PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “User experiences”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Case management of human immunodeficiency virus-infected injection drug users: a case study in Rio de Janeiro, Brazil.

The provision of care and support to persons living with human immunodeficiency virus (HIV) in Brazil who also use drugs and/or alcohol represents special challenges because of the combined effects of addiction, poverty, stigma, and discrimination. This paper presents details on a program providing both clinic- and field-based care to HIV-infected injection drug users, highlighting the use of a specialized case management approach to address the clinical and psychosocial needs of this population. This program includes both a mobile case management team that fosters group discussions and provides individual counseling, and provision of medical consultations at 2 major drug treatment centers in Rio de Janeiro. The article also describes the experience of working with injection drug users who regularly attend an outpatient clinic serving marginalized communities through the use of mutual self-help groups and specialized support groups to address to issue of adherence to antiretroviral therapies for the treatment of HIV/acquired immunodeficiency syndrome.

Acquired Immunodeficiency Syndrome↗

Users' perspectives on implantable contraceptives for women.

Users of subdermal contraceptive implants report long duration of use, convenience, and high efficacy as liked features and bleeding irregularities, weight loss/gain, and headaches as disliked effects of these methods. Satisfied users tend to be women who do not experience side effects or women who value positive features and tolerate the side effects. Satisfaction of the users is also closely related to quality of services. Service delivery problems, such as lack of proper pre-insertion counseling, inadequacy in number and imbalance in the geographical distribution of providers who can insert and remove implants, and appropriately manage side effects have been observed in new programs. Insensitivity of some providers to side-effects, such as bleeding irregularities, and to requests for removal have caused user dissatisfaction and serious public concern. Care must be taken to provide implants in a context of high quality of care with adequate numbers and distribution of trained providers and a basic record-keeping and tracking system.

Contraceptive Agents, Female↗

Community Health Centers and racial/ethnic disparities in healthy life.

This study examined disparities in health status among individuals of different racial and ethnic groups cared for by the nation's community health centers (CHCs) and compared these results with the findings for individuals using non-CHC sites as their usual source of care. The sample consisted of CHC users from the 1994 CHC User Survey and non-CHC users from the 1994 National Health Interview Survey. Bivariate comparisons were made between individuals' race/ethnicity and their experience of healthy life, an integrated measure that incorporates both activity limitation and self-perceived health status. Multiple regressions were followed to examine the independent association of race/ethnicity with healthy life experience for both CHC and non-CHC users while controlling for sociodemographic correlates of health. Among CHC users, racial and ethnic minorities did not have worse health than whites, but among non-CHC users there were significant racial and ethnic disparities: whites experienced significantly healthier life than both blacks and non-white Hispanics. These findings persisted after controlling for sociodemographic correlates of health. The results indicate that while racial/ethnic disparities in health persist nationally, these disparities do not exist within CHCs, safety-net providers with an explicit mission to serve vulnerable populations.

Adolescent↗

The imputation of motives for marijuana behavior.

The motives imputed to marijuana use and nonuse by both users and nonusers were investigated by means of open-ended questions. Verbal responses were categorized to symbolize typal vocabularies of motive, and these categories were tabulated against behavioral, social, experiential, and attitudinal variables. The results indicated that frequency of marijuana use and favorableness in drug attitude are the key factors that influence the degree to which different vocabular explanations are offered. Current users most often say that personal experience and personal reward are the motives behind use of the drug, and that legal sanctions and psychomedical effects largely account for its nonuse. Nonusers with unfavorable attitudes tend to verbalize emotional relief and psychological dependence as the motivations for use, and emotional independence for nonuse. Some of the vocabularies of both of these groups are emphasized by former users and nonusers with favorable attitudes. Interpretations of the data in terms of sociological theories of motives are presented.

Attitude↗

Development and use of a prehospital-oriented EMS computer bulletin board service.

OBJECTIVE: To describe a Level 1 trauma center's response to the need for centralized information for EMS providers by implementing a computer bulletin board service (BBS). This service permits rapid retrieval of continuing education and reference information as well as an electronic forum for EMS-related issues. METHODS: A desktop computer with a modem supporting 14.4 kbps running Remote Access v2.01 is accessed by both local and toll-free telephone numbers. Users may connect using any personal computer or terminal equipped with a modem as no proprietary formats are used. The service is available 24 hours a day, free of charge, and requires users to register online. RESULTS: The first 41 months of experience has seen 9,592 calls answered by the BBS. 1,372 users, who may be individuals or groups, have registered on the service. Usage occurs in every county in the sponsor's state. In one sample period, 49% of the activity was educationally related, followed by discussion forums (26%). The BBS is used most heavily in the afternoon and evening hours. CONCLUSIONS: A prehospital-oriented EMS BBS has seen increasing utilization in its first 41 months of existence. It has rapidly established itself as a statewide mainstay of EMS information while being inexpensive to develop and maintain. It provides focused service to a target audience and is easily accessible. The development of similar local resources elsewhere is encouraged.

Computer Systems↗

Comparing patients' experience of mental health services in England: a five-Trust survey.

The implementation of the Care Programme Approach (CPA) in English mental health services has been slow to proceed despite general support, both in England and in other countries, of its principles of good practice. This study set out to evaluate the implementation of the CPA directly from patients' experience using the "Your Treatment and Care" assessment tool. The results of a survey of 503 patients across five NHS Trusts in England showed that many patients did not have a copy of their care plan and had not been involved in the care planning procedure. Many reported shortcomings in their experience of their key worker and their psychiatrist. However, there was substantial variation in experience across services. "Your Treatment and Care" showed good internal reliability, was acceptable to users, and appeared to be able to access actual experiences better than a traditional "satisfaction" item. It appears to be very useful as a benchmarking tool and is now being used in services across the UK, the USA and Australia.

Adolescent↗

The rhyming skills of deaf children educated with phonetically augmented speechreading.

Two experiments investigated whether profoundly deaf children's rhyming ability was determined by the linguistic input that they were exposed to in their early childhood. Children educated with Cued Speech (CS) were compared to other deaf children, educated orally or with sign language. In CS, speechreading is combined with manual cues that disambiguate it. The central hypothesis is that CS allows deaf children to develop accurate phonological representations, which, in turn, assist in the emergence of accurate rhyming abilities. Experiment 1 showed that the deaf children educated early with CS performed better at rhyme judgement than did other deaf children. The performance of early CS-users was not influenced by word spelling. Experiment 2 confirmed this result in a rhyme generation task. Taken together, results support the hypothesis that rhyming ability depends on early exposure to a linguistic input specifying all phonological contrasts, independently of the modality (visual or auditory) in which this input is perceived.

Belgium↗

Database management in autoradiography.

Experiments in autoradiography involve the use of radiotracers to achieve a "functional mapping" between structures of the central nervous system and observed behavior in animals. A typical experiment produces 100-300 sections per animal. Computer systems such as DUMAS (Drexel's Unix based iMage Analysis System) are used to analyze these sections. Each section has two images associated with it--an autoradiographic image and a histological image. The latter is used to establish a correlation between anatomical structures and areas on the autoradiogram. User drawn outlines on the histological image are transferred to the autoradiographic image to obtain quantitative measures (such as average gray level). Existing systems do not take advantage of the fact that consecutive sections obtained from a brain are often similar. As a result, much of the effort involved with region outlining is repetitive. Also, the criteria for region selection varies not only across experiments, but also between users. This paper presents an approach to design an integrated database management system to manage both pictorial and quantitative data in autoradiography. Briefly, such a system is used to (a) store sets of reference outlines and images for use during the analysis of sections, (b) provide a bank of information to the user from across experiments, (c) provide an on-line help facility to the novice, and a reference guide to the expert. Based on specific requirements, we chose the relational model for data management. We developed a preliminary version of the database using INFORMIX-ESQL/C, which is a commercially available relational system. We also developed a graphics editor that is actively linked to the database. The results of our efforts have established the feasibility of using a commercially available relational system for autoradiographic data management.

Animals↗

The ambulatory treatment of noncompulsive users of psychoactive substances.

This paper presents the experience of "La Casa" Programme, a center of the University of Los Andes (Bogotá, Colombia) aimed at prevention, treatment, and research in the fields of drug addiction and AIDS. The multimodal strategy at "La Casa", ambulatory and almost free of charge, has constituted a unique approach in Colombia. The country has a heavy and specific drug consumption problem: in the last ten years the number of regular consumers of a mixture of alcohol, coca paste ("basuco")/cocaine and marihuana has increased to almost 500,000 people; state facilities and human resources are scarce, thus the importance of an appropriate use of them and search for alternatives.

Adolescent↗

A qualitative study of therapeutic effect from a user's perspective.

UNLABELLED: This study investigated the experiences of adults who have completed a course of therapy for stammering. The objective was to inform clinicians about the effect of therapy by listening to the client's own account of the experience after they had been discharged from therapy. The study involved individuals discussing their experiences and their views on the effect of therapy in an in-depth, semi-structured interview. The individual transcripts were subjected to analyses and several major themes emerged. A number of the themes had implications for clinical practice and these were considered in detail. The value of having a dialogue with clients about the effect of therapy after it has formally come to an end is discussed in relation to monitoring of therapeutic effectiveness. EDUCATIONAL OBJECTIVES: The reader will be able to: (1) describe ways of evaluating the effect of therapy; (2) summarize qualitative methodology involving interviewing techniques; (3) utilize the client experience of therapy in monitoring therapeutic effectiveness.

Adult↗

Psychiatric symptoms in cannabis users.

The usual phenomena of cannabis intoxication include experiences which in a non-intoxicated state would be considered as psychiatric symptoms. These can be distinguished from adverse reactions to cannabis, the commonest of which is an acute anxiety state. Acute psychotic episodes can also follow ingestion of the drug but are infrequent. These can be classified as acute confusional states and episodes occurring in clear consciousness. Neither presentation consistently shows enough specific features to warrant the diagnosis of 'cannabis psychosis' as a distinct clinical entity. The evidence that cannabis has a causative role in chronic psychotic or affective disorders is not convincing, although the drug may modify the course of an already established illness. Further controlled studies would be required to clarify the aetiological significance of the drug in these conditions.

Anxiety↗

[Initial experiences using SPECT cameras with multiple detector heads].

User acceptance testing of newly installed gamma cameras is mandatory in order to verify manufacturers' specifications and to ensure optimal image quality. Acceptance test procedures are widely standardized today and are carried out following commonly accepted test protocols. Two new triple head gamma cameras have been installed during the last year at the Department of Nuclear Medicine of the Vienna University Hospital. For acceptance testing of these cameras a modified and expanded version of the commonly used test protocol for single head SPECT systems has been employed. Details of the tests that have been carried out and a comparison of the results obtained for both cameras are presented. Furthermore, some specific problems that are encountered during acceptance testing of multiple head systems are discussed. In particular it has been noted that some important tests of intrinsic camera parameters cannot be carried out, which makes a complete verification of vendors' specifications impossible. In spite of these problems the acceptance test system for multiple head cameras presented in this work was sufficient for establishing proper working conditions for clinical use.

Equipment Design↗

Speech encoding strategies for multielectrode cochlear implants: a digital signal processor approach.

The following processing strategies have been implemented on an experimental laboratory system of a cochlear implant digital speech processor (CIDSP) for the Nucleus 22-channel cochlear prosthesis. The first approach (PES, Pitch Excited Sampler) is based on the maximum peak channel vocoder concept whereby the time-varying spectral energy of a number of frequency bands is transformed into electrical stimulation parameters for up to 22 electrodes. The pulse rate at any electrode is controlled by the voice pitch of the input speech signal. The second approach (CIS, Continuous Interleaved Sampler) uses a stimulation pulse rate which is independent of the input signal. The algorithm continuously scans all specified frequency bands (typically between four and 22) and samples their energy levels. As only one electrode can be stimulated at any instance of time, the maximally achievable rate of stimulation is limited by the required stimulus pulse widths (determined individually for each subject) and some additional constraints and parameters. A number of variations of the CIS approach have, therefore, been implemented which either maximize the number of quasi-simultaneous stimulation channels or the pulse rate on a reduced number of electrodes. Evaluation experiments with five experienced cochlear implant users showed significantly better performance in consonant identification tests with the new processing strategies than with the subjects' own wearable speech processors; improvements in vowel identification tasks were rarely observed. Modifications of the basic PES- and CIS strategies resulted in large variations of identification scores. Information transmission analysis of confusion matrices revealed a rather complex pattern across conditions and speech features. Optimization and fine-tuning of processing parameters for these coding strategies will require more data both from speech identification and discrimination evaluations and from psychophysical experiments.

Acoustic Stimulation↗

Hormonally impregnated intrauterine systems (IUSs), versus other forms of reversible contraceptives as effective methods of preventing pregnancy.

OBJECTIVES: To assess the contraceptive efficacy, tolerability and acceptability of hormonally impregnated intrauterine systems (IUSs) in comparison to other reversible contraceptive methods. SEARCH STRATEGY: Literature was identified through database searches, reference lists and individuals/organisations working in the field. SELECTION CRITERIA: All randomised controlled trials comparing IUSs with other forms of reversible contraceptives and reporting on pre-determined outcomes in women of reproductive years. The primary outcomes were pregnancy due to method/user failure and continuation rate. DATA COLLECTION AND ANALYSIS: The quality assessment of studies and data extraction were completed independently by two blinded reviewers. A quality checklist was designed to identify general methodological and contraceptive specific factors which could bias results. Events per women months and single decrement life table rates were extracted where possible for pregnancy, continuation, adverse events and reasons for discontinuation. Events per total number of women at follow up were collected for hormonal side effects and menstrual disturbance. When appropriate, data were pooled at the same points of follow up to calculate rate ratios in order to determine the relative effectiveness of one method compared to another. For the single decrement life table rates, the rate differences were pooled to determine the absolute difference in effectiveness of one method compared to another. Interventions were only combined if the contraceptive methods were similar. Non-hormonal IUDs were divided into three categories for the purpose of comparison with IUSs: IUDs >250mm2 (i.e. CuT 380A IUD and CuT 380 Ag IUD), IUDs <=250mm2 (i.e. Nova-T, Multiload, CuT 200 and CuT 220 IUDs) and non-medicated IUDs. MAIN RESULTS: Nineteen RCTs comparing hormonally impregnated IUSs to a reversible contraceptive method met the inclusion criteria and it was possible to include eight of these in the meta-analyses, four comparing LNG-20 IUSs with non-hormonal IUDs, one comparing the LNG-20 IUS with Norplant-2 and three comparing Progestasert with non-hormonal IUDs. No significant difference was observed between the pregnancy rates for the LNG-20 users and those for the IUD >250mm2 users. However, women using the LNG-20 IUS were significantly less likely to become pregnant than those using the IUD <=250mm2. Women using the LNG-20 IUS were more likely to experience amenorrhoea and device expulsion than women using IUDs >250mm2. LNG-20 users were significantly more likely than all the IUD users to discontinue because of hormonal side effects and menstrual disturbance, which on further breakdown of the data was due to amenorrhoea. When the LNG-20 IUS was compared to Norplant-2, the LNG-20 users were significantly more likely to experience amenorrhoea and oligomenorrhoea, but significantly less likely to experience prolonged bleeding and spotting. No other significant differences were observed. Progestasert users were significantly less likely to become pregnant and less likely to continue on the method than non-medicated IUD users after one year, but no significant differences was noted for these two outcomes when Progestasert users were compared to IUD<=250mm2 users. The only other significant differences found in the meta-analyses were that Progestasert users were less likely to expel the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWER'S CONCLUSIONS: Current evidence suggests LNG-20 IUS users are no more or less likely to have unwanted pregnancies than IUD >250mm2 and Norplant-2 users. The LNG-20 IUS was more effective in preventing either intrauterine or extrauterine pregnancies than IUDs <=250mm2. The contraceptive effectiveness of Progestasert was significantly better than non-medicated IUDs, but no difference was observed when compared to IUDs<=250mm2. Continuation of LNG-20 IUS use was similar to continuation of the non-hormonal IUDs and Norplant-2. Amenorrhoea was the main reason for the discontinuation for the LNG-20 IUS and women should be informed of this prior to starting this method.

Contraceptive Agents, Female↗

Hormonally impregnated intrauterine systems (IUSs) versus other forms of reversible contraceptives as effective methods of preventing pregnancy.

BACKGROUND: In the 1970s a new approach to the delivery of hormonal contraception was researched and developed. It was suggested that the addition of a progestogen to a non-medicated contraceptive device improved its contraceptive action. An advantage of these hormonally impregnated intrauterine systems (IUS) is that they are relatively maintenance free, with users having to consciously discontinue using them to become pregnant rather than taking a proactive daily decision to avoid conception. OBJECTIVES: To assess the contraceptive efficacy, tolerability and acceptability of hormonally impregnated intrauterine systems (IUSs) in comparison to other reversible contraceptive methods. SEARCH STRATEGY: Literature was identified through database searches, reference lists and individuals/organisations working in the field. Searches covered the period from 1972 to November 2003. SELECTION CRITERIA: All randomised controlled trials comparing IUSs with other forms of reversible contraceptives and reporting on pre-determined outcomes in women of reproductive years. The primary outcomes were pregnancy due to method/user failure and continuation rate. DATA COLLECTION AND ANALYSIS: The quality assessment of studies and data extraction were completed independently by two blinded reviewers. A quality checklist was designed to identify general methodological and contraceptive specific factors which could bias results. Events per women months and single decrement life table rates were extracted where possible for pregnancy, continuation, adverse events and reasons for discontinuation. Events per total number of women at follow up were collected for hormonal side effects and menstrual disturbance. When appropriate, data were pooled at the same points of follow up to calculate rate ratios in order to determine the relative effectiveness of one method compared to another. For the single decrement life table rates, the rate differences were pooled to determine the absolute difference in effectiveness of one method compared to another. Interventions were only combined if the contraceptive methods were similar. Non-hormonal IUDs were divided into three categories for the purpose of comparison with IUSs: IUDs >250mm2 (i.e. CuT 380A IUD and CuT 380 Ag IUD), IUDs <=250mm2 (i.e. Nova-T, Multiload, CuT 200 and CuT 220 IUDs) and non-medicated IUDs. MAIN RESULTS: Twenty-one RCTs comparing hormonally impregnated IUSs to a reversible contraceptive method met the inclusion criteria and it was possible to include eight of these in the meta-analyses, four comparing LNG-20 IUSs with non-hormonal IUDs, one comparing the LNG-20 IUS with Norplant-2 and three comparing Progestasert with non-hormonal IUDs. No significant difference was observed between the pregnancy rates for the LNG-20 users and those for the IUD >250mm2 users. However, women using the LNG-20 IUS were significantly less likely to become pregnant than those using the IUD <=250mm2. Women using the LNG-20 IUS were more likely to experience amenorrhoea and device expulsion than women using IUDs >250mm2. LNG-20 users were significantly more likely than all the IUD users to discontinue because of hormonal side effects and menstrual disturbance, which on further breakdown of the data was due to amenorrhoea. When the LNG-20 IUS was compared to Norplant-2, the LNG-20 users were significantly more likely to experience amenorrhoea and oligomenorrhoea, but significantly less likely to experience prolonged bleeding and spotting. No other significant differences were observed. Progestasert users were significantly less likely to become pregnant and less likely to continue on the method than non-medicated IUD users after one year, but no significant difference was noted for these two outcomes when Progestasert users were compared to IUD<=250mm2 users. The only other significant differences found in the meta-analyses were that Progestasert users were less likely to expel the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWERS' CONCLUSIONl the device and more likely to discontinue the method because of menstrual bleeding and pain than users of IUDs <=250mm2. REVIEWERS' CONCLUSIONS: Current evidence suggests LNG-20 IUS users are no more or less likely to have unwanted pregnancies than IUD >250mm2 and Norplant-2 users. The LNG-20 IUS was more effective in preventing either intrauterine or extrauterine pregnancies than IUDs <=250mm2. The contraceptive effectiveness of Progestasert was significantly better than non-medicated IUDs, but no difference was observed when compared to IUDs<=250mm2. Continuation of LNG-20 IUS use was similar to continuation of the non-hormonal IUDs and Norplant-2. Amenorrhoea was the main reason for the discontinuation for the LNG-20 IUS and women should be informed of this prior to starting this method.

Contraceptive Agents, Female↗

Struggling for control: the care experiences of 'difficult' patients in mental health services.

Although there is increasing recognition of the existence of 'difficult' patients who present particular challenges to mental health nurses, no research has been conducted into their perceptions of services and their experiences of care. This study identifies mental health service users who are defined by nurses as 'difficult' and explores their perceptions of their care experience. The results support earlier studies which suggested that 'difficult' patients challenge nurses' competence and control: despite their different roles both nurses and 'difficult' patients were aware of the struggle to gain or retain a notion of control. Respondents were able to identify the qualities of nurses and nursing interventions which had a positive effect on their care experience. Where nurses were perceived to demonstrate respect, time, skilled care and a willingness to give patients some control and choice in their own care, feelings of anger were reduced. These findings are discussed within the conceptual framework of 'power over' and 'power to' and implications for practice and research are considered.

Adult↗

Hearing aid users benefit from induction loop when using digital cellular phones.

OBJECTIVE: Hearing aid users have recently been reported to experience problems with electromagnetic interference when using digital cellular phones. This study was undertaken to investigate the possible benefit of an induction loop system developed for use with some cellular phone models, and also to compare the possible benefit in two languages (Finnish and American English) as well as the benefit with two hearing aid technologies (analog versus digital). DESIGN: The study was performed in controlled laboratory conditions at two tertiary care hearing health care centers, one in Oulu, Finland and the other in Dallas, in the United States. The subjects were experienced users of behind-the-ear hearing aids and served as their own controls in three different listening conditions. Thirty-two eligible subjects (20 in Oulu and 12 in Dallas) participated in three test conditions: 1. call with a landline phone, 2. call with a digital cellular phone alone and 3. call with a digital cellular phone coupled to an induction loop. RESULTS: Sentence recognition scores and subjective judgments using a visual analog scale revealed the poorest results with the digital cellular phone alone. When the induction loop was used with the digital cellular phones, sentence recognition scores and the visual analog scale scores were comparable to the scores obtained with a landline phone. The mean sentence recognition score for analog hearing aids was 62.4% (95% confidence interval 50.2 to 74.6) with the landline phone, 12.6% (-1.6 to 26.9) with the digital cellular phone alone, and 63.3% (44.2 to 82.3) when using the digital cellular phone with the induction loop. For digital hearing aids, the sentence recognition scores were 62.4% (51.9 to 72.9), 37.4% (18.0 to 56.8) and 57.6% (39.0 to 76.2), respectively. There was no significant difference in performance between the two centers. However, when using the digital cellular phone alone, there was no drop in the sentence recognition scores with the few (N = 5) digital hearing aids in Dallas. The subjects ranked the digital cellular phone alone as the poorest test condition and the digital cellular phone with an induction loop as the best. CONCLUSIONS: Induction loops appear to offer one possible solution for the incompatibility problem between hearing aids and digital cellular phones. However, the generalizability of the results must be viewed cautiously, because testing included only one induction loop and two digital cellular phone models.

Adult↗

Speech discrimination via cochlear implants with two different digital speech processing strategies: preliminary results for 7 patients.

The following processing strategies have been implemented on an experimental laboratory system of a cochlear implant digital speech processor (CIDSP) for the Nucleus 22-channel cochlear prosthesis. The first approach (PES, Pitch Excited Sampler) is based on the classical channel vocoder concept whereby the time-averaged spectral energy of a number of logarithmically spaced frequency bands is transformed into appropriate electrical stimulation parameters for up to 22 electrodes. The pulse rate at any electrode is controlled by the voice pitch of the input speech signal. The pitch extraction algorithm calculates the autocorrelation function of a lowpass-filtered segment of the speech signal and searches for a peak within a specified time window. A random pulse rate of about 150 to 250 Hz is used for unvoiced speech portions. The second approach (CIS, Continuous Interleaved Sampler) uses a stimulation pulse rate which is independent of the input signal. The algorithm scans continuously all specified frequency bands (typically between 4 and 22) and samples their energy levels. Evaluation experiments with 7 experienced cochlear implant users showed significantly better performance in consonant identification tests with the new processing strategies than with the subjects' own wearable speech processors whereas improvements in vowel identification tasks were rarely observed. Modifications of the basic PES- and CIS-strategies resulted in large variations of identification scores. Information transmission analysis of confusion matrices revealed a rather complex pattern across conditions and speech features. No final conclusions can yet be drawn. Optimization and fine-tuning of processing parameters for these coding strategies require more data both from speech identification and discrimination as well as psychophysical experiments.

Acoustic Stimulation↗