investigate and evaluate the removal time of various ophthalmic viscosurgical device (OVD)/viscoanesthetic solutions containing sodium hyaluronate 1.5% with different concentrations of lidocaine (0.5%, 1.0%, and 1.65%). SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Six postmortem human eyes were prepared per the Miyake-Apple posterior video technique. Capsulorhexis, hydrodissection/delineation, and nuclear emulsification were performed, followed by thorough cleaning of the capsular bag using an irrigation/aspiration (I/A) tip. The time and ease of removal of 4 solutions from the capsular bag were evaluated. The solutions were Ophthalin Plus (sodium hyaluronate, 15 mg/mL) and sodium hyaluronate 15 mg/mL mixed with lidocaine 0.5%, lidocaine 1.0%, and lidocaine 1.65%. The solutions were dyed with fluorescein to enhance visualization. After the capsular bag was filled with 1 of the solutions, a posterior chamber intraocular lens was implanted. The solution was then aspirated using an automated I/A device set at 250 mm Hg of aspiration. The time required to remove most and then all the material was recorded. RESULTS: The mean time required for removal of most of the Ophthalin Plus, viscoanesthesia 0.5%, viscoanesthesia 1%, and viscoanesthesia 1.65% solutions was 8.7 seconds +/- 2.1 (SD), 7.7 +/- 1.1 seconds, 9.7 +/- 0.6 seconds, and 6.3 +/- 1.5 seconds, respectively (P =.1). The mean time to remove all the solutions was 21.3 +/- 3.2 seconds, 19.7 +/- 2.5 seconds, 18.3 +/- 3.2 seconds, and 15.7 +/- 2.1 seconds, respectively (P =.166). No subjective difference in viscosity or consistency was found among the solutions. CONCLUSIONS: The addition of lidocaine to the OVD solution did not significantly alter the viscosity or consistency of the solution or change its removal time from the capsular bag.

Anesthetics, Local↗

Postoperative change in effective lens position of a 3-piece acrylic intraocular lens.

PURPOSE: To study the change in postoperative position of an angulated, 3-piece, foldable acrylic intraocular lenses (IOLs) and evaluate the effect of a sharp posterior optic edge compared with that of a round optic edge on the change in postoperative anterior chamber depth (ACD). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized intraindividual-comparison study comprised 104 eyes of 52 patients with age-related cataract. Patient received a sharp-edged Sensar OptiEdge AR40e IOL (Allergan Surgical) in 1 eye and a round-edged Sensar AR40 IOL in the other eye. Postoperative follow-up included ACD measurement by partial coherence interferometry and evaluation of the capsulorhexis area by standardized retroillumination photography at 1 day, 1 week, and 1 and 6 months. RESULTS: A decrease in ACD during the first postoperative week was followed by a small increase in ACD during the first 6 months. There was no significant difference between the sharp-edged group and the round-edged group. CONCLUSIONS: The angulated 3-piece acrylic IOLs showed significant forward movement over the first postoperative 6 months. Although the change in refraction was small, there was variability among patients. The sharp posterior optic edge design did not affect the IOL's movement in the capsular bag.

Acrylic Resins↗

Evaluation of corneal damage by combined phacoemulsification and passive efflux of silicone oil in vitrectomized eyes.

PURPOSE: To evaluate the effect on the corneal endothelium of phacoemulsification combined with passive silicone oil removal and intraocular lens (IOL) implantation under topical anesthesia after pars plana vitrectomy. SETTING: Department of Ophthalmology and Otolaryngology, University of Bari, Bari, Italy. METHODS: This retrospective study evaluated the corneal endothelium in 17 consecutive patients (17 eyes) who had phacoemulsification with transpupillary passive silicone oil washout (1300 centistokes) through a posterior capsulorhexis and single clear corneal incision and foldable acrylic IOL implantation. The findings were compared with those in a control group of 17 patients (17 eyes) who had phacoemulsification with acrylic IOL implantation through a single clear corneal incision. All procedures were performed by the same surgeon using topical anesthesia. The preoperative and postoperative endothelial cell densities, coefficient of variation (CV), and percentage of hexagonal cells at the corneal center and peripheral temporal position, evaluated by noncontact specular microscopy, were compared between the 2 groups. The central corneal thickness and occurrence of keratopathy were also noted. RESULTS: The mean phacoemulsification and total ultrasound times did not differ significantly between the 2 groups. At 6 months, the mean endothelial cell loss was 284.50 cell/mm(2) +/- 462.3 (SD) (11.2%) in the study group and 200.15 +/- 117.9 cell/mm(2) (8.3%) in the control group (P=.87, unpaired t test). There were no significant between-group differences in the increase in the mean CV and the percentage of hexagonal cells. The mean pachymetry remained at preoperative values, with no difference between groups. Keratopathy was not observed in any patient. CONCLUSIONS: Passive silicone oil efflux caused significant endothelial cell loss and changes in endothelial morphology. Nevertheless, these modifications were well tolerated and minimally different from the results of trauma caused by standard phacoemulsification with posterior chamber IOL implantation.

Acrylic Resins↗

In vitro model for the study of human posterior capsule opacification.

PURPOSE: To develop and evaluate a model for the organ culture of human lens capsules that reduces problems inherent in preexisting models for the study of in vitro posterior capsule opacification (PCO). METHODS: Human lenses (N = 110) were isolated from donor eyes and supported externally within a lens holder system by medical-grade cyanoacrylate glue, allowing visualization of the entire capsular bag. After capsulorhexis and lens extraction were performed, the capsule specimens were maintained at physiological conditions for up to 4 weeks. The area of lens epithelial cell (LEC) coverage over the posterior capsule surface was determined objectively on a daily basis using a graticule. Lens epithelial cell behavior was correlated with clinical data and other in vitro PCO models. RESULTS: Cyanoacrylate glue did not appear to be toxic to LECs at the concentration used. The amount of viable epithelium after nuclear extraction was dependent on the age and postmortem time of the specimen. Viable LEC cultures were obtained from eyes up to 9 days postmortem. The time from death to culture or from enucleation to culture did not influence LEC viability if it was fewer than 5 days. The LEC proliferation rates and confluence times were age dependent and correlated closely between pairs of eyes. CONCLUSIONS: Results show that the lens holder model is a more physiological method for supporting the capsule and is a robust, reproducible system for the study of LEC migration and proliferation. It allows visualization within the entire capsular bag. Intraocular lenses can be implanted in this system in a way that more closely resembles the in vivo scenario. This model can be used to evaluate therapeutic measures to prevent PCO.

Adolescent↗

Subluxated lens: phacoemulsification with iris hooks.

We describe a technique to manage subluxated cataracts with the use of 4 or 5 disposable nylon iris hooks placed on the capsulorhexis edge to support the lens and stabilize the capsular bag during phacoemulsification. The use of an endocapsular tension ring provides excellent centration of the capsular bag, enabling endocapsular intraocular lens (IOL) implantation. Sixteen eyes with zonular dialysis between 90 degrees and 180 degrees had surgery with this technique. The mean visual acuity significantly improved from 0.26 +/- 0.18 to 0.68 +/- 0.33 (P<.001). The surgeries were uneventful. Postoperative complications included cystoid macular edema 5 months after surgery in 1 eye and slight IOL dislocation with no symptoms detected 2 months after surgery in 4 eyes. The technique appears to be safe, ensuring a stable IOL with reduced surgical risks.

Aged↗

Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation.

PURPOSE: To evaluate the extent of capsular bag shrinkage after cataract surgery with intraocular lens (IOL) implantation and develop a regression formula to predict postoperative capsular bag size. SETTING: Eye Hospital, Johannes Gutenberg-University, Mainz, Germany. METHODS: The axial length (AL), anterior chamber depth, and corneal radius in 58 eyes were measured preoperatively. Cataract surgery was by phacoemulsification followed by implantation of a 3-piece, acrylic, posterior chamber IOL. The capsular bag diameter and anterior capsulorhexis were measured intraoperatively and 1 day and 1, 3, and 6 months postoperatively using a Koch capsule measuring ring (HumanOptics). RESULTS: The mean capsular bag size was 10.53 mm intraoperatively, 10.31 mm at 1 day, 9.62 mm at 1 month, 9.07 mm at 3 months, and 9.01 mm at 6 months. The mean capsular bag shrinkage over the entire postoperative period was 14.8% (P<.001). Of the parameters studied, only AL had a positive correlation with capsule shrinkage. The correlation was moderate but statistically significant (P =.001). CONCLUSIONS: A correlation was found between capsular bag shrinkage and AL. Using preoperative biometric data, a regression formula of moderate validity was determined to predict capsular bag shrinkage.

Acrylic Resins↗

Cumulative probability of neodymium: YAG laser posterior capsulotomy after phacoemulsification.

PURPOSE: To retrospectively analyze the cumulative probability of neodymium:YAG (Nd:YAG) laser posterior capsulotomy after phacoemulsification and to evaluate the risk factors. SETTING: Ando Eye Clinic, Kanagawa, Japan. METHODS: In 3997 eyes that had phacoemulsification with an intact continuous curvilinear capsulorhexis, the cumulative probability of posterior capsulotomy was computed by Kaplan-Meier survival analysis and risk factors were analyzed using the Cox proportional hazards regression model. The variables tested were sex; age; type of cataract; preoperative best corrected visual acuity (BCVA); presence of diabetes mellitus, diabetic retinopathy, or retinitis pigmentosa; type of intraocular lens (IOL); and the year the operation was performed. The IOLs were categorized as 3-piece poly(methyl methacrylate) (PMMA), 1-piece PMMA, 3-piece silicone, and acrylic foldable. RESULTS: The cumulative probability of capsulotomy after cataract surgery was 1.95%, 18.50%, and 32.70% at 1, 3, and 5 years, respectively. Positive risk factors included a better preoperative BCVA (P =.0005; risk ratio [RR], 1.7; 95% confidence interval [CI], 1.3-2.5) and the presence of retinitis pigmentosa (P<.0001; RR, 6.6; 95% CI, 3.7-11.6). Women had a significantly greater probability of Nd:YAG laser posterior capsulotomy (P =.016; RR, 1.4; 95% CI, 1.1-1.8). The type of IOL was significantly related to the probability of Nd:YAG laser capsulotomy, with the foldable acrylic IOL having a significantly lower probability of capsulotomy. The 1-piece PMMA IOL had a significantly higher risk than 3-piece PMMA and 3-piece silicone IOLs. CONCLUSIONS: The probability of Nd:YAG laser capsulotomy was higher in women, in eyes with a better preoperative BCVA, and in patients with retinitis pigmentosa. The foldable acrylic IOL had a significantly lower probability of capsulotomy.

Acrylic Resins↗

Capsulotomy diameter mark.

Recent improvements in intraocular lens (IOL) design and material delay posterior capsule opacification (PCO) after cataract surgery. However, studies have shown that without anterior capsule coverage of the IOL, PCO rates tend to increase. Surgeons have traditionally sized anterior capsulotomies without using a reference. The capsulotomy diameter mark is a convenient and inexpensive method to more consistently perform an anterior capsulorhexis that will allow anterior capsule overlap of the IOL optic.

Capsulorhexis↗