PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “systems drift”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Pattern formation in directional solidification under shear flow. I. Linear stability analysis and basic patterns.

An asymptotic interface equation for directional solidification near the absolute stability limit is extended by a nonlocal term describing a shear flow parallel to the interface. In the long-wave limit considered, the flow acts destabilizing on a planar interface. Moreover, linear stability analysis suggests that the morphology diagram is modified by the flow near onset of the Mullins-Sekerka instability. Via numerical analysis, the bifurcation structure of the system is shown to change. Besides the known hexagonal cells, structures consisting of stripes arise. Due to its symmetry-breaking properties, the flow term induces a lateral drift of the whole pattern, once the instability has become active. The drift velocity is measured numerically and described analytically in the framework of a linear analysis. At large flow strength, the linear description breaks down, which is accompanied by a transition to flow-dominated morphologies which is described in the following paper. Small and intermediate flows lead to increased order in the lattice structure of the pattern, facilitating the elimination of defects. Locally oscillating structures appear closer to the instability threshold with flow than without.

Journal Article↗

Lesions of the posterior commissure disable the vertical neural integrator of the primate oculomotor system.

1. Spontaneous saccades, vestibuloocular responses (VOR), and optokinetic nystagmus were recorded in three squirrel monkeys before and after chemical or electrolytic lesion of the posterior commissure (PC). 2. PC lesions produced abnormal vertical eye movements, in particular, 1) Postsaccadic drifts, and 2) VOR gain reduction and phase advance more pronounced at lower frequencies of sinusoidal head rotation. Horizontal eye movements were much less affected (or normal). 3. We conclude that PC fibers are necessary for conveying the output of the vertical neural integrator to vertical oculomotor-neurons.

Abducens Nerve↗

A precision isotonic measuring system for isolated tissues.

An isotonic measuring system is described which utilizes an angular position transducer of the linear differential voltage transformer type. Resistance to corrosion, protection against the ingress of solutions, and ease of mounting and setting up were the mechanical objectives. Accuracy, linearity, and freedom from drift were essential requirements of the electrical specification. A special housing was designed to accommodate the transducer to overcome these problems. A control unit incorporating a power supply and electronic filtering components was made to serve up to four such transducers. The transducer output voltage is sufficiently high to drive directly even low sensitivity chart recorders. Constructional details and a circuit diagram are included. Fifty such transducers have been in use for up to four years in these laboratories. Examples of some of the published work done using this transducer system are referenced.

Animals↗

Dynamics of a faceted nematic-smectic-B front in thin-sample directional solidification.

We present an experimental study of the directional-solidification patterns of a nematic-smectic-B front. The chosen system is C4H9-(C6H10)2CN (in short, CCH4) in 12 microm-thick samples, and in the planar configuration (director parallel to the plane of the sample). The nematic-smectic-B interface presents a facet in one direction-the direction parallel to the smectic layers--and is otherwise rough and devoid of forbidden directions. We measure the Mullins-Sekerka instability threshold and establish the morphology diagram of the system as a function of the solidification rate V and the angle straight theta(0) between the facet and the isotherms. We focus on the phenomena occurring immediately above the instability threshold when straight theta(0) is neither very small nor close to 90 degrees. Under these conditions, we observe drifting shallow cells and a type of solitary wave, called "faceton," which consists essentially of an isolated macroscopic facet traveling laterally at such a velocity that its growth rate with respect to the liquid is small. Facetons may propagate either in a stationary or an oscillatory way. The detailed study of their dynamics casts light on the microscopic growth mechanisms of the facets in this system.

Journal Article↗

The karaite community of Iraq in Israel: a genetic study.

Ninety-eight of 136 (72%) individuals at least 6 years of age from a small isolate of the Karaite community, known to have lived in Iraq since the tenth century, were examined. In Iraq this group maintained a highly inbred existence but married Karaites from Egypt after their immigration to Israel in 1951. Observations of several unique gene frequencies for blood group and isoenzyme markers, not described among other Jewish groups, are explicable by isolation and genetic drift in a very small community.

ABO Blood-Group System↗

Molecular cloud origin for the oxygen isotope heterogeneity in the solar system.

Meteorites and their components have anomalous oxygen isotopic compositions characterized by large variations in 18O/16O and 17O/16O ratios. On the basis of recent observations of star-forming regions and models of accreting protoplanetary disks, we suggest that these variations may originate in a parent molecular cloud by ultraviolet photodissociation processes. Materials with anomalous isotopic compositions were then transported into the solar nebula by icy dust grains during the collapse of the cloud. The icy dust grains drifted toward the Sun in the disk, and their subsequent evaporation resulted in the 17O- and 18O-enrichment of the inner disk gas.

Carbon Isotopes↗

On thermal convection in slowly rotating systems.

The dynamical properties of convection patterns in a fluid layer heated from below and rotating slowly about a horizontal axis are reviewed. Applications to the equatorial regions of planetary and stellar atmospheres are emphasized. Attention is drawn to the wavelike drift of hexagonal convection cells in the azimuthal direction and to the mean flow generated by all convection patterns except for rolls aligned with the axis of rotation.

Journal Article↗

Hyperpronation control with a dynamic stabilizing innersole system.

An orthotic device, which prevents hyperpronation of a human foot, has an offset, deep heel seat to cup the calcaneus. It maintains the calcaneus in approximately 5 degrees of varus with high medial and lateral flanges, which prevents lateral transverse drift of the first and fifth metatarsals.

Calcaneus↗

Spatial and space-time correlations in systems of subpopulations with stochastic migration.

The great majority of models of the population genetics of subdivided populations have made the simplifying assumption that the gene frequencies in migrant groups are deterministic. The present paper examines models which more closely mimic natural conditions, in which the gene frequencies in migrant groups are subject to stochastic effects. It is shown that some types of stochastic migration can cause dramatic changes in spatial correlations and variance. These changes depend on how the stochastic migration effects in the gene frequency recursion equations are shared among nearby subpopulations during the same generation. Only for cases where the effects are completely unshared are the equilibrium spatial and space-time correlations among adult subpopulations unaffected, but the variance is always inflated. The analyses here use novel methods, by recasting population genetic migration-drift models as space-time autoregressive moving average (STARMA) processes. Recent theorems for STARMA processes are employed for finding the spatial correlations, and for the first time in population genetics theory the complete set of space-time correlations, for systems with general patterns of migration rates and numbers of spatial dimensions. The space-time correlations provide a uniquely detailed description of a system, and thus form a link between observed spatial autocorrelation statistics and the underlying space-time population genetic process. STARMA theoretical processes have direct statistical analogues that can be applied for process identification, parameter estimation, model fitting, and forecasting in real systems.

Animals↗

Abduction nystagmus in internuclear ophthalmoplegia.

We tested the hypothesis that abnormalities of the abducting eye in internuclear ophthalmoplegia reflect an adaptive process that helps overcome the adduction weakness of the opposite eye. This response operates under the constraints of Hering's law of equal innervation: any attempt to increase the innervation to a weak muscle in one eye must be accompanied by a commensurate increase in innervation to the yoke muscle in the other eye. In 4 patients with internuclear ophthalmoplegia, we patched one eye for 1 to 5 days to allow time for the central nervous system to optimize innervation for the habitually viewing eye. We predicted that there would be a conjugate adjustment of innervation that would diminish the abduction overshoot and backward postsaccadic drift made by the habitually viewing eye. This was the case in 3 of our 4 patients. Our findings show that the abduction nystagmus is a manifestation of a normal adaptive response in some patients with INO.

Adaptation, Physiological↗

Nanogold plasmon resonance-based glucose sensing. 2. Wavelength-ratiometric resonance light scattering.

Gold colloids are well known to display strong plasmon absorption bands due to electron oscillations induced by the incident light. When the colloids are in proximity, the plasmon absorption bands are often perturbed. This has enabled us recently to successfully develop a glucose sensing platform based on the disassociation of dextran-coated gold colloids, cross-linked with Con A, by glucose. However, a much more useful and simpler property of gold colloids, which has been ill explored with regard to sensing, is their ability to efficiently scatter excitation light. We have found that our nanogold sensing aggregates are indeed efficient light scatters around the nanogold plasmon absorption band. By measuring the ratio of scattered light intensities at two different arbitrary wavelengths, 560 and 680 nm, glucose concentrations can be readily determined from a few millimolar up to approximately 60 mM, using a simple white light LED and detection system. Further, by measuring the ratio of the scattered intensities, this sensing approach is independent of the total sensing aggregate concentration and the excitation and detection instrumentation fluctuations or drifts. This simplistic and low-cost approach to glucose sensing, coupled with the sensing aggreagates' ability to scatter red light, suggests the potential use of these aggregates for use in physiological transdermal glucose monitoring, either for implantable skin sensors or glucose sensing tattoos (discussed later).

Biosensing Techniques↗

Plasticity and tuning of the time course of analog persistent firing in a neural integrator.

In a companion paper, we reported that the goldfish oculomotor neural integrator could be trained to instability or leak by rotating the visual surround with a velocity proportional to +/- horizontal eye position, respectively. Here we analyze changes in the firing rate behavior of neurons in area I in the caudal brainstem, a central component of the oculomotor neural integrator. Persistent firing could be detuned to instability and leak, respectively, along with fixation behavior. Prolonged training could reduce the time constant of persistent firing of some cells by more than an order of magnitude, to <1 s. Normal visual feedback gradually retuned persistent firing of integrator neurons toward stability, along with fixation behavior. In animals with unstable fixations, approximately half of the eye position-related cells had upward or unstable firing rate drift. In animals with leaky fixations, two-thirds of the eye position-related cells showed leaky firing drift. The remaining eye position-related cells, generally those with lower eye position thresholds, showed a more complex pattern of history-dependent/predictive firing rate drift in relation to eye drift. These complex drift cells often showed a drop in maximum persistent firing rate after training to leak. Despite this diversity, firing drift and the degree of instability or leak in firing rates were broadly correlated with fixation performance. The presence, strength, and reversibility of this plasticity demonstrate that, in this system, visual feedback plays a vital role in gradually tuning the time course of persistent neural firing.

Animals↗

A computer controlled calibrator, spectrum overlap eraser and automatic sensitivity control for an anaesthetic mass spectrometer.

The operation, design and performance of a microcomputer controlled spectrum overlap eraser and automatic sensitivity control (ASC) for a clinical mass spectrometer are described allowing calibration for up to eight anaesthetic gases in less than 15 s per gas. The critical design parameters are identified and the mathematical algorithm used discussed. Constructional details of the system are given with particular reference to the key components identified in the analysis of design parameters. The results of static and dynamic testing of the system are reported. The calibrator showed output linearities within +/- 1.7% first standard deviation (FSD) for a two part mixture of gases relevant in anaesthesia and a typical accuracy of 2.1% FSD for any point. Dynamic testing showed that the machine did not impede the overall speed of response of the system. Transient viscosity effects were adequately eliminated and ASC action effective for variation in source pressure between 11.3 X 10(-3) Pa and 2.7 X 10(-4) Pa. Mean drift with the calibrator was found to be less than 0.38% vol/vol h-1.

Anesthesiology↗

Motion processing using asymmetric shunting lateral inhibitory networks.

Asymmetrically connected inhibitory shunting networks are believed to occur in many areas of the brain, including the visual system; they can explain many peripheral visual phenomena. This paper illustrates their usefulness in motion detection, and compares details of their performance with experimental results. Two stimuli are considered: drifting gratings and jumping bars. An elementary motion detector (EMD) is defined, consisting of a pair of opposite-directed asymmetric inhibitory networks. A frequency-space expansion (equivalent to a Volterra-Wiener expansion) is used to examine the EMD's response to a drifting grating. The EMD can be tuned to independent spatial and temporal frequencies: by summing the outputs of a number of EMDs, a velocity-tuned network is obtained. This velocity-tuned network is very well suited to certain field effect transistor (FET) implementations. Since the network is nonlinear, the response to a drifting grating does not fully characterize its behaviour. The response to a jumping bar stimulus is also examined. Two animals are considered: *Cats: the work of Emerson et al on the response of directionally selective (DS) complex cells in cat visual cortex to a white noise signal. *Flies: the work of Franceschini et al on the response of the fly H1 cell to stimulation of two neighbouring receptor cells, and that of Horridge and Marcelja on the fly H1 response to various jumping bar and edge stimuli. Agreement with all three of these experiments cannot be expected, because the results for the two animals are not consistent. There are two main differences: *Time development of the velocity-tuned signal: for the fly H1 cell this generally consists of two sharp (ON and OFF) responses to the second presentation of the bar signal, while for the cat DS cell a more slowly varying signal is observed. *Response to two presentations of the bar signal in the same position (i.e., a 'jumping bar' that jumps zero distance): for the fly H1 cell there is generally no response, while the cat DS cell responds significantly. The velocity-tuned network agrees well with the results for the cat DS cells.

Journal Article↗

Geometry of river networks. I. Scaling, fluctuations, and deviations.

This paper is the first in a series of three papers investigating the detailed geometry of river networks. Branching networks are a universal structure employed in the distribution and collection of material. Large-scale river networks mark an important class of two-dimensional branching networks, being not only of intrinsic interest but also a pervasive natural phenomenon. In the description of river network structure, scaling laws are uniformly observed. Reported values of scaling exponents vary, suggesting that no unique set of scaling exponents exists. To improve this current understanding of scaling in river networks and to provide a fuller description of branching network structure, here we report a theoretical and empirical study of fluctuations about and deviations from scaling. We examine data for continent-scale river networks such as the Mississippi and the Amazon and draw inspiration from a simple model of directed, random networks. We center our investigations on the scaling of the length of a subbasin's dominant stream with its area, a characterization of basin shape known as Hack's law. We generalize this relationship to a joint probability density, and provide observations and explanations of deviations from scaling. We show that fluctuations about scaling are substantial, and grow with system size. We find strong deviations from scaling at small scales which can be explained by the existence of a linear network structure. At intermediate scales, we find slow drifts in exponent values, indicating that scaling is only approximately obeyed and that universality remains indeterminate. At large scales, we observe a breakdown in scaling due to decreasing sample space and correlations with overall basin shape. The extent of approximate scaling is significantly restricted by these deviations, and will not be improved by increases in network resolution.

Ecosystem↗

Impact of rater knowledge on sexually abused and nonabused girls' scores on the Draw-A-Person: Screening Procedure for Emotional Disturbance (DAP:SPED).

Human figure drawings collected from a clinical sample of 20 sexually abused and 20 nonsexually abused girls were randomly assigned to 1 of 2 case descriptions: Actual, in which raters were told the girls' actual abuse status, or Pretend, in which raters were told that drawings were made by girls with the opposite abuse status. Using the Draw-A-Person: Screening Procedure for Emotional Disturbance (DAP:SPED) scoring system developed by Naglieri, McNeish, and Bardos (1991), three raters independently scored 44 randomly ordered protocols, 4 of which were commonly rated as checks for rater accuracy and observer drift. Results revealed no significant effect for girls' abuse status or the case description given to raters, thereby suggesting that the DAP:SPED is sufficiently objective to withstand the confounding influence of varying case descriptions.

Adolescent↗

Causes of unsatisfactory performance in proficiency testing.

BACKGROUND: Proficiency testing (PT) provides a measure of the effectiveness of laboratory quality assurance programs. Test reports are released from processes that the laboratory judges to be in conformance with quality specifications; an evaluation of unsatisfactory performance (UNSAT) by a PT provider is an unexpected outcome for the laboratory. An understanding of the root cause(s) of testing errors provides an opportunity for the continuous improvement of laboratory services. METHODS: We used participant data from the New York State Department of Health PT program to characterize the quality of testing in the toxicology specialty. Outcomes from laboratory investigations into causes of UNSAT and information on quality control practices collected from all program participants were used to identify the root causes of error. RESULTS: Two classes of error were encountered: spurious test results caused by lapses in standard operating procedures and instrument malfunctions (300 per million assays) and common-cause analytic error (7000 per million assays or 0.7% rate of UNSAT). Causes of spurious results included inaccurate mathematical correction for specimen dilution, misinterpretation of instrument codes, and instrument sampling errors. Calibration drift was most frequently cited as the common-cause analytic error. Approximately one-half of the laboratories used an allowable error for the quality control of analytical systems that exceeded the threshold error specified by manufacturers for stable instrument performance. CONCLUSIONS: The causes of spurious results suggest the need for ongoing competency testing of analysts where analyst intervention is required in an otherwise automated process, and for continued diligence in mistake-proofing instrument design. The intrinsic quality of laboratory testing is unlikely to improve until the allowable error in quality control is consistent with manufacturer specifications for stable system performance.

Clinical Chemistry Tests↗