PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Protein Array Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27Linked to original sources

Protein patterning by maskless photolithography on hydrophilic polymer-grafted surface.

With the help of a microfabrication process and surface modification technology, a method of fabricating protein patterned chips was developed which can be utilized as a powerful tool for performing bioassays in a high-throughput manner. A digital micromirror array (MMA) system was used as a virtual photomask, so that a maskless photolithography process was able to be used to build patterned biomolecules on a chip by selective illumination onto the chip surface. We utilized the nitroveratryloxycarbonyl (NVOC) group as a photolabile protecting group for protein patterning. The NVOC-protected surface was selectively irradiated by a UV illuminator using an MMA. After removing the NVOC group, biotin was coupled to the NVOC-cleaved site, onto which a buffered streptavidin solution was eluted. At this point, we could obtain a streptavidin-patterned surface and observe the effect of the polymer-grafted surface in reducing nonspecific binding.

Adsorption↗

Dimensionality is the issue: use of photoaptamers in protein microarrays.

The development of high-density arrays for proteomics has become a goal of SomaLogic, many other companies, and a wide variety of academic entities. Unfortunately, the word proteomics has come to mean virtually everything. We define proteomics as being derived from arrays of analyte-specific reagents (ASRs) used to measure (something about) proteins. As the density of the ASRs on a chip increases toward the number of proteins in an organism, the concept of proteomics moves toward comprehensive proteomics. At issue then, is what constitutes an ASR, and what differences between them lead toward more or less biological information from a high-density panel of ASRs.

Electrophoresis, Gel, Two-Dimensional↗

Peptide arrays: from macro to micro.

Over the past decade of proteome research peptide arrays have become a widespread and powerful tool to study molecular recognition events and to identify biologically active peptides. A variety of applications such as epitope mapping, characterisation of protein-protein interactions, enzyme-substrate or inhibitor interactions, and many more, have been published. Today's technologies for array production, inspired by DNA chips, have recently turned to the miniaturisation of peptide arrays. These advances open up an expanding spectrum of applications and the information obtained will be well-suited to developing substrates and inhibitors for diagnostic and therapeutic purposes.

Anti-Bacterial Agents↗

Developing site-specific immobilization strategies of peptides in a microarray.

In peptide-based microarrays, most existing methods do not allow for site-specific immobilization of peptides on the glass surface. We have developed two new approaches for site-specific immobilization of kinase substrates onto glass slides: (1) slides were functionalized with avidin for attachment of biotinylated peptides; and (2) slides were functionalized with thioester for attachment of N-terminally cysteine-containing peptides via a native chemical ligation reaction.

Amino Acid Sequence↗

Directed evolution of high-affinity antibody mimics using mRNA display.

We constructed a library of >10(12) unique, covalently coupled mRNA-protein molecules by randomizing three exposed loops of an immunoglobulin-like protein, the tenth fibronectin type III domain (10Fn3). The antibody mimics that bound TNF-alpha were isolated from the library using mRNA display. Ten rounds of selection produced 10Fn3 variants that bound TNF-alpha with dissociation constants (K(d)) between 1 and 24 nM. After affinity maturation, the lowest K(d) measured was 20 pM. Selected antibody mimics were shown to capture TNF-alpha when immobilized in a protein microarray. 10Fn3-based scaffold libraries and mRNA-display allow the isolation of high-affinity, specific antigen binding proteins; potential applications of such binding proteins include diagnostic protein microarrays and protein therapeutics.

Amino Acid Sequence↗

Immobilized peptides as high-affinity capture agents for self-associating proteins.

There is currently great interest in the fabrication of protein-detecting arrays comprised of large numbers of immobilized protein capture agents. While most efforts in this arena have focused on the use of biomolecules such as antibodies and nucleic acid aptamers as capture agents, synthetic species have many potential advantages. However, synthetic molecules isolated from combinatorial libraries generally do not bind target proteins with the high affinity necessary for array applications. Here, we demonstrate that simple linear peptides bind dimeric proteins tenaciously when immobilized, although they exhibit only modest affinity in solution. These data show that high-affinity bidentate capture agents for dimeric proteins can be created by simply immobilizing modest-affinity ligands on a surface at high density, bypassing the requirement for careful optimization of linker length and geometry that is normally required to create a high-affinity solution bidentate ligand.

Combinatorial Chemistry Techniques↗

Progress in protein and antibody microarray technology.

The success of genome sequencing projects has led to a shift from the description of single molecules to the characterisation of complex samples. At the same time, there is growing interest not only in studying organisms at the genomic level, but in the characterization of their proteome. Such a task would not be possible without the availability of appropriate technologies. Protein and antibody microarray technologies are, in addition to two-dimensional gel electrophoresis followed by mass spectrometry, two of the most propitious technologies for the screening of complex protein samples. Nevertheless, to succeed, protein and antibody microarrays have to overcome their current limitations. This review aims to introduce these new technologies and highlights their current prospects and limitations.

Antibodies↗

Finding the target after screening the phenotype.

Although most screening for new drug leads is being directed at known or emerging molecular targets, there has been a renaissance in screening based on changes in cell or organismal phenotypes. Phenotype-based screening is accompanied by the challenge of identifying the molecular target or targets bound by the drug leads and responsible for their pharmacological activity. A variety of technologies and approaches are being explored for target identification after phenotypic screening. Direct approaches employing affinity chromatography, expression cloning and protein microarrays analyze the compound bound to its target. Indirect approaches are based on comparison of the genome-wide activity profile of the compound with databases of the activity profiles of other compounds with known targets or activity profiles following specific genetic changes. This review will use case studies of target identification efforts and highlight the advantages and disadvantages of the various approaches to target identification after phenotypic screening.

Animals↗

Protein chip technology.

Microarray technology has become a crucial tool for large-scale and high-throughput biology. It allows fast, easy and parallel detection of thousands of addressable elements in a single experiment. In the past few years, protein microarray technology has shown its great potential in basic research, diagnostics and drug discovery. It has been applied to analyse antibody-antigen, protein-protein, protein-nucleic-acid, protein-lipid and protein-small-molecule interactions, as well as enzyme-substrate interactions. Recent progress in the field of protein chips includes surface chemistry, capture molecule attachment, protein labeling and detection methods, high-throughput protein/antibody production, and applications to analyse entire proteomes.

Protein Array Analysis↗

Affinity-capture reagents for protein arrays.

The simultaneous identification and quantitative measurement of the production levels of thousands of different proteins in a biological specimen remains an unachieved goal of modern proteomic research. Advances in the development of microarray-based platforms for highly parallel detection of proteins have therefore received a considerable impulse during the last few years. Here, we review the existing reagents for affinity capture of protein targets, as well as the techniques used for their immobilization on solid supports and methods for the detection of binding events, underlining the problems and the opportunities in this continuously evolving research field.

Biotechnology↗

A microarray immunoassay for simultaneous detection of proteins and bacteria.

We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

Animals↗

Macro-/nanoporous silicon as a support for high-performance protein microarrays.

The present work demonstrates the possibilities of using macroporous silicon as a substrate for highly sensitive protein chip applications. The formation of 3D porous silicon structures was performed by electrochemical dissolution of monocrystalline silicon. The fabricated macroporous silicon network has a rigid spongelike structure showing high uniformity and mechanical stability. The microfluidic properties of the substrates were found to be essential for a good bioassay performance. Small spot area, good spot reproducibility, and homogeneous spot profiles were demonstrated on the substrates for immobilized aRIgG. Water contact angles were measured on the porous surface and compared to that of planar silicon, silanized glass, and ordinary microscope glass slides. The effect of the porous surface on the performance of a model IgG-binding immunoassay is presented. aRIgG was microdispensed onto the chip surface forming a microarray of spots with high affinity for the target analyte. The dispensing was performed using an in-house-developed piezoelectric flow-through dispenser. Each spot was formed by a single droplet (100 pL) at each position. The macroporous silicon allowed a high-density microarraying with spot densities up to 4400 spots/cm2 in human plasma samples without cross-talk and consumption of only 0.6 pmol of antibodies/1-cm2 array. Antigen levels down to 70 pM were detected.

Antibodies↗

A filtration-based protein microarray technique.

Protein microarrays are an emerging technology for studying protein expression profiling and protein functions. However, with the current design approaches, the overall performance of protein microarrays can be compromised by diffusion-limited kinetics. We developed a new protein microarray platform that utilizes a filtration assay with protein microarrays printed on protein-permeable nitrocellulose filter membranes. Compared with protein microarrays assayed with the conventional incubation-shaking method, this new approach overcomes the diffusion limit. We demonstrated that this novel technique can improve the overall reaction kinetic rate by 10-fold, yield a dynamic range of 4 decades, and enhance the assay sensitivity and specificity. Further, using multistacking protein chips, at least 14 chips can be probed simultaneously, with 22400 different reactions in a single assay. The advantages of large fluorescent dyes, such as phycobilisome and quantum dots, can be better exploited using the filtration assay. The potential clinical applications of the filtration-based protein microarrays were demonstrated by detecting carcinoembryonic antigen in human plasma samples.

Antibodies↗

A label-free multisensing immunosensor based on imaging ellipsometry.

An immunosensor based on imaging ellipsometry and its potential applications was demonstrated in this paper. It has been proven a fast, reliable, and convenient method to quantify the thickness distribution of protein layers or detect protein concentration in solution. Combined with a protein chip, the immunosensor was able to detect multiple analytes simultaneously without any labeling. Preliminary results demonstrated how this immunosensor could be used to monitor several independent biospecific binding processes in real-time and in situ conditions.

Animals↗

Cell-free protein expression and functional assay in nanowell chip format.

The expression and characterization of large protein libraries requires high-throughput tools for rapid and cost-effective expression and screening. A promising tool to meet these requirements is miniaturized high-density plates in chip format, consisting of an array of wells with submicroliter volumes. Here, we show the combination of nanowell chip technology and cell-free transcription and translation of proteins. Using piezoelectric dispensers, we transferred proteins into nanowells down to volumes of 100 nL and successfully detected fluorescence using confocal laser scanning. Moreover, we showed cell-free expression of proteins on a nanoliter scale using commercially available coupled transcription and translation systems. To reduce costs, we demonstrated the feasibility of diluting the coupled in vitro transcription and translation mix prior to expression. Additionally, we present an enzymatic inhibition assay in nanowells to anticipate further applications, such as the high-throughput screening of drug candidates or the identification of novel enzymes for biotechnology.

Cell-Free System↗

Protein microarray system for detecting protein-protein interactions using an anti-His-tag antibody and fluorescence scanning: effects of the heme redox state on protein-protein interactions of heme-regulated phosphodiesterase from Escherichia coli.

A highly sensitive microarray system for detecting protein-protein interactions has been developed. This method was successfully applied to analyze the interactions of heme-regulated phosphodiesterase from Escherichia coli (Ec DOS). To immobilize (His)6-Tag fused Ec DOS, anti-(His)6-Tag monoclonal antibody (anti-(His)6-Tag mAb) was initially immobilized on the solid surface, and (His)6-Tag fused Ec DOS was fixed by antigen-antibody interactions. For this experiment, ProteoChip, generally suitable for antibody immobilization, was used as solid substrate. In this report, we confirm the antibody immobilization ability of ProteoChip and specific binding to the F(c) region of the antibody. Based on this finding, interdomain interactions between Ec DOS and the isolated heme-bound PAS domain were investigated on the solid surface. Ec DOS immobilized via anti-(His)6-Tag mAb maintained interactions with the PAS fragment, in contrast to directly immobilized Ec DOS in the absence of anti-(His)6-Tag mAb. Heme-redox-sensitive interactions between Ec DOS and the PAS fragment were additionally detected using anti-(His)6-Tag mAb as a mediator. Our results collectively suggest that the immobilization method using anti-Tag antibody is suitable for maintaining native protein characteristics to facilitate elucidation of their structures and functions on solid surfaces.

Antibodies↗

Real-time surface plasmon resonance imaging measurements for the multiplexed determination of protein adsorption/desorption kinetics and surface enzymatic reactions on peptide microarrays.

The kinetics of protein adsorption/desorption onto peptide microarrays was studied using real-time surface plasmon resonance (SPR) imaging. S protein binding interactions were examined using an array composed of five different peptides: N terminal and C terminal immobilized wild-type S peptide (S1 and S2), an alternate binding sequence derived by phage display (LB2), an NVOC-protected S peptide, and a FLAG peptide control sequence (F). Kinetic measurements of the S protein-S1 peptide interaction were analyzed to determine a desorption rate constant (k(d)) of 1.1 (+/-0.08) x 10(-2) s(-1), an adsorption rate constant (k(a)) of 1.9 (+/-0.05) x 10(5) M(-1) s(-1), and an equilibrium adsorption constant (K(Ads)) of 1.7 (+/-0.08) x 10(7) M(-1). SPR imaging equilibrium measurements of S protein to S1 peptide were performed to independently confirm the kinetically determined value of K(Ads). Rate constants for the S2 and LB2 peptides on the array were measured as follows: 1.6 (+/-0.04) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.07) x 10(-2) s(-1) (k(d)) for S2, 1.2 (+/-0.05) x 10(5) M(-1) s(-1) (k(a)) and 1.1 (+/-0.03) x 10(-2) s(-1) (k(d)) for LB2. In addition to S protein adsorption/desorption, real-time SPR imaging of peptide arrays was applied to study the surface enzymatic activities of the protease factor Xa. Enzymatic cleavage of the substrate peptide (P1) was shown to follow first-order kinetics and proceed at a rate 10 times faster than that of the mutant peptide (P2), with cleavage velocities of 5.6 (+/-0.3) x 10(-4) s(-1) for P1 and 5.7 (+/-0.3) x 10(-5) s(-1) for P2.

Adsorption↗

Aptamer-based sensor arrays for the detection and quantitation of proteins.

Aptamer biosensors have been immobilized on beads, introduced into micromachined chips on the electronic tongue sensor array, and used for the detection and quantitation of proteins. Aptamer chips could detect proteins in both capture and sandwich assay formats. Unlike most protein-based arrays, the aptamer chips could be stripped and reused multiple times. The aptamer chips proved to be useful for screening aptamers from in vitro selection experiments and for sensitively quantitating the biothreat agent ricin.

Base Sequence↗