PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microchip Analytical Procedures”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Uniformity of ionization response of structurally diverse analytes using a chip-based nanoelectrospray ionization source.

The major drawback of liquid chromatography/mass spectrometry (LC/MS) for the analysis of mixtures is the non-quantitative nature of these studies. The ionization efficiency of the various components in the mixture (e.g., a compound and its metabolites) can vary greatly and, therefore, relative intensities of signals cannot be related to relative abundance. A chip-based nanoelectrospray ionization source was used to compare the ionization efficiencies of compounds with different physical-chemical characteristics. The data indicate that the ionization efficiencies vary much less with the chip-based device than by LC/MS. This was ascribed to the generation of a much higher electric field around the nozzles, which supplies a large excess of protons to the small droplets and reduces/eliminates the differences in the ionization efficiency for the analytes.

Animals↗

Methods for fabricating microarrays of motile bacteria.

Motile bacterial cell microarrays were fabricated by attaching Escherichia coli K-12 cells onto predesigned 16-mercaptohexadecanoic acid patterned microarrays, which were covalently functionalized with E. coli antibodies or poly-L-lysine. By utilizing 11-mercaptoundecyl-penta(ethylene glycol) or 11-mercapto-1-undecanol as passivating molecules, nonspecific binding of E. coli was significantly reduced. Microcontact printing and dip-pen nanolithography were used to prepare microarrays for bacterial adhesion, which was studied by optical fluorescence and atomic force microscopy. These data indicate that single motile E. coli can be attached to predesigned line or dot features and binding can occur via the cell body or the flagella of bacteria. Adherent bacteria are viable (remain alive and motile after adhesion to patterned surface features) for more than four hours. Individual motile bacterial cells can be placed onto predesigned surface features that are at least 1.3 microm in diameter or larger. The importance of controlling the adhesion of single bacterial cell to a surface is discussed with regard to biomotor design.

Bacteria↗

Acoustic microsensors--the challenge behind microgravimetry.

Acoustic microsensors are commonly known as high-resolution mass-sensitive devices. This is a restricted view in many chemical and biosensor applications, especially in liquids. Sensitivity to non-gravimetric effects is a challenging feature of acoustic sensors. In this review we give an overview of recent developments in resonant sensors including micromachined devices and also list recent activity relating to the (bio)chemical interface of acoustic sensors. Major results from theoretical analysis of quartz crystal resonators, descriptive for all acoustic microsensors are summarized, and non-gravimetric contributions to the sensor signal from viscoelasticity and interfacial effects are discussed. We finally conclude with some future perspectives.

Lab-On-A-Chip Devices↗

Laser-induced fluorescence microscopic system using an optical parametric oscillator for tunable detection in microchip analysis.

A laser-induced fluorescence microscopic system based on optical parametric oscillation has been constructed as a tunable detector for microchip analysis. The detection limit of sulforhodamine B (Ex. 520 nm, Em. 570 nm) was 0.2 mumol, which was approximately eight orders of magnitude better than with a conventional fluorophotometer. The system was applied to the determination of fluorescence-labeled DNA (Ex. 494 nm, Em. 519 nm) in a microchannel and the detection limit reached a single molecule. These results showed the feasibility of this system as a highly sensitive and tunable fluorescence detector for microchip analysis.

Bacteriophage lambda↗

A microchip sensor for calcium determination.

A newly designed glass-PDMS microchip-based sensor for use in the determination of Ca(2+) ions has been developed, utilizing reflectance measurements from arsenazo III (1,8-dihydroxynaphthalene-3,6-disulfonic acid-2,7-bis[(azo-2)-phenyl arsenic acid]) immobilized on the surface of polymer beads. The beads, produced from cross-linked poly(p-chloromethylstyrene) (PCMS), were covalently modified with polyethylenimine (PEI) to which the Arsenazo III could be adsorbed. The maximum amount of Arsenazo III which could be immobilized onto the PEI-attached PCMS beads was found to be 373.71 mg g(-1) polymer at pH 1. Once fabricated, the beads were utilized at the detection point of the microfluidic sensor device with a fiber optic assembly for reflectance measurements. Samples were mobilized past the detection point in the sensor where they interact with the immobilized dye. The sensor could be regenerated and re-used by rinsing with HCl solution. The pH, voltage, linear range, and the effect of interfering ions were evaluated for Ca(2+) determination using this microchip sensor. At the optimum potential, 0.8 kV, and pH 9.0, the linear range of the microchip sensor was 3.57 x 10(-5) - 5.71 x 10(-4) M Ca(2+), with a limit of detection (LOD) of 2.68 x 10(-5) M. The microchip biosensor was then applied for clinical analysis of calcium ions in serum with good results.

Arsenazo III↗

Microfabrication of screen-printed nanoliter vials with embedded surface-modified electrodes.

A self-contained ion-selective sensing system within a nanoliter-volume vial has been developed by integrating screen printing, laser ablation, and molecular imprinting techniques. Screen printing and laser ablation are used in tandem to fabricate nanoliter-volume vials with carbon and Ag/AgCl ring electrodes embedded in the sidewalls. Using multisweep cyclic voltammetry, the surface of the carbon electrode can be modified with a polypyrrole film. By polymerizing pyrrole in the presence of nitrate, pores complementary to the nitrate anion in size, shape, and charge distribution are formed in the resulting film. Electrochemical cells modified with this nitrate-imprinted polypyrrole film show a near-Nernstian response to nitrate, and excellent reproducibility. The integration of molecular recognition and electrochemical response in the nanoliter vials is demonstrated by the detection of as little as 0.36 ng nitrate in nanoliter-volume samples. The integration of tailored molecular recognition within nanoliter vials via established fabrication and imprinting protocols should result in a number of nanosensor devices with applications in BioMEMS and micro total analysis systems.

Electrochemistry↗

Smart HIV testing system.

The quick HIV testing method called "MiraWell Rapid HIV Test" uses a specialized testing kit to determine whether an individual's blood is contaminated with the HIV virus or not. When a drop of blood is placed on the center of the testing kit, a simple pattern will appear in the middle of the kit to indicate the test status, i.e., positive or negative. This HIV test should be done in a small clinic or in a lab and the test must be conducted by a trained technician. A smart HIV testing system was developed through this research to eliminate the human error that is associated with the use of the quick HIV testing kits. Also, the smart HIV system will improve the testing productivity in comparison to those achieved by the trained technicians. In this research, we have developed a cost-effective system that analyzes the image produced by the HIV kits. We have used a System-On-Chip (SOC) design approach based on the Field Programmable Gate Array (FPGA) technology and the Xilinx Virtex SOC chip in building the system's prototype. The system used a CMOS digital camera to capture the image and an FPGA chip to process the captured image and send the testing results to the display unit. The system can be used in small clinics and pharmacies and eliminates the need for trained technicians. The system has been tested successfully and 98% of the tests were correct.

HIV↗

Real-time monitoring of antibody secretion from hybridomas on a microchip by time-resolved luminescence anisotropy analysis.

This article presents a real-time monitoring system for cellular analysis using micro total analysis systems technology. Time-resolved luminescence anisotropy analysis was adopted for real-time detection of small amounts of a target protein produced by a small number of cells. The system was tested by real-time monitoring of the antibody secretion by hybridomas. The cells were successfully cultivated in a micro-incubation chamber (240 nl) fabricated on a microchip. The quantification of the antibody was achieved using the Ru(II) complex-labeled Staphylococcus aureus protein A probe, which can bind specifically to the Fc region of the antibody. Using this system, we detected as little as 24 fmol of immunoglobulin G under physiological conditions without the bound/free separation protocol. We successfully achieved real-time and quantitative monitoring of small amounts of antibody production by approximately 200 hybridoma cells. This method could be applied to various cellular analyses using small numbers of cells.

Animals↗

A novel cis-acting element in Her2 promoter regulated by Stat3 in mammary cancer cells.

Stat3 plays important roles in the development of breast malignancies and oncogenesis. In the present study, a palindromic cis-acting element displaying repression activity in breast cancer cells expressing low level of Her2 was found in Her2 promoter. Deletion analysis showed that the novel element was located within Pal2 region spanning nucleotides -529 to -505. The sequence analysis of Pal2 region revealed a DNA sequence (TTAAGATAA) homologous to the binding site of Stat3, starting from position -529 to -521bp. By reporter assay, Pal2 was found to be regulated by constitutive activated Stat3C. A stimulatory effect both on Her2 mRNA and protein expressions was observed in MCF-7 cells stably expressing Stat3C, suggesting that Stat3 regulated Her2 expression. Using ChIP assays the binding of Stat3 to Her2 promoter was confirmed. The data obtained in this study indicate constitutive activated Stat3 regulates Her2 expression. Further investigation of differential effects of Stat3 exerting on breast cancer cells expressing Her2 at different levels will provide more insights into the roles of Stat3 in Her2 expression as well as the regulation of diverse biological activities.

Base Sequence↗

Quantitative evaluation of cell-to-cell communication effects in cell group class using on-chip individual-cell-based cultivation system.

Cell-to-cell communication is considered to underlie the coordinated behavior and the multicellularity of cell group class, which cannot be explained only by the knowledge of lower class of life system from molecule to individual cell, because they are determined by at least two different ways: diffusible chemical signals and their direct physical contacts. We show in this paper a new method of individual-cell-based cell observation that can estimate the role of cell-to-cell communication, diffusible chemical signals, and physical contacts as separated properties, by applying an on-chip individual-cell-based cultivation system. The exchange of stationary phase medium on isolated individual Escherichia coli from exponential phase medium and the control of physical contacts indicated that the cell-to-cell direct contact did not affect the growth rate; only the communication through diffusible signals affects the growth rates as Hill's equation manner.

Cell Communication↗

Fabrication of high quality microarrays.

Fabrication of DNA microarray demands that between ten (diagnostic microarrays) and many hundred thousands of probes (research or screening microarrays) are efficiently immobilised to a glass or plastic surface using a suitable chemistry. DNA microarray performance is measured by parameters like array geometry, spot density, spot characteristics (morphology, probe density and hybridised density), background, specificity and sensitivity. At least 13 factors affect these parameters and factors affecting fabrication of microarrays are used in this review to compare different fabrication methods (spotted microarrays and in situ synthesis of microarrays) and immobilisation chemistries.

Cross-Linking Reagents↗

Photo-reactive polyvinylalcohol for photo-immobilized microarray.

A new photo-reactive polymer, polyvinylalcohol modified with phenylazido groups, was synthesized as a microarray matrix. The polymer is soluble in water and spin-coated onto glass plate. Aqueous solutions of proteins were micro-spotted onto the coated glass and were fixed by ultraviolet light irradiation. Subsequently, cell adhesion on the photo-immobilized protein microarray was investigated. Non-specific adhesion of cells onto non-protein-spotted regions was reduced in comparison with the previously prepared microarray chip (Biomaterials 24 (2003) 3021). The adhesion behavior of cells depended on the kind of immobilized proteins and the type of cells. The microarray will be useful for cell diagnosis and for the selection of biomaterials to regulate cell behavior.

Animals↗

A multicellular spheroid array to realize spheroid formation, culture, and viability assay on a chip.

We describe a novel multicellular spheroid culture system that facilitates the easy preparation and culture of a spheroid microarray for the long-term monitoring of cellular activity. A spheroid culture device with an array of pyramid-like microholes was constructed in a silicon chip that was equipped with elastomeric microchannels. A cell suspension was introduced via the microfluidic channel into the microstructure that comprised silicon microholes and elastomeric microwells. A single spheroid can be formed and localized precisely within each microstructure. Since the culture medium could be replaced via the microchannels, a long-term culture (of approximately 2 weeks) is available on the chip. Measurement of albumin production in the hepatoma cell line (HepG2) showed that the liver-specific functions were maintained for 2 weeks. Based on the cellular respiratory activity, the cellular viability of the spheroid array on the chip was evaluated using scanning electrochemical microscopy. Responses to four different chemical stimulations were simultaneously detected on the same chip, thus demonstrating that each channel could be evaluated independently under various stimulation conditions. Our spheroid culture system facilitated the understanding of spheroid formation, culture, and viability assay on a single chip, thus functioning as a useful drug-screening device for cancer and liver cells.

Albumins↗