PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

A microfluidic multi-injector for gradient generation.

This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.

Dimethylpolysiloxanes↗

Magnetism and microfluidics.

Magnetic forces are now being utilised in an amazing variety of microfluidic applications. Magnetohydrodynamic flow has been applied to the pumping of fluids through microchannels. Magnetic materials such as ferrofluids or magnetically doped PDMS have been used as valves. Magnetic microparticles have been employed for mixing of fluid streams. Magnetic particles have also been used as solid supports for bioreactions in microchannels. Trapping and transport of single cells are being investigated and recently, advances have been made towards the detection of magnetic material on-chip. The aim of this review is to introduce and discuss the various developments within the field of magnetism and microfluidics.

Biological Assay↗

Electrochemical microfluidic biosensor for the detection of nucleic acid sequences.

A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple-potassium hexacyanoferrate (ii)/hexacyanoferrate (iii) (ferri/ferrocyanide). A combined concentration of 0.5 microM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay(-1) and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15-20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation.

Biosensing Techniques↗

Fabrication and validation of a multi-channel type microfluidic chip for electrokinetic streaming potential devices.

To elaborate on the applicability of the electrokinetic micro power generation, we designed and fabricated the silicon-glass as well as the PDMS-glass microfluidic chips with the unique features of a multi-channel. Besides miniaturizing the device, the key advantage of our microfluidic chip utilization lies in the reduction in water flow rate. Both a distributor and a collector taking the tapered duct geometry are positioned aiming the uniform distribution of water flow into all individual channels of the chip, in which several hundreds of single microchannels are assembled in parallel. A proper methodology is developed accompanying the deep reactive ion etching as well as the anodic bonding, and optimum process conditions necessary for hard and soft micromachining are presented. It has been shown experimentally and theoretically that the silicon-based microchannel leads to increasing streaming potential and higher external current compared to those of the PDMS-based one. A proper comparison between experimental results and theoretical computations allows justification of the validity of our novel devices. It is useful to recognize that a material inducing a higher magnitude of zeta potential has an advantage for obtaining higher power density under the same external resistance.

Algorithms↗

Immunosensing of Staphylococcus enterotoxin B (SEB) in milk with PDMS microfluidic systems using reinforced supported bilayer membranes (r-SBMs).

A versatile and novel method has been developed for microfluidic immunosensing of the food-borne pathogen Staphylococcus enterotoxin B (SEB) in poly(dimethylsiloxane) (PDMS) chips. Supported bilayer membranes (SBMs) were generated by vesicle fusion in oxidized PDMS microchannels for minimizing non-specific adsorption of biomolecules. The stability of SBMs was strengthened with a streptavidin layer to make them air-stable and allow for subsequent display of the biotin-functionalized antibodies. The reinforced supported bilayer membranes (r-SBMs) are fluid, exhibiting a lateral diffusion coefficient of approximately 1.9 microm(2) s(-1), and no detectable change of mobility was found after dehydration/rehydration. This is a substantial improvement over phosphatidylcholine (PC) membranes on PDMS, which suffered a roughly 10% reduction in the mobile fraction and 30% decrease in mobility after dehydration. Non-specific protein adsorption in the membrane-treated channels was reduced 100-1000 fold as compared to PDMS surfaces without a membrane coating. A flow-based microfluidic immunosensor for SEB was developed using antibodies linked to the r-SBMs in PDMS channels, and a detection limit of 0.5 ng mL(-1) was obtained from the linear portion of the calibration curve. The microchip was applied to detection of SEB in milk, and similar response and sensitivity were obtained, demonstrating the sensor's remarkable performance for real world samples. The r-SBMs overcome the stability hurdle in SBM-modified surfaces, opening up possibilities for transport and storage of membrane-functionalized microchips in the dehydrated form without compromising the performance, and facilitating the commercialization of disposable SBM-based microdevices.

Adsorption↗

Continuous flow separation of particles within an asymmetric microfluidic device.

A microfluidic based device has been developed for the continuous separation of polymer microspheres, taking advantage of the flow characteristics of systems. The chip consists of an asymmetric cavity with variable channel width which enables continuous amplification of the particle separation for different size particles within the laminar flow profile. The process has been examined by varying the sample inlet position, the sample to media flow rate ratio, and the total flow rate. This technique can be applied for manipulating both microscale biological and colloidal particles within microfluidic systems.

Colloids↗

Droplet-based microfluidics with nonaqueous solvents and solutions.

In droplet-based ("digital") microfluidics, liquid droplets in contact with dielectric surfaces are created, moved, merged and mixed by applying AC or DC potentials across electrodes patterned beneath the dielectric. We show for the first time that it is possible to manipulate droplets of organic solvents, ionic liquids, and aqueous surfactant solutions in air by these mechanisms using only modest voltages (<100 V) and frequencies (<10 kHz). The feasibility of moving any liquid can be predicted empirically from its frequency-dependent complex permittivity, epsilon*. The threshold for droplet actuation in air with our two-plate device configuration is /epsilon*/>8x10(-11). The mechanistic implications of these results are discussed, along with the greatly expanded range of applications for digital microfluidics that these results suggest are now feasible.

Algorithms↗

Microfluidics-based systems biology.

Systems biology seeks to develop a complete understanding of cellular mechanisms by studying the functions of intra- and inter-cellular molecular interactions that trigger and coordinate cellular events. However, the complexity of biological systems causes accurate and precise systems biology experimentation to be a difficult task. Most biological experimentation focuses on highly detailed investigation of a single signaling mechanism, which lacks the throughput necessary to reconstruct the entirety of the biological system, while high-throughput testing often lacks the fidelity and detail necessary to fully comprehend the mechanisms of signal propagation. Systems biology experimentation, however, can benefit greatly from the progress in the development of microfluidic devices. Microfluidics provides the opportunity to study cells effectively on both a single- and multi-cellular level with high-resolution and localized application of experimental conditions with biomimetic physiological conditions. Additionally, the ability to massively array devices on a chip opens the door for high-throughput, high fidelity experimentation to aid in accurate and precise unraveling of the intertwined signaling systems that compose the inner workings of the cell.

Animals↗

Characterization of the local temperature in space and time around a developing Drosophila embryo in a microfluidic device.

This paper characterizes a microfluidic platform that differentially controls the temperature of each half of a living Drosophila melanogaster fruitfly embryo in space and time (E. M. Lucchetta, J. H. Lee, L. A. Fu, N. H. Patel and R. F. Ismagilov, Nature, 2005, 434, 1134-1138). This platform relies on laminar flow of two streams of liquid with different temperature, and on rapid prototyping in polydimethylsiloxane (PDMS). Here, we characterized fluid flow and heat transport in this platform both experimentally and by numerical simulation, and estimated the temperature distribution around and within the embryo by numerical simulation, to identify the conditions for creating a sharper temperature difference (temperature step) over the embryo. Embryos were removed from the device and immunostained histochemically for detection of Paired protein. Biochemical processes are sensitive to small differences in environmental temperature. The microfluidic platform characterized here could prove useful in understanding dynamics of biochemical networks as they respond to changes in temperature.

Algorithms↗

A microfluidic device for continuous, real time blood plasma separation.

A microfluidic device for continuous, real time blood plasma separation is introduced. The principle of the blood plasma separation from blood cells is supported by the Zweifach-Fung effect and was experimentally demonstrated using simple microchannels. The blood plasma separation device is composed of a blood inlet, a bifurcating region which leads to a purified plasma outlet, and a concentrated blood cell outlet. It was designed to separate blood plasma from an initial blood sample of up to 45% inlet hematocrit (volume percentage of cells). The microfluidic network was designed using an analogous electrical circuit, as well as analytical and numerical studies. The functionality of this device was demonstrated using defibrinated sheep blood. During 30 minutes of continuous blood infusion through the device, all the erythrocytes (red blood cells) traveled through the device toward the concentrated blood outlet while only the plasma was separated at the bifurcating regions and flowed towards the plasma outlet. The device has been operated continuously without any clogging or hemolysis of cells. The experimentally determined plasma selectivity with respect to blood hematocrit level was almost 100% regardless of the inlet hematocrit. The total plasma separation volume percent varied from 15% to 25% with increasing inlet hematocrit. Due to the device's simple structure and control mechanism, this microdevice is expected to be used for highly efficient continuous, real time cell-free blood plasma separation from blood samples for use in lab on a chip applications.

Fluorescent Dyes↗

Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding.

Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 microl of the whole sample bloods, by means of the fabricated biochip within 3 min.

Blood Grouping and Crossmatching↗

An optically driven pump for microfluidics.

We demonstrate a method for generating flow within a microfluidic channel using an optically driven pump. The pump consists of two counter rotating birefringent vaterite particles trapped within a microfluidic channel and driven using optical tweezers. The transfer of spin angular momentum from a circularly polarised laser beam rotates the particles at up to 10 Hz. We show that the pump is able to displace fluid in microchannels, with flow rates of up to 200 microm(3) s(-1) (200 fL s(-1)). The direction of fluid pumping can be reversed by altering the sense of the rotation of the vaterite beads. We also incorporate a novel optical sensing method, based upon an additional probe particle, trapped within separate optical tweezers, enabling us to map the magnitude and direction of fluid flow within the channel. The techniques described in the paper have potential to be extended to drive an integrated lab-on-chip device, where pumping, flow measurement and optical sensing could all be achieved by structuring a single laser beam.

Microfluidic Analytical Techniques↗

Development and characterization of an all-solid-state potentiometric biosensor array microfluidic device for multiple ion analysis.

A microfluidic device with an all-solid-state potentiometric biosensor array was developed using microfabrication technology. The sensor array included a pH indicator, and potassium and calcium ion-selective microelectrodes. The pH indicator was an iridium oxide thin film modified platinum microelectrode and the iridium oxide was deposited by an electrochemical method. The potassium and calcium ion-selective microelectrodes were platinum coated with silicon rubber based ion-selective membranes with respectively potassium (valinomycin) and calcium (ETH 1001) ionophores. The detection system was integrated with a micro-pneumatic pump which can continuously drive fluids into the microchannel through sensors at flow rates ranging from 52.4 microl min(-1) to 7.67 microl min(-1). The sensor array microfluidic device showed near-Nernstian responses with slopes of 62.62 mV +/- 2.5 mV pH(-1), 53.76 mV +/- 3 mV -log[K+](-1) and 25.77 mV +/- 2 mV -log[Ca2+](-1) at 25 degrees C +/- 5 degrees C, and a linear response within the pH range of 2-10, with potassium and calcium concentrations between 0.1 M and 10(-6) M. In this study the device provided a convenient way to measure the concentration of hydrogen, potassium and calcium ions, which are important physiological parameters.

Biosensing Techniques↗

Production of arrays of chemically distinct nanolitre plugs via repeated splitting in microfluidic devices.

This paper reports a method for the production of arrays of nanolitre plugs with distinct chemical compositions. One of the primary constraints on the use of plug-based microfluidics for large scale biological screening is the difficulty of fabricating arrays of chemically distinct plugs on the nanolitre scale. Here, using microfluidic devices with several T-junctions linked in series, a single input array of large (approximately 320 nL) plugs was split to produce 16 output arrays of smaller (approximately 20 nL) plugs; the composition and configuration of these arrays were identical to that of the input. This paper shows how the passive break-up of plugs in T-junction microchannel geometries can be used to produce a set of smaller-volume output arrays useful for chemical screening from a single large-volume array. A simple theoretical description is presented to describe splitting as a function of the Capillary number, the capillary pressure, the total pressure difference across the channel, and the geometric fluidic resistance. By accounting for these considerations, plug coalescence and plug-plug contamination can be eliminated from the splitting process and the symmetry of splitting can be preserved. Furthermore, single-outlet splitting devices were implemented with both valve- and volume-based methods for coordinating the release of output arrays. Arrays of plugs containing commercial sparse matrix screens were obtained from the presented splitting method and these arrays were used in protein crystallization trials. The techniques presented in this paper may facilitate the implementation of high-throughput chemical and biological screening.

Crystallization↗

Active control of the depletion boundary layers in microfluidic electrochemical reactors.

In this paper, we describe three methods to improve the performance of pressure-driven laminar flow-based microreactors by manipulating reaction-depletion boundary layers to overcome mass transfer limitations at reactive surfaces on the walls, such as electrodes. The transport rate of the reactants to the reactive surfaces is enhanced by (i) removing the depleted zone through multiple periodically-placed outlets; (ii) adding fresh reactants through multiple periodically-placed inlets along the reactive surface; or (iii) producing a spiraling, transverse flow through the integration of herringbone ridges along the channel walls. For approaches (i) and (ii), the network of microfluidic channels needs to be designed such that under the operating conditions used the right amount of boundary layer at each outlet or inlet is removed or replenished, respectively. Here, we report a set of design rules, derived with the help of a fluidic resistance circuit model, to aid in the design of appropriate microfluidic networks. Also, the actual enhancement of the performance of the electrochemical microreactor, i.e. chemical conversion efficiency, using multiple inlets, multiple outlets, or herringbone ridges is reported.

Electrochemistry↗

PDMS absorption of small molecules and consequences in microfluidic applications.

Microfluidic devices made out of polydimethylsiloxane (PDMS) have many physical properties that are useful for cell culture applications, such as transparency and gas permeability. Another distinct characteristic of PDMS is its ability to absorb hydrophobic small molecules. Partitioning of molecules into PDMS can significantly change solution concentrations and could potentially alter experimental outcomes. Herein we discuss PDMS absorption and its potential impact on microfluidic experiments.

Chemical Phenomena↗

A microfluidic system in combination with optical tweezers for analyzing rapid and reversible cytological alterations in single cells upon environmental changes.

We report on the development of an experimental platform where epi-fluorescence microscopy and optical tweezers are combined with a microfluidic system to enable the analysis of rapid cytological responses in single cells. The microfluidic system allows two different media to be merged in a Y-shaped channel. Microscale channel dimensions ensure purely laminar flow and, as a result, an environmental gradient can be created between the two media. Optical tweezers are used to move a single trapped cell repeatedly between the different environments. The cell is monitored continuously by fluorescence microscopy during the experiment. In a first experiment on yeast (Saccharomyces cerevisiae) we observed changes in cell volume as the cell was moved between environments with different osmolarity. This demonstrated that the platform allowed analysis of cytological alterations on a time scale shorter than 0.2 s. In a second experiment we observed the spatial migration of the Yap1p transcription factor fused to GFP as a cell was moved from an environment of low to high oxidative capacity. The system is universal allowing the response to numerous environmental changes to be studied on the sub second time scale in a variety of model cells. We intend to use the platform to study how the age of cells, their progression through the cell cycle, or their genetic landscape, alter their capacity (kinetics and amplitude) to respond to environmental changes.

Culture Media↗

Microfluidic sensor for dynamic surface tension measurement.

A novel microfluidic sensor for measuring dynamic gas-liquid interfacial tension is reported. The device consists of a microfluidic chip with a microchannel network and an optical detection system. The sample is introduced into a main channel, while air is injected through a T-junction. Owing to the fixed flow rate ratio used for the sensor, surface tension is the only parameter determining bubble formation frequency, which can be measured by optical detection. Although the bubble is represented by a pulse in the output signal, the formation frequency is simply the frequency of the output signal. Measurements were carried out for aqueous solutions with different concentrations of the ionic surfactant cetyl trimethyl ammonium bromide. Surface tensions of these solutions were calibrated with a commercial tensiometer. The measurement results show a clear relationship between surface tension and formation frequency. The sensor can be used to identify the critical micelle concentration of the surfactant. The sensor potentially allows the use of a minute amount of sample compared with the relatively large amount required for existing commercial systems.

Equipment Design↗