PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Visceral adipose tissue and low-density lipoprotein particle size in middle-aged versus young men.

Age is associated with increased deposition of visceral adipose tissue. We examined whether this age-related change in regional adipose tissue distribution had an impact on low-density lipoprotein (LDL) particle size. For this purpose, the plasma lipoprotein-lipid profile, including LDL peak particle diameter as determined by gradient gel electrophoresis, was assessed in 38 young men (aged 26.4 +/- 4.2 years, mean +/- SD) and compared with 40 middle-aged men (55.9 +/- 6.2 years). Middle-aged men had higher values for total body fat and visceral adipose tissue area as measured by computed tomography than young men (P < .001). Although significant differences were noted between the two age groups for plasma cholesterol, triglyceride (TG), apolipoprotein B (apo B), LDL cholesterol, and LDL apo B, as well as the cholesterol to high-density lipoprotein (HDL) cholesterol ratio (P < .001), no difference was found for LDL peak particle size between young and middle-aged men. While visceral adipose tissue was a significant correlate of plasma lipoprotein levels, the fasting TG concentration was the best predictor of LDL particle size, and the regression of TG levels on LDL peak particle diameter was not different between the two age groups. These results suggest that middle-aged men are characterized by an increased concentration of LDL particles (reflected by increased LDL apo B levels) but not by a reduced LDL peak particle size compared with young men. It is therefore proposed that in the absence of an important age-related change in TG levels, age per se is associated with an increased concentration of atherogenic LDL particles rather than a reduction of LDL particle diameter.

Abdomen↗

Entry port selection for detecting particle size differences in metered dose inhaler formulations using cascade impaction.

Different sized glass entry ports were evaluated for their drug collection efficiency during aerodynamic particle sizing of metered dose inhalers (MDIs) using cascade impaction. A comparison was made between collection efficiency in the entry port, impactor plates, and filter using the 1 L, 2 L, and 20 L glass entry ports and the USP and twin impinger entry ports. Entry port losses were dependent on the size of entry port selected, with 1-2 L ports showing optimal recovery on impactor plates, compared to the USP entry port. The 1 L entry port was further compared with the USP entry port in its ability to discriminate between subtle changes in particle size distribution (PSD) in an investigational hydrofluoroalkane (HFA)-based MDI formulation. Deliberately induced differences during product manufacture were easily detected using the 1 L entry port with the Andersen cascade impactor. The USP port was unable to distinguish among products with small particle size differences. An alternative entry port such as the 1 L glass entry port used in this study may provide better means of characterizing the PSD during formulation development and stability testing of MDIs.

Aerosols↗

Predictors of low-density lipoprotein particle size in a high-risk African-American population.

A predominance of small, dense, low-density lipoprotein particles (pattern B) has been associated with increased cardiovascular risk independent of absolute cholesterol levels in primarily white populations. Because of the putative association of pattern B with increased risk, some investigators have proposed that routine measurement of low-density lipoprotein particle size may be beneficial for cardiovascular risk assessment. Because no studies have specifically examined this possibility in African-Americans, it remains unclear whether measurement of low-density lipoprotein particle size adds information beyond that of traditional lipid risk factors. We compared standard lipid profile measurements with extended measurements concurrently in an apparently healthy, high-risk population of African-American siblings of patients who had premature cardiovascular disease. We determined the extent to which patients who had pattern B would be identifiable from the usual lipid profile. A high triglyceride level alone was a strong independent correlate of pattern B. In subjects whose triglyceride level was >/=150 mg/dl, 67% had pattern B, whereas only 17% of subjects whose triglyceride level was <150 mg/dl had pattern B. The area under the receiver-operating characteristic curve was 0.77. Our data suggest that the standard lipid profile, primarily fasting triglyceride measurement, appears to be a useful surrogate for direct measurement of particle size in a high-risk African-American population.

Adult↗

Effects of forage particle size and grain fermentability in midlactation cows. I. Milk production and diet digestibility.

Our study investigated the effects of, and interactions between, level of dietary ruminally fermentable carbohydrate (RFC) and forage particle size on milk production, nutrient digestibility, and microbial protein yield for dairy cows fed one level of dietary NDF. Eight cows (61 days in milk) were assigned to four treatments in a double 4 x 4 Latin square. Treatments were arranged in a 2 x 2 factorial design; finely chopped alfalfa silage (FS) and coarse alfalfa silage (CS) were combined with concentrates based on either dry cracked shelled corn (DC; low RFC) or ground high-moisture corn (HMC; high RFC). Diets were fed ad libitum as a total mixed rations with a concentrate to forage ratio of 61:39. Diets based on DC had a predicted NEL content of 1.73 Mcallkg dry matter (DM), while HMC diets contained 1.80 Mcal/kg DM. Diets averaged 18.7% CP, 24.0% NDF, 18.3% ADF, and 27.4% starch on a DM basis. Mean particle size of the four diets was 6.3, 2.8, 6.0, and 3.0 mm for DCCS, DCFS, HMCCS, and HMCFS, respectively. Increasing level of RFC decreased dry matter intake (DMI) from 25.0 to 23.8 kg/ d and organic matter intake from 22.3 to 21.1 kg/d, but intake was not affected by particle size. Milk production averaged 44.0 and 26.8 kg/d solids corrected milk (SCM) and was not affected by diet, but increasing level of RFC tended to increase milk yield. Efficiency of milk production, expressed as SCM/DMI, increased from 1.06 to 1.14 when level of RFC was increased. Milk composition or yield of milk components was not affected by diet, and averaged 3.53% fat, 3.11% protein, 1.55 kg/d fat, and 1.36 kg/d protein. Total tract digestibility of DM and OM increased from 71.4 to 73.0% and 72.4 to 76.1% for DM and OM, respectively, when level of RFC was increased. Total tract digestibility of fiber was unaffected by diet, but total tract starch digestibility increased from 93.1 to 97.4% when HMC replaced DC. Total urinary excretion of the purine derivatives uric acid and allantoin increased from 415 to 472 mmol/d when level of RFC was increased, and calculated microbial N supply increased from 315 to 365 g/d. When expressed as per kilogram of digestible OMI, increasing level of RFC tended to increase microbial N supply (20.4 vs. 22.2 g/kg). Cow productivity was not affected by forage particle size and ruminally fermentable carbohydrates in this study.

Allantoin↗

Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols.

PURPOSE: To study the effect of particle size, air flow and inhaler type on the dispersion of spray dried mannitol powders into aerosols. METHODS: Mannitol powders were prepared by spray drying. The solid state properties of the powders were determined by laser diffraction, X-ray powder diffraction, scanning electron microscopy, freeze fracture, Karl Fischer titration and gas pycnometry. The powders were dispersed using Rotahaler and Dinkihalerg, connected to a multistage liquid impinger at different air flows. RESULTS: Three crystalline mannitol powders with primary particle size (MMD) 2.7, 5.0, 7.3 microm and a similar polydispersity were obtained. The particles were spherical with a density of 1.5 g/cm3 and a moisture content of 0.4 wt.%. At an air flow of 30 L/min all the powders were poorly dispersed by both inhalers. With the Rotahaler increasing the flow (60-120 L/min) increased the fine particle fraction (FPF) in the aerosols for the 2.7 microm powder, and decreased the FPF for the 7.3 microm powder; whereas the FPF for 5.0 microm powder was unaffected. With the Dinkihaler, all the powders were near complete dispersion at > or = 60 L/min. CONCLUSIONS: The FPF in the mannitol powder aerosols was determined by an interplay of the particle size, air flow and inhaler design.

Aerosols↗

Lipoprotein lipase prevents the hepatic lipase-induced reduction in particle size of high density lipoproteins during incubation of human plasma.

Human plasma lipoproteins or human whole plasma have been incubated in vitro with canine hepatic lipase (HL) and bovine milk lipoprotein lipase (LPL) to determine the effects of lipases on the particle size distribution of HDL. Confirming previous reports, HL preferentially hydrolysed high density lipoprotein (HDL) triacylglycerol while LPL hydrolysed predominantly very low density lipoprotein (VLDL) triacylglycerol; however, neither lipase altered HDL particle size unless both VLDL and cholesteryl ester transfer protein (CETP) were present. Under these conditions HL promoted marked reduction in HDL particle size in a process dependent on the concentration of VLDL triacylglycerol while LPL was virtually without effect. When both LPL and HL were included in the same incubation, however, LPL prevented the effects of HL. These results are consistent with a proposition that HL has a direct effect on HDL particle size in a process which is dependent on concurrent lipid transfers between HDL and VLDL and that LPL reduces the effect of HL by reducing the concentration of VLDL triacylglycerol.

Carrier Proteins↗

Metered-dose inhalers, I: Drug content and particle size distribution of beclomethasone dipropionate.

Four commercially available beclomethasone metered dose inhalers were analyzed for both spray content uniformity and particle size. The drug contents of primed and unprimed sprays collected at the beginning of the lifetime of the canister were not significantly different from those collected throughout the experiment. Particle size analysis of the four products using the Andersen Cascade Impactor Mark II showed that the distribution profiles were not identical. An existing HPLC method was modified to quantitate single sprays for content uniformity and to measure the amount on an impactor stage for particle sizing.

Administration, Inhalation↗

A logical stepwise approach to laser diffraction particle size distribution analysis methods development and validation.

In this study, a logical, stepwise, efficient approach was used to develop and validate particle size distribution analysis methods for 58 different pharmaceutical bulk powders in a timely fashion. Image analysis was used to determine particle morphology and laser diffraction particle size distribution analysis was used to evaluate the dispersion medium, dispersion concentration, sonication time, and dispersion stability. Ruggedness validation was performed, by two different analysis, on different days, with different instruments on two preparations each of two different lots of material. It was determined that if the relative standard deviation (RSD) of the median volume diameters (d50) of the four preparations for each lot was below 20%, the method was suitably rugged for use in a quality control setting. Data for methyldopa, metoprolol tartrate, and metronidazole are presented as typical method validation results for three different modes of analysis. Data at three points (d10, d50, and d90) on the distributions were tabulated and evaluated for all 58 methods validated. The median volume diameter (d50) was found to be adequate for method validation. The approach rapidly generated valid, reproducible particle size distribution analysis methodology.

Chemistry, Pharmaceutical↗

Biokinetics of inhaled 239PuO2 in the beagle dog: effect of aerosol particle size.

This study was designed to measure the effect of aerosol particle size on the deposition, retention, excretion and translocation of 239Pu inhaled as the dioxide by Beagle dogs. To address these questions, young adult male and female Beagle dogs received single brief inhalation exposures to one of three monodisperse aerosols of 239PuO2 having sizes of 0.72, 1.4 or 2.8 microns activity median aerodynamic diameter (AMAD). Periodic collections of urine and faeces were made for each dog until sacrifice at times ranging from 4 hours to 2 years after exposure. The results indicate long term retention of a substantial percentage of the initial pulmonary burden (IPB), and that the retention was affected by particle size. The percentage of the initial pulmonary lung burden retained in the long term component and its effective half time (TE) were 90 per cent with TE = 680 days for the 0.72 micron AMAD aerosol, 68 per cent with TE = 1400 days for the 1.4 microns AMAD aerosol and 82 per cent with TE = 1800 days for the 2.8 microns AMAD aerosol. The major route of elimination of 239Pu from lung was via the faeces, but significant amounts were also translocated to thoracic lymph nodes (approximately 15 per cent IPB by 2 years). Small amounts were translocated to liver (0.2 per cent IPB) and skeleton (0.1 per cent IPB) by 2 years after exposure. The average alpha-radiation dose to the lung was projected to be twice as large for the 2.8 microns AMAD group as for the 0.72 micron AMAD group at 10 years after exposure.

Aerosols↗

Effects of compression force, particle size, and lubricants on dissolution rate.

The effects of compression force, particle size, and lubricant concentration on the dissolution rates of compressed disks of salicylic acid, aspirin, and an equimolar mixture of aspirin and salicylic acid were investigated. Compression forces from 450 to 9100 kg had no effect on dissolution rates. With 5% starch incorporated into an equimolar mixture of aspirin and salicylic acid, the dissolution rates were independent of compression forces from 910 to 9100 kg. A 10-fold change of particle size of the materials being compressed did not affect the dissolution rates. An increase in the concentration from 0.1 to 5% of calcium stearate, glyceryl monostearate, magnesium stearate, and stearic acid progressively slowed the dissolution rate. An increase in the concentration from 0.1 to 5% talc and polyethylene glycol 4000 did not affect the dissolution rates. An increase in the concentration of starch from 0.1 to 5% progressively increased the dissolution rates.

Aspirin↗

The effect of sintered beta-dicalcium pyrophosphate particle size on newborn Wistar rat osteoblasts.

During recent years, sintered dicalcium phosphate (SDCP) has been shown to be an effective artificial bone filler for repairing bone defects. The goal of this study was to elucidate the effect of SDCP particle size on osteoblasts. Osteoblasts were mixed and cultured with various sized SDCP particles (0.5-3.0, 37-63, 177-250, and 420-841 microns) for 1 h, 3 h, 1 day, 3 days, and 7 days and then analyzed. The results show that the adding of smaller sized SDCP particles (0.5-3.0 and 37-63 microns) into osteoblast culture can significantly affect the cell counts of osteoblasts. The secretion of transforming growth factor-beta 1, alkaline phosphatase, and prostaglandin E2 in culture medium increased significantly. The changes were most significant and persisted longer in smaller particle groups. Small sintered dicalcium phosphate particles can inhibit the proliferation of the osteoblasts. The inhibitory effects of the smaller sized SDCP particles on the osteoblasts were mediated by the promotion of osteoblast differentiation and the increased synthesis of prostaglandin E2.

Alkaline Phosphatase↗

Racial differences in low-density lipoprotein particle size in families at high risk for premature coronary heart disease.

OBJECTIVE: Although small, dense low-density lipoprotein (LDL) has been implicated in atherogenesis and coronary heart disease (CHD) events, little is known about possible racial differences in LDL particle size. This study was designed to examine racial differences in the prevalence of small, dense LDL among 159 African-American and 477 White siblings of persons with premature (<60 years of age) CHD. METHODS AND RESULTS: This study examined fasting levels of total cholesterol, LDL cholesterol, high-density lipoprotein cholesterol, apolipoprotein B (ApoB), apolipoprotein A-1, and triglycerides, as well as factors known to be associated with small, dense LDL, including age, sex, obesity, hypertension, and diabetes. Relative LDL particle size was defined by the LDL cholesterol to ApoB ratio. Direct measurement of LDL particle size was obtained by proton NMR spectroscopy in a subset of 64 siblings. Despite similar levels of total and LDL cholesterol, White siblings were more likely to have low LDL cholesterol to ApoB ratios, indicative of atherogenic small, dense LDL, compared with African-American siblings. Multiple logistic regression analysis predicting the presence of LDL cholesterol/ApoB < or = 1.0 demonstrated that race (P = .009), triglyceride level (P = .0001), and diabetes (P = .02) were independent predictors, controlling for age and all other variables. Direct measurement of LDL particle size by NMR spectroscopy supported these findings. CONCLUSION: These findings provide the first known evidence that White individuals from a population at high risk for premature CHD have a greater probability of having a preponderance of small, dense LDL particles than do African Americans, independent of triglyceride levels, and despite comparable levels of total and LDL cholesterol.

Adult↗

Effects of particle size, organic matter and ionic strength on the phosphate sorption in different trophic lake sediments.

The trophic status and development of lake system is significantly influenced by the phosphate sorption at the sediment-water interface. The effects of organic matter, particle size and ionic strength on the phosphate sorption by sediments were investigated in this study. The results show that maximum phosphate sorption capacity (Qmax), equilibrium phosphate concentration (EPC0), phosphate sorption efficiency (k) and phosphate sorption rate decreased as particle size increased for all the studied sediments. But the reliable desorbed phosphorus (RDP) increased. Qmax, EPC0, k and RDP of different particle size fractions varied and there were no obvious differences among different trophic lake sediments. Qmax, EPC0 increased while k and RDP decreased as the pollution level of lake sediment increased. The phosphate sorption mainly occurred within 0.5 h. Power function and simple Elovich models were the best kinetic models for the phosphate sorption of the different particle size fractions. Qmax and phosphate sorption rate decreased with the decreasing of organic matter content of sediments and the increasing of ionic strength. This study suggests that ionic strength and organic matter had similar effects on the phosphate sorption for different trophic lake sediments.

Absorption↗

Deposition and dispersion of aerosols in the airways of the human respiratory tract: the effect of particle size.

Small volumes of aerosols (boluses) were inspired predominantly into the conducting airways of human lungs with a fast operating valve system, injecting preselected aerosol volumes near the end of a clean air inhalation. Particle recovery and bolus dispersion in the exhaled air after various periods of breathholding were investigated by measuring aerosol number concentration directly in front of the mouth with a laser photometer. Inspired and expired flow rates were measured with a pneumotachograph. The effect of particle size on these measurements has been investigated using aerosol particles with aerodynamic diameters (dae) between 0.9 and 5 microns. For aerosol particles smaller than 2 microns, bolus dispersion increases with increasing periods of breathholding (tb). After reaching a maximum, dispersion decreases with even longer tb. An increase in particle size yields a smaller increase in dispersion during the first seconds of breathholding while it is not changed significantly without breathhold. Particle losses during inhalation and exhalation increases with particle size. However, with increasing periods of breathholding, the losses of the smaller particles (less than 1.5 microns) were found to be much higher than expected theoretically, implying particle losses by sedimentation in the same airway structures. The small aerosol particles are deposited in smaller airways than bigger particles. These observations can be explained by cardiogenic mixing during periods of breathholding by pulsatile flow oscillations and confirm measurements with enhanced heart rate as described in an earlier paper. Small particles with restricted settling velocities remained longer in an airborne state in the airways and this leads to a more efficient cardiogenic mixing.

Administration, Inhalation↗

Supramicron-sized particle clearance from alveoli: route and kinetics.

Particles inhaled and deposited in the alveoli of the lung, i.e., distal to the tracheobronchial mucociliary escalator, may theoretically be cleared by several routes, including solubilization, lymphatic drainage, and the mucociliary pathway. We studied the clearance routes and kinetics of an inert insoluble carbonized polystyrene particle of supramicron size (2.85 micron count median diameter) tagged with 57Co (half-life 270 days) in the adult unanesthetized sheep. The rate of particle clearance, assessed by gamma scintillation camera of the whole lung, showed a three-exponential function, comprising a rapid initial phase in the first 44 h of clearance for tracheobronchial deposition followed by a slower phase of mostly alveolar clearance in the next 30 days and a final phase of very slow relatively pure alveolar clearance. A balance study of particle route during clearance and autopsy of regional thoracic lymph nodes, blood, liver, and spleen demonstrated that this supramicron-sized particle cleared from alveoli predominantly via the mucociliary escalator of the tracheobronchial tree. Whole-lung lavage studies showed particle and macrophage recovery rates suggesting a sequestered state for alveolar-deposited particles, which may partly account for their slow clearance rates. The failure to find interstitial penetration by alveolar-deposited particles indicates that the macrophages engulfing these particles, at low particle burdens, travel normally in only one direction, i.e., from interstitium to alveolus and then to the mucociliary escalator.

Animals↗

Effects of cereal type and feed particle size on morphological characteristics, epithelial cell proliferation, and lectin binding patterns in the large intestine of pigs.

The present study was undertaken to investigate the effects of cereal type and feed particle size on the morphological characteristics and epithelial cell proliferation of the large intestinal tissue in pigs. Forty pigs, weighing approximately 30 kg, were fed diets containing either coarsely or finely milled barley or wheat for a period of 4 wk. Tissue samples were taken from the cecum and from the proximal, medial, and distal colon at slaughter. The pigs fed the coarse diets had significantly larger crypts, in terms of height as well as volume, than did pigs fed the fine diets. The cereal type had no effect on the mucosal architecture. The epithelial cell proliferation, in terms of counted native mitoses in the crypts, was significantly higher in pigs fed the coarse barley diet than in pigs fed the coarse wheat diet or the fine diets. The volume of the mucin granules in the crypts constituted from 32 to 52% of the crypt volume and was greatest in the pigs fed the coarse diets. This effect of feed particle size was observed for neutral as well as for acidic mucins and sulfomucins. Lectin binding patterns indicated that more of the terminal sugars on glycoconjugates of the apical membrane on the mucosal surface were the sialic acid alpha-2,3 neuraminic acid, but less were mannose in the pigs fed the coarse barley diet. Distinct regional differences were observed among the intestinal sites. These included a decline in the epithelial cell proliferation and an increase in the volume of mucin in the crypts along the intestinal tract. Furthermore, the sialic acid alpha-2,3 neuraminic acid was more abundant in the medial colon than in the cecum; the contrary was seen for mannose and galactose. This study shows that the feed particle size of barley and wheat diets, more than the cereal type itself, affects the mucosal architecture, epithelial cell proliferation, and production and composition of the mucins in the large intestine of pigs. The study suggests that pigs fed a coarse diet are better protected against intestinal infections than pigs fed a fine diet.

Animal Feed↗

Pioglitazone plus a sulphonylurea or metformin is associated with increased lipoprotein particle size in patients with type 2 diabetes.

OBJECTIVE: To determine the effect of pioglitazone plus metformin or a sulphonylurea on lipoprotein particle size and subclass distribution in patients with type 2 diabetes. METHODS: Lipid profiles were determined for blood samples from patients participating in two randomised, double-blind, 24-week studies of pioglitazone 30 mg or 45 mg daily plus either metformin or a sulphonylurea. RESULTS: Samples from 177 patients were evaluated; 96 of these patients received a sulphonylurea, and 81 received metformin. Pioglitazone combination treatment produced significant increases from baseline for average and peak low-density lipoprotein (LDL) particle size at weeks 12 and 24 (p<0.0001 for each; range 0.29-0.39 nm for average and 0.36-0.55 nm for peak particle size, respectively). Significant shifts in high-density lipoprotein (HDL) and LDL distribution showed an increase in large particles and a decrease in small particles. For pioglitazone plus metformin, significant increases in levels of apolipoprotein (Apo) Al, Apo Al/All-containing HDL, and lipoprotein(a) also were noted, whereas Apo B levels decreased. CONCLUSIONS: These observed changes are thought to affect the atherogenic profile positively. Therefore, pioglitazone combination treatment may lead to decreased cardiovascular risk in patients with type 2 diabetes.

Cardiovascular Diseases↗

High temporal resolution in situ measurement of the effective particle size characteristics of fluvial suspended sediment.

This paper reports the use of a LISST-100 device to monitor the effective particle size characteristics of suspended sediment in situ, and at a quasi-continuous temporal resolution. The study site was located on the River Exe at Thorverton, Devon, UK. This device has not previously been utilized in studies of fluvial suspended sediment at the storm event scale, and existing studies of suspended sediment dynamics have not involved such a high temporal resolution for extended periods. An evaluation of the field performance of the instrument is presented, with respect to innovative data collection and analysis techniques. It was found that trends in the effective particle size distribution (EPSD) and degree of flocculation of suspended sediment at the study site were highly complex, and showed significant short-term variability that has not previously been documented in the fluvial environment. The collection of detailed records of EPSD facilitated interpretation of the dynamic evolution of the size characteristics of suspended sediment, in relation to its likely source and delivery and flocculation mechanisms. The influence of measurement frequency is considered in terms of its implications for future studies of the particle size of fluvial suspended sediment employing in situ data acquisition.

Environmental Monitoring↗