PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROCARDIOGRAPHY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

[Value of continous 12-hour electrocardiography during the rehabilitation period in patients convalescing from myocardial infarction. Apropos of 40 cases].

The results of continuous 12-hour electrocardiography in 40 convalescent patients after myocardial infarction undergoing a programme of readaptation on average 4 weeks after the initial infarction are reported. The frequency and alarming nature of the VES observed in 75% patients who had already undergone selection for the coronary readaptation programme, 30% of whom were receiving antiarrhythmic therapy, is emphasized. The observation of a progressive increase in the number of VES during the day prompts the following suggestions: the possibility of limited continuous ECG monitoring at the end of the day, the need to adapt the dosage of antiarrhythmic drugs during this most critical period. The comparison of the results of continuous ECG with those of repeated exercise ECG seems very positive, but some reservations are made and it would seem logical to associate these two complementary methods of investigation.

Adult↗

Signal averaged electrocardiography (SAECG) in patients on hemodialysis.

Cardiovascular diseases are the major cause of mortality in patients on hemodialysis (HD). Recently, signal averaged electrocardiography (SAECG) has been developed to detect ventricular late potentials (LP) noninvasively from the body surface for identifying patients at sudden death or ventricular tachycardia. We performed SAECG in 42 patients before and after HD. As a result, postdialysis total filtered QRS duration (FQRS) was significantly increased compared with predialysis FQRS. Postdialysis duration of low amplitude signal under 40 microV in the latter part of QRS (LAS40) tended to increase compared with predialysis LAS40. Before HD, there were no patients with LP and only one patient (2.4%) with abnormal SAECGs. In contrast, after HD, there were three patients (7.1%) with LP and three more patients (7.1%) with abnormal SAECGs. Furthermore, there was a significant correlation between the changes in LAS40 (delta LAS40) and those in potassium (K) (delta K) during HD. We further examined the relation between LAS40 and the concentration of K, by comparing the correlation coefficient between patients in the high-K group (predialysis K > or = 5.0 mEq/L; 20 patients) and those in the low-K group (predialysis K < 5.0 mEq/L; 22 patients). In the low-K group, there was no significant correlation between delta LAS40 and delta K. However, in the high-K group, there was a significant correlation between delta LAS40 and delta K. In conclusion, SAECG indices worsened during HD, and an insufficient decrement of serum potassium by HD is suggested to have been an arrhythmogenic factor in the high-K group.

Adult↗

[Changes in variability of heart rate and sudden death detected during ambulatory electrocardiography].

Two patients with ischemic heart disease had sudden death detected by means of ambulatory electrocardiography; the first patient had ventricular tachycardia-asystole and the second bradycardia-asystole without mediating a ventricular tachyarrhythmia. In both cases the autonomic function of the heart was determined, by means of the heart rate variability for spectral analysis and for time domain analysis. An important decrease in heart rate variability in the patient with tachyarrhythmia was appreciated, more pronounced in the hour previous to his death. On the other hand, in the patient with bradycardia-asystole there was increased heart rate variability. This suggests different neural influences in both patients for the development of sudden death: an alteration in the autonomic function of the heart in the patient with ventricular tachyarrhythmias, related to a depressed parasympathetic tone. In the patient with bradycardia-asystole, the parasympathetic tone was accentuated.

Adult↗

Fetal paroxysaml supraventricular tachycardia recorded by intrauterine scalp electrocardiography.

Fetal and neonatal paroxysmal supraventricular tachycardia (PST) requires attention because it may be associated with cardiac pathology and neonatal demise. Continuous monitoring of fetal heart rate and the ability to record clearly interpretable electrocardiograms from fetal scalp electrodes makes discovery and diagnoses of these fetal arrhythmias relatively simple. This report describes the discovery of this arrhythmia during routine DOPPLER ultrasound fetal monitoring and its documentation as PST by fetal scalp electrocardiography. (Fig. 1) The fetal heart rate during PST was 300 BPM, higher than previously reported. In contrast to previous reports, it did not appear post-natally and no pathology was found. Although the significance of transient fetal PST is not known, prudence indicates close observation of the neonate. This case demonstrates the value of fetal monitoring for the discovery, diagnosis and documentation of fetal arrhythmias during labor.

Delivery, Obstetric↗

Higher order regularization techniques for inverse electrocardiography.

We have previously presented the generalized eigensystem (GES) approach as an alternative to truncated singular value decomposition and zero order Tikhonov regularization methods for the ill-conditioned inverse problem of electrocardiography. In this paper we extend our comparison of GES with Tikhonov regularization utilizing higher order regularizers applied to a realistic heart/torso geometry with measured epicardial and body surface potentials. Utilizing higher order regularizers the results from Tikhonov regularization more closely match those of the GES techniques.

Animals↗

Signal-averaged electrocardiography.

Signal-averaged electrocardiography (SAECG) is a technique involving computerized analysis of segments of a standard surface electrocardiogram. It is used for detecting small electrical impulses, termed ventricular late potentials, that follow the QRS segment. They are embedded in the electrocardiogram but ordinarily obscured by skeletal muscle activity and other extraneous sources of "noise" encountered in recording a standard electrocardiogram. Ventricular late potentials in patients with cardiac abnormalities, especially coronary artery disease or following an acute myocardial infarction, are associated with an increased risk of ventricular tachyarrhythmias and sudden cardiac death. Proponents of SAECG claim that it can obviate the need for invasive techniques commonly used to identify high-risk patients for interventions that treat or prevent ventricular tachyarrhythmia and sudden death. No randomized clinical trials evaluating SAECG have been completed; data from an ongoing National Institutes of Health-sponsored clinical trial are expected to be available in 3-4 years. The current data on SAECG show relatively consistent high negative predictive values, poor positive predictive values, and variable sensitivity and specificity when the technique is used on patients with cardiomyopathy or following a myocardial infarction. The available evidence also indicates that combining SAECG with other tests of cardiac function is superior to using any single test for risk. The utility of SAECG alone as an indicator of risk remains to be proven. SAECG combined with other standard tests of risk has been demonstrated to have clinical utility in patients following an acute myocardial infarction. Other patient populations have not been conclusively shown to benefit from its use.

Arrhythmias, Cardiac↗

The effect of ethnicity on survival in male veterans referred for electrocardiography and treadmill testing.

BACKGROUND: Ethnic differences in the relationship between access to health care and survival are difficult to define because of many confounding factors, such as socioeconomic status and baseline differences in health. Because the Veterans Affairs health care system offers health care largely without financial considerations, it provides an ideal setting in which to identify and understand ethnic differences in health outcomes. Previous studies in this area have lacked clinical and cardiovascular data with which to adjust for baseline differences in patients' health. METHODS: Data were collected from consecutive men referred for resting electrocardiography (ECG) (n = 41 087) or exercise testing (n = 6213) during 12 years. We compared ethnic differences in survival between whites, blacks, and Hispanics after considering baseline differences in age and hospitalization status. We also adjusted for electrocardiogram abnormalities and cardiac risk factors, exercise test results, and cardiovascular comorbidities. RESULTS: White patients tended to be older and had more baseline comorbidities and cardiovascular interventions when they presented for testing. White patients had increased mortality rates compared with blacks and Hispanics. In the ECG population, after adjusting for demographics and baseline electrocardiogram abnormalities, Hispanics had improved survival compared with whites and blacks. In the exercise test population, after adjusting for the same factors, as well as adjusting for the presence of cardiovascular comorbidities, cardiac risk factors, and exercise test findings, Hispanics also exhibited improved survival compared with the other 2 ethnicities. There were no differences in mortality rates between whites and blacks. CONCLUSION: Our findings demonstrate that the health care provided to veterans referred for routine ECG or exercise testing is not associated with poorer survival in ethnic minorities.

Aged↗

Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function.

BACKGROUND: Electrocardiography-gated single photon emission computed tomography (SPECT) radionuclide angiography (RNA) provides accurate measurement of both left ventricular (LV) ejection fraction (EF) and end-diastolic and end-systolic volumes. In this study we studied the interstudy precision and reliability of SPECT RNA as compared with planar RNA for the measurement of global systolic LV function. METHODS AND RESULTS: The population included 10 patients with chronic coronary artery disease having 2 sets of acquisitions, each consisting of planar and SPECT RNA. SPECT RNA was processed with SPECT-QBS and SPECT-35%. (For SPECT-35%, a manual segmentation method based on the 35% threshold of the maximum LV cavity activity is used to provide estimates of the number of voxels and the activity included in the LV cavity. The calculated LV number of voxels is then used to calculate LV volume measurement. The LV EF is calculated as the ratio of LV end-diastolic and end-systolic activity.) For LV EF, end-diastolic volume, and end-systolic volume, the interstudy precision, as reflected by the correlation coefficient, coefficient of variability, coefficient of repeatability, and within-subject coefficient of variation, and the interstudy reliability, as reflected by the intraclass correlation coefficient, were best with SPECT-35%, followed by planar RNA and then SPECT-QBS, respectively. The sample size needed to objectify a change in a parameter of LV function is lowest with SPECT-35%, followed by planar RNA and then SPECT-QBS, respectively. CONCLUSIONS: The SPECT-35% processing method provides excellent interstudy precision and reliability for LV function measurement. In this aspect it seems to be better than planar RNA and SPECT-QBS. These results need to be confirmed in a larger patient population.

Coronary Artery Disease↗

Localization of coronary artery disease with exercise electrocardiography: correlation wit thallium-201 myocardial perfusion scanning.

In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery.

Coronary Disease↗

Different clinical and prognostic significance of painful and silent myocardial ischemia detected by exercise electrocardiography and dobutamine stress echocardiography after uncomplicated myocardial infarction.

Prevalence and prognostic significance of painful and silent ischemia detected by exercise electrocardiography (ECG) and dobutamine stress echocardiography (DSE) were evaluated in 407 consecutive patients recovering from acute myocardial infarction. Painful ischemia assessed by both tests was not associated with different clinical characteristics of patients; on the other hand, it identified a higher risk subgroup compared with silent ischemia during exercise ECG but not during DSE.

Aged↗

Accurate placement of central venous catheters in pediatric patients using endocavitary electrocardiography: reassessment of a personal technique.

To avoid the need for radiological control in the assessment of the proper location of central venous catheters (CVC), a particular use of endocavitary electrocardiography (EC-ECG) was proposed 10 years ago. The aim of this study is to reassess our experience with this method. EC-ECG assumes that the CVC, when filled with normosaline and connected to a standard electrocardiograph, behaves like an exploring electrode. The approach of the catheter tip to the right atrium is then detected by a slightly increasing negative P wave. When the tip reaches the exact level of the sinus node, the P wave suddenly deepens. After a preliminary test of the reliability of the technique versus the standard method in 50 CVC placements verified by both EC-ECG and chest x-ray, we have placed 807 CVCs in children using EC-ECG only. There have been no false-positive and one false-negative test result (lead connector misplacement). In 17 cases in which intrinsic deflection was not detected, the catheter tip was found to be wrongly positioned; all the remainder CVCs have been successfully positioned. For 10 years this technique has proved to be a simple, safe, quick, inexpensive and highly reliable method to assess the correct positioning of the CVC.

Adolescent↗

Assessment of left ventricular diastolic function with electrocardiography-gated myocardial perfusion SPECT: comparison with multigated equilibrium radionuclide angiography.

BACKGROUND: Technetium-labeled myocardial perfusion tracers allow the simultaneous assessment of myocardial perfusion and left ventricular function by electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT). This study evaluates left ventricular systolic and diastolic function by ECG-gated SPECT with the use of higher framing (32 frames per cardiac cycle) data acquisition. METHODS AND RESULTS: After receiving an injection of technetium 99m tetrofosmin, 48 patients with cardiac diseases were examined by ECG-gated myocardial perfusion SPECT with a 3-headed gamma camera. During gated data collection, 32 frames per cardiac cycle were acquired over 360 degrees in 60 steps, each of which consisted of 60 beats. Immediately thereafter, the 32 frames taken at each projection angle were combined into 16-frame and 8-frame data sets. Left ventricular end-diastolic volume (LVEDV, in milliliters), left ventricular end-systolic volume (LVESV, in milliliters), and left ventricular ejection fraction (LVEF, percentage) were automatically calculated from the 32-frame, 16-frame, and 8-frame gated data sets. Left ventricular time-volume curves from the 3 data sets were generated by Fourier curve fitting analysis with the use of 3 harmonics, and then peak filling rate (PFR, per second) was measured. Twenty-nine patients also underwent multigated equilibrium radionuclide angiography (ERNA) to determine the LVEF and PFR. Combining the 32-frame data into 16-frame and 8-frame data sets from the 48 patients generated a smaller LVEDV and a larger LVESV, and LVEF was significantly lower in accordance with the decreasing number of frames. Compared with ERNA studies (n = 29), the Bland-Altman method showed underestimated LVEFs and larger 95% limits of agreement in lower framing gated SPECT. CONCLUSIONS: Left ventricular functional parameters obtained from 32-frame gated SPECT correlated closely with those determined by ERNA studies. ECG-gated SPECT with 32-frame data can provide comprehensive information with which to evaluate many types of cardiac diseases.

Adult↗

A new method for regularization parameter determination in the inverse problem of electrocardiography.

Computing the potentials on the heart's epicardial surface from the body surface potentials constitutes one form of the inverse problem of electrocardiography. An often-used approach to overcoming the ill-posed nature of the inverse problem and stabilizing the solution is via zero-order Tikhonov regularization, where the squared norms of both the surface potential residual and the solution are minimized, with a relative weight determined by a so-called regularization parameter. This paper looks at the composite residual and smoothing operator (CRESO) and L-curve methods currently used to determine a suitable value for this regularization parameter, t, and proposes a third method that works just as well and is much simpler to compute. This new zero-crossing method selects t such that the squared norm of the surface potential residual is equal to t times the squared norm of the solution. Its performance was compared with those of the other two methods, using three stimulation protocols of increasing complexity. The first of these protocols involved a concentric spheres model for the heart and torso and three current dipoles placed inside the inner sphere as the source distribution. The second replaced the spheres with realistic epicardial and torso geometries, while keeping the three-dipole source configuration. The final simulation kept the realistic epicardial and torso geometries, but used epicardial potential distributions corresponding to both normal and ectopic activation of the heart as the source model. Inverse solutions were computed in the presence of both geometry noise, involving assumed erroneous shifts in the heart position, and of Gaussian measurement noise added to the torso surface potentials. It was verified that in an idealistic situation, in which correlated geometry noise dominated the uncorrelated Gaussian measurement noise, only the CRESO approach arrived at a value for t. Both L-curve and zero-crossing approaches did not work. Once measurement noise dominated geometry noise, all three approaches resulted in comparable t values. It was also shown, however, that often under low measurement noise conditions none of the three resulted in an optimum solution.

Artifacts↗

Generalized eigensystem techniques for the inverse problem of electrocardiography applied to a realistic heart-torso geometry.

We have previously proposed two novel solutions to the inverse problem of electrocardiography, the generalized eigensystem technique (GES) and the modified generalized eigensystem technique (tGES), and have compared these techniques with other numerical techniques using both homogeneous and inhomogeneous eccentric spheres model problems. In those studies we found our generalized eigensystem approaches generally gave superior performance over both truncated singular value decomposition (SVD) and zero-order Tikhonov regularization (TIK). In this paper we extend the comparison to the case of a realistic heart-torso geometry. With this model, the GES and tGES approaches again provide smaller relative errors between the true potentials and the numerically derived potentials than the other methods studied. In addition, the isopotential maps recovered using GES and tGES appear to be more accurate than the maps recovered using either SVD and TIK.

Animals↗

The Laplacian inverse problem of electrocardiography: an eccentric spheres study.

The eccentric spheres model of the heart-torso system is used to study the inverse problem of electrocardiography using measurements of the Laplacian of the body surface potential distribution. Electrical activity is simulated on the six main regions of the inner surface by considering a limited number of current dipoles placed within the inner sphere. The resulting outer surface potential and Laplacian distributions are then calculated in a forward sense. Varying amounts of random noise are added to these distributions before a zero-order Tikhonov regularization scheme is used to recover the inner surface potential distribution. Comparing the calculated and original inner surface distributions indicates that measurements of the outer surface Laplacian can more accurately reconstruct epicardial potentials than measurements of the outer surface potentials. These distributions are more accurate in that the extrema are placed very close to their original positions and are of nearly the same magnitude. Also, multiple extrema and high potential gradients are recovered.

Artifacts↗

Serial exercise thallium myocardial perfusion scanning and exercise electrocardiography in the diagnosis of coronary artery disease.

Serial exercise thallium-201 myocardial perfusion scanning (exercise and 4-hour redistribution) was compared to rest and exercise electrocardiography (ECG) for the detection of coronary artery disease in 125 patients with known or suspected coronary artery disease. All patients underwent coronary arteriography and 108 were found to have significant coronary artery lesions. The serial exercise thallium scan was significantly more sensitive than rest and exercise ECG in detecting coronary artery disease (94% v. 83% P less than 0.01). The sensitivity of a reversible thallium perfusion scan abnormality and a positive exercise ECG for detecting exercise induced myocardial ischaemia in coronary artery disease was similar (69% v. 63%). The exercise thallium scan complemented the exercise ECG, and the sensitivity of the combined test was significantly greater than the exercise ECG alone (84% v. 63% P less than 0.001). The specificity for coronary artery disease of the exercise ECG was 65% and that of the exercise thallium-201 myocardial perfusion scan was 82% (P = NS). Thallium-201 myocardial perfusion scanning complements the rest and exercise ECG in the non-invasive detection of coronary artery disease.

Adult↗

A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography--a randomised controlled study.

OBJECTIVE: To examine whether intrapartum monitoring by means of automatic ST analysis (STAN) of fetal electrocardiography could reduce the rate of neonatal acidemia and the rate of operative intervention during labour, compared with monitoring by means of cardiotocography (CTG). DESIGN: Randomised controlled trial. SETTING: Labour ward in tertiary-level university hospital. SAMPLE: A total of 1483 women in active labour with singleton term fetus in cephalic presentation. METHODS: Women were randomly assigned to be monitored either by STAN or by CTG. Fetal blood sampling (FBS) was optional in both groups. MAIN OUTCOME MEASURES: Neonatal acidemia (umbilical artery pH <7.10), neonatal metabolic acidosis (umbilical artery pH <7.05 and base excess <-12 mmol/l) and operative interventions: caesarean section rate, vacuum outlet (VO) rate and FBS rate. RESULTS: There were no statistically significant differences between the STAN group and CTG group in the incidence of neonatal acidemia (5.8 versus 4.7%) or metabolic acidosis (1.7 versus 0.7%). The caesarean section rate (6.4 versus 4.7%) and the VO rate (9.5 versus 10.7%) were also similar in the STAN and CTG groups. The incidence of FBS was lower (P < 0.001) in the STAN group (7.0%) than in the CTG group (15.6%). CONCLUSIONS: Intrapartum fetal monitoring by means of automatic STAN did not improve the neonatal outcome or decrease the caesarean section rate. However, the need for FBS during labour was lower in the STAN group.

Acidosis↗

Incremental prognostic value of stress echocardiography as an adjunct to exercise electrocardiography after uncomplicated myocardial infarction.

OBJECTIVE: To assess the prognostic value of stress echocardiography as an adjunct to exercise electrocardiography in patients with uncomplicated acute myocardial infarction. DESIGN: 496 patients underwent a maximum exercise ECG and pharmacological stress echocardiography (406 dobutamine and 90 dipyridamole) within 15 days of uncomplicated acute myocardial infarction and were followed for a mean of 25 months (range 1-74 months) for reinfarction, unstable angina, and cardiac death. Patients undergoing revascularisation were omitted. RESULTS: Exercise ECG was positive in 162 patients (32.6%) and low threshold positive (< 100 W) in 91 (18%). Stress echocardiography was positive in 239 patients (48%) (194 with dobutamine and 45 with dipyridamole stress). The agreement between the two tests was 63% (kappa = 0.24, 95% confidence interval 0.15 to 0.33). Sixty nine spontaneous events occurred (14 cardiac deaths, 26 reinfarctions, and 29 with unstable angina requiring hospital admission), and 126 patients underwent revascularisation (39 coronary angioplasty and 87 bypass surgery). By receiver operating characteristic curve analysis, stress echocardiography provided incremental prognostic information compared with clinical data. A low threshold positive exercise ECG was associated with a worse outcome, but there was a fivefold increase in risk in patients with positive stress echocardiography who also had a high threshold (> 100 W) positive exercise ECG. Event-free survival of patients with both tests positive was significantly less than in patients with only one positive test or with both tests negative. CONCLUSIONS: Stress echocardiography provides additional prognostic information after uncomplicated acute myocardial infarction, but the greatest gain is found in patients with a high threshold positive exercise ECG.

Cardiotonic Agents↗