PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Galactose biosensors using composite polymers to prevent interferences.

A biosensor using a composite polymer to prevent interferences was used in a flow injection analysis system for the detection of galactose in human plasma. The biosensor consisted of galactose oxidase immobilized on a platinized carbon electrode that had been modified with a composite polymer. The composite polymer showed improved selectivity to hydrogen peroxide compared with either of its individual polymeric components, Nafion and a copolymer of diaminobenzene and resorcinol. The composite polymer minimized the effect of possible interference from urate, ascorbate, and acetaminophen. This analytical system had a minimum detection limit of 50 microM, linearity to 6 mM, a storage stability of greater than 30 days, and a high sample throughput (approx. 120 samples/h).

Biosensing Techniques↗

Miniaturized thin film glutamate and glutamine biosensors.

Integrated thin film biosensors were developed for the simultaneous measurement of L-glutamine and L-glutamate in a mu-flow cell. Due to a novel glutaminase with an activity optimum in the neutral pH range, direct monitoring of glutamine in a mammalian cell culture medium could be performed. The glutamine bienzyme sensor was prepared by co-immobilization of glutaminase with glutamate oxidase within a photopatterned poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogel membrane. The sensor response was linear in the concentration range of 50 mumol to 10 mmol glutamine/l. Additionally, a glutamate biosensor was integrated on the sensor chip for difference measurement of possible glutamate interferences. The sensor-chip could be used for at least 300 measurements without any alteration in the performance of its sensors. A new sensor-chip with an integrated flow cell provided the possibility of simultaneous measurement of four different parameters at a cell volume of 1 microliter. In order to complete the microsystem, and in order to obtain a "lab on chip", a battery operated surface mounted device (SMD) potentiostat was developed.

Biosensing Techniques↗

The use of differential measurements with a glucose biosensor for interference compensation during glucose determinations by flow injection analysis.

A novel detection system for the determination of glucose in the presence of clinically important interferents, based on the use of dual sensors and flow-injection analysis (FIA), is described. The normalisation methodology involves measurement of the interference signal at a reference sensor; this signal can then be subtracted from the glucose sensor signal (post-run) to give a corrected measurement of the glucose concentration. The detection system consists of a thin layer with dual glassy carbon working electrodes. One electrode was surface modified to act as a glucose biosensor by immobilisation of glucose oxidase (GOx) (from Aspergillus niger) with 1% glutaraldehyde and bovine serum albumin. The second electrode (glucose oxidase omitted) was utilised to measure the interference signal responding only to electroactive species present in the injected sample. A computer controlled multichannel potentiostat was used for potential application and current monitoring duties. The sensor responses were saved in ASCII format to facilitate post-run analysis in Microsoft Excel. Cyclic voltammetry (CV) was utilised to investigate the manner in which the interference signal contributed to the total signal obtained at the biosensor in the presence of glucose. The kinetics parameters Imax and the apparent Michaelis-Menten constant, K'm, were calculated for the sensor operating under flow-injection conditions.

Acetaminophen↗

A microdialysis fibre based sampler for flow injection analysis: determination of L-lactate in biofluids by an electrochemically synthesised bilayer membrane based biosensor.

A microdialysis fibre based, low volume sampler is described which can be used in flow injection analysis (FIA) when an on-line dilution of the sample and/or removal of high molecular weight interferents is required. This device used in combination with a lactate amperometric biosensor based on lactate oxidase electrochemically immobilised in a bilayer membrane of poly(o-phenylendiamine) and overoxidized poly(pyrrole) permits the extension of the linear range of response up to 10 mM lactate. Combining microdialysis sampling with FIA and amperometric detection at an interference-free and fast-response biosensor, lactate determination in complex media such as serum, milk and yoghurt can be easily achieved with a high sample throughput and no sample pre-treatment.

Animals↗

The development of a new biosensor based on recombinant E. coli for the direct detection of organophosphorus neurotoxins.

A new biosensor for the direct detection of organophosphorus (OP) neurotoxins has been developed utilizing cryoimmobilized, recombinant E. coli cells capable of hydrolyzing a wide spectrum of OP pesticides and chemical warfare agents. The biological transducer was provided by the enzymatic hydrolysis of OP neurotoxins by organophosphate hydrolase which generates two protons through a reaction in which P-O, P-F, P-S or P-CN bonds are cleaved, and the proton release corresponded with the quantity of organophosphate hydrolyzed. This stoichiometric relationship permitted the creation of a potentiometric biosensor for detection of OP neurotoxins and a pH-based assay was developed as a direct function of the concentration of OP neurotoxins and the immobilized biomass. In these studies utilizing paraoxon as the substrate, neurotoxin concentration was determined with two different types of measuring units containing immobilized cells: (1) a stirred batch reactor; and (2) a flow-through column minireactor. A pH glass electrode was used as the physical transducer. The linear detection range for paraoxon spanned a concentration range of 0.25-250 ppm (0.001-1.0 mM). The response times were 10 min for the batch reactors and 20 min for the flow-through systems. It was possible to use the same biocatalyst repetitively for 25 analyses with a 10 min intermediate washing of the biocatalyst required for reestablishing the starting conditions. The cryoimmobilized E. coli cells exhibited stable hydrolytic activity for over 2 months under storage in 50 mM potassiumphosphate buffer at +4 degrees C and provide the potential for the development of a stable biotransducer for detecting various OP neurotoxins.

Biosensing Techniques↗

Development of an ultra high sensitive tissue biosensor for determination of swellfish poisoning, tetrodotoxin.

A simple tissue biosensor for measuring Na+ channel blockers such as tetrodotoxin (TTX) and saxitoxin (STX) has been developed. The membrane of frog bladder has Na+ channels which control the passage of Na+. It is well known that TTX blocks Na+ channels. The tissue biosensor consists of a Na+ electrode integrated within a flow cell. The tip of the electrode was covered with frog bladder membrane sandwiched between two sheets of cellulose acetate membrane, and the electrode was set in a flow cell. A solution of 8% NaCl was carried in the cell and the output of the electrode allowed to stabilize. TTX was injected into the sensor system and measured from the inhibition ratio of the sensor peak output. One assay took approximately 5 min. The lower limit of detection was 86 fg. The continuous determination of TTX was feasible for 250 h in the presence of 0.003% NaN3. A Linear correlation was obtained between TTX activities of F-niphobles and F-parudale determined by the methods of TTX sensor and mouse assay.

Animals↗

Poly(methylene blue)-modified thick-film gold electrodes for the electrocatalytic oxidation of NADH and their application in glucose biosensors.

Electropolymerization of the phenothiazine derivative methylene blue (MB) on screen-printed, thick-film gold electrodes leads to electrocatalytically active and conducting layers of poly(methylene blue) (PMB) in intimate and stable contact with the electrode surface. The catalytic properties of the PMB films allow anodic oxidation of NADH at potentials as low as +200 mV vs. the saturated calomel electrode (SCE) reducing interferences from cooxidizable species as well as minimizing electrode fouling by enabling a simultaneous two-electron transfer mechanism. Dehydrogenase-based biosensors employing PMB-modified thick-film electrodes are obtained either by entrapment of the enzyme into the PMB layer itself or by laminating an enzyme membrane made of an aqueous poly(vinylacetate) dispersion over the PMB-modified electrode. Both methods are used to fabricate glucose biosensors which can be operated at low overpotentials, i.e. +200 mV vs. SCE.

Biosensing Techniques↗

A new approach for creating double-stranded DNA biosensors.

The principle of 'sandwich'-type biosensors based on liquid-crystalline dispersions formed from [DNA-polycation] complexes is outlined. These biosensors will find application in the determination of a range of compounds and physical factors that affect the ability of a given polycationic molecule to maintain intermolecular crosslinks between neighbouring DNA molecules. In the case of liquid-crystalline dispersions formed from [DNA-protamine] complexes, the lowest concentration of hydrolytic enzyme (trypsin) detectable was approximately 10-(14) M.

Animals↗

Biosensors for fermentation control.

Over the past year, biosensor development has been an active area of research. The actual application of biosensors in process monitoring and control is limited to a few cases, mainly as a result of difficulties relating to their long-range stability and their sensitivity to interfering compounds. Steam sterilization is no longer a problem though, as the great majority of sensors are part of flow-injection analysis systems.

Amino Acids↗

A cell-free biosensor for the detection of transcriptional inducers using firefly luciferase as a reporter.

A cell-free biosensor for the detection of transcription induction by specific small-molecule ligands is presented. As model systems, tetracycline and mercury-inducible promoters were used containing firefly luciferase as reporter gene. Escherichia coli S30 extract was prepared and used for coupled transcription-translation reactions. By using purified Tet repressor and MerR regulatory proteins, we could study repressor-operator interactions for optimizing the relative concentrations of each component. Previously, detection of tetracycline and mercury using similar transcriptional regulation in whole living cells has been carried out. As compared to whole-cell biosensors, our results showed better sensitivity for the detection of tetracycline and the toxic effect of mercury was avoided in the cell-free system. Also, as the system omits cell cultivation and bacterial membranes as molecule passage inhibitors, it is possible to carry out assays in much shorter times and without the use of genetically modified organisms.

Animals↗

Sensitivity-enhancement of wavelength-modulation surface plasmon resonance biosensor for human complement factor 4.

Sandwich and colloidal Au techniques for enhancing the sensitivity of a wavelength-modulation surface plasmon resonance (SPR) immunosensor are demonstrated by the detection of human complement factor 4 (C4). The design of the wavelength-modulation SPR biosensor is based on fixing the incident angle of light and measuring the reflected intensity of light in the wavelength range spanning 500-900 nm simultaneously. The human C4 had good response in the concentration range 2-20 microg/mL in the direct assay. However, in the sandwich assay, the human C4 had good response in the concentration range 0.2-20 microg/mL and the lowest concentration is 10-fold lower than that obtained by the direct assay. With human C4-Au colloidal conjugate, the human C4 had good response in the concentration range 0.1-20 microg/mL and the lowest concentration is 20-fold lower than that obtained by the direct assay. In the colloidal-Au-enhanced sandwich assay, the human C4 had good response in the concentration range 0.05-5 microg/mL and the lowest concentration is 40-fold lower than that obtained by the direct assay. Under selected experimental conditions, the reproducibility, sensitivity, and reversibility of the enhanced SPR immunoassay are very satisfactory. The results represent potentially significant advantages in the sensitivity of SPR biosensors.

Antibodies↗

Studies of substrate-induced conformational changes in human cytomegalovirus protease using optical biosensor technology.

The interaction between human cytomegalovirus (HCMV) protease and a peptide substrate was studied using a surface plasmon resonance (SPR)-based biosensor. Immobilization of the enzyme to the sensor chip surface by amine coupling resulted in an active enzyme with a higher catalytic efficiency than the enzyme in solution, primarily due to a lower K(m) value. The interaction between immobilized protease and substrate was characterized by a biphasic SPR signal. Rate constants for the formation of the initial enzyme-substrate complex could be determined from the sensorgrams. Simulated binding curves based on the determined k(cat) and the rate constants indicated that the complex binding signal did not originate from the accumulation of intermediates in the catalytic reaction. By chemical crosslinking of the immobilized HCMV protease, which was shown to limit the enzyme's structural flexibility, it was revealed that the obtained sensorgrams were composed of a signal caused by substrate binding and considerable structural alterations in the immobilized enzyme. Furthermore, HCMV protease was inactivated by chemical crosslinking, indicating that structural flexibility is essential for this enzyme. Parallel experiments with immobilized alpha-chymotrypsin revealed that it does not undergo similar conformational changes on peptide binding and that crosslinking did not inactivate the enzyme. The simultaneous detection of binding and conformational changes using optical biosensor technology is expected to be of importance for further characterization of the enzymatic properties of HCMV protease and for identification of inhibitors of this enzyme. It can also be of use for studies of other flexible proteins.

Catalysis↗

Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.

A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.

Biosensing Techniques↗

A mediatorless biosensor for putrescine using multiwalled carbon nanotubes.

Poly(diallyldimethylammonium) chloride, having a capability of dispersing multiwalled carbon nanotubes (MWCNTs), permits the modification of electrode surfaces. Together with putrescine oxidase, a MWCNT modified glassy carbon electrode was constructed for the development of a mediatorless putrescine biosensor. Nanoscale "dendrites" of MWCNTs were reasoned to form a network, projecting outward from the electrode surface acting like bundled ultra-microelectrodes, thereby permitting access to the active site and facilitating direct electron transfer to the immobilized enzyme. Our biosensor was capable of efficiently monitoring the direct electroactivity of putrescine oxidase at the electrode surface. Direct electron transfer permits the detection of putrescine at negative potentials, circumventing the interference of endogenous ascorbic and uric acids, which often complicate the analysis of important compounds in plasma. Compared with the most common interfering species, such as spermine, spermidine, cadaverine, and histamine, a detection limit of 5 microM and a response 20 times greater were found for putrescine. Tests performed on plasma of cancerous mice demonstrated that the detection of putrescine could be carried out very quickly on mammalian plasma without previous purification.

Animals↗

Rapid and highly sensitive electrochemical determination of alkaline phosphatase using a composite tyrosinase biosensor.

The use of an amperometric graphite-Teflon composite tyrosinase biosensor for the rapid monitoring of alkaline phosphatase (ALP), with no need of an incubation step and using phenyl phosphate as the substrate, is reported. Phenol generated by the action of ALP is monitored at the tyrosinase composite electrode through the electrochemical reduction of the o-quinone produced to catechol, which produces a cycle between the tyrosinase substrate and the electroactive product, giving rise to the amplification of the biosensor response and to the sensitive detection of ALP. The current was measured at -0.10 V 5 min after the addition of ALP. As a compromise between high ALP activity and high sensitivity for the detection of phenol, a pH of 8.5 was chosen. The substrate concentration was also optimized. A linear calibration plot was obtained for ALP between 2.0 x 10(-13) and 2.5 x 10(-11), with a detection limit of 6.7 x 10(-14) M. Different types of milk were analyzed with good results, using an extremely simple and rapid procedure.

Agaricales↗

Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix.

A quartz crystal microbalance (QCM) cell biosensor utilizing living endothelial cells (ECs) or human breast cancer cells (MCF-7) adhering to the gold QCM surface was used to study the relative contributions of the cells and their underlying extracellular matrix (ECM) to the measured QCM Deltaf and DeltaR shifts. The ECM represents a natural biomaterial that is synthesized by the cells to enable their attachment to surfaces. We followed the detachment of the ECs or MCF-7 cells from their ECM using a nonproteolytic method and were able to apportion the total frequency, Deltaf, decrease of the biosensor into contributions from cell attachment and from the intact underlying ECM. We also demonstrated that the Deltaf shift remaining after EC removal corresponds to ECM as determined by light microscopic visualization of the stained protein. During the process of cell detachment, we observed a novel transient increase in viscoelastic behavior expressed as a transient increase in the motional resistance, DeltaR, parameter. Then we showed via a simulation experiment using ECs stained with fluorescent rhodamine-labeled phalloidin, an actin stain, that the transient viscoelastic increase correlated with cellular stress exhibited by the cells during removal with ethylene glycol bis(2-aminoethyl ether)-N,N,N',N'- tetraacetic acid. Prior to cells lifting from their ECM, the attached ECs rearrange their actin microfilaments first into peripheral stress fibers and second into internal aggregates, to maintain cell-cell connectivity, retain their spread morphology, and attempt to adhere more tightly to their underlying ECM. The decrease in DeltaR following its transient rise corresponds to cells finally losing their attachment focal points and lifting from the ECM. We also characterized the normalized f shifts, -Delta(Deltaf)(ECM)/attached cell and -Delta(Deltaf)(cells)/attached cell, as a function of varying the number of adherent cells. Finally, we demonstrate that the underlying native ECM biomaterial, from which all cells have been removed, does not exhibit any significant level of energy dissipation, in contrast to the cells when they are attached to the ECM.

Biosensing Techniques↗

A biosensor for estrogenic substances using the quartz crystal microbalance.

This article describes a biosensor that detects estrogenic substances using a quartz crystal microbalance with a genetically engineered construct of the hormone-binding domain of the alpha-estrogen receptor. The receptor was immobilized to a piezoelectric quartz crystal via a single exposed cysteine, forming a uniform orientation on the crystal surface. Our results illustrate that this sensor responds to a variety of ligands that are known to bind to the estrogen receptor. No response was observed for nonbinding substances such as testosterone and progesterone. The sensitive response of this biosensor to estrogenic substances results from changes in the structural rigidity of the immobilized receptor that occurs with ligand binding. Agonist and antagonist show different responses.

Biosensing Techniques↗

A biosensor-based approach toward purification and crystallization of G protein-coupled receptors.

Biacore technology was used to develop an affinity purification method and screen cocrystallization conditions for the chemokine receptor CCR5. We characterized the binding of nine HIV gp120 variants and identified a truncated construct (YU2DV1V2) that bound CCR5 independent of CD4. This construct was used in an affinity purification step to improve the activity of detergent-solubilized receptor by approximately 300%. The biosensor was also used to screen receptor binding activity automatically under 50 different crystallization conditions. We found that high-molecular-weight polyethylene glycols (PEGs 4,000 and 8,000 Da) most often stabilized the receptor and improved complex formation with potential cocrystallization partners such as conformationally sensitive monoclonal antibodies and gp120. Our results show how biosensors can provide unique insights into receptor purification methods and reveal the effects of crystallization conditions on complex formation. Importantly, these methods can be readily applied to other systems.

Antibodies, Monoclonal↗