PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Compressive Strength”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

The development and characterization of a fracture-toughened acrylic for luting total joint arthroplasties.

An autopolymerizing fracture-toughened acrylic lute was developed utilizing a toughened prepolymer and a gel-polymerization method. Samples for mechanical and chemical characterization were molded from this material and from untoughened controls. Mechanical testing showed that the mode I fracture toughness (K(IC)) of the toughened lute was increased by 163% over that of the untoughened acrylic controls while the compressive strength and modulus were decreased by 36% and 34%, respectively. The flexural properties of the experimental material were not adversely affected. Analysis of molecular weight and residual monomer data for the experimental and control materials demonstrated that the increase in toughness was due to the presence of the toughened prepolymer. The use of the gel polymerization process gave excellent homogeneity with very low porosity for the experimental polymer, but it resulted in a significant increase in the residual monomer concentration due to the absence of a dispersed phase of prepolymer remnants. This raises questions concerning tissue response to the experimental system.

Arthroplasty, Replacement↗

Osseointegration of composite calcium phosphate bioceramics.

The resistance of macroporous calcium phosphate ceramics to compressive strength generally is low and depends on, among other factors, porosity percentage and pore size. A compromise always is adopted between high porosity, required for a good integration, and mechanical strength, which increases with material density. We improved the strength of macroporous calcium phosphate ceramics of interconnected porosity by filling the pores with a highly soluble, self-setting calcium phosphate cement made of TCP and DCPD. Cylinders of the resulting material were implanted in sheep condyles and subjected to histological analysis after 20, 60, and 120 days. Microradiographs were made of the histological sections. The control material consisted of ceramic that had not been loaded with cement. Progressive ingrowth of bone into the ceramic pores occurred as the cement was degraded during the first implantation period. Marked degradation of the cement was apparent after 2 months, with fragmentation of the cement in most of the pores and the presence of bone tissue between the fragments. All the cement had been replaced by bone after 4 months. Some fragments of cement still were embedded in the newly formed bone. There was no significant difference between the integration of loaded and nonloaded ceramics. Filling the macroporous ceramic pores with a calcium phosphate cement significantly improved the mechanical strength of these ceramics without modifying their integration in the healing bone.

Animals↗

Effect of sodium fluoride, calcium carbonate, and vitamin D on the skeleton in multiple myeloma.

Fifteen patients with multiple myeloma were treated with sodium fluoride (50 mg twice daily) plus calcium carbonate (1 g four times daily) or with the same fluoride-calcium dosage plus vitamin D (50,000 U twice weekly). All patients had increased bone formation, as shown by microradiography and videodensitometry. Ten patients had osteosclerosis demonstrated by roentgenograms. Compressive strength of the vertebral bodies was greater among those who received fluoride-calcium than among controls. Densitometry studies were not helpful. Side-effects were minimal and consisted of nausea and fibrositic symptoms. Hypocalcemia occurred less frequently in patients who received vitamin D along with fluoride-calcium. Administration of sodium fluoride and calcium carbonate produces an increase in bone mass and is a useful adjunct treatment for patients with multiple myeloma.

Bone Diseases↗

A new bioactive bone cement: effect of glass bead filler content on mechanical and biological properties.

A new bioactive bone cement (designated GBC), consisting of bioactive glass beads as an inorganic filler and polymethylmethacrylate (PMMA) as an organic matrix, has been developed. The purpose of the present study was to examine the effect of the amount of glass bead filler added to GBC on its mechanical and biological properties, and to decide the most suitable content of filler. Serial changes in GBC with time were also examined. The newly designed bioactive beads, consisting of MgO-CaO-SiO2-P2O5-CaF2 glass, were added to the cement in the proportions 30, 40, 50, 60, and 70 wt %. These cements were designated GBC30, GBC40, GBC50, GBC60, and GBC70, respectively. The compressive strength and the elastic modulus of bending of GBC increased as the glass bead content increased. The various types of GBC were packed into the intramedullar canals of rat tibiae to evaluate osteoconductivity, as determined by an affinity index calculated as the length of bone in direct contact with the cement expressed as a percentage of the total length of the cement surface. Rats were killed at 4 and 8 weeks after the operation and the affinity index was calculated for each type of GBC. Histologically, new bone had formed along the surface of all types of GBC within 4 weeks, even in GBC30 containing only 30 wt % of glass beads. At each time interval studied, there was a trend for the affinity index of GBC to increase as the glass bead filler content increased. There was no significant increase of affinity index between GBC60 and GBC70. The affinity indices for all types of GBC increased significantly with time up to 8 weeks. The handling properties of GBC were comparable to those of conventional PMMA bone cement. We conclude that when mechanical properties and osteoconductivity are both taken into consideration, GBC60 is the most suitable formulation; it shows excellent osteoconductivity and sufficient mechanical strength for clinical use.

Animals↗

Mechanical and rheological improvement of a calcium phosphate cement by the addition of a polymeric drug.

A polymeric acrylic system supporting a derivative of the aminosalicylic acid was incorporated in a calcium phosphate cement, with the aim not only to achieve some pharmacological effects but to obtain an improvement of its mechanical and rheological properties. It is known that, besides the analgesic and anti-inflammatory properties, the salicylic group presents a calcium complexation ability. The inorganic phase of the cement consisted of alpha-tricalcium phosphate [alpha-Ca(3)(PO(4))(2)] and precipitated hydroxyapatite added as a seed. The liquid phase was an aqueous solution of Na(2)HPO(4). The polymeric drug increased the injectability of the cement. The hydrolysis of the alpha-tricalcium phosphate into calcium-deficient hydroxyapatite proceeded at a lower rate because of the addition of the polymeric drug. As a consequence, the cement hardening was slightly slower, although the final compressive strength was 25% higher. The bending strength increased from 5 to 9 MPa with the addition of the polymeric drug. The strengthening of the structure was related to the reduction of porosity and the lower size of the precipitated crystals, as observed by scanning electron microscopy.

Biocompatible Materials↗

A bioactive glass powder-ammonium hydrogen phosphate composite for repairing bone defects.

Bioactive glass powder (AW-G) was made into a rigid compound by mixing with ammonium hydrogen phosphate and was evaluated as a bone-defect filler. The proximal metaphysis of the rat tibia was drilled and packed with (a) polymethyl-methacrylate (PMMA) bone cement, (b) AW-G powder, (c) AW-G powder with ammonium hydrogen phosphate (AW-G)-(A-P), or (d) nothing, as a control. The animals, with different implantation periods up to 24 weeks, were sacrificed and the defective sites were histologically analyzed. The results revealed direct bonding between the bone tissue and the (AW-G)-(A-P). The general inflammatory reaction of (AW-G)-(A-P) was less than that of PMMA bone cement. The compressive strength of (AW-G)-(A-P) implanted subcutaneously into rats was measured chronologically and deterioration did not occur during a period of 24 weeks. The rigidity increased to 1.6 times 6 months after implantation as compared with the initial value. This compound can be used as paste and is transformed into a rigid compound in about 4 min without noticeable elevation of the temperature. Thus, this (AW-G)-(A-P) composite can be used as a bone defect filler, and there is a possibility that it can even be used as a bone cement if higher rigidity can be attained.

Animals↗

A new bioactive bone cement: its histological and mechanical characterization.

We have developed a bioactive bone cement using CaO-SiO 2-P 2O 5-CaF 2 glass powders and ammonium phosphate solution, and investigated its histological and mechanical characteristics in vivo. A bone defect was drilled in proximal metaphysis of the rat tibia and filled with the bioactive bone cement in paste form or polymethylmethacrylate (PMMA) bone cement in the dough state. The cements were allowed to harden in situ. Histological examination demonstrated direct bonding between the new cement and bone by 4 weeks. The bioactive bone cement did not degrade up to 24 weeks postimplantation. The inflammatory reaction to the bioactive bone cement was less intense than the reaction induced by PMMA. Changes in the mechanical properties of the cement in vivo were studied by implanting hardened cylindrical specimens of both types of cement into the hindlimb muscles of rats for 12 weeks. The compressive strength of the bioactive cement increased significantly after implantation, and reached 68 MPa in 1 week and 73 MPa in 4 weeks. These values were comparable to those of PMMA, and were maintained up to 12 weeks after implantation. This bioactive bone cement hardens in situ within a few minutes with negligible rise of temperature and can be easily handled as a paste for filling bone cavities of different shapes. In addition, this cement has good osteoconductive and bone bonding potential and fairly high mechanical strength. Therefore, this new cement could be used both as a bioactive bone cement and bone defect filler.

Animals↗

A new bioactive bone cement consisting of BIS-GMA resin and bioactive glass powder.

We have developed a bioactive bone cement consisting of silane-treated CaO-SiO 2-P 2O 5-CaF 2 glass powder as the filling particles and bisphenol-a-glycidyl methacrylate (BIS-GMA) diluted with triethylene-glycol dimethacrylate (TEGDMA) as the organic matrix. Histological examination demonstrated direct bonding between the cement and bone along the circumference of the cement at 4 weeks after implantation in rat tibia. The compressive strength and toughness of the cement were two and four times greater than those of polymethylmethacrylate (PMMA) cement, respectively. The inflammatory reaction of the skin caused by the new cement was not as intense as that for PMMA 3 days after subcutaneous implantation. This new cement may be applicable as a bioactive bone cement with high mechanical strength.

Animals↗

Innovations in acrylic bone cement and application equipment.

A new bone cement was developed with the purpose of reducing the adverse biological effects during cementation of implants. This bone cement is characterized by lower exotherm, low release of monomer, low residual content of monomer, and retained physical properties. The essential innovation was substitution of half of the methylmethacrylate (MMA) in the monomer with long chain, high molecular weight, less volatile, and less soluble methacrylates (n-decylmethacrylate, isobornyl-methacrylate), as well as alteration of the accelerator system to a mix of dihydroxypropyl-p-toluidine and N,N-dimethyl-p-toluidine. The powder contains butylmethacrylate-MMA copolymers. These measures lower the glass-transition temperature, and permit more complete mixing in an integrated package, mixing, and delivery system consisting of a vacuum packed, double chamber pouch. The porosity was reduced to about 2% and the largest voids measured 0.1 mm. The polymerization exotherm was reduced to 58 degrees C. The compressive strength was 82 MPa, the four-point bending strength 55 MPa, the flexural modulus 2.24 GPa, the tensile strength 32 MPa, and the shear strength 36 MPa. The fracture toughness was 0.89 MPa square root of cm. These mechanical properties together with the fatigue life were on level with manually mixed, conventional PMMA bone cements.

Biocompatible Materials↗

New acrylic bone cements conjugated to vitamin E: curing parameters, properties, and biocompatibility.

Acrylic bone cement formulations with antioxidant character were prepared by incorporation of a methacrylic monomer derived from vitamin E (MVE). Increasing concentrations of this monomer provided decreasing peak temperature values, ranging from 62 to 36 degrees C, and increasing setting time with values between 17 and 25 min. Mechanical properties were evaluated by compression and tension tests. Compressive strength of the new formulations were superior to 70 MPa in all cases. The cement containing 25 wt % MVE, however, showed a significant decrease in tensile properties. Biocompatibility of the new formulations was studied in vitro. The analysis of the effect of leachables from cements into the media showed continued cell proliferation and cell viability with a significant increase for the cement containing 15 wt % MVE. This formulation also showed a significant increase in cellular proliferation over a period of 7 days as indicated by the Alamar Blue test. The cells were able to differentiate and express phenotypical markers in presence of all materials. A significant increase in alkaline phosphatase activity was observed on the cements prepared in presence of 15-25 wt % MVE compared with PMMA. Morphological assessment showed that the human osteoblast (HOB) cells were able to adhere, retain their morphology, and proliferate on all the cements.

Acrylates↗

A proposed specification for acrylic bone cement.

A proposed specification covering handling characteristics and physical and chemical properties of bone cement composed primarily of methyl methacrylate has been prepared on the basis of data from the authors' studies and from various other sources. Under handling characteristics, requirements included relate to dough, handling and setting time, proper plasticity for insertion and temperature rise on setting. Mechanical properties specified include compressive strength and indentation and recovery characteristics. Maximum limits are proposed for water sorption and solubility. Suggested packaging requirements are also included.

Bone Cements↗

The flow properties of dental cements.

The flow properties of several major types of dental cements were investigated using slow compressive strength and creep techniques. Considerable differences were found in their behavior. Whereas the phosphate-bonded and glass-ionomer cements exhibited brittle fracture, the other cements tended to distort to a greater or lesser extent under load. All cements showed some creep under load but the extent of this varied considerably; the creep of phosphate-bonded cements being very small and that of the eugenol and related cements considerable.

Dental Cements↗

Dynamic mechanical properties of amalgams.

A recently developed dynamic mechanical analysis technique was utilized to determine the setting rates of dental amalgams. Via a compound parallel beam apparatus the dynamic mechanical properties of five amalgam materials were continuously measured at 37 degrees C within ca. 7 min after the start of trituration. Over a 15 hr period results showed that the modulus of elasticity (Ea) increased from 1.2 X 10(10) Pa to 6.5 X 10(10) Pa--the latter generally approaching those values reported via ultrasonic techniques. Moduli results via compression tests on microspecimens (3 X 2 X 1 mm) paralleled previous reliable literature data, nominally yielding values for Ea of 2-3 X 10(10) Pa. The extent of Ea scatter from both inter- and intrapreparer experiments appeared similar, although superior technique generally could be recognized by a systematic shift of the mean results to higher Ea's. In addition to modulus studies both compressive strengths (sigma max) and their corresponding strains (epsilon) were measured on microspecimens at a strain rate (epsilon) of 0.031 min-1, with a significant increase being noted in sigma max for the one material tested at over an order of magnitude increase in epsilon.

Dental Amalgam↗

The evaluation of new dental resins prepared with polyfunctional methacrylate monomers.

The combinations of several composite fillers and dimethacrylates for crown and bridge resins were investigated. The composite filler prepared from TMPT markedly improved the mechanical and physical properties of crown and bridge resins. The enhancement of the mechanical and physical properties is due to the highly crosslinked structure which is developed with the use of the reactive composite filler which copolymerizes with the matrix monomer. The combination of the 2.6E-UDMA comonomer and the TMPT composite filler exhibited the maximum compressive strength, transverse strength, and Brinell hardness, and minimum abrasion loss and thermal expansion. This hard resin was superior to the resins currently available for clinical use.

Acrylic Resins↗

Crosslinked agarose encapsulated sorbents resistant to steam sterilization. Preparation and mechanical properties.

The application of agarose in hemoperfusion is hampered by the lack of a suitable sterilization method. A technique has been developed for the crosslinking of agarose encapsulated sorbents by the reaction with 1,3-dichloro-2-propanol (DCP) under strong alkaline conditions. A twofold molar excess of DCP with respect to agarose and an equimolar amount of sodium hydroxide at a concentration of 0.3 mol/L with a reaction time of 1-4 h at 50 degrees C are found to be the optimal conditions. The compressive strength of crosslinked beads is increased by a factor of 4. Agarose capsules are found to degrade by the influence of gamma radiation, but are resistant to steam sterilization at 134 degrees C during at least 30 min when crosslinked.

Adsorption↗

Influence of 4-methacryloxyethyl trimellitic anhydride on composites subjected to hygrothermal cycling.

Pastes were made by spatulating a hydroxyapatite powder into triethylene glycol dimethacrylate (TEGDMA) that contained benzoyl peroxide. For comparison, similar pastes included 5 wt-% 4-methacryloxyethyl trimellitic anhydride (4-META) in the TEGDMA. Composites were made by heating at 120 degrees C under pressure. Inclusion of 4-META reduced the rate of diffusion of water by about one-third, at 27 degrees C. Also after thermal cycling in water, inclusion of 4-META decreased the fractional drop in compressive strength by about one-half. Examination of fracture surfaces indicated that inclusion of 4-META improved the wetting of filler particles and gave more coherent composites. All these findings are consistent with the view that 4-META acts as a coupling agent.

Acrylates↗

A new glass-ceramic for bone replacement: evaluation of its bonding to bone tissue.

Glass powders (350 mesh) of the composition MgO, 4.6; CaO, 44.9; SiO, 34.2; PO, 16.3; CaF, 0.5 in weight ratio were compacted, heated to 1050 degrees C at a rate of 5 degrees C/min and kept at 1050 degrees C for 2 h. The resultant glass-ceramic having oxyapatite, fluoroapatite, and wollastonite crystals showed high bending and compressive strengths of 157 and 1060 MPa, respectively. The biocompatibility and bonding ability of this new glass-ceramic to the bone tissue was evaluated using rabbit tibial bones, and the failure load to break the bonding of several ceramics (the new glass-ceramic, dense hydroxyapatite, 45S5 Bioglass, alumina-ceramic) to bone tissues was measured. The new glass-ceramic showed tight bonding to bone comparable with dense hydroxyapatite, and in 25 weeks its load was 70% of that of bone tissue.

Animals↗

In vivo histologic and biomechanical characterization of a biodegradable particulate composite bone cement.

A biodegradable particulate composite bone cement consisting of a crosslinked gelatin matrix and tricalcium phosphate particles was implanted intraosseously in rabbits for up to 12 weeks. Cured cylindrical implants were inserted in holes drilled in the proximal tibial metaphysis. Sequential fluorochrome labeling and radiographs were done, and specimens were processed for decalcified and nondecalcified histology. At 4 weeks, the cross-sectional diameter of the implant was slightly greater than at implantation. There was considerable dissolution of the matrix and some new bone ingrowth. At 12 weeks, the diameter was reduced to half the original diameter and bone had grown throughout the matrix. In the distal femur, freshly mixed cement was used to stabilize an osteochondral fracture. Mechanical testing of the cement-stabilized fracture revealed a decrease in compressive strength and modulus at 4 weeks followed by an increase to greater than initial values at 12 weeks. Over time, the osteochondral fragment subsided into the underlying cement, but the subsidence did not correlate with mechanical strength. This osteochondral fracture model permits measurement of the overall material properties of a cement simultaneously weakened by resorption and reinforced by ingrowing bone.

Animals↗