PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Development of a solid-phase microextraction method for direct determination of pentachlorophenol in paper and board samples: Comparison with conventional extraction method.

A solid-phase microextraction (SPME) method has been developed for the determination of pentachlorophenol (PCP) in paper and board samples. The analytical procedure involves direct extraction of PCP from paper and board samples and determination by gas chromatography with electron capture detection (GC-ECD). Two kinds of commercially available fibres; 100 microm polydimethylsiloxane (PDMS), apolar, and 85 microm polyacrylate (PA), quite polar, were evaluated to determine the extraction efficiency of pentachlorophenol. Parameters affecting the extraction process, such as temperature and time, were studied. Moreover, time of desorption and the effect of addition of salt were also investigated. The optimized procedure was applied to the analysis of pentachlorophenol (PCP) in five samples of virgin and recycled paper and board. The PCP content was determined by GC-ECD. To evaluate the effectiveness of the proposed method, it was compared with conventional extraction method with liquid-liquid extraction and derivatization. Detection limit of 0.015 microg/g for PCP in paper was achieved with a RSD of 14%.

Chemical Fractionation↗

Development of immunoaffinity solid phase microextraction probes for analysis of sub ng/mL concentrations of 7-aminoflunitrazepam in urine.

We report on the development of solid phase microextraction probes for drug analysis, prepared with antibodies specific for benzodiazepines covalently immobilized to the surface. In the technique, immobilized antibody probes are exposed to a sample containing the drug for 30 min. Extracted drugs are subsequently desorbed from the probes in 500 microL of methanolic desorption solution, which is dried, reconstituted in a small volume of injection solution and analysed by LC-MS/MS. The antibodies were characterized both before and after immobilization, to facilitate the rational selection of antibodies for such analyses. Polyclonal and monoclonal antibodies were compared as was the impact of affinity purification of the polyclonal antibody to isolate the drug-specific fraction. The probes were evaluated for utility in analyzing 7-aminoflunitrazepam at sub ng/mL concentrations in urine, which is expected to be found several days after a single oral dose of 2 mg of flunitrazepam. Such analyses are required in monitoring for abuse of this drug, both in terms of 'club drug' use and in cases of drug-facilitated sexual assault. In these cases drug concentrations in blood and urine are much lower than in chronic abuse cases and are difficult to analyse by conventional methods. The method developed has a limit of detection of 0.02 ng/mL, with accuracy ranging from 1% to 27% and precision (% R.S.D.) ranging from 2% to 10% between the lower and upper limits of quantitation for the analysis of 7-aminoflunitrazepam in urine. The dynamic range of the method is from 0.02 ng/mL, which is limited by the instrument sensitivity, to 0.5 ng/mL, which is approaching the capacity of the probes. This would allow for quantitative analysis of samples at concentrations below that measurable by many other methods for general benzodiazepines analysis from urine, and a highly selective screen for samples at higher concentrations. The method has similar limits of detection to the most sensitive literature methods specifically designed for such analysis but with the advantage of significantly simplified sample preparation. This simplification makes the technique more amenable for use by both professionals and non-professionals.

Algorithms↗

Solid-phase microextraction for determining the distribution of sixteen US Environmental Protection Agency polycyclic aromatic hydrocarbons in water samples.

A solid-phase microextraction (SPME) procedure has been developed for the determination of 16 US Environmental Protection Agency promulgated polycyclic aromatic hydrocarbons (PAHs). Five kinds of SPME fibers were used and compared in this study. The extracted sample was analyzed by gas chromatography with flame ionization detection or mass spectrometry. Parameters affecting the sorption of analyte into the fibers, including sampling time, thickness of the fiber coating, and the effect of temperature, have been examined. Moreover, the feasibility of headspace SPME with different working temperatures was evaluated. The method was also applied to real samples. The 85-microm polyacrylate (PA) and 100-microm poly(dimethylsiloxane) (PDMS) fibers were shown to have the highest affinities for the selected PAHs. The PA fiber was more suitable than the PDMS fiber for the determination of low-ring PAHs while high sensitivity of high-ring PAHs was observed when a 100-microm PDMS fiber was used. The method showed good linearity between 0.1 and 100 ng/ml with regression coefficients ranging from 0.94 to 0.999. The reproducibility of the measurements between fibers was found to be very good. The precisions of PA and PDMS fibers were from 3 to 24% and from 3 to 14%, respectively. Headspace SPME is a valid alternative for the determination of two- to five-ring PAHs. A working temperature of 60 degrees C provides significant enhancement in sensitivity of two- to five-ring PAHs having low vapor pressures (>10(-6) mmHg at 25 degrees C) (1 mmHg = 133.3 Pa) and low Henry's constants (>10 atm ml/mol) (1 atm = 1.01 x 10(5) Pa).

Chromatography, Gas↗

High-performance polyethylene glycol-coated solid-phase microextraction fibers using sol-gel technology.

The sol-gel method is applied for the preparation of solid-phase microextraction (SPME) fibers. An electron microscopy experiment suggested a porous structure for Superox-4 (polyethylene glycol, PEG) coating. SPME-GC analyses provided evidence that the sol-gel fibers have some advantages, such as high velocities of mass transfer, efficient extraction rates. high thermal stability, long life span, and spacious range of application for both polar and non-polar analytes. Efficient SPME-GC analyses of benzene-toluene-ethylbenzene-xylenes, phenols, phthalic diesters, naphthalene congeners and pesticides were achieved using sol-gel-coated PEG fibers.

Chromatography, Gas↗

Coupling solid-phase microextraction and high-performance liquid chromatography for direct and sensitive determination of halogenated fungicides in wine.

A solid-phase microextraction (SPME) method coupled to high-performance liquid chromatography with diode array detection (HPLC-DAD) for the analysis of six organochlorine fungicides (nuarimol, triadimenol, triadimefon, folpet, vinclozolin and penconazole) in wine was developed. For this purpose, polydimethylsiloxane-divinylbenzene-coated fibers were utilized and all factors affecting throughput, precision, and accuracy of the SPME method were investigated and optimized. These factors include: matrix influence, extraction and desorption time, percentage of ethanol, pH, salt effect and desorption mode. The performed analytical procedure showed detectability ranging from 4 to 27 microg l(-1) and precision from 2.4 to 14.2% (as intra-day relative standard deviation, RSD) and 4.7-25.7% (as inter-day RSD) depending on the fungicide. The results demonstrate the suitability of the SPME-HPLC-DAD method to analyze these organochlorine fungicides in red wine.

Chromatography, High Pressure Liquid↗

Solid-phase microextraction using fused-silica fibers coated with sol-gel-derived hydroxy-crown ether.

A novel solid-phase microextraction (SPME) fiber containing hydroxydibenzo-14-crown-4 (OH-DB14C4)/hydroxy-terminated silicone oil (OH-TSO) was first prepared by a sol-gel method and investigated for the determination of phenols. The possible mechanism is discussed and confirmed by IR spectra. The coating has stable performance in high temperature (to 350 degrees C) and solvents (organic and inorganic) due to the chemical binding between the coating and the fiber surface. The addition of crown ether enhances the polarity of the coating compared with that of the sol-gel OH-terminated silicone oil fiber and, accordingly, provides higher extraction efficiency for polar phenolic compounds. On the other hand, OH-terminated silicone oil in the coating can not only increase the length of network but also help to spread the stationary phase on the silica surface uniformly. The fluorescence microscopy experiment suggests the benefit the more uniform surface of the sol-gel-derived OHDB14C4/OH-TSO fiber in comparison with sol-gelderived OH-DB14C4 fiber. Some parameters of the SPME fiber for the determination of phenols were investigated. Limits of detection of the phenols are below 1.0 ng/mL, and the precisions are from 2.9 to 4.6% (n = 6). Linear ranges were found to be 0.1-10 microg/mL The sensitivity of the method is enhanced at a low-pH level (pH approximately 1) and with the addition of salt. The method was applied to the analysis of wastewater sample from a paper mill.

Journal Article↗

Headspace solid phase microextraction applied to the analysis of organophosphorus insecticides in strawberry and cherry juices.

A method based on a headspace solid phase microextraction (HS-SPME) technique followed by gas chromatography with flame thermionic and mass spectrometric detection was developed for the determination of seven organophosphorus (OPs) insecticide residues in strawberry and cherry juice samples. The extraction capacities of four fiber coatings, polyacrylate (PA 85 microm), poly(dimethylsiloxane) (PDMS 100 microm), carbowax-divinylbenzene (CW-DVB 65 microm), and poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB 65 microm), have been studied and compared. The method was developed using spiked strawberry and cherry juices in a concentration range of 0.5-50 microg/L. The PDMS 100 microm fiber showed good extraction efficiency for the target compounds. An increase in the extraction efficiency of OP insecticides was observed when the parameters affecting the HS-SPME process such as temperature, extraction time, salt additives, stirring rate, pH, and effect of dilution were optimized. Good linearity of compounds was observed in the tested concentration range. The relative standard deviations were found to be <20%. The limits of detection were between 0.025 and 0.050 microg/L. The mean relative recoveries ranged from 82 to 102%.

Beverages↗

Evaluation of solid-phase microextraction for the isotopic analysis of volatile compounds produced during fermentation by lactic acid bacteria.

The use of solid-phase microextraction (SPME) coupled with isotope ratio mass spectrometry (IRMS) for the analysis of flavor compounds produced by lactic acid bacteria has been evaluated using both liquid and headspace sampling modes. Initially, it was necessary to optimize the conditions for the SPME extraction of flavors-diacetyl and acetoin-in standard aqueous solutions. The effects of salt, headspace versus liquid sampling, and coating phase were tested. Second, the suitability of the coupling of SPME and gas chromatography-combustion interface-IRMS (GC-C-IRMS) for the determination of delta(13)C values was assessed. It is shown that neither the analyte concentration nor the period of fiber exposure has an effect on the delta(13)C values. Finally, having verified that there are no matrix effects from the fermentation medium, it is reported for the first time that flavor compounds can be extracted directly from culture supernatant by SPME and their delta(13)C values can be obtained by GC-C-IRMS.

Acetoin↗

Solid-phase microextraction in the analysis of food taints and off-flavors.

Selected food taints and off flavors, for which solid phase microextraction (SPME) has been used as a method for volatiles isolation, are the subject of review. Compounds responsible for musty and earthy odor off-flavors and taints in foods are discussed. This group contains haloanisoles, geosmin, and methylisoborneol. Chlorophenols are discussed as precursors of chloroanisoles and compounds impairing the flavor of food. Also described are volatile phenolic compounds responsible for medicinal off flavors, mainly ethyl phenols and vinyl phenols. Sulfur compounds that contribute to off-flavor are also discussed. Finally, a group of volatile compounds being the products of lipid oxidation are summarized. A short review of the formation, occurrence, and information on odor properties of all of these groups of compounds is given. Examples of SPME use for the analysis of compounds belonging to all described groups are shown. Elaboration of method parameters, fiber selection, experimental conditions, and quantitation of compounds are subjects of interest. Also, applications of SPME as a method for introduction of volatiles in mechanical olfaction technologies are shortly outlined.

Food Analysis↗

Trace element determination by combining solid-phase microextraction hyphenated to elemental and molecular detection techniques.

The state of the art of analytical procedures based on solid-phase microextraction (SPME) and its applications to tin, mercury, arsenic, antimony, chromium, selenium, and lead determination in abiotic and biotic matrixes are critically reviewed from 1994 to present. First, sample pretreatment prior to SPME is evaluated, including a description of the most usual leaching procedures for sediment, soil, and biological samples. Because most organometallic species lack volatility, a derivatization step is mandatory prior to gas chromatographic (GC) determination, except for the volatile organometallics that can be directly extracted from the sample headspace or liquid phase by SPME. The most common derivatization procedures used in alkylation and hydridization reactions used for mercury, lead, and tin, as well as other procedures for the determination of total chromium and arsenic [i.e., trifluoroacetylacetonates for chromium (III) and thioglycol methylate for organic arsenic species] are reviewed. Critical variables usually evaluated along with the method development to improve the sensitivity of the extraction methods based on SPME, such as sampling size, stirring procedures, sampling temperature and pressure, polymer coating, and thermal desorption are reviewed. In addition, figures of merit of the different detection systems used in SPME combined with GC are evaluated. The validation of the reported analytical procedures with reference materials are also discussed in terms of precision and accuracy. Finally, future developments in the application of SPME to speciation are highlighted. Moreover, the capability of SPME automation for the derivatization-extraction procedures are also presented.

Journal Article↗

Alumina-based fiber for solid phase microextraction of alcohols from gaseous samples.

On the basis of the affinity of alumina towards hydroxyl functional groups, a solid phase microextraction (SPME) fiber was constructed using alumina powder and poly(vinyl chloride) (PVC). Different compositions were tested and alumina:PVC (97:3) was selected as an optimun composition. A piece of silver wire was used as fiber support. The fiber producing was simple and could be completed in a few minutes. The mechanical durability of the fiber was so good that only a single fiber was used during this study. Ethanol, 1-butanol, 2-butanol, 1-pentanol, 2-pentanol and cyclohexanol were selected as target analytes. Finally, ethanol concentration in the fruit juices and vinegar was measured using SPME-capillary gas chromatography followed by flame ionization detection.

Journal Article↗

Partitioning of selected environmental pollutants into organic matter as determined by solid-phase microextraction.

Partitioning/sorption of selected environmental pollutants (PCBs, organochlorine insecticides, triazine and amide herbicides) into dissolved humic acids (HA), soil and mineral substances was evaluated by measuring their free concentrations by solid-phase microextraction (SPME). Compounds were chosen to cover a wide range of logK(ow) (2.2-7.6). Two different types of partitioning behaviour for dissolved HA were observed. Compounds with logK(ow)>5 partitioned almost instantly into HA fraction and the remaining free fraction remained rather constant. LogK(HA) and logK(DOC) were calculated and found to be similar for commercial HA, HA standard and isolated HA. The behaviour of these compounds in soil suspension was similar, but strong sorption on CaCO3 and Florisil was also noticed. For compounds with logK(ow)<5, we have not noticed significant changes in free concentrations in HA solutions over time. In soil suspension, however, some sorption/partitioning was observed over time for some compounds, but it was matching the sorption on CaCO3 and Florisil.

Environmental Monitoring↗

Determination of fluoroacetic acid in water and biological samples by GC-FID and GC-MS in combination with solid-phase microextraction.

A novel procedure has been developed for determination of fluoroacetic acid (FAA) in water and biological samples. It involves ethylation of FAA with ethanol in the presence of sulfuric acid, solid-phase microextraction of the ethyl fluoroacetate formed, and subsequent analysis by GC-FID or by GC-MS in selected-ion-monitoring mode. The detection limits for FAA in water, blood plasma, and organ homogenates are 0.001 microg mL(-1), 0.01 microg mL(-1), and 0.01 microg g(-1), respectively. The determination error at concentrations close to the detection limit was less than 50%. For analysis of biological samples, the approach has the advantages of overcoming the matrix effect and protecting the GC and GC-MS systems from contamination. Application of the approach to determination of FAA in blood plasma and organ tissues of animals poisoned with sodium fluoroacetate reveals substantial differences between the dynamics of FAA accumulation and clearance in rabbits and rats.

Animals↗

Quantitative analysis of benzene, toluene, and xylenes in urine by means of headspace solid-phase microextraction.

A simple method for benzene, toluene, and xylenes (BTX) quantitative analyses in human urine was developed, using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled to mass spectrometry detection in the single ion monitoring mode. The developed method is solventless, non-invasive, requires small volume of sample (1 ml), shows high selectivity, sensitivity, repeatability, and linearity (correlation coefficients >0.998), providing a useful alternative to assess human exposure to BTX compounds due to occupational reasons or eventual exposure to organic solvents. Detection limit varies from 0.28 to 0.5 ppb (v/v).

Benzene↗

Hollow fiber membrane-protected solid-phase microextraction of triazine herbicides in bovine milk and sewage sludge samples.

A porous polypropylene hollow fiber membrane (HFM)-protected solid-phase microextraction (HFM-SPME) procedure in conjunction with gas chromatography/mass spectrometric analysis for use in the determination of triazine herbicides in bovine milk samples is described. A 65-microm polydimethylsiloxane-divinylbenzne (PDMS-DVB) SPME fiber was protected by an HFM. HFM-SPME experimental parameters such as fiber type, extraction time, extraction temperature and salt concentration were investigated and optimized. The relative standard deviations for the reproducibility of the optimized HFM-SPME method varied from 4.30 to 12.37%. The correlation coefficients of the calibration curves were between 0.9799 and 0.9965 across a concentration range of 0-200 microg l(-1). The method detection limits for triazines in bovine milk were in the range of 0.003-0.013 microg l(-1) and limits of quantification were in the range of 0.006-0.021 microg l(-1). The suitability of HFM-SPME was extended to the analysis of the herbicides in sewage sludge samples. The results demonstrate that HFM-SPME was an efficient pretreatment and enrichment procedure for complex matrices.

Animals↗

Headspace solid-phase microextraction gas chromatography-mass spectrometry method for the identification of cosmetic ingredients causing delamination of packagings.

A headspace solid-phase microextraction gas chromatography-mass spectrometry (HS-SPME-GC-MS) method using a 75 microm Carboxen polydimethylsiloxane fibre was used to identify volatile compounds of cosmetic formulations responsible for causing loss of adhesion between layers of multilayer packagings. To obtain the sample, the sachet with the product was kept in an oven at 40 degrees C in order to favour the migration of the aggressive compounds to the inner layers. Then the sachet was manually delaminated and the aluminium/polyester and polyethylene layers were analysed. The cosmetic product was also analysed by HS-SPME-GC-MS. Several compounds used in the cosmetic industry such as perfumes or fixing agents were detected in the inner layers of the laminated material, showing the migration of them through the layer in contact with the product (polyethylene). Phenoxy ethanol, beta-linalool, menthol and p-propenylanisole are suspected to be responsible for the loss of adhesion. In order to provide a complete overview of the cause of the aforementioned phenomenon, the packaging material was exposed to the cosmetic products in order to measure the decrease of the adhesion strength with time. It was observed that the product with a higher phenoxy ethanol concentration caused a higher loss of adhesion strength. The results obtained showed that this method is suitable for identifying aggressive compounds in cosmetic products, as well as for giving prior information about which products may be problematic for packaging in sachets.

Absorption↗

Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography-mass spectrometry.

A solid-phase microextraction (SPME) method for the simultaneous determination of a large number of pesticides (46) with a wide range of polarities and chemical structures (organochlorine, organophosphorous, triazines, pyrethroids and others) in water samples by GC-MS has been developed. Three different fibres and parameters that influence the extraction and desorption efficiency were studied. The selected conditions were: a 60 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 45 min of extraction time, sample agitation and temperature control at 60 degrees C; neither pH adjustment nor ionic strength correction were applied. Good detection limits, linearity and repeatability were obtained with this method for the 46 pesticides studied. The method was validated for 29 pesticides following the recommendations of the international norm ISO/IEC 17025 including the calculation of the uncertainties. The detection limits ranged from 4 to 17 ng l(-1). Furthermore, repeatability (6.9-20.5%) and intermediate precision (4.5-19.7%) were shown to be satisfactory. To validate matrix effects for drinking and surface water analytical recoveries were calculated for these matrices. The accuracy of the method was also evaluated by participating in a proficiency inter-laboratory test.

Gas Chromatography-Mass Spectrometry↗

Optimisation of alachlor solid-phase microextraction from water samples using experimental design.

We have tested screening and response surface experimental designs to optimise the solid-phase microextraction (SPME) of the widely used herbicide alachlor. Extraction time and sample volume were the only statistically significant factors from those studied. In the final optimised conditions the procedure was applied to the SPME-HPLC analysis of alachlor in spiked water samples with excellent figures of merit.

Acetamides↗