PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40Linked to original sources

Simultaneous observation of enzyme surface diffusion and surface reaction using microfluidic patterning of substrate surfaces.

We present a study of the simultaneous observation of protease reaction and surface diffusion as the enzyme interacts with a model substrate surface. We use micro-fluidic patterning to decorate a bovine serum albumin substrate surface with stripes of adsorbed enzyme in the absence of physical barriers. Spreading of the enzyme from the initial striped region indicates surface diffusion, while removal of the substrate provides a measure of reactivity. Microfluidic patterning provides a means to determine the relative importance of enzyme adsorption, surface diffusion, and reaction on the rate of substrate removal.

Animals↗

Multistage isoelectric focusing in a polymeric microfluidic chip.

This paper reports a protocol that improves the resolving power of isoelectric focusing (IEF) in a polymeric microfluidic chip. This method couples several stages of IEF in series by first focusing proteins in a straight channel using broad-range ampholytes and then refocusing segments of the first channel into secondary channels that branch from the first one at T-junctions. Experiments demonstrate that several fluorescent proteins that had focused within a segment of the straight channel in the first stage were refocused at significantly higher resolution due to the shallower pH gradient and higher electrical field gradient. Two variants of green fluorescent protein from the second-stage IEF fractionation were further separated in a third stage. Three stages of IEF were completed in less than 25 min at electric field strengths ranging from 50 to 214 V/cm.

Dimethylpolysiloxanes↗

Microfluidic biosensor for the serotype-specific detection of dengue virus RNA.

The development of a microfluidic biosensor with fluorescence detection for the rapid, sensitive, and serotype-specific detection of Dengue virus is presented. The biosensor chip consists of poly(dimethylsiloxane) (PDMS) substrate with fabricated microchannels and a glass substrate used to seal the microchannels. These two substrates are packaged within a pressure-closed Plexiglas housing to provide a watertight reversible sealing at the PDMS-glass interface. The ability to reversibly seal the device permits easy disassembly and quick interchange of the device parts, which is ideal for developmental purposes. The biosensor employs a magnetic bead-based sandwich hybridization system in conjugation with liposome amplification for the specific detection of nucleic acids. The concentrations of the various biosensor components were optimized using a synthesized fragment of Dengue virus RNA. To evaluate the sensitivity of the assay, two detection systems, based on fluorescence measurements of intact and lysed liposomes, were analyzed. The entire analysis was complete within 20 min (including incubation time) with RNA detection limits of 0.125 nM and 50 pM for intact and lysed liposome detection systems, respectively. Subsequently, the biosensor was applied to the analysis of actual RNA obtained from Dengue virus serotypes 1-4. The resulting signals were compared to those obtained using standard electrochemiluminescence detection and shown to correspond perfectly with respect to serotype identification.

Base Sequence↗

Microfluidic electrocapture for separation of peptides.

A separation method based on electroimmobilization and sequential release of captured molecules is reported. A microfluidic electrocapture device is utilized to immobilize peptides in a microflow stream. After capture, the electric field is decreased in a stepwise manner, causing sequential release of the captured peptides according to their electrophoretic mobility. Tryptic peptides were separated and analyzed by matrix-assisted laser desorption/ionization mass spectrometry. The separation power was high enough to increase the ionization yield of several peptides not seen in the unprocessed sample. In addition to separation, simultaneous sample cleanup was demonstrated for peptides obtained by shotgun tryptic digestion of membrane protein extracts.

Amino Acid Sequence↗

Microfluidic device for electric field-driven single-cell capture and activation.

A microchip that performs directed capture and chemical activation of surface-modified single cells has been developed. The cell capture system is comprised of interdigitated gold electrodes microfabricated on a glass substrate within PDMS channels. The cell surface is labeled with thiol functional groups using endogenous RGD receptors, and adhesion to exposed gold pads on the electrodes is directed by applying a driving electric potential. Multiple cell types can thus be sequentially and selectively captured on desired electrodes. Single-cell capture efficiency is optimized by varying the duration of field application. Maximum single-cell capture is attained for the 10-min trial, with 63 +/- 9% (n = 30) of the electrode pad rows having a single cell. In activation studies, single M1WT3 CHO cells loaded with the calcium-sensitive dye fluo-4 AM were captured; exposure to the muscarinic agonist carbachol increased the fluorescence to 220 +/- 74% (n = 79) of the original intensity. These results demonstrate the ability to direct the adhesion of selected living single cells on electrodes in a microfluidic device and to analyze their response to chemical stimuli.

Animals↗

Microfluidic electrophoresis chip coupled to microdialysis for in vivo monitoring of amino acid neurotransmitters.

Microfluidic electrophoresis devices were coupled on-line to microdialysis for in vivo monitoring of primary amine neurotransmitters in rat brain. The devices contained a sample introduction channel for dialysate, a precolumn reactor for derivatization with o-phthaldialdehyde, a flow-gated injector, and a separation channel. Detection was performed using confocal laser-induced fluorescence. In vitro testing revealed that the initial device design had detection limits for amino acids of approximately 200 nM, relative standard deviation of peak heights of 2%, and separations within 95 s with up to 30,200 theoretical plates when applying an electric field of 370 V/cm. A second device design that allowed electric fields of 1320 V/cm to be applied while preserving the reaction time allowed separations within 20 s with up to 156,000 theoretical plates. Flow splitting into the electrokinetic network from hydrodynamic flow in the sample introduction channel was made negligible for sampling flow rates from 0.3 to 1.2 microL/min by placing a 360-microm-diameter fluidic access hole that had flow resistance (0.15-7.2) x 10(8)-fold lower than that of the electrokinetic network at the junction of the sample introduction channel and the electrokinetic network. Using serial injections, the device allowed the dialysate stream to be analyzed at 130-s intervals. In vivo monitoring was demonstrated by using the microdialysis/microfluidic device to record glutamate concentrations in the striatum of an anesthetized rat during infusion of the glutamate uptake inhibitor l-trans-pyrrolidine-2,4-dicarboxylic acid. These results prove the feasibility of using a microfabricated fluidic system coupled to sampling probes for chemical monitoring of complex media such as mammalian brain.

Amino Acids↗

Direct writing of metal nanoparticle films inside sealed microfluidic channels.

Herein we demonstrate the ability to pattern Ag nanoparticle films of arbitrary geometry inside sealed PDMS/TiO2/glass microfluidic devices. The technique can be employed with aqueous solutions at room temperature under mild conditions. A 6 nm TiO2 film is first deposited onto a planar Pyrex or silica substrate, which is subsequently bonded to a PDMS mold. UV light is then exposed through the device to reduce Ag+ from an aqueous solution to create a monolayer-thick film of Ag nanoparticles. We demonstrate that this on-chip deposition method can be exploited in a parallel fashion to synthesize nanoparticles of varying size by independently controlling the solution conditions in each microchannel in which the film is formed. The film morphology was checked by atomic force microscopy, and the results showed that the size of the nanoparticles was sensitive to solution pH. Additionally, we illustrate the ability to biofunctionalize these films with ligands for protein capture. The results indicated that this could be done with good discrimination between addressed locations and background. The technique appears to be quite general, and films of Pd, Cu, and Au could also be patterned.

Coated Materials, Biocompatible↗

Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics.

A polymeric microfluidic device for solid-phase extraction (SPE)-based isolation of nucleic acids is demonstrated. The plastic chip can function as a disposable sample preparation system for different biological and diagnostic applications. The chip was fabricated in a cyclic polyolefin by hot-embossing with a master mold. The solid phase consisted of a porous monolithic polymer column impregnated with silica particles. The extraction was achieved due to the binding of nucleic acids to the silica particles in the monolith. The solid phase was formed within the channels of the device by in situ photoinitiated polymerization of a mixture of methacrylate and dimethacrylate monomers, UV-sensitive free-radical initiator, and porogenic solvents. The channel surfaces were pretreated via photografting to covalently attach the monolith to the channel walls. The solid phase prepared by this method allowed for successful extraction and elution of nucleic acids in the polymeric microchip.

Combinatorial Chemistry Techniques↗

A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples.

A glass microdevice has been constructed for the on-line integration of solid-phase extraction (SPE) of DNA and polymerase chain reaction (PCR) on a single chip. The chromatography required for SPE in the microfluidic sample preparation device (muSPD) was carried out in a silica bead/sol-gel SPE bed, where the purified DNA was eluted directly into a downstream chamber where conventional thermocycling allowed for PCR amplification of specific DNA target sequences. Through rapid, simple passivation of the PCR chamber with a silanizing reagent, reproducible DNA extraction and amplification was demonstrated from complex biological matrixes in a manner amenable to any research laboratory, using only a syringe pump and a conventional thermocycler. The muSPD allowed for SPE concentration of DNA from 600 nL of blood coupled to subsequent on-chip amplification that yielded a detectable amplicon; this simple device can be applied to a variety of routine genetic analyses without the need for sophisticated instrumentation. In addition, the applicability of these developments to nonconventional thermocycling was demonstrated through the use of noncontact, IR-mediated heating. This was exemplified with the isolation of DNA from an anthrax spore-spiked nasal swab and the subsequent on-chip amplification of target DNA sequences in a total processing time of only 25 min.

DNA↗

Universal microfluidic gradient generator.

The study of cellular responses to chemical gradients in vitro would greatly benefit from experimental systems that can generate precise and stable gradients comparable to chemical nonhomogeneities occurring in vivo. Recently, microfluidic devices have been demonstrated for linear gradient generation for biological applications with unmatched accuracy and stability. However, no systematic approach exists at this time for generating other gradients of target spatial configuration. Here we demonstrate experimentally and provide mathematical proof for a systematic approach to generating stable gradients of any profile by the controlled mixing of two starting solutions.

Microfluidics↗

Optimization of a microfluidic mixer for studying protein folding kinetics.

We have applied an optimization method in conjunction with numerical simulations to minimize the mixing time of a microfluidic mixer developed for protein folding studies. The optimization method uses a semideterministic algorithm to find the global minimum of the mixing time by varying the mixer geometry and flow conditions. We describe the minimization problem and constraints and give a brief overview of the optimization algorithm. We present results of the optimization, including the optimized geometry and parameter sensitivities, and we demonstrate the improvement in mixing performance with experiments using microfabricated mixers. The dye-quenching experiments of the original and optimized mixer designs show respective mixing times of 7 and 4 mus, a 40% reduction. The new design also provides more uniform mixing across streamlines that enter the mixer. The optimized mixer is the fastest reported continuous flow mixer for protein folding.

Kinetics↗

Microfluidic single-cell mRNA isolation and analysis.

Single-cell gene expression analysis holds great promise for studying diverse biological systems, but methodology to process these precious samples in a reproducible, quantitative, and parallel fashion remains challenging. Here, we utilize microfluidics to isolate picogram and subpicogram mRNA templates, as well as to synthesize cDNA from these templates. We demonstrate single-cell mRNA isolation and cDNA synthesis, provide quantitative calibrations for each step in the process, and measure gene expression in individual cells. The techniques presented here form the foundation for highly parallel single-cell gene expression studies.

Animals↗

Chemotaxis assays of mouse sperm on microfluidic devices.

Sperm chemotaxis is an area of significant interest to scientists involved in reproductive science. Understanding how and when sperm cells are attracted to the egg could have profound effects on reproduction and contraception. In an effort to systematically study this problem, we have fabricated and evaluated a microfluidic device to measure sperm chemotaxis. The device was designed with a flow-through configuration using a spatially and temporally stable chemical gradient. Mouse sperm cells were introduced into the chemotaxis chamber between confluent flows of mouse ovary extract and buffer. The sperm experiencing chemotaxis swam toward the extract and were counted relative to those that swam toward the buffer. The ovary extracts were diluted from 10(2) to 10(7) times, and each extract dilution was screened for chemotaxis. Four out of six ovaries showed a strong chemotactic response at extract dilutions of 10(-3) to 10(-5). This device provided a convenient, disposable platform on which to conduct chemotaxis assays, and the flow-through design overcomes difficulties associated with distinguishing chemotaxis from trapping.

Animals↗

Separation of plasma from whole human blood in a continuous cross-flow in a molded microfluidic device.

We designed, fabricated, and tested a microfluidic device for separation of plasma from whole human blood by size exclusion in a cross-flow. The device is made of a single mold of a silicone elastomer poly(dimethylsiloxane) (PDMS) sealed with a cover glass and is essentially disposable. When loaded with blood diluted to 20% hematocrit and driven with pulsatile pressure to prevent clogging of the channels with blood cells, the device can operate for at least 1 h, extracting approximately 8% of blood volume as plasma at an average rate of 0.65 microL/min. The flow in the device causes very little hemolysis; the extracted plasma meets the standards for common assays and is delivered to the device outlet approximately 30 s after injection of blood to the inlet. Integration of the cross-flow microchannel array with on-chip assay elements would create a microanalysis system for point-of-care diagnostics, reducing costs, turn-around times, and volumes of blood sample and reagents required for the assays.

Female↗

Achieving uniform mixing in a microfluidic device: hydrodynamic focusing prior to mixing.

We describe a microfluidic mixer that is well-suited for kinetic studies of macromolecular conformational change under a broad range of experimental conditions. The mixer exploits hydrodynamic focusing to create a thin jet containing the macromolecules of interest. Kinetic reactions are triggered by molecular diffusion into the jet from adjacent flow layers. The ultimate time resolution of these devices can be restricted by premature contact between co-flowing solutions during the focusing process. Here, we describe the design and characterization of a mixer in which hydrodynamic focusing is decoupled from the diffusion of reactants, so that the focusing region is free from undesirable contact between the reactants. Uniform mixing on the microsecond time scale is demonstrated using a device fabricated by imprinting optical-grade plastic. Device characterization is carried out using fluorescence correlation spectroscopy (FCS) and two-photon microscopy to measure flow speeds and to quantify diffusive mixing by monitoring the collisional fluorescence quenching, respectively. Criteria for achieving microsecond time resolution are described and modeled.

Microfluidics↗

Screening of protein crystallization conditions on a microfluidic chip using nanoliter-size droplets.

Protein crystallization is a major bottleneck in determining tertiary protein structures from genomic sequence data. This paper describes a microfluidic system for screening hundreds of protein crystallization conditions using less than 4 nL of protein solution for each crystallization droplet. The droplets are formed by mixing protein, precipitant, and additive stock solutions in variable ratios in a flow of water-immiscible fluids inside microchannels. Each droplet represents a discrete trial testing different conditions. The system has been validated by crystallization of several water-soluble proteins.

Crystallization↗

Combining microfluidic networks and peptide arrays for multi-enzyme assays.

This paper reports the use of microfluidic networks (muFNs) to both prepare peptide microarrays and carry out label-free enzyme assays on self-assembled monolayers (SAMs) of alkanethiolates on gold. A poly(dimethylsiloxane) (PDMS) stamp fabricated with microchannels is used to immobilize a linear array of cysteine-terminated peptides onto SAMs presenting maleimide groups. The stamp is then reapplied to the SAM in a perpendicular direction to introduce enzyme solutions so that each solution can interact with an identical linear array of immobilized peptides. The muFNs enable multiple enzyme-substrate interactions to be simultaneously evaluated at a submicroliter scale, while the use of SAMs enables the use of MALDI mass spectrometry (MS) to analyze the enzyme activities. This paper demonstrates applications of this system for assaying multiple kinases and for profiling the activities of kinases and phosphatases in human K562 cell extracts. The combination of muFN, SAMs, and MS detection provides a flexible platform for assaying enzyme activities in biological samples.

Amino Acid Sequence↗

High-temperature microfluidic synthesis of CdSe nanocrystals in nanoliter droplets.

The high-temperature synthesis of CdSe nanocrystals in nanoliter-volume droplets flowing in a perfluorinated carrier fluid through a microfabricated reactor is presented. A flow-focusing nanojet structure with a step increase in channel height reproducibly generated octadecene droplets in Fomblin Y 06/6 perfluorinated polyether at capillary numbers up to 0.81 and with a droplet:carrier fluid viscosity ratio of 0.035. Cadmium and selenium precursors flowing in octadecene droplets through a high-temperature (240-300 degrees C) glass microreactor produced high-quality CdSe nanocrystals, as verified by optical spectroscopy and transmission electron microscopy. Isolating the reaction solution in droplets prevented particle deposition and hydrodynamic dispersion, allowing the reproducible synthesis of nanocrystals at three different temperatures and four different residence times in the span of 4 h. Our synthesis of a wide range of nanocrystals at high temperatures, high capillary numbers, and low viscosity ratio illustrates the general utility of droplet-based microfluidic reactors to encapsulate nanoliter volumes of organic or aqueous solutions and to precisely control chemical or biochemical reactions.

Cadmium Compounds↗