PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pupil dynamics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

Pupillometry in clinically sleepy patients.

OBJECTIVES: Investigators have suggested using pupillometry to assess alertness in hypersomnolent patients. In this study we assessed hypersomnolent patients and normal volunteers by using pupillometry and examined the usefulness of this technique for the diagnosis of pathologic sleepiness in individual patients. METHODS: Forty-nine patients were examined by pupillometry and their sleepiness was assessed by using the multiple sleep latency test (MSLT). Thirty-three normal well-rested volunteers were also examined by pupillometry. The patients were classified as having 'mild', 'moderate', or 'severe' sleepiness, based on their mean MSLT sleep latency. Several dynamic variables of pupil diameter were calculated from the pupillograms and correlated with the mean MSLT sleep latency, and were compared between severity groups of patients and the well-rested normal subjects. RESULTS: All but two pupillometric variables were significantly correlated with sleep latency. All except the same two pupillometric variables of the sleepiest group were significantly different from those of normal subjects. However, only 51% of patients with mean sleep latencies less than 10 min and 35% of patients with mean sleep latencies of less than 5 min could be correctly identified by pupillometry. CONCLUSIONS: Pupillometry is clearly associated with differences in alertness between groups of patients. However, pupillometric assessment cannot substitute for the MSLT in most cases.

Journal Article↗

Repeatability and validity of the PowerRefractor and the Nidek AR600-A in an adult population with healthy eyes.

We assessed the repeatability and validity of the PowerRefractor and the Nidek AR-600A autorefractor. This is the first independent study conducted on adults to evaluate the performance of these instruments in a laboratory setting. Fifty subjects (23 males and 27 females) aged 16 to 61 years (mean, 37 +/- 12) participated in the study. The validity of the PowerRefractor and the Nidek autorefractor readings were determined by comparing them to subjective refraction. Measurements of refractive error were obtained from the two instruments on two separate occasions to assess their repeatability. The measured refractive error was converted into a dioptric power matrix for data analysis. No significant difference was found between the measurements obtained with the two instruments and the subjective refraction. The estimate of refractive error given by the two instruments was also found to be repeatable. In addition to measuring the refractive error, the PowerRefractor also offers the facility to measure eye position, pupil size, and dynamics of accommodation. We suggest some improvements to the PowerRefractor measurement technique to standardize its clinical use and to improve accuracy.

Adolescent↗

Effects of benactyzine hydrochloride on dynamic vision functions.

We have investigated the effects of an anticholinergic drug, benactyzine HCl on vision and vision function. Our experiments assess the time course and severity of benactyzine effects on visual acuity for static and moving targets, amplitude and dynamics of accommodation, pupil response to light and the spatial contrast sensitivity function. A single dose of the drug (4.14 mg/70 kg body weight, which is within the therapeutic range) and placebo were administered intramuscularly to 12 subjects. Large and significant decrements in visual function were demonstrated after the administration of benactyzine, particularly for those functions performed at near focus. The drug effect was rapid in onset, beginning 7-10 min after injection, peaked at approximately 30-40 min, and declined to baseline values over the next 2 h. The drug increased pulse rate and blood pressure, and induced an intoxicated state involving loss of concentration, attention, and short-term memory.

Accommodation, Ocular↗

[Ophthalmopathy due to environmental toxic substances especially intoxication by organophosphorus pesticides].

Organophosphorus pesticides (OPs) produce optico-autonomic peripheral neuropathy in human populations in districts where a large amount of pesticides have been used in agriculture. This report presents an epidemiological study that was performed in Kanagawa Prefecture. An autopsy case of a professional organophosphorus sprayer is reported. In addition, an experiment was performed to investigate a non-cholinergic chronic toxicity due to a certain OP. The epidemiological study revealed that 64 of 7,435 farmers showed vertical smooth pursuit defect of the eyes, impairments of modulation-transfer function (MTF) of the visual system and abnormal contraction dynamics of the pupil reaction to light stimuli, and a high residual level of OP was found in their blood. These abnormalities were reduced by treatment with antidotes such as atropine, prifinium bromide, and pralidoxime methiodide (PAM). The autopsy findings showed severe retinal degeneration with optic neuropathy and an obviously precocious progression of arteriosclerotic change in heart, brain, and retinal vessels. These findings can not be explained by cholinesterase inhibition alone. Experimental evidence showed that OP produced non-cholinergic impairment such as increase of Ca ions in retinal neurons. A generation of free radicals was noted in tissue-cultured retinal neurons. Blood selenium level was reduced by OP. These non-cholinergic actions may also explain the neural damage caused by long-standing low-dosage contact with OPs.

Adult↗

Effects of an anticholinergic drug, benactyzine hyrochloride, on vision and vision performance.

Benactyzine is an anticholinergic agent which has been used in past years in psychiatry, but is little used today. It has central and peripheral anticholinergic effects, and when administered intramuscularly, it has a rapid onset of action. This may make it useful as an antidote for organophosphate poisoning, in spite of side-effects such as deficits of short term memory, concentration, and attention. As an anticholinergic drug it could also be expected to produce vision changes by its action on the intraocular musculature controlling the pupil and lens accommodation. We tested the drug on six volunteer subjects to establish the visual side-effects of intramuscular administration. We found that it reduced static and dynamic visual acuity, increased pupil size, reduced amplitude of accommodation and contrast sensitivity, while having little or no effect on glare recovery, color vision, intraocular pressure, stereoacuity, oculomotor tracking, and distance heterophoria. Benactyzine produced reductions in visual performance for up to 3 h and had the greatest effects on functions which have significant cognitive components. The present results suggest that the drug is unsuitable for treatment for oganophosphate poisoning when continuous performance is required, although a definitive test of ths suggestion would require that performance should be tested when benactyzine and the organophosphate of interest were combined.

Adult↗

Physiology, assessment, and disorders of the pupil.

Proper examination of the pupil provides an objective measure of the integrity of the pregeniculate afferent visual pathway and allows assessment of sympathetic and parasympathetic innervation to the eye. Infrared videography and pupillography are increasingly used to study the dynamic behavior of the pupil in common disorders, such as Horner's syndrome and tonic pupil.

Humans↗

Pupillometer for clinical applications using dual 256-element linear CCD arrays.

A new pupillometer for measuring the size of the pupil of the human eye is described. It uses two inexpensive 256-element charge coupled device (CCD) arrays in an orthogonal configuration. The system is controlled and data are analysed by means of a Z80A microcomputer. Software allows the position and diameter of the pupil to be displayed on a monochrome video monitor. Infra-red diodes irradiate the eye so that measurements can be made in darkness. The accuracy is better than +/- 0.1 mm, over the range 3.2-9.5 mm. Dynamic measurements of the pupil light reflex response can be made with sampling periods as short as 20 ms.

Electronics, Medical↗

Dynamic impedance measurements during radio-frequency heating of cornea.

Hyperopia affects approximately 25% of the population. The aim of different heating modalities for the treatment of hyperopia is to steepen the central curvature of the cornea. Conductive keratoplasty (CK) involves the placement of radio-frequency (RF) lesions around a 7-mm-diameter ring concentric with the pupil of the eye. Dynamics of lesion formation during CK depend on corneal electrical impedance, which is expected to change during each 600-ms-long macropulse. The purpose of this study was to measure impedance dynamics during CK. RF lesions were made in in vitro porcine eyes at different power settings. Voltage and current measurements were acquired using a high-speed computer-based data acquisition system. Root-mean-square voltages (VRMS) and curre (IRMS) were calculated for each micropulse, and impedance was determined by calculating the quotient VRMS/IRMS. Initial corneal impedance in vitro was approximately 2000 ohms. During the macropulse, impedance decreased initially due to increased mobility of conductive ions. At higher power settings (e.g., > 70%, or maximum peak-to-peak voltage of 233 V), impedance increased after the initial decrease, indicative of local water vaporization and/or tissue coagulation. Preliminary impedance data obtained for in vivo porcine eyes were similar in magnitude to the in vitro values.

Animals↗

Midbrain single units correlating with pupil response to light.

The consensual response of the pupil in the cat was driven by means of a light flux impinging on the contralateral retina. Spike trains recorded extracellularly from single units in the midbrain show correlation with the concurrently recorded pupil area. The temporal dynamics found confirm two earlier studies of sinigle-unit responses and quantitative nerve stimulation. Both of these indicate that most of the 200-millisecond transport delay resides in the neuromuscular apparatus. Neurons whose activity correlated either with constriction with dilatation phases of Change in the pupil area were observed.

Animals↗

[Accommodative resting position and the effect of viewing distance on after-effects of accommodation and the pupil].

The resting position of accommodation is determined by the equilibrium established between sympathetic and parasympathetic tone. To accommodate for near objects is brought about by excitation of the parasympathetic, and distant objects call for excitation of the sympathetic system. To investigate accommodation and pupil after-effects following the 10 min visual task with stereoscopic three dimensional image, the measurements of the dynamic responses of accommodation and pupil were made. When the subjects worked at 0.4 m (closer than their resting state) and at 1 m corresponded to their resting positions, the response delay in accommodative relaxation occurred in each condition. When they worked at outside their resting position (1.5 m and 3 m viewing distances), the significant response delay in contraction in the groups of 1.5 m and 3 m, and the increases of accommodation error and the area of miosis were shown. There was a fact that the after-effect on accommodation and pupillary function was different between in the case of tasks given inside and outside their resting positions.

Accommodation, Ocular↗

[Correlation of basic properties of nervous processes with parameters of attention in middle school children].

Having checked the dynamics of attention in pupils of 5-8 classes we have established, that in those at the age of 11-14 the progressive but slow and non-uniform improvement of its parameters (volume, efficiency, switching and distribution of attention) occurred. In subjects at the age of 11 all the parameters of attention correlated significantly with peculiarities of the basic nervous processes but in those at the age of 12-13 coefficients of correlation were found to be reduced, and for those at the age of 14 relations between parameters of attention and peculiarities of the basic nervous processes were not determined.

Adolescent↗