PubMed Health⌕ Search

PubMed · 16738728

A microfluidic multi-injector for gradient generation.

Abstract

This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bong Geun Chung, Francis Lin, Noo Li Jeon. 2006-04-06. A microfluidic multi-injector for gradient generation.. https://doi.org/10.1039/b512667c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.

A PDMS-based microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The detection is based on the optical adsorption of the colour solution formed by in-channel mixing of sample and reagent solutions. Computational Fluid Dynamics (CFD) simulation and kinetic study of the colour development were conducted to determine the minimum channel length and optimum residential time for homogenous mixing and maximum optical adsorption respectively. The system was proved to be able to detect lactate with good linearity (R(2)=0.98), response time of about 130 s and estimated limitation of detection (LOD) of 0.52 mM (about 47 mg/L), which is sufficient for a general online lactate detection. Due to the miniaturization of sensing system and micro-scale mixing, higher detection sensitivity (0.15 V/mM) can be realized than the mixing in lab-scale equipments (0.08 V/mM).

Dimethylpolysiloxanes↗

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗