PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “dynamic range”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4Linked to original sources

"Colored" noise waveforms and quadrupole excitation for the dynamic range expansion of Fourier transform ion cyclotron resonance mass spectrometry.

Fourier transform ion cyclotron resonance (FTICR) mass spectrometry offers unparalleled analytical performance in most regards but has a dynamic range of typically no better than 10(2)-10(3). This limitation reportedly arises from two opposing constraints, involving the maximum number of ions that can be effectively trapped (10(6)-10(7)) and the minimum number of ions required to produce a detectable signal (10(2)-10(3)). A potential solution to this dynamic range limitation is presented, based on the application of selected-ion accumulation using quadrupole excitation. We show that lower concentration species can be effectively accumulated in the FTICR trapped ion cell, while the more abundant species are continually removed by the application of quadrupolar excitation in the form of band-limited or "colored" noise waveforms. The result is that "room" is made in the cell for lower abundance species, even during extended accumulation periods. This approach was demonstrated with mixtures of the bovine proteins, insulin, ubiquitin, and cytochrome c. For normal accumulation, the dynamic range was approximately 100. The application of selected-ion accumulation in the form of colored noise allowed the extension by 2 orders of magnitude and the detection of species of 1 x 10(-8) M concentration from a solution also containing another component at 9 x 10(-5) M. With this method, a putative new low abundance variant of bovine insulin was observed, and selected-ion accumulation and subsequent collisionally activated dissociation were used for its identification. Dipolar magnetron excitation was also explored to enhance selected-ion accumulation and was found to reduce the amount of buffer gas required for complete removal of the undesired species by a factor of 5. Further possible improvements are discussed, as are the complications due to the required balance between magnetron and cyclotron damping rates.

Amino Acid Sequence↗

Suppression and the dynamic range of hearing.

The results from experiments that have examined intensity discrimination in the presence of notched noise indicate that spread of excitation is not necessary for the auditory system to maintain a large dynamic range. In those experiments the notched noise and the pedestal were simultaneously present. It is possible, therefore, that the notched noise suppressed the pedestal, and increased the dynamic range by reducing the excitation level [A. R. Palmer and E. F. Evans, Hear. Res. 7, 305-323 (1982)]. In the experiment described here, spread of excitation was masked nonsimultaneously in order to avoid suppressive effects. The brief sinusoidal pedestal was presented in a 13-ms gap between two bursts of a masking complex. The masking complex consisted of two sinusoids at frequencies of 0.8fc and 1.2fc (where fc was the pedestal frequency), each having a level either the same as, or 10 dB below the pedestal level, and a notched noise with a spectrum level 40 dB below the level of the sinusoids. Detection thresholds were measured to ensure that the complex was effective in masking spread of excitation. Weber fractions were measured at two pedestal frequencies, 1 and 4 kHz, and at eight pedestal levels at each frequency, covering a range of 70 dB. The results indicate that, although the masking complex raised the Weber fraction by up to 10 dB in some conditions, performance was no worse at high levels than at medium or low levels. This suggests that the auditory system can maintain a large dynamic range in the absence of suppression and spread of excitation.

Acoustic Stimulation↗

Speech recognition with dynamic range reduction: (1) deaf and normal subjects in laboratory conditions.

Processing to reduce the dynamic range of speech should increase intelligibility and protect the impaired ear from overloading. There are theoretical and practical objections to using AGC devices to reduce dynamic range. These are overcome by using recently available signal processing employing high frequency carrier clipping. An increase in intelligibility of speech with this HFCC has been demonstrated, for normal subjects with simulated deafness, and for most partially hearing patients. Intelligibility is not improved for some patients; possibly due to their having learned to extract features which are lost. These patients may also benefit after training.

Acoustics↗

Effects of galanin on wide-dynamic range neuron activity in the spinal dorsal horn of rats with sciatic nerve ligation.

Galanin is a 29-amino acid peptide with a suggested role in nociception. The effect of galanin on wide-dynamic range neuron discharge frequency in rats with nerve ligation, used as a model of neurogenic pain, was investigated by extracellular recording methods. Seven to 14 days after sciatic nerve ligation, 0.1, 0.5 or 1 nmol of galanin was administered directly on the dorsal surface of the L3-L5 spinal cord of rats with sciatic nerve ligation. It was found that galanin inhibited the activity of wide-dynamic range neurons dose-dependently, an effect was more pronounced in sciatic nerve ligated rats than intact rats. Furthermore, when 1 nmol of galantide, the galanin antagonist, was administered on the dorsal surface of the L3-L5 spinal cord, the wide-dynamic range neuron discharge frequency increased significantly. The results suggest that galanin plays an important role in the modulation of presumed nociception in mononeuropathy.

Animals↗

Enhancement of the dynamic range of the detected intensity in an optical measurement system by a three-channel technique.

When three-dimensional optical topometry of technical surfaces is performed, one major problem is that often the local reflectance of the object's surface varies within a wide range. This leads to overexposed and underexposed areas on the detector, where no measurements can be made. To overcome this problem, we have developed a method that extends the dynamic range of an imaging system. As an example we implemented this method to a measurement system that is based on fringe projection with a data projector and a color CCD camera. By projection of quasi-monochromatic fringes a different dynamic range in each of the three color channels of the camera is achieved. Hence the overall dynamic range of the system is increased by a factor larger than 5.

Journal Article↗

Patient experiences with multiband full dynamic range compression.

This investigation compared performance for 18 experienced hearing aid patients with a multiband full dynamic range compression hearing device and their previously worn linear or automatic gain control hearing aids. Performance was evaluated using a variety of clinical tests. These included functional gain and dynamic range measurements, speech recognition, and real ear measurements. Patients rated their performance with the multiband compression device and their previously worn aids on a rating scale pertaining to a variety of real life listening situations. Statistical analysis of data derived from test results shows significantly improved performance on all measures using the multiband compression aid over their conventional aids. Patients rated their performance higher with the compression instrument than with the conventional aids. Differences in performance on clinical tests and subjective patient responses appear to be related to the different signal processing schemes used in the two groups of devices.

Adolescent↗

Evaluation of inherent gray-level dynamic range in a digital image using the runs test and join-count statistics.

The dynamic range of the gray level of a digital image is limited by the noise it contains. Two statistical methods called "runs test" and "join-count statistic" are used to measure the noise level in a digital image. A residual image is formed by subtracting an original image from its smoothed version. Theoretically, the noise level in the residual image should be identical to that in the original image. The noise level is determined by examining each bit plane of the residual image individually starting from the least significant bit up to the bit plane whose statistic does not show a random pattern. Images from three digital modalities: computerized tomography, magnetic resonance, and computed radiography are used to evaluate the gray-level dynamic range. Both methods are easy to implement and fast to perform.

Biometry↗

Quality control of CGH: impact of metaphase chromosomes and the dynamic range of hybridization.

With the recent rapid expansion in the use of the comparative genomic hybridization (CGH) technique, increased attention to quality control is essential. In the present study, we show that despite optimization and standardization of metaphase preparation techniques and the commercial availability of metaphase spreads, batch-to-batch variability of the preparations remains a significant problem. To facilitate reliable CGH analysis despite this variability, we have developed a rapid denaturation test to assess the quality of the preparations without hybridization and quantitative image analysis criteria for assuring the day-to-day quality of CGH experiments, including sensitivity, specificity, and dynamic range. Monitoring the dynamic range of the hybridizations was found to be particularly critical for achieving sensitive and reliable CGH results. This reliability can be achieved, for example, by hybridization of a green-labeled normal male DNA against red-labeled female DNA and monitoring of the green:red ratio of the X chromosome in relation to that of the autosomes.

Chromosome Banding↗

ACTIVE-EYES: an adaptive pixel-by-pixel image-segmentation sensor architecture for high-dynamic-range hyperspectral imaging.

The ACTIVE-EYES (adaptive control for thermal imagers via electro-optic elements to yield an enhanced sensor) architecture, an adaptive image-segmentation and processing architecture, based on digital micromirror (DMD) array technology, is described. The concept provides efficient front-end processing of multispectral image data by adaptively segmenting and routing portions of the scene data concurrently to an imager and a spectrometer. The goal is to provide a large reduction in the amount of data required to be sensed in a multispectral imager by means of preprocessing the data to extract the most useful spatial and spectral information during detection. The DMD array provides the flexibility to perform a wide range of spatial and spectral analyses on the scene data. The spatial and spectral processing for different portions of the input scene can be tailored in real time to achieve a variety of preprocessing functions. Since the detected intensity of individual pixels may be controlled, the spatial image can be analyzed with gain varied on a pixel-by-pixel basis to enhance dynamic range. Coarse or fine spectral resolution can be achieved in the spectrometer by use of dynamically controllable or addressable dispersion elements. An experimental prototype, which demonstrated the segmentation between an imager and a grating spectrometer, was demonstrated and shown to achieve programmable pixelated intensity control. An information theoretic analysis of the dynamic-range control aspect was conducted to predict the performance enhancements that might be achieved with this architecture. The results indicate that, with a properly configured algorithm, the concept achieves the greatest relative information recovery from a detected image when the scene is made up of a relatively large area of moderate-dynamic-range pixels and a relatively smaller area of strong pixels that would tend to saturate a conventional sensor.

Journal Article↗

Limited dynamic range of immune response gene expression observed in healthy blood donors using RT-PCR.

The use of quantitative gene expression analysis for the diagnosis, prognosis, and monitoring of disease requires the ability to distinguish pathophysiological changes from natural variations. To characterize these variations in apparently healthy subjects, quantitative real-time PCR was used to measure various immune response genes in whole blood collected from blood bank donors. In a single-time-point study of 131 donors, of 48 target genes, 43 were consistently expressed and 34 followed approximately log-normal distribution. Most transcripts showed a limited dynamic range of expression across subjects. Specifically, 36 genes had standard deviations (SDs) of 0.44 to 0.79 cycle threshold (C(T)) units, corresponding to less than a 3-fold variation in expression. Separately, a longitudinal study of 8 healthy individuals demonstrated a total dynamic range (> 2 standard error units) of 2- to 4-fold in most genes. In contrast, a study of whole blood gene expression in 6 volunteers injected with LPS showed 15 genes changing in expression 10- to 90-fold within 2 to 5 h and returning to within normal range within 21 hours. This work demonstrates that (1) the dynamic range of expression of many immune response genes is limited among healthy subjects; (2) expression levels for most genes analyzed are approximately log-normally distributed; and (3) individuals exposed to an infusion of bacterial endotoxin (lipopolysaccharide), show gene expression profiles that can be readily distinguished from those of a healthy population. These results suggest that normal reference ranges can be established for gene expression assays, providing critical standards for the diagnosis and management of disease.

Adult↗

Cochlear mechanisms of frequency and intensity coding. II. Dynamic range and the code for loudness.

Our preceding paper described SPL-dependent changes in the shape of transfer functions recorded from inner and outer hair cells as well as supporting cells, in the 500-2500 Hz regions of the Mongolian gerbil cochlea. As SPL was increased, large shifts were observed in the peak of the transfer function. A strongly compressive nonlinearity was also observed at CF. This paper examines the data from the perspective of intensity coding in the auditory periphery. Based on the data, we offer a new explanation for the mechanisms underlying the different dynamic ranges of low and high threshold auditory neurons. We also find that, for pure tone stimuli, the growth of excitation at the characteristic place saturates rapidly, and cannot encode the wide dynamic range of loudness. The data are analyzed to explore other excitation pattern candidates for loudness coding. The growth of the peak of the IHC transfer function, as well as the growth of the response area, have been found to be linearly related to loudness growth over most of its dynamic range. Implications of the data for auditory intensity coding are discussed.

Animals↗

Dynamic range in terahertz time-domain transmission and reflection spectroscopy.

We present a quantitative method for identification of the dynamic range of the detectable absorption coefficient in the analysis of transmission terahertz (THz) time-domain spectroscopy data. In transmission measurements the largest detectable absorption coefficient is determined by the dynamic range of the THz signals, whereas in reflection measurements the largest detectable absorption coefficient is determined by the scan-to-scan reproducibility of the signal.

Journal Article↗

Analog filtering of large solvent signals for improved dynamic range in high-resolution NMR.

The large solvent signal from samples in H2O solvent still challenges the dynamic range capability of any spectrometer. The solvent signal can be largely removed with a pair of simple resistor-capacitor (RC) high-pass filters when the solvent frequency is set at center band (zero frequency) using quadrature detection, with RC approximately 0.5 ms. However, an approximately 0.5-ms transient remains at initial time, which we reduce fourfold for a short time only, just before the A/D converter, by means of a variable-gain amplifier, and later restore with software. This modification can result in a nearly fourfold increase in dynamic range. When we converted to a frequency-shifted mode (A. G. Redfield and S. D. Kunz, 1994, J. Magn. Reson. A 108, 234-237) we replaced the RC high-pass filter with a quadrature feedback notch filter tuned to the solvent frequency (5.06 kHz). This filter is an example of a class of two-input/two-output filters which maintain the spectral integrity (image-free character) of quadrature signals. Digital filters of the same type are also considered briefly. We discuss the implications of these ideas for spectrometer input design, including schemes for elimination of radiation damping, and effects of probe bandwidth on extreme oversampling.

Filtration↗

High dynamic range image rendering with a Retinex-based adaptive filter.

We propose a new method to render high dynamic range images that models global and local adaptation of the human visual system. Our method is based on the center-surround Retinex model. The novelties of our method is first to use an adaptive filter, whose shape follows the image high-contrast edges, thus reducing halo artifacts common to other methods. Second, only the luminance channel is processed, which is defined by the first component of a principal component analysis. Principal component analysis provides orthogonality between channels and thus reduces the chromatic changes caused by the modification of luminance. We show that our method efficiently renders high dynamic range images and we compare our results with the current state of the art.

Algorithms↗

Adaptive dynamic range optimization for cochlear implants: a preliminary study.

OBJECTIVE: The present study investigated the acceptability and the effect of Adaptive dynamic range optimization (ADRO) on speech perception for cochlear implant subjects. ADRO is a preprocessing scheme that continuously adjusts the gain in each frequency band to optimize the signal in the output dynamic range. DESIGN: Speech processor programs were created with and without ADRO processing. Nine subjects were tested in the laboratory and encouraged to use both programs in everyday listening situations. Take-home experience was assessed with preference questionnaires. Speech perception performance was compared for the standard and ADRO programs using City University of New York (CUNY) sentences, consonant-nucleus-consonant (CNC) words, and closed set spondees presented in quiet. A range of presentation levels were used; from 70 to 40 dB sound pressure level (unweighted RMS). CUNY sentences were also presented in multi-talker babble with +15 dB and +10 dB signal to noise ratios. RESULTS: There was a significant improvement in speech perception scores with the ADRO programs compared with the standard. At 50 dB, the mean open set sentence scores in quiet improved by 16% (p < 0.001). There was an improvement in mean word score for CNC words presented at 60 dB of 9.5% (p < 0.001) and a 20% improvement in mean score for spondees presented at 40 dB. There was no significant difference in sentence scores between the ADRO and the standard program for sentences presented in either noise condition. ADRO was the preferred program in 59% of listening situations, with five out of nine subjects indicating a strong overall preference and three subjects indicating a slight preference for ADRO. CONCLUSIONS: Continual adjustment of channel gains using ADRO provided improved sound quality and improved speech perception performance. Therefore, ADRO is a viable alternative to fixed channel gain and offers a means for cochlear implantees to gain more benefit from their devices.

Acoustic Stimulation↗

Desensitization of the GABAA receptor shifts the dynamic range of retinal horizontal cells due to light and dark adaptation.

The effects of the GABAergic pathway on the dynamic range of the light response of cone-driven horizontal cells (HCs) in the carp retina were investigated using conventional intracellular recordings and computer simulations. The amplitude of the HC responses to repetitive test flashes was altered by background illumination in control Ringer's solution, but was not changed following the application of picrotoxin or bicuculline, which suggests that GABAA receptors mediate the subsequent change in light response. This phenomenon was simulated by introducing the desensitization mechanism of the GABAA receptor into a cone-HC network model. These results suggest that desensitization of the GABAA receptor shifts the dynamic range of the HCs due to light and dark adaptation.

Adaptation, Ocular↗

Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(4). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reached with >95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p)>2...3).

Journal Article↗

Combinational use of antibody affinities in an immunoassay for extension of dynamic range and detection of multiple analytes.

Here, we describe the coordinated use of two antibodies with different affinities in a single immunoassay to extend the dynamic range and to enable detection of multiple analytes. The combination of dual antibodies was permitted with a flow-based assay at the antibody concentration below the dissociation constant, enabling affinity to govern the antibody-antigen binding. Both high and low affinity antibodies to estriol were used in combination to extend the range. The binding of each antibody was mutually independent and individually occurred over concentration ranges of 10 pM(-1) nM and 100 pM(-1) microM. The wide dynamic range of 10 pM(-1) microM was thus achieved as summation of the proportional signals to the total binding. When a combination of antibodies toward different antigens was used, it effectively detected multiple analytes within a mixture. In simultaneous analysis of a mixture of estradiol and estriol, the total signal was the sum of the binding signals from anti-estradiol and anti-estriol antibodies. In a further refinement, the individual antibodies were flowed through the flow cell sequentially, allowing the quantification of each binding signal within the combination. With this sequential format, measurement of the individual hormones in the range of 1.6 pM(-1) nM was shown. Furthermore, the same flow format was successfully applied to assay estriol and estradiol hormones in mixtures of six related compounds.

Antibodies↗