PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “systems drift”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Disequilibrium pattern analysis. II. Application to Danish HLA A and B locus data.

Disequilibrium pattern analysis, a general method for analyzing evolutionary events acting on pairs of tightly linked polymorphic loci, is applied to a large sample of Danish individuals typed for A and B loci of the HLA (human leukocyte antigen) system. Cases of selection on particular haplotypes are revealed from patterns of linkage disequilibrium among the HLA haplotypes. These patterns cannot be explained by either population admixture or random genetic drift. Six haplotypes out of the total array of 273 haplotypes have been identified which show in varying extents the patterns indicating selection.

Alleles↗

Genetic effect of transportation infrastructure on roe deer populations (Capreolus capreolus).

Anthropogenic transportation infrastructure is a major factor of habitat fragmentation leading to genetic population fragmentation in wildlife. Assessing and understanding the impact of this deterministic factor on genetic diversity and divergence of populations is crucial to appraise the viability of wildlife populations in fragmented landscapes. In this study, the roe deer is used as an example species for the assessment of genetic differentiation of populations separated by an anthropogenic barrier. In order to detect genetic discontinuities, we screened 12 polymorphic microsatellites on 222 individuals out of 11 roe deer populations that were sampled on the east and the westside of a fenced motorway in Central Switzerland. The interaction between landscape structure and microevolutionary processes such as gene flow and drift were assessed and evaluated by different population genetic methods like F-statistics, Mantel test, spatial autocorrelation analyses, Monmonier algorithm, and principal component analysis in conjunction with geographic information system data (synthesis map). We revealed an influence of the transportation infrastructure on genetic divergence of the roe deer population examined, but no impact on genetic diversity was detected. Based on the achieved genetic findings, recommendations for management implementation were made.

Animal Migration↗

Afterimage-like effects in the motion-sensitive neuron H1.

A powerful effect resembling an afterimage is demonstrated on the pathway to the motion-sensitive neuron H1. This effect is independent of the locally generated gain control described in an earlier paper (Maddess & Laughlin 1985, Proc. R. Soc. Lond. B 225, 251). The afterimage, produced across the eye by a stationary pattern, causes the sensitivity to movement to be different according to the local stimulus history, and the effects of low-contrast (0.1) patterns, presented for as little as a few hundred milliseconds, remain for up to 2 s. Moving patterns interact with the afterimage to modulate the spike rate of H1. The afterimage increases with contrast but saturates at contrasts above 0.5. Low spatial frequencies generate afterimages less effectively than moderate ones; this result indicates that the afterimage process could lie at, or after, lateral inhibition between tonic units. This is supported by the fact that the altered sensitivity profiles generated by single bright and dark vertical bars initially resemble Mach bands. However, this character alters as the afterimage decays, and the depression of H1's response to moving bright stimuli, produced by the afterimage of a dark bar, continues to grow for up to 1 s after the adapting bar is removed. A short-lived (0.5 s) reduction of H1's directional selectivity accompanies strong afterimage formation. All these factors, especially the saturation at low contrasts and the spatial frequency tuning, rule out light adaptation by photoreceptors as the afterimage source. Luminances used were also low enough to exclude influence by the pupil mechanism. Lastly, responses to patterns that are occasionally jumped by large or small distances are broadened by stimuli that produce an afterimage. Responses to small displacements have previously been described as 'velocity impulse responses' (Srinivasan 1983, Vision Res. 23, 659; Zaagman et al. 1983, IEEE Trans. SMC 13, 900) and so the response broadening (stimulus blurring) can be taken as a reduction of the fly's temporal resolution of moving objects. Previously reported work shows that afterimages seen in humans and the effect reported here act over the same range of temporal frequencies rather than retinal drift speeds. This may suggest an important role for afterimage-like effects in the processing of the low temporal frequency components of moving images. Certainly, the fly's afterimage system reduces the visibility of moving objects within patches of an image that, have on average, contained slowly varying motion signals.(ABSTRACT TRUNCATED AT 400 WORDS)

Afterimage↗

Advances in ICP monitoring techniques.

With the advent of newer devices for measuring intracranial pressure (ICP) and cerebral metabolism, more alternatives continue to rise aiming to control ICP. This manuscript presents a proposed analysis of different ICP monitoring devices in order to make appropriate selection of them in our clinical setting including general and pediatric applications. A systematic review of the literature was made analyzing the technical advances in ICP monitoring. The recent in vitro and in vivo tests as well as mathematical/computer models were reviewed. Practical applications of principles were discussed and compared based on the mode of pressure transformation. A ventricular catheter connected to an external strain gauge transducer or catheter tip pressure transducer device is considered to be the most accurate method of monitoring ICP and enables therapeutic CSF drainage. The significant infections or hemorrhage associated with ICP devices causing patients morbidity are clinically rare and should not deter the decision to monitor ICP. Parenchymal catheter tip pressure transducer devices are advantageous when ventricular ICP cannot be obtained or if there is an obstruction in the fluid couple, though they have the potential for significant measurement differences and drift due to the inability to recalibrate. Subarachnoid or subdural fluid-coupled devices and epidural ICP devices are currently less accurate. With an increasing miniaturization of the transducers, fiberoptic systems have been developed, however, there is a problem of measurement accuracy during the period of patient monitoring and external calibration should be performed frequently to ensure constant accuracy. Ventriculostomies continue to have a pivotal role in ICP control. With a rational understanding of the applications and limitations of the different ICP monitoring devices, the outcome for critically ill neurological patients is optimized.

Animals↗

A quantitative comparison of a position measurement system and accelerometry.

An electro-mechanical system to characterize the dynamic performance of a position measurement system was constructed. The system produced pure sine wave kinematics over the frequency range of 1-11 Hz. Synchronous measurements of the position (using infra-red light emitting diodes) and the acceleration were taken at discrete frequencies. The position signal was filtered and differentiated twice to obtain an estimated acceleration. The acceleration estimate was compared to the acceleration reading from the accelerometer, and both were compared to the theoretical acceleration. The comparison was based on extracting average features of the signal like amplitude, offset and noise. The results show that the accelerometer measurements matched the theoretical amplitude to within 1-3% over most of the range but showed significant offset drift. The acceleration estimates based on the position measurements were highly dependent on the filtering scheme, showed no significant offset but had higher levels of noise. The experimental measurements and the mathematical analysis quantitatively compared the dynamic performance of the position measurement system and the accelerometer. Such a system could be used to optimize the performance of position measurement devices, by comparing different filtering and/or differentiating schemes.

Acceleration↗

Detection of genome-scale ordered RNA structure (GORS) in genomes of positive-stranded RNA viruses: Implications for virus evolution and host persistence.

Discrete RNA secondary and higher-order structures, typically local in extent, play a fundamental role in RNA virus replication. Using new bioinformatics analysis methods, we have identified genome-scale ordered RNA structure (GORS) in many genera and families of positive-strand animal and plant RNA viruses. There was remarkably variability between genera that possess this characteristic; for example, hepaciviruses in the family Flaviviridae show evidence for extensive internal base-pairing throughout their coding sequences that was absent in both the related pestivirus and flavivirus genera. Similar genus-associated variability was observed in the Picornaviridae, the Caliciviridae, and many plant virus families. The similarity in replication strategies between genera in each of these families rules out a role for GORS in a fundamentally conserved aspect of this aspect of the virus life cycle. However, in the Picornaviridae, Flaviviridae, and Caliciviridae, the existence of GORS correlated strongly with the ability of each genus to persist in their natural hosts. This raises the intriguing possibility of a role for GORS in the modulation of innate intracellular defense mechanisms (and secondarily, the acquired immune system) triggered by double-stranded RNA, analogous in function to the expression of structured RNA transcripts by large DNA viruses. Irrespective of function, the observed evolutionary conservation of GORS in many viruses imposes a considerable constraint on genome plasticity and the consequent narrowing of sequence space in which neutral drift can occur. These findings potentially reconcile the rapid evolution of RNA viruses over short periods with the documented examples of extreme conservatism evident from their intimate coevolution with their hosts.

Animals↗

Dispersal and Inbreeding Avoidance.

Using a game-theoretical approach, we investigate the dispersal patterns expected if inbreeding avoidance were the only reason for dispersal. The evolutionary outcome is always complete philopatry by one sex. The rate of dispersal by the other sex depends on patch size and mating system, as well as inbreeding and dispersal costs. If such costs are sex independent, then two stable equilibria coexist (male or female philopatry), with symmetric domains of attraction. Which sex disperses is determined entirely by history, genetic drift, and gene flow. An asymmetry in costs makes one domain of attraction extend at the expense of the other. In such a case, the dispersing sex might also be, paradoxically, the one that incurs the higher dispersal costs. As asymmetry increases, one equilibrium eventually disappears, which may result in a sudden evolutionary shift in the identity of the dispersing sex. Our results underline the necessity to control for phylogenetic relationships (e.g., through the use of independent-comparisons methods) when investigating empirical trends in dispersal. Our model also makes quantitative predictions on the rate of dispersal by the dispersing sex and suggests that inbreeding avoidance may only rarely be the sole reason for dispersal.

evolutionarily stable strategy↗

Ambulatory measurement of arm orientation.

In order to evaluate the impact of neuromuscular disorders affecting the upper extremities, the functional use of the arm need to be evaluated during daily activities. A system suitable for measuring arm kinematics should be ambulatory and not interfere with activities of daily living. A measurement system based on miniature accelerometers and gyroscopes is adequate because the sensors are small and do not suffer from line of sight problems. A disadvantage of such sensors is the cumulative drift around the vertical and the problems with aligning the sensor with the segment. A method that uses constraints in the elbow to measure the orientation of the lower arm with respect to the upper arm is described. This requires a calibration method to determine the exact orientation of each of the sensors with respect to the segment. Some preliminary measurements were analyzed and they indicated a strong reduction in orientation error around the vertical. It seemed that the accuracy of the method is limited by the accuracy of the sensor to segment calibration.

Acceleration↗

Ecological and immunological determinants of influenza evolution.

In pandemic and epidemic forms, influenza causes substantial, sometimes catastrophic, morbidity and mortality. Intense selection from the host immune system drives antigenic change in influenza A and B, resulting in continuous replacement of circulating strains with new variants able to re-infect hosts immune to earlier types. This 'antigenic drift' often requires a new vaccine to be formulated before each annual epidemic. However, given the high transmissibility and mutation rate of influenza, the constancy of genetic diversity within lineages over time is paradoxical. Another enigma is the replacement of existing strains during a global pandemic caused by 'antigenic shift'--the introduction of a new avian influenza A subtype into the human population. Here we explore ecological and immunological factors underlying these patterns using a mathematical model capturing both realistic epidemiological dynamics and viral evolution at the sequence level. By matching model output to phylogenetic patterns seen in sequence data collected through global surveillance, we find that short-lived strain-transcending immunity is essential to restrict viral diversity in the host population and thus to explain key aspects of drift and shift dynamics.

Antigenic Variation↗

Cardiovascular drift during prolonged exercise and the effects of dehydration.

Reductions in SV are the most striking component of "classic" CV drift as well as "dehydration induced" CV drift. Direct data for the widespread notion that increased skin blood flow causes SV to be reduced during "classic" CV drift is rather scarce. Reductions in SV due to dehydration and concomitant hyperthermia are clearly not due to increases in skin blood flow. Instead, skin blood flow declines as skin and systemic vascular resistance increase as the CV system attempts to cope with the severe challenge of large reductions in cardiac output. Approximately one-half of the reduction in SV is due to reduced blood volume from dehydration during exercise which produces hyperthermia. The remaining reduction in SV with dehydration and hyperthermia appears to be related to additional factors such as hyperthermia and their interaction with factors that further reduce ventricular filling, such as heart rate acceleration.

Blood Volume↗

Subchronic inhalation exposure to acetone vapor and scheduled controlled operant performance in male rats.

Groups of adult male rats (10/group) were used to assess whether subchronic inhalation exposure to 0, 1000, 2000, or 4000 ppm of acetone vapor altered schedule-controlled operant performance. Rats were exposed to acetone vapor for 6 h/day, 5 days/wk, for a 13-wk period. Extensive training prior to the exposure series established a stable baseline of lever-pressing on a multiple fixed-ratio-fixed-interval (FR 20-FI 120 s) schedule of food presentation. Operant sessions occurred prior to each daily exposure to avoid confounding the detection of enduring behavioral effects with transient acute effects. FI response rate, FI index of curvature, and FR running rate of response were not affected during or after the 13-wk exposure series. FR post-reinforcement pause duration for the control group increased during the course of the study more than that of the 2000 ppm and 4000 ppm groups, which changed only slightly relative to pretreatment baseline. Based on the performance of historical controls that had FR pause durations similar to those of acetone-treated groups, the differences in FR pause duration were probably due to drift of the concurrent control group and were not related to acetone treatment. Prolonged exposure to up to 4000 ppm acetone vapor does not appear to have enduring effects on nervous system functions that mediate the performance of a complex, learned task.

Acetone↗

The role of sex chromosomes in black fly evolution.

Sex chromosomes have been repeatedly implicated in the process of speciation of black flies and other nemotocerans. Arguments are presented here against the case that frequent differences between species in their sex chromosomes are based on (i) different average rates of differentiation of sex-linked and autosomal loci or (ii) the fact that the X and Y chromosomes are less numerous than autosomal chromosomes and so are more subject to the effects of drift and the random fixation of chromosome rearrangements. The argument is made that speciation in black flies and many other groups is an adaptive process and that differentiated sex-chromosome systems play a role in this process.

Animals↗

Discrimination of rotation from linear motion: influence of interference gratings and dichoptic viewing.

Observers viewed a screen on which a number of patches containing horizontally moving pixels were presented. Target patches consisted of pixels whose motion simulated the rotation of a cylinder around its Y-axis; distractors, of pixels whose motion was linear. The task was to assess whether a display contained a target patch. Exp. 1 showed that the superposition of the displays with drifting sine-wave gratings interfered with rotation detection in a spatial- and temporal-frequency specific manner. In Exp. 2, dichoptic presentation greatly reduced the interference of the drifting gratings. It is argued on various grounds that the process(es) responsible for the detection and discrimination of rotating structure in depth exists at a low level of the visual system.

Attention↗

An evaluation of the improved Technicon Chem 1 system.

The improved selective multitest analyser Technicon Chem 1 was evaluated according to the ECCLS guidelines in our laboratory. Twenty two routine parameters were examined. The trial also included a clinical evaluation. About 50,000 measurements were performed during six weeks. The following conclusions can be drawn: 1. The changes made in the system (mainly software) led to genuine improvements. 2. The precision of the system can be rated as good. With a few exceptions (alkaline phosphatase, lactate dehydrogenase, creatine kinase, albumin and total bilirubin) all between-day coefficients of variation are lower than 3%. 3. Excellent agreement was found between the results obtained from the Chem 1 and from the comparison methods. 4. No drift was observed. Once calibrated the Chem 1 can be used for at least fifteen days without renewed calibration, except for the analysis of sodium, potassium and calcium. 5. No carry-over was observed, either specimen-related, or reagent-related. 6. Though not all methods were examined in detail, in general the linearity was found to agree with the manufacturer's claims. 7. The influence of interfering substances proved to be moderate. 8. The practicability of the system was good. A more complete judgement is given in the Discussion Section.

Blood Chemical Analysis↗

Purkinje-muscle reentry as a mechanism of polymorphic ventricular arrhythmias in a 3-dimensional model of the ventricles.

Multiple electrode mapping of the ventricles during complex tachyarrhythmias has revealed focal subendocardial activation whose mechanism remains unexplained. We hypothesized that reentry involving the Purkinje-muscle junctions (PMJs) may be a mechanism for such focal excitations. We have constructed an anatomically appropriate computerized 3-dimensional model of the mammalian ventricles that includes the Purkinje conduction system and 214 PMJs distributed throughout the endocardium. Isochronal maps during normal excitation, as well as during right or left bundle branch block, resembled experimental measurements and compared well with isochronal maps of propagation in the human heart. Activity observed at both sides of a PMJ in the model showed that propagation from Purkinje fibers to muscle was slower than in the opposite direction. Under these realistic and normal conditions, the evolution of reentrant activity involving muscle and the Purkinje network was simulated. The reentry pattern was independent of the initiation site. It evolved with drifting epicardial breakthroughs and transformed on the endocardium from focal activity to figure-of-8 reentry. In addition, the ECG amplitude undulated during the evolution, and decrease in the cycle period, apparent wavelength, and propagation velocity were observed. Finally, the reentry was terminated if the Purkinje system was disconnected from the muscle before it reached a relative steady state. The simulation results suggest the following: (1) Epicardial breakthroughs and endocardial focal activity may originate at the PMJs. (2) The ECG amplitude may decrease as the reentry stabilizes and the excitation wavelength decreases. (3) The Purkinje system may have a double role in the evolution of reentry: first, it is essential to the reentry at the initial stage; second, it may lead to the establishment of intramyocardial reentry, at which time the Purkinje system becomes irrelevant.

Action Potentials↗

Ratiometry of transmembrane voltage-sensitive fluorescent dye emission in hearts.

Transmembrane voltage-sensitive fluorescence measurements are limited by baseline drift that can obscure changes in resting membrane potential and by motion artifacts that can obscure repolarization. Voltage-dependent shift of emission wavelengths may allow reduction of drift and motion artifacts by emission ratiometry. We have tested this for action potentials and potassium-induced changes in resting membrane potential in rabbit hearts stained with di-4-ANEPPS [Pyridinium, 4-(2-(6-(dibutylamino)-2-naphthalenyl) ethenyl)-1-(3-sulfopropyl)-, hydroxide, inner salt] using laser excitation (488 nm) and a two-photomultiplier tube system or spectrofluorometer (resolution of 500-1,000 Hz and <1 mm). Green and red emissions produced upright and inverted action potentials, respectively. Ratios of green emission to red emission followed action potential contours and exhibited larger fractional changes than either emission alone (P < 0.001). The largest changes and signal-to-noise ratio (signal/noise) were obtained with numerator wavelengths of 525-550 nm and denominator wavelengths of 650-700 nm. Ratiometry lessened drift 56-66% (P < 0.015) and indicated decreases in resting membrane potential. Ratiometry lessened motion artifacts and increased magnitudes of deflections representing phase-zero depolarizations relative to total deflections by 123-188% in intact hearts (P < 0.02). Durations of action potentials at different pacing rates, temperatures, and potassium concentrations were independent of whether they were measured ratiometrically or with microelectrodes (P > or = 0.65). The ratiometric calibration slope was 0.017/100 mV and decreased with time. Thus emission ratiometry lessens the effects of motion and drift and indicates resting membrane potential changes and repolarization.

Animals↗

Response monitoring and action limits: use of ADC numbers in understanding the operational characteristics of the Beckman ASTRA chemistry system.

The Beckman ASTRA is a microprocessor-controlled multichannel chemistry analyzer. The output of each module is available to the operator as analog-to-digital conversion (ADC) numbers, which we record during each calibration (Response Monitoring). After so studying three instruments for a total of 33 months, we have established limits for Calibrator ADC numbers that indicate possible operator action (Action Limits). These Action Limits are tighter than the microprocessor's programmed limits, and alert the operator to short- and long-term drift. These tighter limits warn of (a) impending failure of the instrument to calibrate or (b) possible inaccuracies in results for patients. We have instituted changes in preventive maintenance based on our studies of each module's operational characteristics, and have replaced electrodes that failed to meet our Response Monitoring specifications. Response Monitoring and Action Limits based upon ADC numbers have significantly enhanced our understanding of the ASTRA system and thus improved its operational efficiency and analytical reliability. Estimates of precision and accuracy (true value) were satisfactory in comparison to our prior single-channel continuous-flow and flame photometry analytical measurement systems.

Autoanalysis↗

Coexistence and error propagation in pre-biotic vesicle models: a group selection approach.

Compartmentalization of unlinked, competing templates is widely accepted as a necessary step towards the evolution of complex organisms. However, preservation of information by templates confined to isolated vesicles of finite size faces much harder obstacles than by free templates: random drift allied to mutation pressure wipe out any template that does not replicate perfectly, no matter how small the error probability might be. In addition, drift alone hinders the coexistence of distinct templates in a same compartment. Here, we investigate the conditions for group selection to prevail over drift and mutation and hence to guarantee the maintenance and coexistence of distinct templates in a vesicle. Group selection is implemented through a vesicle survival probability that depends on the template composition. By considering the limit case of an infinite number of vesicles, each one carrying a finite number of templates, we were able to derive a set of recursion equations for the frequencies of vesicles with different template compositions. Numerical iteration of these recursions allows the exact characterization of the steady state of the vesicle population-a quasispecies of vesicles-thus revealing the values of the mutation and group selection intensities for which template coexistence is possible. Within the main assumption of the model-a fixed, finite or infinite, number of vesicles-we find no fundamental impediment to the coexistence of an arbitrary number of template types with the same replication rate inside a vesicle, except of course for the vesicle capacity. Group selection in the form of vesicle selection is a must for compartmentalized primordial genetic systems even in the absence of intra-genomic competition of different templates.

Animals↗