PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Highly sensitive analysis of methamphetamine and amphetamine in human whole blood using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A simple and highly sensitive method for analysis of derivatized methamphetamine (MA) and amphetamine (AM) in whole blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry electron impact ionization selected ion monitoring (GC-MS-EI-SIM). A whole blood sample, deuterated-MA (d(5)-MA), as an internal standard (IS), tri-n-propylamine and pentafluorobenzyl bromide were placed in a vial. The vial was heated and stirred at 90 degrees C for 30min. Then the extraction fiber of the SPME was exposed at 90 degrees C for 30min in the headspace of the vial while being stirred. The derivatives adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves showed linearity in the range of 0.5-1000ng/g for both MA and AM. The time for analysis was about 80min per sample. In addition, this proposed method was applied to two autopsy cases where MA ingestion was suspected. In one case, MA and AM concentrations in the mixed left and right heart blood were 165 and 36.9ng/g, respectively. In the other case, MA and AM concentrations were 1.79 and 0.119 microg/g in the left heart blood, and 1.27 and 0.074 microg/g in the right heart blood, respectively.

Adsorption↗

Automated in-tube solid-phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry for the determination of beta-blockers and metabolites in urine and serum samples.

The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. LC/MS analyses of beta-blockers were initially performed by liquid injection onto a LC column. Nine beta-blockers tested in this study gave very simple ESI mass spectra, and strong signals corresponding to [M + H]+ were observed for all beta-blockers. The beta-blockers were separated with a Hypersil BDS C18 column using acetonitrile/methanol/water/acetic acid (15:15:70:1) as a mobile phase. To optimize the extraction of beta-blockers, several in-tube SPME parameters were examined. The optimum extraction conditions were 15 draw/eject cycles of 30 microL of sample in 100 mM Tris-HCl (pH 8.5) at a flow rate of 100 microL/min using an Omegawax 250 capillary (Supelco, Bellefonte, PA). The beta-blockers extracted by the capillary were easily desorbed by mobile-phase flow, and carryover of beta-blockers was not observed. Using in-tube SPME/LC/ESI-MS with selected ion monitoring, the calibration curves of beta-blockers were linear in the range from 2 to 100 ng/mL with correlation coefficients above 0.9982 (n = 18) and detection limits (S/N = 3) of 0.1-1.2 ng/mL. This method was successfully applied to the analysis of biological samples without interference peaks. The recoveries of beta-blockers spiked into human urine and serum samples were above 84 and 71%, respectively. A serum sample from a patient administrated propranolol was analyzed using this method and both propranolol and its metabolites were detected.

Adrenergic beta-Antagonists↗

Monitoring of the principal carbonyl compounds involved in malolactic fermentation of wine by solid-phase microextraction and positive ion chemical ionization GC/MS analysis.

A new method has been developed to determine acetaldehyde, 2,3-butanedione (diacetyl) and 3-hydroxy-2-butanone (acetoin) in wine by solid-phase microextraction (SPME) and positive ion chemical ionization GC/MS analysis of O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBOA) derivatives. For SPME, a 65-microm PEG/DVB fibre was used; chemical ionization was performed with methane as reagent gas. The best analysis-time/sensitivity compromise was to perform the PFBOA reaction at 50 degrees C for 20 min, followed by 5-min SPME at the same temperature. Quantitative analysis was performed in SCAN mode using o-chlorobenzaldehyde as internal standard (IS), on the signal of the [M + H](+) ion at m/z 240 for acetaldehyde, 266 for acetoin (corresponding to the [M + H - 18](+) ion), 282 for diacetyl (protonated mono-derivatized compound), and 336 for IS. The accuracy and repeatability of the method were suitable for the study aims, and linearity was good in the range of concentration studied, with correlation coefficients of calibration curves 0.997, 0.998 and 0.988 for acetaldehyde, diacetyl and acetoin respectively. Due to the higher polarity of acetoin with respect to other two compounds, lower sensitivity in the detection of this compound was observed. By following the variation of the three carbonyl compounds, malolactic fermentations (MLF) were monitored in Merlot wines and this was carried out in the laboratory by two different bacteria strains.

Acetaldehyde↗

Development of a personal isocyanate sampler based on DBA derivatization on solid-phase microextraction fibers.

The design and evaluation of a portable diffusive sampler for isocyanates is described. The sampler employs dibutylamine (DBA) loaded onto 60-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) solid-phase microextraction (SPME) fibers. The DBA-isocyanate derivative is then desorbed by sonication and analyzed by LC-MS using atmospheric pressure chemical ionization (APCI). The samplers are calibrated (i.e. the uptake rate is calculated) by exposing them to a known concentration of hexamethylene diisocyanate (HDI) in a standard gas-generation chamber. The uptake rate for the proposed method, at room temperature (25 degrees C), is 1.13 pg (min ppb(v))(-1) and the method detection limit is 3.2 microg m(-3), equivalent to less than 10% of the airborne time-weighted average (TWA) exposure limits recommended by both the National Institute for Occupational Safety and Health (NIOSH) and the American Conference of Governmental Industrial Hygienists (ACGIH). Practical points that should be considered when using the SPME device as a diffusive sampler are discussed.

Air Pollutants, Occupational↗

Application of solid-phase microextraction for determining phenylurea herbicides and their homologous anilines from vegetables.

Residues of metobromuron, monolinuron and linuron herbicides and their aniline homologous were analyzed in carrots, onions and potatoes by solid-phase microextraction (SPME) performed with a polyacrylate fiber. A juice was obtained from food samples that were further diluted, and an aliquot was extracted after sodium chloride (14%) addition and pH control. At pH 4 only the phenylureas were extracted. A new extraction at pH 11 allowed the extraction of phenylureas plus homologous aniline metabolites. Determination was carried out by gas chromatography with nitrogen-phosporus detection (NPD) the identity of the determined compounds was studied by gas chromatography-mass spectrometry. Limits of quantification (LOQs) obtained with NPD and MS (selected-ion monitoring) were in the microg/kg order allowing determination of maximum residue levels (MRLs) established in the Spanish regulations. MRLs ranged from 0.02 to 0.1 mg/kg depending on the kind of food and herbicide. Under the proposed conditions matrix effects were low enough to permit calibration with samples proceeding from ecological (non-pesticide treated) crops. Twelve commercial samples of each carrots, onions and potatoes were analyzed and only three samples of potatoes contained residues of linuron at levels below MRLs.

Aniline Compounds↗

Volatile sulfur compounds in Cheddar cheese determined by headspace solid-phase microextraction and gas chromatograph-pulsed flame photometric detection.

The aim of this study was to develop a methodology for the analysis of volatile sulfur compounds (VSCs) in Cheddar cheese. Solid-phase microextraction (SPME) was employed to extract VSCs from the cheese matrix using a CAR-PDMS fiber. This extraction method was combined with gas chromatography-pulsed flame photometric detection (GC-PFPD) to achieve high sensitivity for sulfur compounds. The impact of extraction parameters, including time, temperature and sample size, was evaluated to determine the best conditions to analyze sulfur compounds in Cheddar cheese. Hydrogen sulfide, methanethiol, and dimethyl sulfide were found to constitute the majority of the overall sulfur profile while dimethyl disulfide and dimethyl trisulfide were present in lesser amounts. Artifact formation of volatile sulfur compounds was found to be minimal. Two commercial cheese samples were analyzed and differences in sulfur content were observed. Overall, SPME-GC-PFPD was found to be a highly sensitive technique for the analysis of sulfur compounds in Cheddar cheese.

Artifacts↗

Development of a procedure for the determination of perfluorocarboxylic acids in sediments by pressurised fluid extraction, headspace solid-phase microextraction followed by gas chromatographic-mass spectrometric determination.

A procedure for the determination of perfluorocarboxylic acids (i.e. PFC7-10A) in sediment by pressurized fluid extraction (PFE), derivatization, headspace solid-phase microextraction and GC-MS determination in the negative ion chemical ionisation mode was developed. The PFE extraction variables such as solvent composition, number and time per extraction cycle, and extraction temperature were optimised. In the optimum extraction conditions, recoveries exceeding 95% with a limit of detection and RSDs of 0.5-0.8 ng g(-1) and 15.5-16.8%, respectively, were obtained. The developed analytical procedure was applied to harbour sediments where PFC8A and PFC10A were detected for the first time at low ppb concentrations (i.e. 8-11 ng g(-1).

Carboxylic Acids↗

Comparative application of solid-phase microextraction fibre assemblies and semi-permeable membrane devices as passive air samplers for semi-volatile chlorinated organic compounds. A case study on the landfill "Grube Antonie" in Bitterfeld, Germany.

Solid phase microextraction (SPME) fibres coated with Carbowax/divinylbenzene and semi-permeable membrane devices (SPMDs) of standard configuration were used to obtain time-weighted average (TWA) field air concentrations of selected chlorinated semi-volatile compounds on a landfill, where large amounts of lindane by-products were deposited, together with other hazardous chemical residues in the past. Additionally, spot sampling with SPME fibres was performed to identify the emission hotspot and sampling rates were determined/predicted for the substances of interest. Both samplers yield comparable TWA air concentrations of lindane and its isomers and of DDT with its metabolites and gain in certainty about the landfill as remaining source of air pollution with these compounds in the region. Both SPME fibres and SPMDs (respective their modifications) can be recommended as sampling tools in process studies and larger air monitoring programmes. However, further calibration studies and field tests are necessary to obtain reliable sampling rates for a wider range of semi-volatile compounds.

Air Pollutants↗

Rapid analysis of essential oil from Fructus Amomi by pressurized hot water extraction followed by solid-phase microextraction and gas chromatography-mass spectrometry.

In this paper, a simple, rapid, solvent-free and low-cost method of pressurized hot water extraction (PHWE) followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of essential oil in a traditional Chinese medicine (TCM) of the dried ripe fruit of Fructus Amomi (Sha Ren). The essential oil in the TCM (0.050 g) was extracted by water at 50 bar and 150 degrees C, followed by extraction and concentration by SPME fibers at 80 degrees C for 15min and analysis by GC-MS. The PHWE and HS-SPME parameters were optimized. Thirty-five compounds in the TCM were identified by PHWE-HS-SPME. Among them, camphor, an active compound, in the TCM samples was quantitatively analyzed. The proposed method required little time to prepare the sample. Moreover, little sample mass and no organic solvent was needed. The precision of the present method was found to be good (R.S.D. <10.0%). It is shown that PHWE-SPME-GC-MS is an alternative method for the determination of volatile components in TCMs and can be used as a powerful tool for TCM quality assessment.

Amomum↗

Competitive extraction of multi-component contaminants in water by Carboxen-polydimethylsiloxane fiber during solid-phase microextraction.

A headspace analysis for groundwater contaminated with BTEX (benzene, toluene, ethylbenzene, and xylenes) was employed to investigate the feasibility and limitations of Carboxen-PDMS (polydimethylsiloxane) fiber during SPME (solid-phase microextraction). Although the response of the Carboxen-PDMS fiber was much higher than that of conventional PDMS fiber, a reduction of the extracted amount was also observed under multi-component conditions due to competitive replacement. The general affinity of analytes to the fiber was high in the order xylene>ethylbenzene>toluene> benzene. The behavior of the Carboxen-PDMS fiber was examined more precisely at constant compositional ratio, because the analysis of contaminants using Carboxen-PDMS fiber was reported to be possible at known composition. The relative affinity of each component was shown to differ according to the total amount of analytes. Furthermore, the extracted amounts of benzene and toluene did not show a consistent tendency as the concentration of each component increased. These results indicate that caution should be exercised if Carboxen-PDMS fibers are used for the analysis of BTEX in groundwater samples.

Chromatography, Gas↗

Optimization of solid-phase microextraction conditions using a response surface methodology to determine organochlorine pesticides in water by gas chromatography and electron-capture detection.

A response surface methodology was applied to optimise the solid-phase microextraction (SPME) conditions using a polyacrylate-coated fiber to determine thirteen organochlorine pesticides from water. Analyses were performed using gas chromatography-electron-capture detection. Variables affecting absorption in both the headspace and immersion extraction were optimised by using a response surface generated with a Doehlert design, and the results were compared. The immersion SPME method was selected since higher recoveries were obtained for most of the compounds studied. The method developed was applied to the analysis of tap and Ebro river water samples. The linear range of most pesticides for real samples was found to be between 0.001 and 2.5 micrograms l-1 and the limits of detection were between 0.15 and 0.35 ng l-1. The repeatability and the reproducibility between days of the method (n = 6), expressed as relative standard deviation, for tap water spiked at a level of 1 ng l-1 were between 5.7 and 25.6% and between 7.6 and 26.5%, respectively.

Chromatography, Gas↗

Determination of amphetamine and methamphetamine in human hair by headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection.

A simple and rapid method for the determination of amphetamine (AP) and methamphetamine (MA) in human hair was developed by headspace solid-phase microextraction (SPME) and gas chromatography with nitrogen-phosphorus detection (GC-NPD). The hair (1 mg) was dissolved in 0.2 ml of a 5 M sodium hydroxide solution in a tightly sealed vial by shaking at 75 degrees C for about 5 min. In order to adsorb AP and MA on the SPME fiber, 100 microm of polydimethylsiloxane fiber was exposed to the headspace of the vial, and the vial was heated at 55 degrees C for 20 min. Then the fiber was removed from the vial and inserted into the injection port of the GC-NPD system using a CBJ-17 capillary column. The compounds adsorbed on the fiber were analyzed by exposing the fiber at 220 degrees C for 30 s in the GC injection port. By using this method, AP and MA in human hair could be analyzed simply and rapidly without any interference from coexisting substances. The percentages of AP and MA extracted from human hair by the SPME method were 48 and 62%, respectively, and relative standard deviations were below 10% (n=5). The calibration curves for AP and MA were linear in the ranges of 0.4-15 and 4-160 ng/mg hair, respectively. The detection limits of AP and MA at a signal-to-noise ratio of three were 0.1 and 0.4 ng/mg hair, respectively. This method could be applied to the analysis of an abuser's hair sample.

Amphetamine↗

Essential oil composition of sachalinmint from Norway detected by solid-phase microextraction and gas chromatography-mass spectrometry analysis.

The essential oil of leaves and flowers of sachalinmint [Mentha sachalinensis (Briq.) Kudô] grown in Norway (Trondheim) has been studied by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry analysis (GC-MS). The essential oil content increased linearly in acropetal direction from 1.08% (0-20 cm plant height) to 1.75% (60-80 cm; young leaves and flowers). The steam-distilled samples showed a minor complex matrix with a very high menthol and a much lower menthone content (87.89 and 4.05%, respectively). From testing of HS-SPME unequilibrated exposure times ranging from 10 s to 5 min, an extraction time of 30 s was found to be sufficient to detect both low- and high-eluting compounds. Comparison of HS-SPME and steam-distilled samples established that the same tendencies of increasing menthol/menthone content in the basipetal/acropetal direction could be detected by both analysis methods. With regard to the extraction efficiency, HS-SPME gave additional detailed information about less important terpenic compounds.

Gas Chromatography-Mass Spectrometry↗

Headspace solid phase microextraction and gas chromatography-olfactometry dilution analysis of young and aged Chinese "Yanghe Daqu" liquors.

The aroma compounds of young and aged Chinese "Yanghe Daqu" liquor samples were extracted by solid phase microextraction (SPME) and analyzed by gas chromatography (GC)-olfactometry dilution analysis. The original liquor samples were diluted with deionized water to give a final alcohol content of 14% (v/v). The samples were stepwise diluted (1:1) with 14% (by volume) ethanol-water solution and then extracted by headspace SPME. The samples were preequilibrated at 50 degrees C for 15 min and extracted with stirring at the same temperature for 30 min prior to injection into GC. The aroma compounds were identified by both GC-MS and GC-olfactometry using DB-Wax and DB-5 columns. The results suggested that esters were the major contributors to Yanghe Daqu liquor aroma. Ethyl hexanoate, ethyl butanoate, and ethyl pentanoate had very high flavor dilution values in both young and aged liquors (FD > 8192). Methyl hexanoate, ethyl heptanoate, ethyl benzoate, and butyl hexanoate could also be very important because of their high flavor dilution values (FD > or = 256). Moreover, two acetals, 1,1-diethoxyethane and 1,1-diethoxy-3-methylbutane, also were shown high flavor dilution values in Yanghe Daqu liquors (FD > or = 256). Other aroma compounds having moderate flavor dilution values included acetaldehyde, 3-methylbutanol, and 2-pentanol (FD > or = 32). Comparing young and aged liquors, the aroma profiles were similar, but the aroma compounds in the aged sample had higher flavor dilution values than in the young ones.

Alcoholic Beverages↗

Development of gas chromatography/mass spectrometry following headspace solid-phase microextraction for fast determination of asarones in plasma.

Asarones (alpha-asarone and beta-asarone) are the active components in the traditional Chinese medicine (TCM) of Acorus tatarinowii Schott, which has been used to treat epilepsy for several thousand years. To perform the pharmacokinetics (PK) study of alpha- and beta-asarone from the TCM essential oil, a simple, rapid and sensitive method was developed for the determination of asarones from the TCM in rabbit plasma, based on headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/mass spectrometry (GC/MS) with electron ionization (EI). The extraction parameters of headspace volume, fiber coating, sample temperature, extraction time, stirring rate and ion strength were systemically optimized. Furthermore, the method linearity, detection limit and precision were also investigated. It was shown that the proposed method provided a good linearity (0.02-20 microg/mL, R(2) > 0.99), low detection limit (<2.0 ng/mL) and good precision (RSD < 7.0%). Finally, HS-SPME followed by GC/MS was applied to fast determination of alpha- and beta-asarone in rabbit plasma at different time points after oral adminstration of the essential oil from A. tatarinowii. The experimental results suggest that the proposed method provides an alternative approach to the PK studies of volatile compounds in TCMs.

Acorus↗

Solid-phase microextraction (SPME) of permethrin residues from cucumber using a silica-bonded phase-coated stainless steel fibre.

Solid-phase microextraction (SPME) is a rapid, economic and solvent-free sample preparation method for the isolation of an analyte from its matrix. The technique uses a few centimetres of some adsorptive materials such as activated charcoal, polydimethylsiloxane or octadecyl silane coated onto fused silica optical fibres or, more recently, stainless steel fibres mounted into a microsyringe. The proposed method allows the extraction of permethrin from cucumber matrix into the coating, avoiding sample handling and saving evaporation of solvents and concentration steps. Adsorbed permethrin was desorbed in the split/splitless injection port of the gas chromatograph. The time required for each run was about 1.5 h, which gave a preconcentration of several orders of magnitude. The method could separate and quantify cis- and trans-isomers of permethrin. The calibration curve showed linearity in the range 1-9 micrograms ml-1, with detection limits of 0.03 and 0.05 microgram ml-1 for the cis- and trans-isomers of permethrin, respectively. The method had a recovery rate of about 70% and a relative standard deviation of less than 13%. Results suggest that this procedure provides a rapid and sensitive alternative method to those currently available.

Adsorption↗

Dodecylsulfate-doped polypyrrole film prepared by electrochemical fiber coating technique for headspace solid-phase microextraction of polycyclic aromatic hydrocarbons.

The electrochemical fiber coating (EFC) technique was used for the preparation of dodecylsulfate-doped polypyrrole (PPy-DS), and applied as a new fiber for solid-phase microextraction (SPME) procedures. PPy-DS film was directly electrodeposited on the surface of a platinum wire from an aqueous solution containing pyrrole and sodium dodecylsulfate, using cyclic voltammetry (CV). The effect of polymerization conditions and type of dopants on the thermal stability, adhesion and extraction characteristics of the fiber were investigated. The electron microscopy imaging of PPy-DS film suggested that the surface fiber coating was well-distributed with a porous structure. The fiber coating can be prepared easily in a reproducible manner, and it is inexpensive and has a stable performance at high temperatures (up to the 300 degrees C). The extraction properties of the fiber to eight polycyclic aromatic hydrocarbons (PAHs) were examined, using a headspace-SPME (HS-SPME) device coupled with gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The results revealed study shows that PPy-DS as a SPME fiber coating is suitable for the successful extraction of PAHs. The effects of the extraction parameters including exposure time, sampling temperature, salt concentration, and stirring rate on the extraction efficiency have been studied. A satisfactory reproducibility for extractions from spiked water samples at PPb-level with R.S.D. < 7.6% (n = 7) was obtained. The calibration graphs were linear in the range of 0.5-100ng ml(-1) and detection limits for the selected PAHs were between 0.05-0.16 ng ml(-1). Comparing the HS-SPME results for extraction and determination of PAHs using PPy-DS fiber with the corresponding literature data using PDMS fiber shows that the proposed fiber has a better detection limit for low molecular weight PAHs. The life span and stability of PPy-DS fiber is good and it can be used more than 50 times at 250 degrees C without any significant change in sorption properties.

Electrochemistry↗

Method optimization by solid-phase microextraction in combination with gas chromatography with mass spectrometry for analysis of beer volatile fraction.

A simple and sensitive method for the analysis of beer volatile compounds was optimised using headspace solid-phase microextraction (SPME) and gas chromatography with mass detection. Headspace SPME using a 75 microm Carboxen-polydimethylsiloxane (CAR-PDMS) fiber provided effective sample enrichment and enabled extraction of a wide variety of compounds. The reproducibility depended on the compounds, with a mean value of 1.4% for alcohols, 3.3% for ethers, 6.7% for aldehydes, 3.4% for acids, 1.7% for aromatic compounds, 2.4% for esters, 7.4% for hydrocarbons, 1.8% for alicyclic compounds, and 3.4% for heterocyclic compounds. The optimised methodology can be used to compare volatile profile from different types of beers and eventually to study the evolution of a particular beer during aging.

Beer↗