PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays.

We present for the first time a microfluidic cell culture array for long-term cellular monitoring. The 10 x 10 array could potentially assay 100 different cell-based experiments in parallel. The device was designed to integrate the processes used in typical cell culture experiments on a single self-contained microfluidic system. Major functions include repeated cell growth/passage cycles, reagent introduction, and real-time optical analysis. The single unit of the array consists of a circular microfluidic chamber, multiple narrow perfusion channels surrounding the main chamber, and four ports for fluidic access. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C. The observed doubling time was 1.4 +/- 0.1 days with a peak cell density of approximately 2.5*10(5) cells/cm(2). Cell assay was demonstrated by monitoring the fluorescence localization of calcein AM from 1 min to 10 days after reagent introduction. Confluent cell cultures were passaged within the microfluidic chambers using trypsin and successfully regrown, suggesting a stable culture environment suitable for continuous operation. The cell culture array could offer a platform for a wide range of assays with applications in drug screening, bioinformatics, and quantitative cell biology.

Cell Culture Techniques↗

Single cell manipulation, analytics, and label-free protein detection in microfluidic devices for systems nanobiology.

Single cell analytics for proteomic analysis is considered a key method in the framework of systems nanobiology which allows a novel proteomics without being subjected to ensemble-averaging, cell-cycle, or cell-population effects. We are currently developing a single cell analytical method for protein fingerprinting combining a structured microfluidic device with latest optical laser technology for single cell manipulation (trapping and steering), free-solution electrophoretical protein separation, and (label-free) protein detection. In this paper we report on first results of this novel analytical device focusing on three main issues. First, single biological cells were trapped, injected, steered, and deposited by means of optical tweezers in a poly(dimethylsiloxane) microfluidic device and consecutively lysed with SDS at a predefined position. Second, separation and detection of fluorescent dyes, amino acids, and proteins were achieved with LIF detection in the visible (VIS) (488 nm) as well as in the deep UV (266 nm) spectral range for label-free, native protein detection. Minute concentrations of 100 fM injected fluorescein could be detected in the VIS and a first protein separation and label-free detection could be achieved in the UV spectral range. Third, first analytical experiments with single Sf9 insect cells (Spodoptera frugiperda) in a tailored microfluidic device exhibiting distinct electropherograms of a green fluorescent protein-construct proved the validity of the concept. Thus, the presented microfluidic concept allows novel and fascinating single cell experiments for systems nanobiology in the future.

Animals↗

Bioanalysis in structured microfluidic systems.

Microfluidic and lab-on-a-chip devices have attracted widespread interest in separation sciences and bioanalysis. Recent designs in microfluidic devices extend common separation concepts by exploiting new phenomena for molecular dynamics on a length scale of 10 mum and below, giving rise to novel manipulation tools and nonintuitive phenomena for microseparations. Here, we focus on three very recent developments for bioseparations based on tailored microfluidic systems: Single cell navigation, trapping and steering with subsequent on-chip lysis, protein separation and LIF detection (Section 3.1), then we report dielectrophoretic trapping and separation of large DNA fragments in structured microfluidic devices (Section 3.2). Finally, a paradoxial migration phenomenon based on thermal fluctuations, periodically arranged microchannels and a biased alternating current electric field is presented in Section 3.3.

Animals↗

Tobacco protoplast culture in a polydimethylsiloxane-based microfluidic channel.

Several advances have been made in the use of microfluidic devices for insect and mammalian cell cultures, but no reports of their use for plant cell cultures have been published. We, therefore, conducted a plant cell culture in a microfluidic device using polydimethylsiloxane. Nicotiana tabacum protoplasts were cultured in a variously shaped polydimethylsiloxane channel containing Nitsch medium supplemented with 0.5 g of NLN-13 vitamin mixture, 2.0 mg of alpha-naphthaleneacetic acid, and 0.5 mg of 6-benzyladenine per liter and 9% mannitol. Protoplasts in the polydimethylsiloxane channel showed cell division and microcolony formation within 4 weeks. The use of a microfluidic channel is a novel technique in the field of plant cell culture. The results of this study will encourage the utilization of polydimethylsiloxane-based microfluidic devices in plant cell engineering and cell analysis.

Cell Culture Techniques↗

Cross-talk problem on a fluorescence multi-channel microfluidic chip system.

Development of a compact fluorescence-based detection system for use in a micro-analytical system, such as a point-of-care diagnostic system, often requires a multi-channel microfluidic chip system. Since the materials used for microfluidic chips usually are transparent in the visible region and have a refractive indices higher than that of air or the surrounding environment, the fluorescence emission and scattered excitation light can propagate through the chip. We observed that such propagation can cause cross-talk between adjacent channels, and may become the major source of noise in the system and/or photo bleach the fluorescent samples in the adjacent channels, particularly for the small distances between the channels found in microfluidic chips, usually in order of several micro m. We monitored this cross-talk using fluorescein as a fluorescent sample and Mylar sheeting as a microfluidic chip material. We then discuss how this cross-talk can be avoided using a simple, inexpensive and effective method.

Artifacts↗

Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip.

A microfluidic biochip for conducting an array of polymerase chain reaction (PCR) simultaneously was fabricated to understand the microfluidic loading process of PCR solution into microfabricated glass reaction chambers. The geometrical factors of the microfluidic structure, including the shape and depth of the microchamber, shape and size of the microchannels were investigated on the formation of air bubbles trapped within the microchamber during the PCR solution loading process. Furthermore, the effects of surface properties of the microfluidic structure, including hydrophilicity of the microchamber and inlet channel, and hydrophobicity of the outlet channel, on the loading of PCR solution, especially on the formation of air bubbles were studied. As a result, the surface wetting property of the microchamber was found to be the main reason for the formation of the air bubbles inside the microchamber during the loading of PCR solution in the biochips. A solution to avoid the air trapping has been proposed and investigated.

DNA↗

Agonist-induced calcium response in single human platelets assayed in a microfluidic device.

To facilitate drug discovery directed toward platelet-specific targets, we developed a platelet isolation and fluorophore-loading method that yields functionally responsive platelets in which we were able to detect agonist-induced calcium flux using a microfluidics-based screening platform. The platelet preparation protocol was designed to minimize preparation-induced platelet activation and to optimize signal strength. Measurement of platelet activation, as monitored by ratiometric determination of agonist-induced calcium flux in fluor-loaded human platelets, was optimized in a macrosample cuvette format in preparation for detection in a microfluidic chip-based assay. For the microfluidic device used in these studies, a cell density of 1 to 2 x 10(6) platelets per milliliter and a nominal flow rate of 5 to 10 nl per second provided optimal event resolution of 5 to 20 platelets traversing the detection volume per unit time. Platelets responded in a dose-dependent manner to adenosine diphosphate and protease-activating peptide (PAR) 1 thrombin receptor-activating peptide (TRAP). The work presented here constitutes proof-of-principle experiments demonstrating the enabling application of a microfluidic device to conduct high-throughput signaling studies and drug discovery screening against human platelet targets.

Adenosine Diphosphate↗

Comparative modeling and analysis of microfluidic and conventional DNA microarrays.

A theoretical analysis was developed to predict molecular hybridization rates for microarrays where samples flow through microfluidic channels and for conventional microarrays where samples remain stationary during hybridization. The theory was validated by using a multiplexed microfluidic microarray where eight samples were hybridized simultaneously against eight probes using 60-mer DNA strands. Mass transfer coefficients ranged over three orders of magnitude where either kinetic reaction rates or molecular diffusion rates controlled overall hybridization rates. Probes were printed using microfluidic channels and also conventional spotting techniques. Consistent with the theoretical model, the microfluidic microarray demonstrated the ability to print DNA probes in less than 1 min and to detect 10-pM target concentrations with hybridization times in less than 5 min.

DNA↗

Microfluidic technology for PET radiochemistry.

This paper describes the first application of a microfabricated reaction system to positron emission tomography (PET) radiochemistry. We have applied microfluidic technology to synthesise PET radiopharmaceuticals using (18)F and (124)I as labels for fluorodeoxyglucose (FDG) and Annexin-V, respectively. These reactions involved established methods of nucleophilic substitution on a mannose triflate precursor and direct iodination of the protein using iodogen as an oxidant. This has demonstrated a proof of principle of using microfluidic technology to radiochemical reactions involving low and high molecular weight compounds. Using microfluidic reactions, [(18)F]FDG was synthesised with a 50% incorporation of the available F-18 radioactivity in a very short time of 4s. The radiolabelling efficiency of (124)I Annexin-V was 40% after 1 min reaction time. Chromatographic analysis showed that such reaction yields are comparable to conventional methods, but in a much shorter time. The yields can be further improved with more optimisation of the microfluidic device itself and its fluid mixing profiles. This demonstrates the potential for this technology to have an impact on rapid and simpler radiopharmaceutical synthesis using short and medium half-life radionuclides.

Biotechnology↗

Layer-by-layer microfluidics for biomimetic three-dimensional structures.

Due to the complex structures of living systems, with size scales spanning from the micron to millimeter range, the use of microtechnology to recreate in vivo-like architecture has exciting potential applications. However, most microscale systems are two-dimensional, and few three-dimensional (3-D) systems are being explored. We have developed a versatile technique, combining surface engineering with layer-by-layer microfluidics technology, to create a 3-D microscale hierarchical tissue-like structure. The process involves immobilization of a cell-matrix assembly, cell-matrix contraction, and pressure-driven microfluidic delivery. An aminopropyltriethoxysilane-glutaraldehyde activated chip is used to effectively immobilize the cell-matrix assemblies while maintaining cell viability. Pressure-driven microfluidics is applied to transport cells-matrices with controlled flow rates, determined from dynamic flow imaging. By taking advantage of the contraction of the biopolymer matrices by cells, layer-by-layer microfluidics can be used to build multilayers of cell-matrix inside a microchannel and the thickness of each layer can be controlled down to microscale dimensions. Confocal and electron microscopy images of the final structure show a hierarchical layered cellular configuration composed of heterogeneous biomimetic materials. For a model system, a biomimetic arterial structure is formed using three types of vascular cells to mimic the 3-tunic structure found in vivo. This approach provides solutions to fabricate hierarchical "neotissues" with controlled microarchitectures and 3-D configurations of multiple cell types.

Biomimetic Materials↗

Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices.

This paper presents a microfluidic chip capable of performing precise continuous pH measurements in an automatic mode. The chip is fabricated using micro-electro-mechanical-systems (MEMS)-based techniques and incorporates polydimethylsiloxane (PDMS) microstructures, pH-sensing electrodes and pneumatic fluid-control devices. Through its enhanced microchannel design and use of pneumatic fluid-control devices, the microfluidic chip reduces the dead volume of the sample and increases the pumping rate. The maximum pumping rate of the developed micro-pump is 28 microL/min at an air pressure of 10 psi and a driving frequency of 10 Hz. The total sample volume consumed in each sensing operation is just 0.515 microL. As a result, the developed chip reduces the sample volume compared to conventional large-scale pH-sensing systems. The microfluidic chip employs the electrochemical sensing method to conduct precise pH level measurements. The sensing electrodes are fabricated by sputtering a layer of SiO(2)-LiO(2)-BaO-TiO(2)-La(2)O(3) (SLBTLO) onto platinum (Pt) electrodes and the pH value of the sample is evaluated by measuring the potential difference between the sensing electrodes and a reference electrode. Additionally, the integration of the microfluidic chip with a pneumatic fluid-control device facilitates automatic sample injection and a continuous sensing operation. The developed system provides a valuable tool with which to examine pH values in a wide range of biomedical and industrial applications.

Electrochemistry↗

A method of binding kinetics of a ligand to micropatterned proteins on a microfluidic chip.

A combination of microfluidic protein patterning and quantitative microfluidic handling has been used to analyze the binding kinetics of protein-ligand interactions on the nanoliter scale. The microfluidic handling method employing hydrophobic valving and pneumatic control allowed us to control nanoliter volumes of ligand or protein on a microfluidic chip. A hydrophobic and inert fluorocarbon thin film was patterned on a silicon nitride substrate to prevent non-specific binding on the background. Selectively patterned protein patterns of various sizes were used for quantitative analysis of the kinetic parameters of immobilized proteins on the circular patterns. As a model system, a streptavidin-patterned array of the same-sized pattern, i.e. 150 microm diameter, was used to capture FITC-BSA-biotin present in solution. The fluorescence intensity was well matched with the Langmuir isotherm model results, showing a dissociation constant of 2.43x10(-8)M. Similar streptavidin arrays with different-sized spots, ranging from 50 to 200 microm, showed a consistent dissociation constant of FITC-BSA-biotin with streptavidin pattern. Therefore, the reduction of pattern size of an immobilized protein did not change the dissociation rate of the ligand.

Biosensing Techniques↗

Bead-based microfluidic immunoassays: the next generation.

Microfluidic devices possess many advantages like high throughput, short analysis time, small volume and high sensitivity that fulfill all the important criteria of an immunoassay used for clinical diagnoses, environmental analyses and biochemical studies. These devices can be made from a few different materials, with polymers presently emerging as the most popular choice. Other than being optically clear, non-toxic and cheap, polymers can also be easily fabricated with a variety of techniques. In addition, there are many polymer surface modification methods available to improve the efficiency of these devices. Unfortunately, current microfluidic immunoassays have limited multiplexing capability compared to flow cytometric assays. Flow cytometry employ the use of encoded microbeads in contrast with normal or paramagnetic microbeads applied in current microfluidic devices. The encoded microbead is the key in providing multiplexing capability to the assay by allowing multi-analyte analysis. Using several unique sets of code, different analytes can be detected in a single assay by tracing the identity of individual beads. The same principle could be applied to microfluidic immunoassays in order to retain all the advantages of a fluidic device and significantly improve multiplexing capability.

Animals↗

Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip.

This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.

Animals↗

Applications of microfluidics in chemical biology.

This review discusses the application of microfluidics in chemical biology. It aims to introduce the reader to microfluidics, describe characteristics of microfluidic systems that are useful in studying chemical biology, and summarize recent progress at the interface of these two fields. The review concludes with an assessment of future directions and opportunities of microfluidics in chemical biology.

Automation↗

Using highly carboxylated microspheres to simplify immunoassays and enhance diffusional mixing in a microfluidic device.

Manufacturers of latex immunoassays have typically added surfactants to improve detection sensitivity and prevent non-specific aggregation of microspheres, which may cause both false positives and negatives during diagnostic testing. There is also growing interest in conducting immunoassays in smaller volumes using microfluidic devices with minimum human effort. The first goal of our study was to simplify immunoassays by eliminating the use of surfactants. Our second objective was to determine if this strategy would also enhance diffusional mixing in a microfluidic channel, which has been one of the biggest barriers to using these devices. We first ran a series of cuvette experiments to document the performance of sodium dodecyl sulfate (SDS) and polysorbate 80 (Tween 80) surfactants in a mouse immunoglobulin G (IgG) immunoassay using plain polystyrene microspheres. Next, we tested highly carboxylated microspheres with no surfactants, to determine if the same levels of accuracy and specificity could be achieved. Finally, we evaluated the surfactants and highly carboxylated microspheres in a microfluidic device. Our results show that highly carboxylated microspheres can indeed be used to replace surfactants and to induce rapid mixing via diffusion in a microfluidic device.

Carboxylic Acids↗

Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus.

The genotyping of hepatitis B virus (HBV) has become recently a valuable tool not only for epidemiological reasons but also for the clinical practice. Conventional methods for HBV genotyping typically include amplification of the target DNA sequences with a two-round nested PCR followed by separation of the amplified fragments by gel electrophoresis. A microfluidic chip that couples isotachophoresis (ITP) preconcentration and zone electrophoresis (ZE) separation may provide great advantages for sensitive, rapid and cost-effective clinical analysis. In this study, an HBV genotyping method with only one amplification round was developed by the application of the ITP-ZE chip. All the analysis steps of the ITP-ZE separation including sample injection, stacking and separation were performed continuously, controlled by sequential high-voltage switching. A 2.1cm sample plug was preconcentrated between discontinuous buffers in ITP process, followed by ZE separation. Sensitivity enhancement was obtained through the increase of sample loading volume. The average LOD value of the ITP-ZE microfluidic chip was determined to be 0.0021pg/muL. In a large-scale HBV genotyping test, single round PCR products were analyzed by ITP-ZE microfluidic chip, and the results were compared with that of the conventional method. Among the 200 cases studied, the classification rate obtained with microfluidic chip was 93%, which was 6% higher than that obtained with the conventional method. Method with ITP-ZE chip analysis provides HBV genotyping information in reduced PCR amplification time with higher detection rate when compared with conventional method. This method holds great potential for extrapolation to the abundance of similar molecular biology-based techniques in clinical diagnosis.

Base Sequence↗

Ultrafast microfluidic mixer and freeze-quenching device.

The freeze-quenching technique is extremely useful for trapping meta-stable intermediates populated during fast chemical or biochemical reactions. The application of this technique, however, is limited by the long mixing time of conventional solution mixers and the slow freezing time of cryogenic fluids. To overcome these problems, we have designed and tested a novel microfluidic silicon mixer equipped with a new freeze-quenching device, with which reactions can be followed down to 50 micros. In the microfluidic silicon mixer, seven 10-microm-diameter vertical pillars are arranged perpendicular to the flow direction and in a staggered fashion in the 450-pL mixing chamber to enhance turbulent mixing. The mixed-solution jet, with a cross section of 10 microm x 100 microm, exits from the microfluidic silicon mixer with a linear flow velocity of 20 m/s. It instantaneously freezes on one of two rotating copper wheels maintained at 77 K and is subsequently ground into an ultrafine powder. The ultrafine frozen powder exhibits excellent spectral quality and high packing factor and can be readily transferred between spectroscopic observation cells. The microfluidic mixer was tested by the reaction between azide and myoglobin at pH 5.0. It was found that complete mixing was achieved within the mixing dead time of the mixer (20 micros), and the first observable point for this coupled device was determined to be 50 micros, which is approximately 2 orders of magnitude faster than commercially available instruments.

Animals↗