PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Flow Cytometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Use of FITC-labeled influenza virus and flow cytometry to assess binding and internalization of virus by monocytes-macrophages and lymphocytes.

The binding of influenza virus to the surface of cells and the internalization of virus particles by all or a subset of cells are key points in the pathogenesis of viral infection. The current studies established a method for discrimination of surface-bound from internalized influenza virus. Fluorescein isothiocyanate (FITC) was attached to the viral hemagglutinin and neuroaminidase proteins; the fluorescent virus retained infectivity. A flow cytometric technique was then adapted for study of virus-cell interactions, with addition of ethidium bromide to quench green fluorescence associated with FITC-labeled virus that was cell-bound but remained external. Ethidium bromide was excluded by intact cell membranes, and internalized virions retained green fluorescence. Cells could be examined by fluorescence microscopy or flow cytometry, with flow cytometry allowing rapid, kinetic assessment of large numbers of cells and subsets of virus-exposed cells. The data showed that, whereas a majority of both monocytes-macrophages and lymphocytes bound influenza virus, a large percentage of monocytes-macrophages but only a very small percentage of lymphocytes internalized the virus. This procedure provides a simple and effective method to distinguish surface-bound from internalized influenza virus, and allows precise kinetic analyses on large numbers of cells.

Adult↗

Flow cytometry.

A brief review of flow cytometry is presented. Emphasis is on the construction of relatively simple instruments and on their application to problems in medical physics. Among these are the problems of measuring the biological parameters that determine the response of tumors to therapy and of measuring the biological damage in people exposed to ionizing radiations.

Cytological Techniques↗

Flow cytometry as a method for studying effects of stressors on primary rat neurons.

The mechanisms associated with cell death have been an important focus for neurobiology research. In the present study, the methodology of flow cytometry was used to optimize quantification of the toxic effects of tumor necrosis factor-alpha (TNF-alpha), trans-4-hydroxy-2-nonenal (4-HNE), and aged amyloid-beta (Abeta1-42) on rat primary cortical neurons. The fluorescent dyes annexin V-FITC and propidium iodide (PI) were used to identify populations of viable, early apoptotic, necrotic and late apoptotic cells by flow cytometry. Prior to exposure, the primary cultures showed 83% cell viability. Flow cytometry following labeling of cells with a specific neuronal marker, TUJ-1, revealed 82% pure neuronal populations, whereas approximately 7% were astrocytic as shown by glial fibrillary acidic protein positivity. Exposure of primary cultures to TNF-alpha, 4-HNE, and aged Abeta1-42 gave an increased number of early apoptotic cells. We show that flow cytometry is a suitable method for quantifying effects of different stressors on neurons in primary cultures. This technique could be useful for screening and testing of pharmacological compounds relevant to neurodegenerative disorders.

Aldehydes↗

Alveolar macrophage-environmental particle interaction: analysis by flow cytometry.

Inhaled particulates such as pollutant particles, allergens, and microorganisms are rapidly cleared by alveolar macrophages (AMs). Methods for analysis of AM-particle interaction have been hindered by the lack of a convenient assay. Flow cytometry offers rapid, sensitive, and reproducible measurements of single cells in suspension. Multiple parameters can be measured in real time. Here we will review the application of flow cytometry to the study and characterization of AM receptors for unopsonized environmental particles. We will discuss the role of this technique in identifying a key AM receptor system involved in lung defense. Multiparametric flow cytometry to analyze intracellular functional parameters, though a powerful and unique tool, needs to be interpreted with caution. We will also discuss the advantages and limitations of flow cytometry in analysis of AM-particle interaction.

Allergens↗

Helper T-lymphocyte count. TRAx CD4 test kit versus conventional flow cytometry.

BACKGROUND: We evaluated a newly developed enzyme-linked immunosorbent assay system for measuring helper T-lymphocyte count. METHODS: Data from 111 human immunodeficiency virus-infected injection drug users in a cohort study were analyzed by flow cytometry and independent duplicate runs of the TRAx enzyme-linked immunosorbent assay. RESULTS: The mean helper T-cell counts were 470, 480, and 506 per microliter by flow cytometry and TRAx runs 1 and 2, respectively. The correlation coefficients for TRAx runs 1 and 2 with the flow cytometry results as the dependent variable were .93 and .91, respectively. A cross-tabulation of the enzyme-linked immunosorbent assay helper T-lymphocyte counts with flow cytometry counts showed agreement of 71% and 76% when the flow count was between 201 and 500, and 88% and 90% when it was greater than 500 cells per microliter. In those samples with 200 or fewer helper T cells, agreement was 73% and 41% for each TRAx run. CONCLUSIONS: The TRAx enzyme-linked immunosorbent assay system is an acceptable method for measuring helper T-lymphocyte count, but should be recalibrated for better performance at helper T-cell counts below 200 per microliter.

CD4 Lymphocyte Count↗

[Flow cytometry and cell sorting: current state and prospects for use in molecular biology].

A survey of the specific features of flow cytometry, principals of instrumentation and main parameters of the modern cell sorting cytometers is given. Analytical capacities of flow cytometry as well as the main directions of its applications in cell biology, clinical diagnostics, immunology, biotechnology and molecular biology are considered. Also a possible future development of flow cytometry instrumentation and applications in molecular biology are briefly discussed.

Animals↗

Immune modulator studies in primates: the utility of flow cytometry and immunohistochemistry in the identification and characterization of immunotoxicity.

Exposure to natural environmental products, biopharmaceuticals, or investigational adjuvants has the potential to negatively impact the immune system, resulting in either up- or downregulation of immune function (immunomodulation). Many current protocols for primate toxicologic testing call for the evaluation of changes in immune cell number (peripheral blood or tissue), alterations in the weights of immune system organs (lymph nodes, spleen, thymus), and/or increases in the overall incidence of infections or neoplasms; these data are relied upon to suggest altered immune function. However, these are informative only when clear differences in frequency and/or severity of effects can be distinguished across control and dosed groups. In the absence of such distinct morphologic or clinical pathologic changes, the identification of potential immunomodulatory effects can present a much greater challenge. Additional evaluations may be needed to detect altered immune system integrity; these are based on in vivo assessments in primates of cellular or humoral responsiveness. Immunomodulatory effects can be characterized by in vitro or in vivo immune function tests: these tests require prestudy planning to integrate assessments into ongoing toxicology programs. These methods also involve specialized training and equipment, particularly if the intent is to evaluate parameters in a GLP laboratory setting. In primate toxicology, the added costs required to perform a complete functional analysis of the immune system can be substantial, but may be warranted depending on the clinical development plans. Two analytical methods that are easily incorporated into the standard toxicology profile in primates are flow cytometry and immunohistochemistry. Flow cytometry (FC) is used to assess changes in the relative distribution of immune cell marker expression, and where marker expression is known to fluctuate with the state of cell activation, can also provide information on functional attributes of immune cells. Immunohistochemistry (IHC) provides a means to evaluate similar characteristics of immune cells within tissue sections. Used together, FC and IHC can aid in the identification of changes in immune system that may not be apparent by traditional testing procedures (such as H&E staining), thus aiding in the characterization of immune system alterations. This presentation focused on the utility of flow cytometry and immunohistochemistry in a standard primate toxicology evaluation, with representative examples showing the benefits of these technologies in the diagnosis of potential immunomodulatory effects.

Adjuvants, Immunologic↗

A rapid method for detection of nongenotoxic carcinogens of environmental pollutants using synchronized V79 cells and flow cytometry.

Synchronized V79 cells were treated before entering mitosis with known and suspicious mitotic arrestants and analyzed by flow cytometry and by light microscopy. Colcemid, nocodazole, vinblastine, diethylstilbestrol, triethyl lead and cadmium sulfate caused a dose dependent mitotic arrest of up to 80%, in comparison with 6% for the controls. Mixtures of polycyclic aromatic hydrocarbons and heterocyclic compounds induced a mitotic arrest of 50%-60%. Extracts of airborne particulates revealed a mitotic arrest of 10%-40%. In contrast, benzoquinone and hydroquinone led to a G2-block rather than to a mitotic arrest. Results of flow cytometry measurements correlated well with those obtained by light microscopy. Cell synchronization in combination with flow cytometry seems to be of considerable value as a rapid method for testing nongenotoxic agents with mitotic arresting activity.

Animals↗

Polarization of scatter and fluorescence signals in flow cytometry.

BACKGROUND: The pulses of light scatter and fluorescence measured in flow cytometers exhibit varying degrees of polarization. Flow cytometers are heterogeneously sensitive to this polarization, depending on the light source(s), the optical layout, and the types of mirrors and filters used. Therefore, fluorescence polarization can affect apparent intensity ratios between particles and interfere with schemes for interlaboratory standardization. METHODS: We investigate the degree to which polarization affects common flow cytometry measurements. Our technique for determining polarization differs from previous methods because complete distributions of intensity versus polarization angle are measured, rather than intensities at just two orthogonal polarization angles. Theoretical models for scatter and fluorescence are presented and verified by making polarization measurements of calibration beads. RESULTS: Measurements of cells stained with a variety of dyes illustrate that fluorescence polarization occurs frequently in flow cytometry. CONCLUSIONS: Consequences for quantitative cytometry are discussed, and the use of the "magic angle" to make a flow cytometer insensitive to fluorescence polarization is proposed.

Animals↗

Separation accuracy of free flow electrophoresis as proved by flow cytometry.

The separation accuracy of the free flow electrophoresis ACE 710 device was proved by immunological methods. Several cell populations of human peripheral blood were purified using physical cell isolation methods such as countercurrent centrifugal elutriation and cell electrophoresis. The purified cell fractions were treated with fluoresceinisothiocyanate-labelled antibodies. The percentages of cells in each fraction binding the antibodies of interest were determined by flow cytometry. The analyses revealed that with the help of free flow electrophoresis, given cell populations of human peripheral blood can be highly enriched and that preenrichment of minor cell populations enhances the efficacy of a flow cytometer.

Cell Separation↗

Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria.

Within the contemporary multitude of complex methods used in clinical flow cytometry, very few techniques exist which can be described as disease-specific diagnostic tests. Detection of glycophosphatidylinositol (GPI)-linked antigens on hematopoietic cells using monoclonal antibodies and flow cytometry forms the basis of a specific diagnostic test for paroxysmal nocturnal hemoglobinuria (PNH). Absent or markedly diminished expression of GPI-linked antigens is, in the appropriate clinical setting, specific for all patients with PNH. Clinically, PNH is a syndrome characterized by bone marrow failure, acquired hemolytic anemia, and a thrombotic tendency. The molecular genetic lesion responsible for this condition is a somatic mutation of the X-linked pig-a gene within a multipotent hematopoietic stem cell. Due to its rarity, delay in diagnosis is not uncommon for patients with PNH. Once a definitive diagnosis is established, this can make a considerable impact on patient management and prognosis. In this article, we review the complimentary roles that molecular biology and flow cytometry have played in unraveling the genotypic and phenotypic aspects of this unique condition.

Blood Platelets↗

Insulin binding to human cultured lymphocytes measured by flow cytometry using three ligands.

The binding of insulin to cultured IM-9 human lymphocytes was studied by flow cytometry using FITC-insulin and biotinylated insulins coupled to streptavidin-phycoerythrin (N alpha beta 1-biotinylinsulin (B-insulin) and N alpha B1-(biotinyl-epsilon-aminocaproyl)insulin (NBC-insulin)). The reference methods were 125I-insulin binding and the insulin-antiinsulin antibody complexes for flow cytometry. There was a close correlation between 125I-insulin binding and increase in fluorescence for B-insulin, NBC-insulin, and insulin-anti-insulin antibody complexes, but not for FITC-insulin. NBC-insulin gave the largest increase in fluorescence (79 +/- 9 channels) and the the insulin-antiinsulin antibody complexes the smallest (34 +/- 2 channels) (P < 0.05). FITC-insulin and B-insulin gave similar results: 47 +/- 6 and 59 +/- 6 channels. The concentration reducing 125I-insulin binding by 50% was 1.1 x 10(-9) M for native insulin, 2.7 x 10(-9) M for B-insulin, 3.3 x 10(-9) M for NBC-insulin, and 6.6 x 10(-9) M for FITC-insulin (P < 0.05). Nonspecific binding was low for B-insulin and NBC-insulin but reached 75% for 10(-6) M FITC-insulin. These results suggest that B-insulin and NBC-insulin are suitable ligands for insulin binding studies using flow cytometry. This two-step procedure is easier than the insulin-antiinsulin antibody complex technique. Its poor affinity, specificity, and sensitivity make FITC-insulin less suitable.

Animals↗

[Flow cytometry in datecting lymph node micrometastasis in colorectal cancer].

OBJECTIVE: To study the methodology and significance of flow cytometry in detecting lymph node micrometastasis of colorectal cancer. METHODS: One hundred sixty-two cellular suspensions were prepared with lymph nodes which were resected radically on 25 patients with colorectal cancer and in which no cancer cells were found by HE staining. Different concentrations of cultured Lovo colorectal cancer cells were added into the celular suspension prepared from lymph node tissue of persons without colorectal cancer in order to prepare a control model. Dual staining with CK/FTTC and PI was made to the sedimetns from those 2 kinds of suspension. Flow cytometry was used to detect cancer cells. RESULTS: An ideal correlation was obtained between the detection value and the theoretical value of cancer cells in the specimen suspensions and control models (r = 0.097 6) with a sensitivity rate of 10/10(5). Cancer cells were detected from 7 out of the 25 patients and 30 of the 162 cellular suspensions. The detection rate was correlated with the size and infiltrating depth of the cancer. CONCLUSION: Flow cytometry is a reliable, rapid, and quantitative method for detecting lymph node micrometastasis in colorectal cancer.

Colorectal Neoplasms↗

Using 4-color flow cytometry to identify abnormal myeloid populations.

CONTEXT: The diagnosis of myeloproliferative disorders (MPDs) and myelodysplastic syndromes (MDSs) has historically relied on combining clinical information with the morphologic features of the peripheral blood and bone marrow to reach a final diagnosis. Objective evidence of a myeloid stem cell neoplasm in the form of a clonal cytogenetic abnormality is provided in only 30% to 40% of the non-chronic myeloid leukemia (CML) chronic MPDs (non-CML MPDs) and in a similar percentage of the MDSs. OBJECTIVE: To identify normal patterns of antigen expression during myeloid maturation and to determine whether flow cytometric evaluation of myeloid maturation represents an additional objective way to assess the likelihood of a stem cell neoplasm. DESIGN: We retrospectively evaluated 4-color flow cytometry data from more than 400 bone marrow aspirates obtained since 1998 from patients suspected of having a non-CML MPD or an MDS. RESULTS: Reproducible patterns of antigen expression were seen in normal myeloid maturation as well as in benign reactive settings such as marrow regeneration. In addition, we summarize data, presented in detail elsewhere, from a retrospective comparison of the sensitivity of flow cytometry with conventional cytogenetics for a large number of bone marrow aspirates on which both types of studies were performed. These data indicate that more than 90% of non-CML MPD and MDS cases with a clonal cytogenetic abnormality will be identified as abnormal by 4-color flow cytometry, and they therefore validate the use of flow cytometry in the diagnosis of these disorders. CONCLUSIONS: In experienced laboratories, 4-color flow cytometry represents a valuable addition to the workup of non-CML MPDs and MDSs.

Antigens, CD↗

Quantitative DNA analysis and proliferation in breast carcinomas. A comparison between image analysis and flow cytometry.

The DNA content and proliferation in 100 invasive breast carcinomas were evaluated by computerized image analysis (IA) and flow cytometry (FCM). For DNA content, image analysis of Feulgen-stained slides of fresh tumor imprints were compared with flow cytometry of propidium iodide-stained disaggregated fresh tumor tissue. The DNA indices obtained by the two methods showed close correlation by linear regression analysis (r = 0.89, p less than .001). There were 44 (44%) diploid and 56 (56%) aneuploid tumors. There was agreement between the two methods in detection of aneuploidy in 81% of tumors. Image analysis required smaller tissue samples, permitted direct visualization and selection of tumor cells, and was more sensitive in detecting tetraploid and highly aneuploid cell populations. In contrast, flow cytometry histograms provided better resolution, and were more effective in detecting multiploid tumors and near-diploid aneuploid tumors. Aneuploidy was significantly related to various adverse prognostic parameters, namely, negative estrogen receptor, high mitotic rate, high histologic and nuclear grades. Proliferation was evaluated by measuring the FCM S phase fraction (SPF), and by image analysis quantitation of immunohistochemical staining using Ki-67 monoclonal antibody. SPF and Ki-67 count showed modest correlation (r = 0.42). Both SPF and Ki-67 count were significantly related to the mitotic rate, histologic and nuclear grades. Our results indicate that the two methods provide comparable results, but offer individual advantages and are complementary techniques in analyzing DNA ploidy and proliferation in breast carcinomas.

Adenocarcinoma, Mucinous↗

Rapid ganciclovir susceptibility assay using flow cytometry for human cytomegalovirus clinical isolates.

Rapid, quantitative, and objective determination of the susceptibilities of human cytomegalovirus (HCMV) clinical isolates to ganciclovir has been assessed by an assay that uses a fluorochrome-labeled monoclonal antibody to an HCMV immediate-early antigen and flow cytometry. Analysis of the ganciclovir susceptibilities of 25 phenotypically characterized clinical isolates by flow cytometry demonstrated that the 50% inhibitory concentrations (IC50s) of ganciclovir for 19 of the isolates were between 1.14 and 6.66 microM, with a mean of 4.32 microM (+/-1.93) (sensitive; IC50 less than 7 microM), the IC50s for 2 isolates were 8.48 and 9.79 microM (partially resistant), and the IC50s for 4 isolates were greater than 96 microM (resistant). Comparative analysis of the drug susceptibilities of these clinical isolates by the plaque reduction assay gave IC50s of less than 6 microM, with a mean of 2.88 microM (+/-1.40) for the 19 drug-sensitive isolates, IC50s of 6 to 8 microM for the partially resistant isolates, and IC50s of greater than 12 microM for the four resistant clinical isolates. Comparison of the IC50s for the drug-susceptible and partially resistant clinical isolates obtained by the flow cytometry assay with the IC50s obtained by the plaque reduction assay showed an acceptable correlation (r2 = 0.473; P = 0.001), suggesting that the flow cytometry assay could substitute for the more labor-intensive, subjective, and time-consuming plaque reduction assay.

Antigens, Viral↗

[Standardization in flow cytometry].

Analysis of lymphocyte subsets and determination of leukemic cells by flow cytometry has now become an important clinical test. With recent technological developments, reliability was improved and the procedure became easier. To establish quality assurance procedures for flow cytometry, standardization is necessary. In the United States, the National Committee for Clinical Laboratory Standards (NCCLS) has been working actively and has published several tentative guidelines. However, in Japan, such work lags behind that in western countries. The results of quality control surveys show that differences in data exist among instruments and laboratories. To minimize such differences, nation-wide surveillance must be established. Also, efforts should be made to establish reference methods and reference materials that will lead to standardized results. We hope standardization will ensure precision and accuracy in flow cytometric results in clinical laboratories.

Antibodies, Monoclonal↗

T-cell subset analysis of peripheral T-cell lymphomas by paraffin section immunohistology and correlation of CD4/CD8 results with flow cytometry.

Peripheral T-cell lymphomas (PTCLs) are often diagnosed after demonstration of T-lineage-related antigen expression on neoplastic lymphocytes by paraffin immunoperoxidase (PIP). However, complete T-cell subset analysis for helper, suppressor/cytotoxic, alphabeta, and gammadelta phenotypes has not been examined by PIP. Therefore, PIP was performed for CD4, CD8, T-cell intracellular antigen (TIA)-1, and betaF1 expression in 31 PTCLs previously studied for CD4 and CD8 by flow cytometry. The CD4 and CD8 results from both methods were compared. All betaF1- PTCLs were studied for T-cell receptor (TCR)gammadelta by PIP. PIP showed 71% correlation with the 21 PTCLs that had distinct CD4+ CD8- or CD4- CD8+ phenotypes by flow cytometry, with 64% and 90% sensitivity for CD4 and CD8 expression, respectively. Tumor cells in four of six PTCLs that had no clear CD4 or CD8 predominance or coexpression of these antigens by flow cytometry were shown to be CD4+ CD8- or CD4- CD8+ by PIP. Twelve (39%) PTCLs demonstrated a cytotoxic (TIA-1+) phenotype by PIP, including eight CD4- CD8+, one CD4+ CD8- and three CD4- CD8- cases. Of 30 immunoreactive PTCLs, 26 (87%) were alphabeta (betaF1+) by PIP. Both large cell cases among four betaF1- PTCLs were TCRgammadelta+ by PIP, including one gammadelta+ case confirmed by flow cytometry. We conclude that CD4 and CD8 T-cell subsets can be assigned for most PTCLs by PIP, with CD4 showing moderate and CD8 showing strong correlation with flow cytometric results. PIP can also define CD4 or CD8 expression on tumor cells in the PTCLs in which flow cytometry produces inconclusive results. Cytotoxic PTCLs can be identified easily with TIA-1, which can also distinguish cytotoxic from "suppressor" CD8+ PTCLs. Most PTCLs are derived from alphabeta T-cells, however some large cell gammadelta PTCLs may be identified by PIP.

CD4-CD8 Ratio↗