PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microelectrodes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Constraining the connectivity of neuronal networks cultured on microelectrode arrays with microfluidic techniques: a step towards neuron-based functional chips.

In vitro culture of small neuronal networks with pre-defined topological features is particularly desirable when the electrical activity of such assemblies can be monitored for long periods of time. Indeed, it is hoped that such networks, with pre-determined connectivity, will provide unique insights into the structure/function relationship of biological neural networks and their properties of self-organization. However, the experimental techniques that have been developed so far for that purpose have either failed to provide very long-term pattern definition and retention, or they have not shown potential for integration into more complex microfluidic devices. To address this problem, three-dimensional microfluidic systems in poly(dimethylsiloxane) (PDMS) were fabricated and used in conjunction with both custom-made and commercially available planar microelectrode arrays (pMEAs). Various types of primary neuronal cell cultures were established inside these systems. Extracellular electrical signals were successfully recorded from all types of cells placed inside the patterns, and this bioelectrical activity was present for several weeks. The advantage of this approach is that it can be further integrated with microfluidic devices and pMEAs to yield, for example, complex neuron-based biosensors or chips for pharmacological screening.

Action Potentials↗

Measurement of electrical activity of long-term mammalian neuronal networks on semiconductor neurosensor chips and comparison with conventional microelectrode arrays.

Based on complementary metal-oxide semiconductor (CMOS) technology a neurosensor chip with passive palladium electrodes was developed. The CMOS technology allows a high reproducibility of the sensors as well as miniaturization and the on-chip integration of electronics. Networks of primary neurones were taken from murine foetal spinal cord (day 14) and frontal cortex (day 15) tissues and cultured on the silicon surface in a chamber volume of 200 microl with 7 mm diameter. Measurements were performed between days 15 and 59 in vitro. Signals were recorded from both types of cultures. To test the capability of the system to detect pharmacologically induced activity changes two established neuromodulators were applied. The GABA(A)-receptor blocker bicuculline was applied to both tissue cultures, the glycine-receptor blocker strychnine to spinal cord cultures. Four network frequency parameters were analysed: spike rate (SR), burst rate (BR), frequency in bursts (FiB) and peak frequency in bursts (PFiB). Significant changes of spike rate and burst rate were measured with spinal cord cultures after bicuculline application. Significant changes of frequency in bursts and peak frequency in bursts were observed with frontal cortex cultures after bicuculline application. Significant changes of spike rate and frequency in bursts were recorded with spinal cord cultures after strychnine application. These results were compared with results achieved in the same laboratory by using glass-microelectrode arrays (MEAs). This comparison showed for spinal cord similar native spike and burst rate, but higher mean frequency and peak frequency in bursts, whereas frontal cortex activity had higher spike and burst rate and peak frequency in bursts. Application of bicuculline or strychnine to spinal cord networks showed stronger effects on MEAs, whereas with frontal cortex networks the modulation of activity was similar after application of bicuculline.

Action Potentials↗

Immunoassays based on microelectrodes arrayed on a silicon chip for high throughput screening of liver fibrosis markers in human serum.

A novel immunoassays for screening of disease markers in human serum are presented by miniaturizing interdigitated array (IDA) of microelectrodes via micro electro-mechanical system (MEMS) on a silicon chip for multi-channel electrochemical measurement. Different selected antibodies (Abs) are incorporated site-specifically into the electrochemically deposited polypyrrole (PPy) formed on the IDA of the silicon chip, which was characterized by fluorescence microscope photo and the electrochemical quartz crystal microbalance (EQCM) measurements. The selective recognition of Ab to the corresponding antigen (Ag) is monitored through the measurable conductivity change, which is directly visualized by cyclic voltammograms (CVs) in presence of the redox probe, Fe (CN)6(3-/4-). By using the strategy presented here, three liver fibrosis markers, hyaluronic acid (HA), lamin (LN) and collagen type IV (IV-C), are detected simultaneously and specifically at the surface of the chip with calibration curves, y = 21.75 + 0.84x (R = 0.995), y = 57.54 + 0.47x (R = 0.999) and y = 37.92 + 0.28x (R = 0.999), separately. Either the standard or the serum samples can be detected at ng/mL concentration level in a tiny amount of volume, approximately 50 microL. The chip-based immunoassay shows the advantages of high sensitivity, good specificity, high throughput, low sample consumption, and the stability offered via batch production by MEMS as well, which is expected to benefit the multi-target screening of desired clinical analytes.

Biomarkers↗

Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples.

An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli O157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5)CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC=15.55 N-71.04 with R(2)=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min.

Antibodies↗

Microelectrode array-based system for neuropharmacological applications with cortical neurons cultured in vitro.

Microelectrode arrays (MEAs) provide a means to investigate the electrophysiological behavior of neuronal systems through the measurements from neuronal culture preparations. Changes in activity patterns of neuronal networks are usually detected by applying neural chemicals. Because of the difficulties of fabricating the arrays, and the delicate and less reliable properties of cortical neurons, MEA-based systems with cortical neuronal networks for neurophamacological applications are technically difficult, therefore restricting their utility. Here, we report a new approach to the development of such MEA-based system with sensitive and durable MEAs conveniently fabricated and the culture conditions optimized. Upon growth differentiation, cortical neurons, cultured directly on MEAs, reach a developmentally stable and reliable activity state. With this system, we monitored the global spontaneous activities of neuronal networks and demonstrated the fine discrimination for specific substances and unique property of cortical neurons, which validated both the applicability and necessity of such system in pharmacological bioassay.

Action Potentials↗

Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes.

We have fabricated a label-free electrochemical immunosensor using microelectrode arrays modified with single-walled carbon nanotubes (SWNTs). Label-free detection of a cancer marker, total prostate-specific antigen (T-PSA), was carried out using differential pulse voltammetry (DPV). The current signals, derived from the oxidation of tyrosine (Tyr), and tryptophan (Trp) residues, increased with the interaction between T-PSA on T-PSA-mAb covalently immobilized on SWNTs. The selectivity of our biosensor was challenged using bovine serum albumin (BSA) as the target protein. The detection limit for T-PSA was determined as 0.25 ng/mL. Since the cut-off limit of T-PSA between prostate hyperplasia and cancer is 4 ng/mL, the performance of our label-free electrochemical immunosensor seems promising for further clinical applications.

Biosensing Techniques↗

Functional re-establishment of the perforant pathway in organotypic co-cultures on microelectrode arrays.

Co-cultures of entorhinal cortex (EC) and dentate gyrus (DG) explants are a useful model system to study the formation and stabilization of axonal projections. We adapted this model system to EC-DG co-cultures on microelectrode arrays (MEA) for the characterization of axonal projections on a functional level for days and weeks. EC and DG explants were placed on MEA to allow for the reconstitution of perforant pathway projections. Connections formed were characterized by morphological and electrophysiological analyses to verify characteristic features of perforant pathway signal transmission. Morphological analysis reveals proper projection of EC neurons into the molecular layer of the DG. Examination of synaptic transmission after high frequency stimulation imply unidirectional connections that used glutamate receptors of the AMPA/kainate type as main mediators of excitatory signal transmission. The system was evaluated by the introduction of the NCAM binding peptide C3d. In accordance with in vivo and in vitro experiments C3d modulated signal transmission by NCAM-related mechanisms resulting in morphological re-arrangements.

6-Cyano-7-nitroquinoxaline-2,3-dione↗

Ion transport mechanisms in the mesonephric collecting duct system of the toad Bufo bufo: microelectrode recordings from isolated and perfused tubules.

It is not clear how and whether terrestrial amphibians handle NaCl transport in the distal nephron. Therefore, we studied ion transport in isolated perfused collecting tubules and ducts from toad, Bufo bufo, by means of microelectrodes. No qualitative difference in basolateral cell membrane potential (Vbl) was observed between tubules and ducts in response to ion substitutions, inhibitor and agonist applications. Cl- substitution experiments indicated a small Cl- conductance in the basolateral membrane. The apical membrane did not have a significant Cl- conductance. Luminal [Na+] steps and amiloride application showed a small apical Na+ conductance. Arginine vasotocin depolarized Vbl. The small apical Na+ conductance indicates that the collecting duct system contributes little to NaCl reabsorption when compared to aquatic amphibians. In contrast, Vbl rapidly depolarized upon lowering of [Na+] in the bath, demonstrating the presence of a Na+-coupled anion transporter. [HCO3-] steps revealed that this transporter is not a Na+-HCO3- cotransporter. Together, our results indicate that a major task of the collecting duct system in B. bufo is not conductive NaCl transport but rather K+ secretion, as shown by our previous studies. Moreover, our results indicate the presence of a novel basolateral Na+-coupled anion transporter, the identity of which remains to be elucidated.

Animals↗

Dynamic and static calcium gradients inside large snail (Helix aspersa) neurones detected with calcium-sensitive microelectrodes.

We have used quartz Ca2+-sensitive microelectrodes (CASMs) in large voltage-clamped snail neurones to investigate the inward spread of Ca2+ after a brief depolarisation. Both steady state and [Ca2+]i transients changed with depth of penetration. When the CASM tip was within 20 microm of the far side of the cell the [Ca2+]i transient time to peak was 4.4+/-0.5s, rising to 14.7+/-0.7s at a distance of 80 microm. We estimate that the Ca2+ transients travelled centripetally at an average speed of 6 microm2 s(-1) and decreased in size by half over a distance of about 45 microm. Cyclopiazonic acid had little effect on the size and time to peak of Ca2+ transients but slowed their recovery significantly. This suggests that the endoplasmic reticulum curtails rather than reinforces the transients. Injecting the calcium buffer BAPTA made the Ca2+ transients more uniform in size and increased their times to peak and rates of recovery near the membrane. We have developed a computational model for the transients, which includes diffusion, uptake and Ca2+ extrusion. Good fits were obtained with a rather large apparent diffusion coefficient of about 90+/-20 microm2 s(-1). This may assist fast recovery by extrusion.

Animals↗

Ion selectivity of a poly(3-pentylmethoxythiophene) LB-layer modified carbon-fiber microelectrode as a consequence of the second order filtering in voltcoulometry.

Ion selective properties of poly(3-pentylmethoxythiophene) Langmuir-Blodgett film modified carbon-fiber microelectrode are described. The study of the electrode behavior indicates that important features occur if two electrochemical methods, one of them being kinetics sensitive, are used. While in case of the typical steady-state voltammetry the electrode remains sensitive to both the cations and anions, the kinetics-sensitive properties of voltcoulometry based on the second-order filtering scheme disable the observation of anions. As a model system a mixture of copper and dopamine ions is used.

Carbon↗

Microelectrodes and their use to assess ion channel function.

Impalement of living cells with microelectrodes (MEs) is a useful approach to measure a variety of biological parameters such as membrane potential (Vm), intracellular free ion concentrations and cell-to-cell communication. Despite such widespread applications, the number of trained researchers capable of using MEs is diminishing. In this article, we describe the fundamentals of the preparation and the proper use of MEs to study the physiology of transepithelial ion transport.

Animals↗

The role of electrode impedance and electrode geometry in the design of microelectrode systems.

Microelectromechanical systems (MEMS) employing spatially and/or temporally nonuniform electric fields have been extensively employed to control the motion of suspended particles or fluid flow. Design and control of microelectromechanical processes require accurate calculations of the electric field distribution under varying electrolyte conditions. Polarization of electrodes under the application of an oscillating voltage difference produces dynamic electrical double layers. The capacitive nature of the double layers significantly inhibits the penetration of the electric field through the double layer and into the surrounding bulk electrolyte at low frequencies. This paper quantitatively discusses the effect of electrode impedance on the electric field distribution as a function of field frequency, electrolyte composition, and electrode zeta potential in microelectrode systems. The design principles for the electrode geometry and configuration are also discussed in terms of their effects on the electric field magnitude and nonuniformity.

Electrodes↗

Microelectrode arrays: a new tool to measure embryonic heart activity.

The analysis of the sequential excitation of cardiac tissue is of high relevance, both for clinical pathophysiological purposes, eg, detection of sustained ventricular arrhythmias, as well as for experimental electrophysiology. Clinically, different technical approaches such as single electrode measurements and bipolar mapping electrode catheters have been used. In experimental setups several techniques to record cardiac activity have been proposed. Beside the well-established intracellular current-clamp recordings of action potentials, recent studies have performed extracellularly activation sequence mapping or simultaneous multichannel action potential electrode array measurements. Measurement of extracellularly recorded field potentials (FPs) hereby especially provides detailed information about the origin and spread of excitation in the heart. A similar analytical approach for cardiac FPs advanced the analysis of excitation spread and arrhythmic activity in multicellular preparations like developmental differentiation tissue of mouse embryonic stem cells, multicellular preparations of isolated native embryonic cardiomyocytes or the embryonic heart in toto. The use of substrate-integrated Microelectrode Arrays (MEAs, Multi Channel Systems, Reutlingen, Germany) with 60 electrodes of 10-30 microm diameters on a 100-200 microm grid, coated with porous titanium nitride to minimize the impedance allows recording of FPs at a high signal to noise ratio. The possibility to electrically stimulate the tissue further expands the range of applications and bioassays. It may thus facilitate the evaluation of drug research providing detailed information about the interplay of the complex cardiac network, and might improve the predictability of physiological and pathophysiological conditions or drug effects in embryonic heart tissue.

Action Potentials↗

Wireless transmission of fast-scan cyclic voltammetry at a carbon-fiber microelectrode: proof of principle.

Fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) provides exquisite temporal and spatial resolution for monitoring brain chemistry. The utility of this approach has recently been demonstrated by measuring sub-second dopamine changes associated with behavior. However, one drawback is the cable link between animal and recording equipment that restricts behavior and precludes monitoring in complex environments. As a first step towards developing new instrumentation to overcome this technical limitation, the goal of the present study was to establish proof of principle for the wireless transmission of FSCV at a CFM. Proof of principle was evaluated in terms of measurement stability, fidelity, and susceptibility to ambient electrical noise. Bluetooth digital telemetry provided bi-directional communication between remote and home-base units and stable, high-fidelity data transfer comparable to conventional, wired systems when tested using a dummy cell (i.e., a resistor and capacitor in series simulating electrical properties of a CFM), and dopamine measurements with flow injection analysis and in the anesthetized rat with electrical stimulation. The wireless system was also less susceptible to interference from ambient electrical noise. Taken together, the present findings establish proof of principle for the wireless transmission of FSCV at a CFM.

Animals↗

A floating metal microelectrode array for chronic implantation.

Implantation of multi-electrode arrays is becoming increasingly more prevalent within the neuroscience research community and has become important for clinical applications. Many of these studies have been directed towards the development of sensory and motor prosthesis. Here, we present a multi-electrode system made from biocompatible material that is electrically and mechanically stable, and employs design features allowing flexibility in the geometric layout and length of the individual electrodes within the array. We also employ recent advances in laser machining of thin ceramic substrates, application of ultra-fine line gold conductors to ceramic, fabrication of extremely flexible cables, and fine wire management techniques associated with juxtaposing metal microelectrodes within a few hundred microns of each other in the development of a floating multi-electrode array (FMA). We implanted the FMA in rats and show that the FMA is capable of recording both spikes and local field potentials.

Animals↗

Low-density neuronal networks cultured using patterned poly-l-lysine on microelectrode arrays.

Synaptic activity recorded from low-density networks of cultured rat hippocampal neurons was monitored using microelectrode arrays (MEAs). Neuronal networks were patterned with poly-l-lysine (PLL) using microcontact printing (microCP). Polydimethysiloxane (PDMS) stamps were fabricated with relief structures resulting in patterns of 2 microm-wide lines for directing process growth and 20 microm-diameter circles for cell soma attachment. These circles were aligned to electrode sites. Different densities of neurons were plated in order to assess the minimal neuron density required for development of an active network. Spontaneous activity was observed at 10-14 days in networks using neuron densities as low as 200 cells/mm(2). Immunocytochemistry demonstrated the distribution of dendrites along the lines and the location of foci of the presynaptic protein, synaptophysin, on neuron somas and dendrites. Scanning electron microscopy demonstrated that single fluorescent tracks contained multiple processes. Evoked responses of selected portions of the networks were produced by stimulation of specific electrode sites. In addition, the neuronal excitability of the network was increased by the bath application of high K(+) (10-12 mM). Application of DNQX, an AMPA antagonist, blocked all spontaneous activity, suggesting that the activity is excitatory and mediated through glutamate receptors.

Action Potentials↗

An automated microdrop delivery system for neuronal network patterning on microelectrode arrays.

The aim of this work is to present a new technique for defining interconnected sub-populations of cultured neurons on microelectrode arrays (MEAs). An automated microdrop delivery technique allows to design and realize spatially distributed neuronal ensembles by depositing sub-nanoliter volumes of adhesion molecules in which neurons grow and develop. Electrophysiological tests demonstrate that functionally interconnected clusters are obtained and experimental results (both spontaneous and stimulus evoked activity recordings) attesting the feasibility of the proposed approach are presented. By means of the automated system, different and specific architectures can be easily designed and functionally studied. In the presented system the speed of drop deposition is about 30 drops/min; the mean diameter is 147 microm; typical cell survival time is 4-5 weeks. By changing drop size and spacing, investigations about how the network dynamics is related to the network structure can be systematically carried out.

Age Factors↗

Cortical stimulation mapping using epidurally implanted thin-film microelectrode arrays.

Stimulation mapping of motor cortex is an important tool for assessing motor cortex physiology. Existing techniques include intracortical microstimulation (ICMS) which has high spatial resolution but damages cortical integrity by needle penetrations, and transcranial stimulation which is non-invasive but lacks focality and spatial resolution. A minimally invasive epidural microstimulation (EMS) technique using chronically implanted polyimide-based thin-film microelectrode arrays (72 contacts) was tested in rat motor cortex and compared to ICMS within individual animals. Results demonstrate reliable mapping with high reproducibility and validity with respect to ICMS. No histological evidence of cortical damage and the absence of motor deficits as determined by performance of a motor skill reaching task, demonstrate the safety of the method. EMS is specifically suitable for experiments integrating electrophysiology with behavioral and molecular biology techniques.

Analysis of Variance↗