PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Linear Energy Transfer”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors.

The laboratory of Microbiology at SCK.CEN, in collaboration with different universities, participates in several ESA programmes with bacterial experiments that are carried out in the International Space Station (ISS). The main objective of these programmes is to study the effects of space flight conditions such as microgravity and cosmic radiation on the general behaviour of model bacteria. To measure the radiation doses received by the bacteria, different detectors accompanied the microbiological experiments. The results obtained during two space flight missions are discussed. This dosimetry experiment was a collaboration between different institutes so that the doses could be estimated by different techniques. For measurement of the high linear energy transfer (LET) doses (>10 keV microm(-1)), two types of etched track detectors were used. The low LET part of the spectrum was measured by three types of thermoluminescent detectors ((7)LiF:Mg,Ti; (7)LiF:Mg,Cu,P; Al(2)O(3):C) and by the optically stimulated luminescence technique using Al(2)O(3):C detectors.

Cosmic Radiation↗

Novel shielding materials for space and air travel.

The reduction of dose onboard spacecraft and aircraft by appropriate shielding measures plays an essential role in the future development of space exploration and air travel. The design of novel shielding strategies and materials may involve hydrogenous composites, as it is well known that liquid hydrogen is most effective in attenuating charged particle radiation. As precursor for a later flight experiment, the shielding properties of newly developed hydrogen-rich polymers and rare earth-doped high-density rubber were tested in various ground-based neutron and heavy ion fields and compared with aluminium and polyethylene as reference materials. Absorbed dose, average linear energy transfer and gamma-equivalent neutron absorbed dose were determined by means of LiF:Mg,Ti thermoluminescence dosemeters and CR-39 plastic nuclear track detectors. First results for samples of equal aerial density indicate that selected hydrogen-rich plastics and rare-earth-doped rubber may be more effective in attenuating cosmic rays by up to 10% compared with conventional aluminium shielding. The appropriate adaptation of shielding thicknesses may thus allow reducing the biologically relevant dose. Owing to the lower density of the plastic composites, mass savings shall result in a significant reduction of launch costs. The experiment was flown as part of the European Space Agency's Biopan-5 mission in May 2005.

Aircraft↗

Detection of primary and secondary cosmic ray particles aboard the ISS using SSNTD stacks.

To study the radiation environment inside the International Space Station, solid state nuclear track detector stacks were used. Within the BRADOS experiments, Phase 1, seven stacks were exposed at different locations of the Russian segment 'Zvezda' for 248 days in 2001. It was supposed that the radiation field inside the ISS was composed from primary cosmic ray particles penetrating the wall of the ISS and secondaries, mainly neutrons induced by primaries in the wall and other structural materials surrounding the detectors. Based on the calibration made by utilising the high energy neutron reference field CERF at CERN (Geneva, Switzerland), the tracks induced by neutrons were separated from those induced by primary particles. Thus, the stacks, on one hand, provided the secondary neutron ambient dose equivalent. On the other hand, from the analysis of the rest of the tracks, the linear energy transfer spectra were computed and the flux and the dose of the primary particles were determined as shown in this paper.

Cosmic Radiation↗

Past and future application of solid-state detectors in manned spaceflight.

The radiation exposure in space missions can be reduced by careful mission planning and appropriate measures, such as provision of a radiation shelter, but it cannot be eliminated. The reason for that is the high penetration capability of the radiation components owing to their high energies. Radiation is therefore an acknowledged primary concern for manned spaceflight and is a potentially limiting factor for long-term orbital and interplanetary missions. The radiation environment is a complex mixture of charged particles of solar and galactic origin and of the radiation belts, as well as of secondary particles produced in interactions of the galactic cosmic particles with the nuclei of atmosphere of the earth. The complexity even increases by placing a spacecraft into this environment owing to the interaction of the radiation components with the shielding material. Therefore it is a challenge to provide for appropriate measurements in this radiation field, coping with the limited resources on experiment power and mass. Solid-state dosemeters were already chosen for measurements in the first manned flights. Thermoluminescence dosemeters (TLDs) and plastic nuclear track detectors (PNTD) especially found a preferred application because they are light-weighted, need no power supply and they are tissue-equivalent. Most of the data available until 1996 were gathered by using these passive detectors; this especially holds for heavy ion particle spectra. The systems, supplemented by converter foils or fission detectors and bubble detectors, provide information on dose, particle flux-, energy- and linear energy transfer spectra of the ionising radiation and neutron fluxes and doses. From 1989, silicon detectors were used for dose and flux measurements and later on for particle spectrometry. Silicon detectors were demonstrated as a powerful tool for the description of space radiation environment. Optical simulated luminescence (OSL) detectors have now been introduced as a new system in space research. Both, OSL and superheated drop detectors are candidates for personal dosimetry systems. The article will summarise past results, and results of measurements performed recently on the ISS, and conclude with future aspects.

Cosmic Radiation↗

Beam characterisation of the KIRAMS electron microbeam system.

An electron microbeam system has been installed at the Korea Institute of Radiological and Medical Sciences (KIRAMS) for use in radiation biology studies. The electron beam is produced from a commercial electron gun, and the beam size is defined by a 5 microm diameter pinhole. Beam energy can be varied in the range of 1-100 keV, covering a range of linear energy transfer from 0.4 to 12.1 keV microm-1. The micrometer-sized electron beam selectively irradiates cells cultured in a Mylar-bottomed dish. The positioning of target cells one by one onto the beam exit is automated, as is beam shooting. The electron beam entering the target cells has been calibrated using a Passivated Implanted Planar Silicon (PIPS) detector. This paper describes the KIRAMS microbeam cell irradiation system and its beam characteristics.

Electrons↗

Single-ion dosemeter based on floating gate memories.

Floating Gate (FG) nonvolatile memories are based on a tiny polysilicon layer (the FG) which can be permanently charged with electrons or holes, thus changing the threshold voltage of a MOSFET. Every time a FG is hit by a high energy ion, it experiences a charge loss, depending on the ion linear energy transfer (LET) and on the transistor geometrical and electrical characteristics. This paper discusses the opportunities to use this devices as single an ion dosemeter with sub-micrometer spatial resolution and capable of distinguish the impinging ion LET.

Computer Storage Devices↗

Nanodosimetry, the metrological tool for connecting radiation physics with radiation biology.

It is generally accepted that the early damage to genes or cells by ionising radiation starts with the early damage to segments of the DNA, at least, to the greater part. This damage is the result of the spatial distribution of inelastic interactions of single ionising particles within the DNA or in its neighbourhood and is, in consequence, determined by the stochastics of particle interactions in volumes a few nanometre in size. Due to the latter fact radiation damage strongly depends on radiation quality and cannot be described satisfactorily in detail by macroscopic quantities like absorbed dose or linear energy transfer (LET). It can, however, be described approximately by the probability distribution of ionisation cluster-size formation in nanometric target volumes of liquid water (nanodosimetry). One aim of nanodosimetry is, therefore, to measure the radiation induced frequency distribution of ionisation cluster-size formation in liquid water, as a substitute for sub-cellular material, in volumes which are comparable in size with those of the most probable radio-sensitive volumes of biological systems. After a short description of the main aspects of cluster-size formation by ionising particles, an overview is given about the measuring principles applied in present-day nanodosimetric measurements. Afterwards, physical principles are discussed which can be used to convert ionisation cluster-size distributions measured in gases into those caused by ionising radiation in liquid water. In a final section, the probability distribution of ionisation cluster-size formation in liquid water is discussed from the point of view of damage formation to segments of the DNA.

Biopolymers↗

Radiation burdens for humans on prolonged exomagnetospheric voyages.

The severity of radiation exposure for astronauts outside the magnetosphere poses a critical unanswered question bearing on the use of manned vehicles in extended exploration of the solar system (moon, Mars). Such prolonged exomagnetospheric voyages (1-3 years) enter a radiologic environment more severe than that of low earth orbit, an annual dose equivalent in the range of 0.3-0.5 Sv (30-50 rem), and a lifetime excess cancer fatality risk of 3-5% due to low linear-energy-transfer components of galactic cosmic radiation alone. To this calculus must be added estimates for high-atomic-number, high-energy particles, the probability of solar particle events, and the limited effectiveness of shielding. For a 3-year Mars voyage these could elevate the dose equivalent to 1.5-2.25 Sv (150-225 rem) total (0.5-0.75 Sv [50-75 rem] annual) and risks to 5-9% excess cancer fatality. Both the mission (civilian scientific research) and the alternatives (unmanned robotic devices) enter the policy decision here. This paper presents a brief review of pertinent physical and biological data and of research urgently needed before reaching a decision on this question.

Body Burden↗

Fast neutron radiation for inoperable and recurrent salivary gland cancers.

The current standard treatment of salivary gland cancers consists of surgical resection, with or without postoperative low linear energy transfer (LET) radiation, resulting in high locoregional control rates. However, tumor control prognosis is poor when conventional radiation is used alone for advanced, inoperable cases. An extensive review of the world's literature on fast neutron irradiation for inoperable, unresectable, or recurrent malignant salivary gland neoplasms is presented and compared with the experience using conventional low LET radiotherapy. The pooled data indicate a locoregional control rate of 67% for fast neutrons versus 25% for photons and/or electrons in the treatment of such advanced disease. The radiobiological rationale supporting this observed increase in tumor control is discussed. The overall significant late complication rate is 19%, but several suboptimal treatment factors were present that contributed substantially to the reported toxicity. With the modern machines and treatment techniques now available, the evidence overwhelmingly supports the role of fast neutron radiation as the treatment of choice for inoperable and recurrent salivary gland cancers.

Energy Transfer↗

Fast neutron radiotherapy for sarcomas of soft tissue, bone, and cartilage.

The basic radiobiological rationale for the use of fast neutron radiotherapy in the treatment of classically radioresistant tumors such as soft tissue sarcomas, osteogenic sarcomas, and chondrosarcomas is reviewed. There are no definitive randomized studies comparing high and low linear energy transfer radiotherapy for these tumor systems, but a review of published series is highly suggestive of a therapeutic advantage for fast neutrons. For soft tissue sarcomas, the local control rate is 53% (158 of 297) with fast neutrons, compared with 38% (49 of 128) with photons/electrons; for osteogenic sarcomas, the local control rate is 55% (40 of 73) with fast neutrons, compared with 21% (15 of 73) with photons/electrons; and for chondrosarcomas, the local control rate is 49% (25 of 51) with fast neutrons, compared with 33% (10 of 30) with photons/electrons. An ongoing clinical trial for these tumors is also described.

Bone Neoplasms↗

A Monte Carlo primer for health physicists.

The basic ideas and principles of Monte Carlo calculations are presented in the form of a "primer" for health physicists. A simple integral with a known answer is evaluated by two different Monte Carlo approaches. Random numbers, which underlie Monte Carlo work, are discussed, and a sample table of random numbers generated by a hand calculator is presented. Monte Carlo calculations of dose and linear energy transfer (LET) from 100-keV neutrons incident on a tissue slab are discussed. The random-number table is used in a hand calculation of the initial sequence of events for a 100-keV neutron entering the slab. Some pitfalls in Monte Carlo work are described. While this primer addresses mainly the "bare bones" of Monte Carlo, a final section briefly describes some of the more sophisticated techniques used in practice to reduce variance and computing time.

Health Physics↗

The next decade in external dosimetry.

In recent years, a number of external dosimetry problems have been solved. However, changes in standards and legal concepts relating to the application of dosimetry results will require further enhancements in measurement techniques and philosophy in the next 10 y. The introduction of effective dose equivalent and the legal use of probability of causation will require that much greater attention be given to determination of weighted organ dose from external exposure. An imminent change--an increase in the fast neutron quality factor--will require a new round of technology development in a field that has just received a decade of close scrutiny. For the future, we must take advantage of developments in microelectronics. The use of random access memory (RAM) and metal-on-silicon (MOS) devices as detector elements, particularly for neutron dosimetry, has exciting possibilities that are just beginning to be explored. Advances in microcircuitry are leading, and will continue to lead, in the development of a new generation of small, rugged and "smart" radiation survey instruments that will make the most of detector data. It has become possible with very compact instruments to obtain energy spectra, linear-energy-transfer (LET) spectra, and quality factors in addition to the usual integrated dosimetric quantities: exposure, absorbed dose, and dose equivalent. These instruments will be reliable and easy to use. The user will be able to select the level of sophistication that is required for any specific application. Moreover, since the processing algorithms can be changed, changes in conversion factors can be accommodated with relative ease. During the next decade, the use of computers will continue to grow in value to the health physicist. Personal computers and codes designed for dosimetry applications will become prominent, providing the health physicist with the ability to perform sophisticated data reduction, spectra unfolding and even radiation modeling and transport calculations on the desk top. In the far term, the use of computers could extend to the development of sophisticated tracking systems that would follow and record the workers' movements throughout a radiation area. These data, together with information from area monitors, air samplers and personnel dosimeters, could be used to develop truly integrated dose estimates, including reconstruction of organ doses.

Beta Particles↗

Spatial and temporal distribution of energy.

Studies of the spatial and temporal distribution of microscopic radiation doses lead to potentially important questions regarding conventional approaches to radiation protection. The short ranges of alpha-particle and Auger-electron emissions from radionuclides lead to uncertainties in assessing their hazards. The conventional extrapolations from intermediate doses to low doses and dose rates are questioned by observed dose-rate effects in the so-called "initial slope," by the total lack of data for single tracks in cells and by the possibility of multiple-cell effects. At all subcellular levels, even down to DNA, high linear-energy-transfer (LET) radiations can produce unique initial damage, different from that possible with low-LET radiations, and therefore may even, in principle, produce unique final biological effects. This questions simple extrapolations from low- to high-LET radiations and the application of universal quality factors to diverse effects. Further understanding of these questions could lead, in future, to substantial increases or decreases in estimations of risk.

Alpha Particles↗

Quality factors.

The quality factor, Q, is a dimensionless modifier used in converting absorbed dose, expressed in gray (or rad), to dose equivalent, expressed in sievert (or rem). The dose equivalent is used in radiation protection to account for the biological effectiveness of different kinds of radiation. The quality factor is related to both linear energy transfer (LET) and relative biological effectiveness (RBE). The RBE obtained from biological experiments depends in a complex way on the observed biological effect, the specific test organism and the experimental conditions. Judgment is involved, therefore, in the choice of Q. Questions regarding the adequacy of current Q values for neutrons were first raised in a 1980 statement by the National Council on Radiation Protection and Measurements (NCRP) and later in a 1985 statement by the International Commission on Radiological Protection (ICRP). In 1980, the NCRP alerted the technical community to the possibility of a future increase between a factor of 3 to 10 in the Q for neutrons, and in 1985, the ICRP suggested an increase by a factor of 2 in Q for fast neutrons. Both these advisory groups are now recommending essentially the same guidance with regard to Q for neutrons: an increase by a factor of 2. The Q for neutrons is based on a large, albeit unfocused, body of experimental data. In spite of the lack of focus, the data supporting a change in the neutron quality factor are substantial. However, the proposed doubling of Q for neutrons is clouded by other issues regarding its application. These issues are discussed, together with the current database for the neutron quality factor. Improvements are needed to provide better guidance with regard to both Q for neutrons and its application in radiation protection.

Animals↗

Microdosimetric basis for exposure limits.

Consideration of the energy deposited by ionizing radiation in microscopic volumes has led to new insights into dosimetric concepts at the levels of interest in radiation protection. Large amounts of energy are deposited by the passage of low linear-energy-transfer (LET)-charged particles through small volumes. If a typical cell nucleus is considered to be about 7 micron, at an exposure rate of 2.5 X 10(-1) C kg-1 h-1 (1 mR hr-1) from a 60Co irradiation, the average cell nucleus receives one energy deposition event every 12.5 d. Biological processes, which modify radiation damage, typically occur in a few minutes to a few hours. Thus, at occupational exposure levels it is probably the irreparable or misrepaired effects of irradiation that determine the biological consequences. One goal of dosimetry is to measure the incident radiation, making it possible to predict biological risk and set meaningful exposure limits. These measurements must relate to the energy depositions that are responsible for radiation effects at low dose rates, yet the dosimetry system must not be excessively complex to allow use by operational health physicists. Furthermore, our description of the irradiation should be directly measurable. The use of quality factors based upon the energy deposition in a 1-micron-diameter volume of tissue as prescribed in International Commission on Radiation Units Report No. 40 (Joint Task Group 1986) satisfies these requirements. Instrumentation based upon measurement of lineal energy has already been successfully used in health-physics applications. Future changes in the quality factor can be accommodated by changing the algorithm in these microprocessor-based instruments.

Dose-Response Relationship, Radiation↗

Modeling the biological effectiveness of high-LET radiation.

Reevaluation of neutron exposures to atomic bomb survivors has greatly reduced the significance of that data base for estimating the relative biological effectiveness of radiations with high linear energy transfer (LET). Consequently, greater emphasis is being given to animal data and mechanistic studies at the cellular and molecular level in assessing the role of radiation quality in the health effects of low-level radiation exposure. We are investigating the spatial patterns of energy deposited in DNA by ionizing radiation and their influence on cell killing and mutation induction. Our basic hypothesis is that high ionization density increases the probability that radiation-induced DNA damage will be unrepairable or misrepaired. This paper discusses the use of computer simulation to investigate damage induced in DNA by the decay of incorporated 125I.

Computer Simulation↗

RBE vs. dose for low doses of high-let radiations.

According to track theory, the relative biological effectiveness (RBE) of high linear energy transfer (LET) radiations varies with cellular radiosensitivity parameters and the radiation environment. Of special interest is that the RBE varies as the dose of high-LET radiation to the power (1/m - 1) where m is the "target number" parameter, which varies from 2-4 in different cell lines. This applies to neutrons as well as to heavy ions at sufficiently low doses such that cells are not activated in the gamma-kill mode; that is, the tracks of single heavy ions are sufficiently far apart so that there are few cases of inter-track inactivation.

Cell Survival↗