PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Effect of storage in flour and of particle size on the bioavailability of elemental iron powders for rats and humans.

Elemental iron powders produced by different processes were separated by nitrogen elutriation into fractions based on particle size. The fractions containing fine particles (7-10 micrometer) of electrolytic iron, hydrogen (H2)- and carbon monoxide (CO)-reduced iron, and the whole sample of carbonyl iron (92% less than 11 micrometer) were blended into freshly milled wheat flour and stored at about 21 degrees C. Storing the enriched flour up to 9 months had no effect on the relative biological value (RBV) of iron for rats from each type of iron supplement. Baking bread with flour containing electrolytic, H2-reduced, and carbonyl iron after storage for 10 months also had no effect on the RBV of the iron powders. There was no change in the RBV of iron for rats from flour enriched with electrolytic iron (200 mg/kg) and ascorbic acid (200 and 1665 mg/kg flour) after storage for 1 week and 3 months. The decreases in RBV due to increase in size of particles (7-10 vs. 20-26 micrometer) were significant for H2-reduced iron and CO-reduced iron but not for electrolytic iron and carbonyl iron. The RBVs of elemental iron powders for rats were similar to the values obtained with humans, based on iron absorption after an overnight fast.

Animals↗

Relationships between the effective interparticulate contact area and the tensile strength of tablets of amorphous and crystalline lactose of varying particle size.

The aim of this study was to experimentally evaluate an equation for describing tablet tensile strength by studying relationships between the measured tensile strength and the calculated effective interparticulate contact area in tablets prepared from varying size fractions of amorphous and crystalline lactose at varying pressures. Amorphous lactose produced tablets of higher tensile strength than crystalline lactose and there was a tendency for reduced particle size to increase tablet strength. The tablet tensile strength correlated reasonably well with the effective area of contact for each material after compensation for a particle size-related intercept. It was thus concluded that the tensile strength equation under investigation reflects a structural property of the tablet which correlates with the tensile strength of the tablet. The slope of the tensile strength-contact area relationship differed between the materials and original particle size also had a small effect on this parameter. The results indicate thus also that the differences in compactability between amorphous and crystalline lactose are mainly the result of differences in bonding capacity, although differences in particle deformability also play a limited part.

Chemistry, Pharmaceutical↗

Particle size does not affect the rate of intracellular routing for ligands internalized by non-adsorptive pinocytosis.

The rate at which three different species of a fluid phase marker (horseradish peroxidase) reached the lysosomal compartment of mouse LM fibroblasts was compared. Initial observations suggested that the rate was a function of particle size. Adjustment of the concentrations of the various species of HRP to equal numbers of physical particles negated the apparent affect. Thus, particle size does not affect the intracellular routing of a ligand entering fibroblasts by non-adsorptive pinocytosis.

Animals↗

Randomized trials describing lung inflammation after pleurodesis with talc of varying particle size.

We report two trials describing whether talc pleurodesis with a mean particle size of less than 15 microm ("mixed" talc) produces more lung and systemic inflammation than tetracycline or "graded" talc (most particles < 10 microm were removed). First, 20 patients with malignant effusions received tetracycline or mixed talc. Changes in lung and systemic inflammation from lung clearance scans, oxygen saturations, and C-reactive protein from baseline to 48 hours after pleurodesis were recorded. Lung inflammation (change in isotope clearance, talc -9.26, SD 14.3 vs. tetracycline 4.10, SD 13.8 minutes; difference = -13.4; 95% confidence interval [CI], -26.6 to -0.2; p = 0.05) and systemic inflammation (change in C-reactive protein, talc 198 SD 79.2 vs. tetracycline 74 SD 79.4 microg/L; difference = 124; 95% CI, 50 to 199; p = 0.004) were greater after talc. Second, 48 patients received mixed or graded talc, and gas exchange was assessed from changes in the alveolar-arterial oxygen gradient. Mixed talc worsened gas exchange (oxygen gradient change, mixed 2.17 SD 1.74 kPa, 16.3 13.1 mm Hg vs. graded 0.72 SD 2.46 kPa 5.4 18.5 mm Hg, difference = 1.45; 95% CI, 0.2 to 2.7; p = 0.03) and induced more systemic inflammation than graded talc. We conclude that the routine use of graded talc for pleurodesis would reduce the morbidity of this procedure.

Blood Gas Analysis↗

A new approach to sampling for particle size and chemical species "fingerprinting" of workplace aerosols.

A commercially-available, high-volume (28.3 Lpm) Andersen-type cascade impactor was modified in order to extend its operational range further into the range of large inhalable particles for purposes of use in an exposure assessment study in the primary nickel production industry. The modification involved incorporating a 10-ppi (pores per inch) porous plastic foam top stage that has a wide penetration curve with a (50)d(ae)-value of approximately 27 microm. This enabled the upper end of the range of the instrument to be extended from about 10 to greater than 70 microm. The inlet of the original instrument was also modified to incorporate the new top stage and provide "representative" aspiration of total airborne particulate with an efficiency of close to 100% over the range of aerodynamic particle sizes of interest. A mathematical inversion algorithm developed in earlier research was modified so that it could be applied to this new instrument. This enabled raw data on particulate material recovered from all stages of the instrument (including the new porous foam top stage) to be used for the determination of continuous particle size distributions, as well as chemical speciation, over the inhalable range. The new instrument was deployed in a pilot field study in the nickel primary production industry by which to demonstrate the potential of the new instrument for generating useful information pertaining to health-relevant aerosol size tractions (e.g., inhalable, thoracic, and respirable), and for soluble, sulphidic, metallic, oxidic and total nickel chemical species groups.

Aerosols↗

Particle size distribution analysis as a rapid method to detect significant bacteriuria.

Particle size distribution analysis (PSDA) was evaluated as a rapid screening method for detecting significant bacteriuria by linking a C1000 Channelyzer to a Coulter Counter. Colony counts and PSDA screening results were compared for 800 urine specimens. The PSDA method proved to be 92% specific, but only 64% sensitive, for detecting at least 10(5) colony forming units (CFU)/ml. By performing serial dilution colony counts on 109 culture-positive specimens (greater than or equal to 10(5) CFU/ml), it was determined that the low level of sensitivity (64%) was due to culture-positive specimens that had between 10(5) and less than 10(7) CFU/ml. The sensitivity of the PSDA method increased to 90% and 100% when culture-positive specimens had 10(7) or more and 10(8) or more CFU/ml, respectively. The low level of sensitivity demonstrated in this investigation makes the introduction of this method into clinical usage unacceptable at this time.

Bacteriuria↗

LDL particle size and LDL and HDL cholesterol changes with dietary fat and cholesterol in healthy subjects.

We have conducted a dietary trial in 54 men and 51 women with a wide range of fasting cholesterol values to examine the use of low density lipoprotein (LDL) particle size to predict the lipoprotein response to dietary fat and cholesterol. After a 2-week low fat period, subjects were given two liquid supplements in addition to their low fat diet for 3 weeks each, one containing 31-40 g of fat and 650-845 mg of cholesterol, the other fat free. LDL particle type was determined by 3-15% gradient gel electrophoresis. On multiple regression, LDL type was independently related to plasma triglyceride (P < 0.001), waist circumference (P < 0.01), and high density lipoprotein (HDL) (P < 0.001) accounting for 56% of the variance in LDL type in the whole group. Change in LDL cholesterol with dietary fat and cholesterol was unrelated to LDL particle size in either men or women. However, change in HDL cholesterol in men was strongly related to LDL particle type (r = -0.52, P = 0.001) and change in HDL2 cholesterol in women was related to LDL particle type (r = -0.40, P < 0.01). In conclusion, we are unable to confirm the finding that LDL particle type can predict changes in LDL cholesterol following changes in dietary fat intake. However, LDL particle type can independently predict changes in HDL cholesterol in men and accounts for 27% of the variance.

Adult↗

Effect of exercise and menstrual cycle status on plasma lipids, low density lipoprotein particle size, and apolipoproteins.

Habitual physical exercise has been reported to have beneficial effects on plasma lipoproteins. To examine this question in women, plasma cholesterol, triglyceride, and apolipoprotein (apo) A-I and B levels, and low density lipoprotein (LDL) particle size were determined in 25 women runners (9 of whom had exercise-related secondary amenorrhea) and 36 age-matched nonexercising women (controls). The eumenorrheic runners had significantly lower apo B levels and significantly greater mean apo A-I/apo B ratios and LDL particle sizes than did the control women (P less than 0.05). Lower apo B levels were correlated with decreased body mass index, a known exercise effect (P less than 0.0001). In addition, normally menstruating runners had cholesterol and triglyceride levels that were 7.6% and 25.4% lower, respectively, and apo A-I levels that were 6.4% higher than control women (P = NS). In amenorrheic runners all parameters were similar to values in control women, except that apo B levels were 20% lower (P less than 0.05). Amenorrheic runners had lower plasma apo A-I levels (13%) and significantly lower apo A-I/apo B ratios and estradiol levels than eumenorrheic runners, and serum estradiol values in the runners were correlated with apo A-I levels (P less than 0.01). These data indicate that the beneficial effects of strenuous exercise on plasma apo A-I levels and apo A-I/apo B ratios in women runners can be reversed by exercise-induced amenorrhea and decreased serum estradiol levels, and that women runners have lower apo B levels than nonexercising women, regardless of menstrual status.

Adult↗

Effect of Particle Size Distribution on the Rheology of Dispersed Systems.

The rheological properties of aqueous polystyrene latex dispersions from three synthetic batches, with nearly the same z-average particle sizes, 400 nm, but varying degrees of polydispersity, 0.085, 0.301, and 0.485, respectively, were systematically investigated using steady-state shear and oscillatory shear measurements. The particles were sized with photon correlation spectroscopy and transmission electron microscopy and were stabilized sterically with PEO-PPO-PEO triblock copolymer (Synperonic F127). Results from steady-state shear measurements show that the viscosities of the systems exhibit shear-thinning behavior at high solid fractions. However, the degree of shear thinning depends on the breadth of particle size distribution, with the narrowest distribution suspension exhibiting the highest degree of shear thinning. The Herschel-Bulkley relationship best describes the flow curves. The relative viscosities as a function of volume fraction data were compared, and it was found that the broadest distribution suspension had the lowest viscosity for a given volume fraction. In addition, the data were fitted to the Krieger-Dougherty equation for hard spheres. A reasonable agreement of theory with experiment is observed, particularly and surprisingly for the very broad distribution. However, when the contribution to the volume due to the adsorbed polymer layer is considered, the agreement between experiment and theory becomes closer for all the suspensions, although the agreement for the broad distribution suspension is now worse. Fitting the Dougherty-Krieger theory to the experimental data based on our experimental maximum packing fractions gives very good agreement for all the systems studied. From oscillatory shear measurements, the moduli were obtained as a function of frequency at various latex volume fractions. The results show general change of the dispersions from viscous (G" > G') at low volume fractions (0.25-0.30) to moderately elastic (G' > G") at moderately high volume fractions (0.41-0.45). The change at this concentration level is likely due to some compression and interpenetration of the stabilizing polymer chain at the periphery, indicating the dominance of the interparticle forces. Overall, the very broad distribution was found to have the lowest elastic modulus for a given volume fraction. Copyright 1999 Academic Press.

Journal Article↗

Incorporation of water-insoluble anticancer drug into polymeric micelles and control of their particle size.

A water-insoluble anticancer drug, KRN 5500 (KRN), was incorporated into polymeric micelles forming from poly(ethylene glycol-poly(amino acid) block copolymers by physical entrapment utilizing hydrophobic interactions between this drug and the poly(amino acid) chain block of the block copolymers. Three block copolymers were examined for this incorporation; poly(ethylene glycol)-poly(beta-benzyl l-aspartate) (PEG-PBLA) and its two derivatives obtained by partial hydrolysis at the beta-benzyl l-aspartate (BLA) units (PEG-P(Asp, BLA)) and by partial cetyl ester substitution at the BLA units (PEG-P(C16, BLA)), respectively. Among these block copolymers, considerable effects of the cetyl esterification were seen on KRN yield and particle size. Considerable differences in the KRN incorporation yield and particle size were also observed between DMF and DMS used as solvent to dissolve KRN and the block copolymers. Sonication was turned out to be an effective method to obtain a polymer micelles fraction in high efficiency, and sonication was considered to work for separating intermicellar associates into dispersed micelles. A KRN incorporation procedure by dialysis using PEG-P(C16, BLA) and DMSO (as solvent) followed by sonication brought about polymeric micelles of 71 nm in weight-average diameter. This shows successful incorporation of a water-insoluble drug into polymeric micelles by optimizing block copolymer structure and incorporation conditions.

Antibiotics, Antineoplastic↗

Modelling particle size distribution dynamics in marine waters.

Numerical simulations were carried out to determine the particle size distribution (PSD) in marine waters by accounting for particle influx, coagulation, sedimentation and breakage. Instead of the conventional rectilinear model and Euclidean geometry, a curvilinear collision model and fractal scaling mathematics were used in the models. A steady-state PSD can be achieved after a period of simulation regardless of the initial conditions. The cumulative PSD in the steady state follows a power-law function, which has three linear regions after log-log transformation, with different slopes corresponding to the three collision mechanisms, Brownian motion, fluid shear and differential sedimentation. The PSD slope varies from -3.5 to -1.2 as a function of the size range and the fractal dimension of the particles concerned. The environmental conditions do not significantly alter the PSD slope, although they may change the position of the PSD and related particle concentrations. The simulation demonstrates a generality in the shape of the steady-state PSD in the ocean, which is in agreement with many field observations. Breakage does not affect the size distribution of small particles, while a strong shear may cause a notable change in the PSD for larger and fractal particles only. The simplified approach of previous works using dimensional analysis still offers valuable approximations for the PSD slopes, although the previous solutions do not always agree with the simulation results. The variation in the PSD slope observed in field investigations can be reproduced numerically. It is argued that non-steady-state conditions in natural waters could be the main reason for the deviation of PSD slopes. A change in the nature of the particles, such as stickiness, and environmental variables, such as particle input and shear intensity, could force the PSD to shift from one steady state to another. During such a transition, the PSD slope may vary to some extent with the particle population dynamics.

Geologic Sediments↗

Radium-226 contents and Rn emanation coefficients of particle-size fractions of alkaline, acid and mixed U mill tailings.

Alkaline circuit and mixed, acid and alkaline circuit U mill tailings sampled at an inactive mill site near Monticello, UT, and tailings from an active, acid-leach U mill were separated into particle-size fractions ranging from +10 mesh to -325 mesh by dry and wet separation techniques. The 226Ra contents and 222Rn emanation coefficients of these fractions were determined. Dry tailings show a high degree of aggregation that tends to mask the relation of properties, such as Ra content and Rn emanating power, to dispersed-particle size. Coarse-tailings fractions (+325 mesh) had emanation coefficients which were from 25 to 45% lower than those of their fine-fraction counterparts. Emanation coefficients measured for tailings derived from a salt roast/carbonate-leach process suggest that such are roasting does not lead to reductions in Rn emanation in the tailings derived therefrom.

Hydrogen-Ion Concentration↗

Total respiratory tract deposition of fine micrometer-sized particles in healthy adults: empirical equations for sex and breathing pattern.

Accurate dose estimation under various inhalation conditions is important for assessing both the potential health effects of pollutant particles and the therapeutic efficacy of medicinal aerosols. We measured total deposition fraction (TDF) of monodisperse micrometer-sized particles [particle diameter (Dp) = 1, 3, and 5 microm in diameter] in healthy adults (8 men and 7 women) in a wide range of breathing patterns; tidal volumes (Vt) of 350-1500 ml and respiratory flow rates (Q) of 175-1,000 ml/s. The subject inhaled test aerosols for 10-20 breaths with each of the prescribed breathing patterns, and TDF was obtained by monitoring inhaled and exhaled aerosols breath by breath by a laser aerosol photometer. Results show that TDF varied from 0.12-0.25, 0.26-0.68, and 0.45-0.83 for Dp = 1, 3, and 5 microm, respectively, depending on the breathing pattern used. TDF was comparable between men and women for Dp = 1 microm but was greater in women than men for Dp = 3 and 5 microm for all breathing patterns used (P < 0.05). TDF increased with an increase in Vt regardless of Dp and Q used. At a fixed Vt TDF decreased with an increase in Q for Dp = 1 and 3 microm but did not show any significant changes for Dp = 5 microm. The varying TDF values, however, could be consolidated by a single composite parameter (omega) consisting of Dp, Vt, and Q. The results indicate that unifying empirical formulas provide a convenient means of assessing deposition dose of particles under varying inhalation conditions.

Adult↗

Effect of wheat bran on serum lipids: influence of particle size and wheat protein.

OBJECTIVE: Wheat fiber appears to protect from cardiovascular disease despite its lack of consistent effect on serum lipids. We therefore wished to determine whether reported inconsistencies in the effect of wheat bran resulted from differences in particle size or its high gluten content. METHODS: Two studies were conducted. In one-month metabolic diets, 24 hyperlipidemic subjects consumed breads providing an additional 19 g/d dietary fiber as medium or ultra-fine wheat bran and extra protein (10% of energy as wheat gluten). In two-week ad libitum diets, 24 predominantly normolipidemic subjects consumed breakfast cereals providing an additional 19 g/d of dietary fiber as coarse or a mixture of ultra-fine and coarse wheat bran with no change in gluten intake. Both studies followed a randomized crossover design with control periods when subjects ate low-fiber breads and cereals respectively with no added gluten. Fasting blood lipids were measured on day zero and at the end of each phase. RESULTS: Wheat bran had no effect on total, LDL or HDL cholesterol irrespective of particle size or level of gluten in the diet. However, consumption of increased gluten in the metabolic study was associated with a 13+/-4% reduction in serum triglycerides (p = 0.005) which was not seen in the normal-gluten ad libitum study. CONCLUSIONS: The protective effect of wheat fiber in cardiovascular disease cannot be explained by an effect of wheat bran in reducing serum cholesterol although in hyperlipidemic subjects displacement of carbohydrate by gluten on the high-fiber phases was associated with lower serum triglycerides.

Adult↗

Micro-thermal field-flow fractionation: new high-performance method for particle size distribution analysis.

Micro-thermal field-flow fractionation (mu-TFFF) was applied to the separation of polystyrene latices. This new high-resolution technique allows determination of the particle size distribution (PSD) if carried out under optimized experimental conditions. The optimum temperature of the accumulation wall, which influences the relaxation processes and, consequently, the zone broadening, was chosen on the basis of our prior work. The flow rate was chosen as a compromise between the theoretical optimum value, which is very low because the diffusion coefficients of the colloidal particles are very small, and a value allowing performance of the PSD analysis in a reasonable time. These experimental conditions can be manipulated easily due to the high versatility of mu-TFFF, which follows from a large decrease of the heat energy flux across the channel with its reduced dimensions in comparison with standard TFFF. The PSDs obtained from mu-TFFF data are compared with results from quasi-elastic laser light scattering (QELS) and transmission electron microscopy (TEM). It has been found that a baseline resolution of a model mixture of two samples of close average particle diameters can be achieved by an appropriate choice of the temperature drop in mu-TFFF, whereas only a broad, unresolved PSD of the mixed sample was obtained from the QELS measurement. The TEM of the mixed sample revealed the presence of two particle size populations. However, the number of particles which are practically counted on a TEM picture is several orders of magnitude lower than the number of particles taken into account in mu-TFFF or QELS. Consequently, the PSD obtained from the TEM did not represent the whole sample. Comparison of mu-TFFF with modern hydrodynamic chromatography (HC) has shown that the methods exhibit roughly the same resolution and time of analysis. Nevertheless, mu-TFFF is a more universal technique because the separation of the colloidal particles or of the macromolecules within a broad range of molar masses is carried out on the same channel, as demonstrated previously.

Journal Article↗

Effects of variation in particle size on biaxial flexural strength of two conventional glass-ionomer cements.

Conventional glass-ionomer cements (GICs) have a slow maturation time. Reduction in time of maturation may be achieved by acceleration of the setting reaction. One factor that assists this is the reduction in glass particle size producing a larger surface area for reaction. The resulting rapid set and more rapid maturation should potentially lead to less long-term degradation. Biaxial strength measurements were made with respect to time for two GICs of similar compositions but with differing particle size distributions at different time intervals after immersion in both water and artificial saliva. There was little difference between the strength of the two materials over periods up to 12 weeks. A theoretical estimation of the relative surface areas of glasses showed that, despite there being twice the surface area available for reaction for one glass, there was little difference in strengths values between the two materials at any of the times tested here. The similarity in strength values despite this substantial difference suggests that the larger particles may have a greater influence in the cement forming process.

Dental Stress Analysis↗

Chemical composition, particle size range, and biological activity of some low molecular weight heparin derivatives.

Several low molecular weight (LMW) heparin sodium derivatives from different sources, as well as some related regular heparin sodium preparations, were examined for chemical composition by high field (300 MHz) 1H NMR spectroscopy, for particle size range by quasi-elastic light scattering (QELS) methods, and for anti-coagulation potency and anti-factor Xa activity by the standard U.S. Pharmacopeial assays described for regular heparin. The NMR spectra provided insight into possible modes of depolymerization used to generate the LMW heparins, as well as into the presence of dermatan sulfate or other chemical contaminants. The QELS analysis permitted the heparin preparations to be characterized and compared by virtue of their distinctive particle size distributions.

Dermatan Sulfate↗

Effects of androgen manipulation on postprandial triglyceridaemia, low-density lipoprotein particle size and lipoprotein(a) in men.

Although androgenic hormones decrease HDLC concentration, no direct evidence has linked them to atherosclerosis. The present study was undertaken to extend our ability to assess risk associated with androgen induced lipoprotein(Lp) changes by simultaneously gathering information about postprandial triglyceridaemia (PPT), LDL particle size, HDL and Lp(a) in men either taking exogenous androgens or with suppressed endogenous androgen concentrations. The experimental groups comprised nine male bodybuilders who self-administered anabolic-androgenic steroids (AAS) for a mean period of 6.5 weeks, and 10 healthy men whose testosterone concentration had been reversibly suppressed for 5 weeks using the GnRH agonist triptorelin (Decapeptyl; D-Trp-6-LHRH). A separate group receiving no hormonal treatment provided analytical control (n=7). Lipoprotein size was assessed by gradient gel electrophoresis categorisation (GGE), lipoprotein concentrations by immuno and enzymatic assays and PPT by a standardised oral fat tolerance test (65g /m(2)). Testosterone concentration was significantly reduced on triptorelin from 7.32+/-1.92 to 1.15+/-0.57 ng/ml (P=0.002). High dose AAS use was confirmed by urinalysis. With AAS use, mean HDLC and Lp(a) concentrations and PPT decreased from 0.9+/-0.3 to 0.7+/-0.3 mmol/l (P=0.004), 125+/-128 to 69+/-73 U/l (P=0.008) and 11.6+/-10.0 mmol/l h to 7.5+/-5.4 mmol/l h (P=0.027) respectively. Mean total cholesterol and LDLC were unchanged. LDL size was unchanged in six AAS users, decreased in one but remaining in the normal size range, and increased in two from small LDL to the normal range. Size changes in the latter two subjects were associated with 42 and 58% reductions in PPT respectively. In the triptorelin group, mean total cholesterol, HDLC and Lp(a) were increased from 4.8+/-0.8 mmol/l to 5.2+/-1.0 mmol/l (P=0.039), 1.1+/-0.2 to 1.4+/-0.3 mmol/l (P=0.002) and 278+/-149 to 377+/-222 U/l (P=0.004) respectively. Mean LDLC concentration and PPT were unchanged. LDL particle size increased in four, decreased in two, and was unchanged in four subjects. LDL size decreased in two and showed no change in the other five control subjects. Other lipid measures were unchanged in the control group. Thus, apart from lowering HDLC concentrations, no other potentially atherogenic effects of endogenous androgens or AAS were observed. A suppression of Lp(a) as well as a reduced PPT and increased LDL size in predisposed individuals may be antiatherogenic effects of AAS.

Adult↗