Aligned microcontact printing of micrometer-scale poly-L-lysine structures for controlled growth of cultured neurons on planar microelectrode arrays.

We describe a method for producing high-resolution chemical patterns on surfaces to control the attachment and growth of cultured neurons. Microcontact printing has been extended to allow the printing of micron-scale protein lines aligned to an underlying pattern of planar microelectrodes. Poly-L-lysine (PL) lines have been printed on the electrode array for electrical studies on cultured neural networks. Rat hippocampal neurons showed a high degree of attachment selectivity to the PL and produced neurites that faithfully grew onto the electrode recording sites.

Animals↗

A high-yield microassembly structure for three-dimensional microelectrode arrays.

This paper presents a practical microassembly process for three-dimensional (3-D) microelectrode arrays for recording and stimulation in the central nervous system (CNS). Orthogonal lead transfers between the micromachined two-dimensional probes and a cortical surface platform are formed by attaching gold beams on the probes to pads on the platform using wire-free ultrasonic bonding. The low-profile (150 microns) outrigger design of the probes allows the bonding of fully assembled high-density arrays. Micromachined assembly tools allow the formation of a full 3-D probe array within 30 min. Arrays having up to 8 x 16 shanks on 200-micron centers have been realized and used to record cortical single units successfully. Active 3-D probe arrays containing on-chip CMOS signal processing circuitry have also been created using the microassembly approach. In addition, a dynamic insertion technique has been explored to allow the implantation of high-density probe arrays into feline cortex at high-speed and with minimal traumatic injury.

Animals↗

Single-unit neural recording with active microelectrode arrays.

This paper discusses the single-unit recording characteristics of microelectrode arrays containing on-chip signal processing circuitry. Probes buffered using on-chip unity-gain operational amplifiers provide an output resistance of 200 ohm with an input-referred noise of 11-muV root-mean-square (rms) (100 Hz-10 kHz). Simultaneous in vivo recordings from single neurons using buffered and unbuffered (passive) iridium recording sites separated by less than 20 microm have shown that the use of on-chip circuitry does not significantly degrade system noise. Single-unit neural activity has also been studied using probes containing closed-loop preamplifiers having a voltage gain of 40 dB and a bandwidth of 13 kHz, and several input dc-baseline stabilization techniques have been evaluated. Low-noise in vivo recordings with a multiplexed probe have been demonstrated for the first time using an external asymmetrical clock running at 200 kHz. The multiplexed system adds less than 8-muV rms of noise to the recorded signals, suppressing the 5-V clock transitions to less than 2 ppm.

Animals↗

Modeled channel distributions explain extracellular recordings from cultured neurons sealed to microelectrodes.

Amplitudes and shapes of extracellular recordings from single neurons cultured on a substrate embedded microelectrode depend not only on the volume conducting properties of the neuron-electrode interface, but might also depend on the distribution of voltage-sensitive channels over the neuronal membrane. In this paper, finite-element modeling is used to quantify the effect of these channel distributions on the neuron-electrode contact. Slight accumulation or depletion of voltage-sensitive channels in the sealing membrane of the neuron results in various shapes and amplitudes of simulated extracellular recordings. However, estimation of channel-specific accumulation factors from extracellular recordings can be obstructed by co-occuring ion currents and defect sealing. Experimental data from cultured neuron-electrode interfaces suggest depletion of sodium channels and accumulation of potassium channels.

Action Potentials↗

Microelectrode array on folding polyimide ribbon for epidural mapping of functional evoked potentials.

This paper describes a flexible polyimide microelectrode ribbon with a bending structure for epidural recording. Bending the ribbon establishes good electro-mechanical contact of the electrodes to the cortex. Impedance spectroscopy and noise measurements in vitro were used to characterize the electrodes. Our in vivo experiments then successfully achieved synchronized neuronal activity and evoked potential patterns useful for understanding brain function and for finding cortical function.

Action Potentials↗

Geometry-based finite-element modeling of the electrical contact between a cultured neuron and a microelectrode.

The electrical contact between a substrate embedded microelectrode and a cultured neuron depends on the geometry of the neuron-electrode interface. Interpretation and improvement of these contacts requires proper modeling of all coupling mechanisms. In literature, it is common practice to model the neuron-electrode contact using lumped circuits in which large simplifications are made in the representation of the interface geometry. In this paper, the finite-element method is used to model the neuron-electrode interface, which permits numerical solutions for a variety of interface geometries. The simulation results offer detailed spatial and temporal information about the combined electrical behavior of extracellular volume, electrode-electrolyte interface and neuronal membrane.

Cell Membrane↗

A radio-telemetry system with a shape memory alloy microelectrode for neural recording of freely moving insects.

A radio frequency (RF) telemetry system with a shape memory alloy microelectrode was designed and fabricated. The total size and weight are 15 mm x 8 mm and 0.1 g, respectively. Since the telemeter is small and light enough to be loaded on a small animal such as an insect, the system can be used for the neural recording of a freely moving insect. The RF-telemeter can transmit signals by frequency modulation transmission at 80-90 MHz. The transmitted signals can be received up to about 16 meters away from the telemeter with a high signal-to-noise ratio. The neural activity can be detected without attenuation by using an instrumentation amplifier with its input impedance set to 2 Mohms at 1 kHz. The telemeter was loaded on a cockroach and the neural activity during a free-walk was successfully measured through this telemetry system.

Alloys↗

Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve.

We studied the consequences of long-term implantation of a penetrating microelectrode array in peripheral nerve over the time course of 4-6 mo. Electrode arrays without lead wires were implanted to test the ability of different containment systems to protect the array and nerve during contractions of surrounding muscles. Treadmill walking was monitored and the animals showed no functional deficits as a result of implantation. In a different set of experiments, electrodes with lead wires were implanted for up to 7 mo and the animals were tested at 2-4 week intervals at which time stimulation thresholds and recorded sensory activity were monitored for every electrode. It was shown that surgical technique highly affected the long-term stimulation results. Results between measurement sessions were compared, and in the best case, the stimulation properties stabilized in 80% of the electrodes over the course of the experiment (162 days). The recorded sensory signals, however, were not stable over time. A histological analysis performed on all implanted tissues indicated that the morphology and fiber density of the nerve around the electrodes were normal.

Action Potentials↗

Gold-coated microelectrode array with thiol linked self-assembled monolayers for engineering neuronal cultures.

We report the use of a gold coating on microelectrode arrays (MEAs) to enable the use of the relatively reliable surface modification chemistry afforded by alkanethiol self-assembled monolayers (SAMs). The concept is simple and begins with planar MEAs, which are commercially available for neuronal cell culture and for brain slice studies. A gold film, with an intermediate adhesive layer of titanium, is deposited over the insulation of an existing MEA in a manner so as to be thin enough for transmission light microscopy as well as to avoid electrical contact to the electrodes. The alkanethiol-based linking chemistry is then applied for the desired experimental purpose. Here we show that polylysine linked to alkanethiol SAM can control the geometry of an in vitro hippocampal neuronal network grown on the MEA. Furthermore, recordings of neuronal action potentials from random and patterned networks suggest that the gold coating does not significantly alter the electrode properties. This design scheme may be useful for increasing the number of neurons located in close proximity to the electrodes. Realization of in vitro neuronal circuits on MEAs may significantly benefit basic neuroscience studies, as well as provide the insight relevant to applications such as neural prostheses or cell-based biosensors. The gold coating technique makes it possible to use the rich set of thiol-based surface modification techniques in combination with MEA recording.

Action Potentials↗

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

An important aspect of the development of cortical prostheses is the enhancement of suitable implantable microelectrode arrays for chronic neural recording. The objective of this study was to investigate the recording performance of silicon-substrate micromachined probes in terms of reliability and signal quality. These probes were found to consistently and reliably provide high-quality spike recordings over extended periods of time lasting up to 127 days. In a consecutive series of ten rodents involving 14 implanted probes, 13/14 (93%) of the devices remained functional throughout the assessment period. More than 90% of the probe sites consistently recorded spike activity with signal-to-noise ratios sufficient for amplitudes and waveform-based discrimination. Histological analysis of the tissue surrounding the probes generally indicated the development of a stable interface sufficient for sustained electrical contact. The results of this study demonstrate that these planar silicon probes are suitable for long-term recording in the cerebral cortex and provide an effective platform technology foundation for microscale intracortical neural interfaces for use in humans.

Action Potentials↗

Easy-to-prepare assembly array of Tungsten microelectrodes.

This paper provides a detailed process flow for fabricating an easy-to-prepare, inexpensive, dense array of tungsten microelectrodes. We designed the process flow to minimize routine tasks by separating an initial preparation of a master mold from a routine preparation of substrate replication, array assembly and tip processing. Sandblast processing first produced a glass mold with a pattern of a series of protruding lines at a requested interval of a few hundred micrometers. Copying the groove pattern onto polystyrene mass-produced a replica substrate. Tungsten probes were then aligned on the substrate, and the tips of probes were finely processed in the block.

Action Potentials↗

Band-tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays.

Two thin-film microelectrode arrays with integrated circuitry have been developed for extracellular neural recording in behaving animals. An eight-site probe for simultaneous neural recording and stimulation has been designed that includes on-chip amplifiers that can be individually bypassed, allowing direct access to the iridium sites for electrical stimulation. The on-probe amplifiers have a gain of 38.9 dB, an upper-cutoff frequency of 9.9 kHz, and an input-referred noise of 9.2 microV rms integrated from 100 Hz to 10 kHz. The low-frequency cutoff of the amplifier is tunable to allow the recording of field potentials and minimize stimulus artifact. The amplifier consumes 68 microW from +/- 1.5 V supplies and occupies 0.177 mm2 in 3 microm features. In vivo recordings have shown that the preamplifiers can record single-unit activity 1 ms after the onset of stimulation on sites as close as 20 microm to the stimulating electrode. A second neural recording array has been developed which multiplexes 32 neural signals onto four output data leads. Providing gain on this array eliminates the need for bulky headmounted circuitry and reduces motion artifacts. The time-division multiplexing circuitry has crosstalk between consecutive channels of less than 6% at a sample rate of 20 kHz per channel. Amplified, time-division-multiplexed multichannel neural recording allows the large-scale recording of neuronal activity in freely behaving small animals with minimum number of interconnect leads.

Action Potentials↗

In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes.

The charge-injection limits of activated iridium oxide electrodes (AIROF) and PtIr microelectrodes with similar geometric area and shape have been compared in vitro using a stimulation waveform that delivers cathodal current pulses with current-limited control of the electrode bias potential in the interpulse period. Charge-injection limits were compared over a bias range of 0.1-0.7 V (versus Ag/AgCl) and pulse frequencies of 20, 50, and 100 Hz. The AIROF was capable of injecting between 4 and 10 times the charge of the PtIr electrode, with a maximum value of 3.9 mC/cm2 obtained at a 0.7 V bias and 20 Hz frequency.

Electric Impedance↗

In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex.

The mechanical behavior of an electrode during implantation into neural tissue can have a profound effect on the neural connections and signaling that takes place within the tissue. The objective of the present work was to investigate the in vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays recently developed by the VSAMUEL consortium (European Union, grant #IST-1999-10073). We have previously reported on both the electrical [1]-[3] and mechanical [4], [5] properties of the ACREO electrodes. In this paper, the tensile and compression forces were measured during a series of in vivo electrode insertions into the cerebral cortex of rats (7 acute experiments, 2-mm implant depth, 2-mm/s insertion velocity). We compared the ACREO silicon electrodes (40 opening angle, 1-8 shafts) to single-shaft tungsten electrodes (3 degrees and 10 degrees opening angles). The penetration force and dimpling increased with the cross-sectional area (statistical difference between the largest and the smallest electrode) and with the number of shafts (no statistical difference). We consistently observed tensile (drag) forces during the retraction phase, which indicates the brain tissue sticks to the electrode within a short time period. Treating the electrodes prior to insertion with silane (hydrophobic) or piranha (hydrophilic) significantly decreased the penetration force. In conclusion, our findings suggest that reusable electrodes for acute animal experiments must not only be strong enough to survive a maximal force that exceeded the penetration force, but must also be able to withstand high tension forces during retraction. Careful cleaning is not only important to avoid foreign body response, but can also reduce the stress applied to the electrode while penetrating the brain tissue.

Action Potentials↗

Hydration characteristics and electrical resistivity of stratum corneum using a noninvasive four-point microelectrode method.

We have used a four-microelectrode probe to study the relationship between electrical resistivity (p), water content (wf) water binding, and electrolyte levels in samples of plantar stratum corneum. Untreated samples characteristically showed an exponential relationship between log p and wf. This characteristic was retained but altered quantitatively by factors which increase and decrease the ratio of bound to unbound water, by lipid extraction, and (following extraction) by electrolyte presoak. The theoretical aspects of obtaining similar data from intact stratum corneum are discussed.

Body Water↗

Substance identification by quantitative characterization of oscillatory activity in murine spinal cord networks on microelectrode arrays.

This paper presents a novel and comprehensive method to identify substances on the basis of electrical activity and is a substantial improvement for drug screening. The spontaneous activity of primary neuronal networks is influenced by neurotransmitters, ligands, and other substances in a similar fashion as known from in vivo pharmacology. However, quantitative methods for the identification of substances through their characteristic effects on network activity states have not yet been reported. We approached this problem by creating a database including native activity and five drug-induced oscillatory activity states from extracellular multisite recordings from microelectrode arrays. The response profiles consisted of 30 activity features derived from the temporal distribution of action potentials, integrated burst properties, calculated coefficients of variation, and features of Gabor fits to autocorrelograms. The different oscillatory states were induced by blocking neurotransmitter receptors for: (i) GABA(A); (ii) glycine; (iii) GABA(A) and glycine; (iv) all major synaptic types except AMPA, and (v) all major synapses except NMDA. To test the identification capability of the six substance-specific response profiles, five blind experiments were performed. The response features from the unknown substances were compared to the database using proximity measures using the normalized Euclidian distance to each activity state. This process created six identification coefficients where the smallest correctly identified the unknown substances. Such activity profiles are expected to become substance-specific 'finger prints' that classify unique responses to known and unknown substances. It is anticipated that this kind of approach will help to quantify pharmacological responses of networks used as biosensors.

Action Potentials↗

Cochlear potentials of the pigeon inner ear recorded with microelectrodes.

The CM-intensity function (i.e. the relation between the amplitude of the cochlear potential (CM) and the sound pressure level) of the avian ear has previously been shown to deviate from the mammalian ear with respect to the slope of the linear part of the function. The lower slope values found in the perilymphatic space of the avian ear have been interpreted to indicate a damping influence of the tegmentum vasculosum on the mechanical vibration of the basilar membrane. In this study the CM-intensity function has been examined on either side of the tegmentum vasculosum of the pigeon ear using microelectrode technique. The slope of the linear part of the CM-intensity function in scala vestibuli was found to be a function of the sound frequency approaching unity at higher frequencies. In ductus cochlearis the slope of the linear part of the CM-intensity function was close to unity at most frequencies except the best frequency for the electrode position. At this frequency (3-4 kHz) the slope value was low. These findings from the ductus cochlearis are similar to findings in scala media of the mammalian ear. Thus the influence of tegmentum vasculosum on CM in scala vestibuli may be due to passive electrical properties of the tissue and not to the mechanical vibration of the basilar membrane.

Action Potentials↗

Microelectrode ion and O2 fluxes measurements reveal differential sensitivity of barley root tissues to hypoxia.

Hypoxia-induced changes in net H+, K+ and O2 fluxes across the plasma membrane (PM) of epidermal root cells were measured using the non-invasive microelectrode ion flux measurement (MIFE) system in elongation, meristem and mature root zones of two barley (Hordeum vulgare L.) varieties contrasting in their waterlogging (WL) tolerance. The ultimate goal of this study was to shed light on the mechanisms underlying effects of WL on plant nutrient acquisition and mechanisms of WL tolerance in barley. Our measurements revealed that functionally different barley root zones have rather different O2 requirements, with the highest O2 influx being in the elongation zone of the root at about 1 mm from the tip. Oxygen deprivation has qualitatively different effects on the activity of PM ion transporters in mature and elongation zones. In the mature zone, hypoxic treatment caused a very sharp decline in K+ uptake in the WL sensitive variety Naso Nijo, but did not reduce K+ influx in the WL tolerant TX9425 variety. In the elongation zone, onset of hypoxia enhanced K+ uptake from roots of both cultivars. Pharmacological experiments suggested that hypoxia-induced K+ flux responses are likely to be mediated by both K(+) -inward- (KIR) and non-selective cation channels (NSCC) in the elongation zone, while in the mature zone K(+) -outward- (KOR) channels are the key contributors. Overall, our results suggest that oxygen deprivation has an immediate and substantial effect on root ion flux patterns, and that this effect is different in WL-sensitive and WL-tolerant cultivars. To what extent this difference in ion flux response to hypoxia is a factor conferring WL tolerance in barley remains to be answered in future studies.

Biological Transport↗