PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Radiographic Image Interpretation, Computer-Assisted”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Comparison of a PACS workstation with conventional film for interpretation of neonatal examinations: a paired comparison study.

The diagnostic value of neonatal examinations using picture archiving and communication systems (PACS) was compared with that of conventional radiographs. A total of 202 consecutive chest or abdominal radiographs from the newborn intensive care unit were digitized for display on a commercially available PACS console. Experimental design was a paired comparison study. Plain films and PACS images were reviewed alternately in unbiased fashion. After the examination was evaluated using the second modality, any change in diagnosis or confidence in diagnosis was noted. Overall evaluation showed slight preference for the PACS modality. Change of diagnosis or in confidence of diagnosis was more than twice as likely to occur with evaluation of PACS (35%) after hardcopy than with evaluation of conventional radiographs (14%) after PACS. Of the variety of image processing features available on PACS, only window and leveling were judged to be of significant value. These results indicate that PACS and conventional radiographs of the neonatal chest and abdomen are of similar diagnostic value.

Humans↗

Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method.

The aim of this study was to compare the quality of reduction and the position of the fixating screws with the rate of union in 72 femoral neck fractures. The degree of fracture displacement after reduction and the position of the two fixating screws were determined with a new computerized measuring method that compensates for the variations in hip rotation in routine radiographs. All 13 nondisplaced fractures united. Sixteen of 18 fractures healed in the group of displaced fractures where both the fixating screws were placed within 3 mm from the femoral neck cortex, compared with 13 of 22 healed fractures in the group where only one screw had the same close contact with the femoral neck cortex (p < 0.05). Nonunion developed in all five displaced fractures where none of the two fixating screws were placed within 3 mm from the femoral neck cortex. The quality of reduction did not affect the healing rate; however, the number of poorly reduced fractures was only 10%. The results of this study underline the importance of achieving cortical support for the fixating screws in femoral neck fracture surgery.

Aged↗

Image processing in digital chest radiography: effect on diagnostic efficacy.

The usefulness of digital image processing of chest radiographs was evaluated in a clinical study. In 54 patients, chest radiographs in the posteroanterior projection were obtained by both 14 inch digital image intensifier equipment and the conventional screen-film technique. The digital radiographs (512 x 512 image format) viewed on a 625 line monitor were processed in three different ways: (1) standard display; (2) digital edge enhancement for the standard display; and (3) inverse intensity display. The radiographs were interpreted independently by three radiologists. The diagnoses were confirmed by CT, follow-up radiographs and clinical records. Chest abnormalities of the films analyzed included 21 primary lung tumors, 44 pulmonary nodules, 16 cases with mediastinal disease and 17 cases with pneumonia/atelectasis. Interstitial lung disease, pleural plaques, and pulmonary emphysema were found in 30, 18 and 19 cases, respectively. The sensitivity of conventional radiography when averaged overall findings was better than that of the digital techniques (P less than 0.001). The differences in diagnostic accuracy measured by sensitivity and specificity between the three digital display modes were small. Standard image display showed better sensitivity for pulmonary nodules (0.74 vs 0.66; P less than 0.05) but poorer specificity for pulmonary emphysema (0.85 vs. 0.93; P less than 0.05) compared with inverse intensity display. We conclude that when using 512 x 512 image format, the routine use of digital edge enhancement and tone reversal at digital chest radiographs is not warranted.

Adolescent↗

The effect of image processing on chest radiograph interpretations in a PACS environment.

The question of whether image processing affects a radiologist's diagnostic performance is becoming more important as the digital modalities proliferate. In the multi-observer study reported, the performance of radiologists who interpret a series of posteroanterior digitized chest images displayed on a high-resolution workstation, with and without a set of image processing options, is determined. These include brightness, contrast, reverse look-up tables (black-bone), and two edge enhancement options. Three hundred images were evaluated twice (once in each mode) by each of seven board-certified radiologists, who recorded their confidence ratings for the presence or absence of one or more of the following abnormalities: interstitial disease, nodule, and pneumothorax. The original, unprocessed digital image was available for reference for those sessions in which the processing options were available. With the exception of one reader, receiver operating characteristic (ROC) analysis showed no statistically significant difference between the two modes (with and without processing) for the detection of any of the different abnormalities by individual readers. Likewise, the group as a whole showed no significant difference (P less than .05) for detection of any of the three abnormalities between the two reading modes.

Hospital Information Systems↗

[Analysis of migration of screwed acetabular components following revision arthroplasty of the hip joint. Results of single-image roentgen analysis].

Out of 57 revised acetabular components, which were regularly checked, 47 had been replaced by a cemented Müller's acetabular reinforcement ring resp. a cementless Müller's Sl-shell with flange. Both types of cups are anchored in the acetabular roof with cancellous bone screws (tab. 1). 42 cases with radiograph series permitted a detailed analysis with the EBRA-method, a computer aided method for the evaluation of acetabular spatial migration based on standard radiographs of the pelvis. The clinical results were very satisfying (tab. 6). The screwed acetabular components migrated little, although, some essential displacements of the center of rotation (in relation to the anatomical position) had to be accepted. As was recognizable with today's inaccurate methods of measuring the center of the head, the displacement too far towards cranial influenced the migration tendency less than an excessive lateralisation. Especially satisfying is the fact, that no increased migration was observed after reconstruction bone grafting of severe acetabular defects, provided that at least a partly direct contact between the acetabular component and the original bone stock was obtained. For the first time EBRA shall be introduced here as a method which shows the migration and the spatial inclination of the acetabular cup in a vector chart.

Acetabulum↗

Semiquantitative and visual analysis of FDG-PET images in pulmonary abnormalities.

UNLABELLED: FDG PET images of the thorax can be analyzed semiquantitatively using standardized uptake ratios (SUR) or activity ratios between abnormal and normal tissue, or qualitatively by visual comparison of the abnormality to normal structures. Standardized uptake ratio evaluation of FDG PET images has been shown to accurately differentiate benign from malignant focal pulmonary abnormalities. The accuracy of activity ratios and visual analysis have not been evaluated. We therefore prospectively analyzed FDG PET images in patients with pulmonary abnormalities to evaluate differences in analytic schemes. METHODS: We evaluated 107 patients with an indeterminate focal abnormality on chest radiograph or CT with FDG PET between November 1991 and March 1993. The PET studies were evaluated using SUR, activity ratios and visual analysis. Activity ratios of maximum activity/cc and average activity/cc between regions of interest (ROIs) in abnormalities and normal lung on the contralateral side were calculated. Visual interpretations were graded on a five-point scale of two observers' confidence of malignancy. FDG uptake in the abnormality was also visually graded in comparison to mediastinal activity. Receiver-operating characteristic (ROC) curve areas were generated for the SUR data, activity ratios and visual analysis. RESULTS: Of 88 patients in which a conclusive diagnosis was made, 61 (69%) patients had malignancy and 27 (31%) patients had a benign process. SUR, maximum activity ratio, average activity ratio and visual interpretation ROC curve areas were 0.96, 0.95, 0.92 and 0.96, respectively. CONCLUSIONS: SUR, activity ratios and visual evaluation are each equally accurate methods of FDG PET data analysis in differentiating malignant from benign focal pulmonary abnormalities.

Deoxyglucose↗

Early diagnosis of spinal tuberculosis by MRI.

MRI was performed at three centres in Bombay on 24 patients clinically suspected of tuberculosis of the spine but with normal radiographs. There were 11 males and 13 females and their average age was 24 years (11 to 60). 99mTc bone scans were done in 16 patients before MRI. Eleven patients had the diagnosis confirmed by biopsy and the remainder all responded rapidly to specific antituberculous chemotherapy. On T1-weighted images there was a decrease in signal intensity of the involved bone and soft tissues; on T2-weighted images there was increased signal intensity. Depending on the stage of the disease, three different patterns of infection were revealed: osteitis, osteitis with an abscess, and osteitis with or without an abscess plus discitis. The anatomical pattern of involvement, particularly of the soft tissues and the discs, is specific for tuberculous disease. The ability of MRI to detect tuberculosis of the spine earlier than other techniques could reduce bone destruction and deformity and diminish the need for surgical intervention. Despite the specificity of the patterns revealed by MRI, biopsy is recommended during the stage of osteitis to confirm the diagnosis.

Abscess↗

The association between spontaneous reversal of gingival recession in mandibular incisors and dentofacial changes in children. A 3-year longitudinal study.

In a previous 3-year longitudinal study, reversal of gingival recession in mandibular incisors was observed for 16 out of 28 participating children aged 6-13 years (Andlin-Sobocki et al., 1991). In the present report various dentofacial conditions that might be associated with this reversal were evaluated from dental casts and cephalometric radiographs by comparing the 16 children with spontaneous reversal of gingival recession (Group Rev) to the 12 children with persisting gingival recession (Group Per). Dental casts and cephalometric radiographs were obtained at baseline and after three years. The findings indicate that the children with persisting gingival recession tended to have a particular facial morphology and incisor pattern. They were likely to have a larger basal bone discrepancy between the maxillary and mandibular jaws, with somewhat more proclined and more irregularly positioned mandibular incisors. Although a reduction in incisor irregularity and a slight increase in anterior arch widths occurred for both groups during the observation period, the tooth alignment situation in Group Per at the end of the observation period was similar to that of Group Rev at baseline. Additionally, in Group Rev all facially deviating incisors with recession at baseline had self-corrected at 3 years. This was not the case for Group Per. Thus, spontaneous reversal of gingival recession in mandibular incisors seem to be related to developmental changes in the dentition favouring incisor alignment.

Adolescent↗

Diagnostic usefulness of chest computed radiography--film versus cathode-ray tube images.

Seventy-one plain chest images obtained by computed radiography (CR) with an imaging plate were interpreted on film and two kinds of cathode-ray tube (CRT) monitors installed separately at two facilities (1,024 x 1,536 pixels, 8 bits, and 1,024 x 1,280 pixels, 10 bits) by 20 radiologists and four chest internists. The clinical categories of these 71 cases included pulmonary nodules and interstitial abnormalities. Image reading sessions were held over a total of 4 days, ie, 2 days and then another 2 days, 3 weeks later. Twenty-four observers formed four groups with six members each. Two groups read either films or CRT images at one of the two facilities. In the second experiment, 26 of 71 images were compressed at 10:1, 19 of 71 were compressed at 20:1, and 26 were not compressed. Analyses of the areas under the receiver-operating characteristic curves showed no significant differences in detection of pulmonary abnormalities between film and CRT. In detecting interstitial pulmonary abnormalities, film was more sensitive than CRT monitor. There were no significant differences in observers' performances between the two different kinds of CRT workstation. Subjective evaluation of image quality showed that images irreversibly compressed to the ratios of 10:1 and 20:1 were inferior to original images. Although further considerations are needed with regard to spatial resolution requirements, image processing, and image compression, the utilization of CR CRT image as a substitute for CR film image will be possible.

Data Display↗

Diagnosis of aortic dissection: value of helical CT with multiplanar reformation and three-dimensional rendering.

OBJECTIVE: Twenty-three patients with suspected aortic dissection were evaluated in this preliminary study of helical CT to determine the usefulness of axial sections, multiplanar reformation, and three-dimensional (3D) rendering in assessing the presence of dissection and the extent of intimal flap. MATERIALS AND METHODS: Patients were referred for helical CT scanning because of chest pain or an abnormal chest radiograph. Scans were performed during bolus injection of nonionic contrast material at 2.0-2.5 ml/sec using a mean scan delay of 47 sec. Axial scans with 5-mm collimation were obtained in all patients. They extended from the great vessels to the distal thoracic aorta just above the hiatus. Delayed nonhelical sections were obtained through the upper abdomen. Multiplanar reformations and 3D models were reconstructed from the helical data in 13 patients and were compared to axial sections in 7 patients who proved to have documented dissection. The efficacy of CT was determined using surgery, angiography, or clinical outcome to establish the diagnosis. RESULTS: Of the 23 patients studied, axial sections resulted in 15 true-negative, 7 true-positive, and 1 false-positive interpretation. In three of seven patients with dissection, it was difficult to determine the extent of the intimal flap on axial sections; multiplanar reformation or 3D views clarified the relevant anatomy in all 3 cases. Among the 3D display methods, ray-sum projection views were superior to surface model or maximum-intensity-projection views. CONCLUSION: If studies of larger numbers of patients confirm our preliminary findings, multiplanar reformation and 3D rendering of helical CT scans will be a valuable addition to axial display of CT studies used to detect aortic dissection and to determine the extent of the intimal flap.

Adult↗

Quantitative analysis of coronary arteriograms by microprocessor cinevideodensitometry.

A rapid microprocessor technique for measuring the cross-sectional area, diameter, and relative percentage stenosis of coronary atherosclerotic lesions by cinevideodensitometric analysis was developed and validated. Video images of projected 35-mm coronary arteriographic cine frames were analyzed from cinevideodensitometric profile curves recorded for the catheter shaft, normal artery, and stenotic segment. In radiographic phantom studies of calibrated, contrast-filled, plexiglass cylinders, cinevideodensitometric measurements correlated linearly with percentage relative stenosis (r = 0.98; SEE = 4.1%), diameter (r = 0.99; SEE = 0.12 mm), and cross-sectional area (r = 0.99; SEE = 0.32 mm2). In postmortem studies of two patients dying after coronary arteriography, cross-sectional areas of arterial segments measured by cinevideodensitometry correlated well (r = 0.99; SEE = 0.71 mm) with areas of acrylic resin casts of the coronary arteries. Intraobserver variability (r = 0.99; SEE = 2.6%) and interobserver variability (r = 0.96; SEE = 5.3%) of cinevideodensitometric measurements of coronary arteriograms were low. Additionally, percentage relative stenosis measured in the right anterior oblique projection correlated well with measurements in the left anterior oblique projection (r = 0.98; SEE = 0.11 mm2) of patients with eccentric stenotic lesions. Lastly, cinevideodensitometric measurements were significantly (p less than 0.05) more reproducible than caliper measurements. This inexpensive dedicated microprocessor system provides rapid cinevideodensitometric measurements of coronary arterial dimensions, without requiring manual tracing of arterial segments or the major expense of a main-frame computer system.

Absorptiometry, Photon↗

Developments towards the slice-wise three-dimensional reconstruction of the distribution of the contrast perfusion in the myocardial muscle from biplane angiographic views.

In theory, radiographic myocardial perfusion imaging allows a quantitative assessment of the functional significance of a coronary stenosis. However, in the conventional two-dimensional projection images there does not exist a one-two-one relationship between a selected myocardial region of interest (ROI) and one particular coronary segment perfusing that area due to over-projection of myocardial regions in front of and behind the selected ROI perfused by other arterial segments, which may result in measurements which are difficult to interpret or even unreliable. To overcome these problems, we have developed two algorithms to determine the spatial distribution of perfusion levels in slices of the heart, selected approximately perpendicular to the left ventricular long axis, from two orthogonal angiographic views: the Segmental Reconstruction Technique (SRT) and the Network Programming Reconstruction Technique (NPRT). Both techniques require a priori geometric information about the myocardium, which can be obtained from the epicardial coronary tree (epicardial boundaries) and the left ventricular lumen (endocardial boundaries). Using the SRT approach, pie-shaped segments are defined for each slice within the myocardial geometric constraints such that superimposition of these segments when projected in orthogonal biplane views is minimal. The reconstruction process uses a model with identical myocardial geometry and definition of segments. Each segment of the model is assigned a relative perfusion level with unit one if no other a priori information is available. In this case, the model contains geometric information only. In case a priori information about expected segmental perfusion levels is available, a level between zero and one is assigned to each segment. The a priori information on the myocardial perfusion levels can be extracted from either anatomic information about the location and severity of existing coronary arterial obstructions, or from a slice adjacent to the one under reconstruction. Using the NPRT approach perfusion levels are computed for each volume picture element of a slice within the reconstructed myocardial geometry, thus resulting in a much higher spatial resolution than the SRT approach. A priori information of perfusion levels must be included in this approach, again based upon anatomical information, or upon the slice adjacent to the one under reconstruction. The very first slice of a myocardial study will be reconstructed by the SRT approach. Extensive computer simulations for the SRT have proved that the mean difference between the actual and reconstructed segmental perfusion levels, on a scale from 0 to 1, is smaller than 0.45 (SEE = 0.0033, REE = 1.80) for various coronary artery disease states without the use of a priori information on expected perfusion levels. This error becomes smaller than 0.36 (SEE = 0.0026, REE = 1.42), if a priori information in the reconstruction technique is included. Similar computer simulations for the NPRT have proved that these mean differences in geometric segments equal to those defined for the SRT, are smaller than 2.94 (SEE = 0.0308, REE = 0.77) on a scale from 0 to 16, without the use of a priori information on expected perfusion levels, and smaller than 1.72 (SEE = 0.0304, REE = 1.10) on the same scale when a priori information is included. Therefore, it may be concluded that slice-wise three-dimensional reconstruction of perfusion levels is feasible from biplane computer-simulated data, and that a similarity exists for mean perfusion levels in corresponding regions in the simulated and reconstructed slices, for various states of single coronary artery disease.

Algorithms↗

Teleradiology image transmission system: diagnostic accuracy at three matrix sizes for various types of images.

The interpretability of transmitted digitized radiographic images is an important factor in the operation and use of teleradiology systems. Matrix size may influence diagnostic accuracy of the interpretation. Commercially available equipment has certain built-in image enhancement controls that may increase the interpretability of the image received. Evaluation of the effect of varying the matrix size and other factors on diagnostic accuracy are described.

Computer Communication Networks↗

Three-dimensional display of cardiac structures using reconstructed magnetic resonance imaging.

It is sometimes difficult to understand the three-dimensional (3D) relationship of cardiac and mediastinal structures despite advances in magnetic resonance (MR) imaging techniques. We present a low-cost system for 3D reconstruction of the major mediastinal structures by processing the MR imaging data on a NeXT workstation. MR images of multisection, multiphase, spin-echo techniques stored in a picture archiving and communication system (PACS) data base were used for the reconstruction. The computer program obtained the contours of the multiple components of the mediastinal structures by the combination of automatic and manual procedure. The bundled software of a 3D kit was used for surface rendering of hidden surface removal, shading of the visible parts of the surfaces, perspective transformation, and motion parallax by rotation of the surfaces. 3D reconstruction was performed in 15 patients with cardiac diseases, and the 3D-reconstructed images were compared with the plain chest x rays of the patients. The 3D presentation clearly showed the complex anatomy of cardiovascular diseases and helped elucidate the misconceptions in the interpretation of the plain chest x rays. Our 3D images are used for education and should be viewed by medical students and beginners in radiology at an individual pace with plain chest radiographs, MR images, and legends. Although applied to the heart and the great vessels in this report, this system is also applicable to other structures.

Computer Graphics↗

Detection of lung nodules in digital chest radiographs using artificial neural networks: a pilot study.

Radiologists can fail to detect up to 30% of pulmonary nodules in chest radiographs. A back-propagation neural network was used to detect lung nodules in digital chest radiographs to assist radiologists in the diagnosis of lung cancer. Regions of interest (ROIs) that contained nodules and normal tissues in the lung were selected from digitized chest radiographs by a previously developed computer-aided diagnosis (CAD) scheme. Different preprocessing techniques were used to produce input data to the neural network. The performance of the neural network was evaluated by receiver operating characteristic (ROC) analysis. We found that subsampling of original 64- x 64-pixel ROIs to smaller 8- x 8-pixel ROIs provides the optimal preprocessing for the neural network to distinguish ROIs containing nodules from false-positive ROIs containing normal regions. The neural network was able to detect obvious nodules very well with an Az value (area under ROC curve) of 0.93, but was unable to detect subtle nodules. However, with a training method that uses different orientations of the original ROIs, we were able to improve the performance of the neural network to detect subtle nodules. Artificial neural networks have the potential to serve as a useful classifier to help to eliminate the false-positive detections of the CAD scheme.

False Positive Reactions↗

Computed tomography interpretations with a low-cost workstation: a timing study.

An ergonomically simple prototype workstation with two 900 x 1,100-pixel monitors capable of displaying eight full-resolution computed tomography (CT) images in 0.2 seconds, was compared with film for interpretation of computed tomographic images of the chest and abdomen. The hardware platform for this workstation cost less than $11,500 in 1993. A repeated-measures experiment was used to generate average interpretation times of 6.17 minutes for the workstation and 6.03 minutes for the film, including loading and unloading films, with three of the four subjects averaging about a minute longer for each workstation interpretation. All dictated reports were of clinically acceptable accuracy. All radiologists stated that workstations based on this design would be an acceptable clinical tool. However, observation suggested human working-memory strain among infrequent CT readers that could indicate the need for additional training. These data suggest that low-cost workstations can have practical application in interpretation of digital medical images such as CT, with the possibility of small increases in interpretation time.

Adult↗

A review on biomedical image processing and future trends.

The last two decades have witnessed a revolutionary development in the field of biomedical and diagnostic imaging. Imaging procedures and modalities which were only in the experimental research phase in the early part of the last two decades, have now become universally accepted clinical procedures. They include computerized tomography (CT), magnetic resonance imaging, ultrasound imaging, nuclear medicine imaging, computerized hematological cell analysis, etc. In the past, the conventional and relatively simple image processing techniques such as image enhancement, gray-level mapping, spectral analysis, region extraction, etc. have been modified for biomedical images and successfully applied for processing and analysis. The role of image enhancement, gray-level mapping, and image reconstruction from projections algorithms in CT and other radiological imaging modalities is well evident. Recently, many advances in biomedical image processing, analysis, and understanding algorithms have shown a great potential for enhancing and interpreting useful diagnostic information from these images more accurately. This paper presents a review on the current state-of-the-art techniques in biomedical image processing and comments on future trends.

Algorithms↗

Carpal orientation from computed reference axes.

Carpal instability is usually diagnosed by abnormal two-plane radiographic angles. These angles are often unreliable. A method that eliminates interpretation of overlapping shadows and uses all of the carpal geometry should improve clinical diagnoses. The digital data from computed tomography scans can be manipulated to describe the carpal orientation in the normal wrist. The digital data from the computed tomography scans of twenty-two normal wrists were used to compute distances with and without directions between the volumetric centroids of the carpal bones. An expansion technique also extracted from the computed tomography data an orthogonal set of vectors, the principal axes. The first principal axis describes the longest dimension of each bone. The average angle produced by the first principal axes of the scaphoid and lunate was 23.6 degrees, scaphoid and capitate was 73.2 degrees, and the capitate and the lunate was 93.5 degrees. These computations represent new carpal axes and intercarpal angles that are not related to the commonly measured two-plane radiographic angles. They should prove helpful in the study of kinematics and pathomechanics in the wrist joint.

Carpal Bones↗