PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Analysis of some pesticides in water samples using solid-phase microextraction-gas chromatography with different mass spectrometric techniques.

A solid-phase microextraction (SPME)-GC procedure has been developed for the analysis of four selected pesticides (propanil, acetochlor, myclobutanil and fenoxycarb) in water samples. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS system and an ion trap operating in the MS-MS mode, were compared. A Carbowax-divinylbenzene SPME fiber was used. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.1-10 microg/l in water samples) and sensitivity (limits of detection were in the low ng/l range); the quadrupole MS instrument gave better precision than the ion trap MS-MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (<15%). Specificity with these two instruments was comparable in the analysis of ground water samples. Recovery tests were made to assess the applicability of the SPME procedure in the quantitative analysis of contaminated groundwaters.

Carbamates↗

Speciation of dimethylarsinic acid and monomethylarsonic acid by solid-phase microextraction-gas chromatography-ion trap mass spectrometry.

A solid-phase microextraction (SPME) method has been developed to determine two methylated arsenic species in human urine samples by GC-MS. The direct extraction of the methyl arsenic compounds by SPME after thioglycol methylate derivatization was studied. Direct extraction with SPME was suitable for the determination of trace levels of dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) in urine samples. Four different commercial SPME fibers were tested for the extraction of methyl arsenic compounds, and the best results were obtained using the polydimethylsiloxane coating. The extraction and desorption time profiles of DMA and MMA were determined. The detection limits for DMA and MMA using the SPME-GC-MS method were 0.12 and 0.29 ng/ml, respectively. The method is linear in the 1 to 200 ng/ml range.

Arsenicals↗

Analysis of tetrahydrofuran and methanol in distillation residue samples by automated headspace solid-phase microextraction-gas chromatography with flame ionization detection

Automated headspace solid-phase microextraction (SPME) coupled with gas chromatography and flame ionization detection is used to determine the amounts of methanol and tetrahydrofuran (THF) in distillation residue samples from a proprietary chemical reaction. A 65-micron polydimethylsiloxane/divinylbenzene SPME fiber is used to perform the extractions. Optimized extraction conditions for each analyte are determined using a parts-per-million-level methanol in water standard and a parts-per-billion-level THF in water standard. The amount of methanol and THF in distillation residue samples is quantitated by both standard addition and external standard calibration curve. The two methods of quantitation are compared.

Journal Article↗

Characterization of three agave species by gas chromatography and solid-phase microextraction-gas chromatography-mass spectrometry.

Steam distillation (SD) extraction-solid-phase microextraction coupled to GC-MS was developed for the determination of terpenes and Bligh-Dyer extraction-derivatization coupled with GC for the determination of fatty acids such as ethyl esters were used. It was found that the three different Agave species have the same profile of fatty acids; the quantity of these compounds is different in each Agave variety. On the other hand, different terpenes were identified in the three Agave plants studied: nine in A. salmiana, eight in A. angustifolia and 32 in A. tequilana Weber var. azul.

Agave↗

Enantiomeric determination of amphetamines: exploring a novel one-step solid-phase microextraction-based approach.

The recent advances in fiber manufacturing technology, solid-phase microextraction (SPME) is now widely studied for its effectiveness for the pretreatment of various categories of samples. This study explores a novel SPME approach for enantiomeric analysis of amphetamines, in which absorption/derivatization are accomplished in one step. Specifically, (S)-(-)-N-(Trifluoroacetyl)-prolyl chloride was adopted as the chiral derivatizing reagent and added directly into the sample matrix. Analytical parameters, such as temperature, absorption/desorption duration, and the amount of derivatizing reagent, were studied to determine their effects on the yield of analytes. The derivatization products resulting from this study show excellent desorption characteristics on the polydimethylsiloxane-coated fiber adopted in this study. Optimal operational parameters (absorption: 70 degrees C for 10 min; injection: 250 degrees C for 5 min) cause minimal negative impact on the fiber, allowing repeated use of the fiber for more than 30 times. For quantitation, data were collected under selected ion monitoring (SIM) mode using m/z 237 and 251 to designate derivatized amphetamine and methamphetamine. This method was evaluated and proved to be effective in (a) quantitative determination of the enantiomeric pairs of amphetamine and methamphetamine--in terms of repeatability, linearity, and limits of detection and quantitation; and (b) generating case-specimen data comparable to those derived from a conventional Liquid-liquid extraction approach. Good linearity for the calibration curves were established in the range of 1000-50 ng/mL for both analytes. The limits of detection for these analytes were 30 ng/mL.

Amphetamines↗

Simultaneous determination of cyanogen chloride and cyanogen bromide in treated water at sub-microg/L levels by a new solid-phase microextraction-gas chromatographic-electron-capture detection method.

A headspace solid-phase microextraction (HS-SPME) procedure has been developed and applied for the determination of cyanogen halides in treated water samples at microg/L concentrations. Several SPME coatings were tested, the divinylbenzene-Carboxen-polydimethylsiloxane fiber being the most appropriate coating. GC-electron-capture detection was used for separation and quantitation. Experimental parameters such as sample volume, addition of a salt, extraction time and desorption conditions were studied. The optimized method has an acceptable linearity, good precision, with RSD values <10% for both compounds, and it is sufficiently sensitive to detect ng/L levels. HS-SPME was compared with liquid-liquid microextraction (US Environmental Protection Agency Method 551.1) for the analysis of spiked ultrapure and granular activated carbon filtered water samples. There was good agreement between the results from both methods. Finally, the optimized procedure was applied to determine both compounds at the Barcelona water treatment plant (N.E. Spain). Cyanogen chloride in treated water was <1.0 microg/L and cyanogen bromide ranged from 3.2 to 6.4 microg/L.

Adsorption↗

Solvent-free method for the determination of polynuclear aromatic hydrocarbons in waste water by solid-phase microextraction-high-performance liquid chromatography with photodiode-array detection.

Solid-phase microextraction (SPME) has rapidly been established among the practical alternatives for sample preparation for gas chromatography. Nevertheless polynuclear aromatic hydrocarbons (PAHs) are more effectively monitored by high-performance liquid chromatography (HPLC), but initially, there was no simple way to introduce analytes extracted by SPME into an HPLC system. A SPME-HPLC interface was developed by Supelco, which enables one to take advantages of the time and solvent savings offered by SPME. In the present work six PAHs from the European Union directives: fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene were evaluated after optimization of a sample preparation method with a 100-micron poly(dimethylsiloxane) fiber. Repeatability, reproducibility, correlation coefficients, linearity, recoveries and limits of detection where determined and are indicated.

Chromatography, High Pressure Liquid↗

Automation of solid-phase microextraction-gas chromatography-mass spectrometry extraction of eucalyptus volatiles.

Solid-phase microextraction (SPME) coupled with gas chromatography (GC)-ion-trap mass spectrometry (ITMS) is employed to analyze fragrance compounds from different species of eucalyptus trees: Eucalyptus dunnii, Eucalyptus saligna, Eucalyptus grandis, and hybrids of other species. The analyses are performed using an automated system for preincubation, extraction, injection, and analysis of samples. The autosampler used is a CombiPAL and has much flexibility for the development of SPME methods and accommodates a variety of vial sizes. For automated fragrance analysis the 10- and 20-mL vials are the most appropriate. The chromatographic separation and identification of the analytes are performed with a Varian Saturn 4D GC-ITMS using an HP-5MS capillary column. Several compounds of eucalyptus volatiles are identified, with good reproducibility for both the peak areas and retention times. Equilibrium extraction provides maximal sensitivity but requires additional consideration for the effect of carryover. Preequilibrium extraction allows good sensitivity with minimal carryover.

Eucalyptus↗

Development and application of porous membrane-protected carbon nanotube micro-solid-phase extraction combined with gas chromatography/mass spectrometry.

A novel, multiwalled carbon nanotube (MWCNT)-supported micro-solid-phase extraction (mu-SPE) procedure has been developed. A 6-mg sample of MWCNTs was packed inside a (2 cm x 1.5 cm) sheet of porous polypropylene membrane whose edges were heat-sealed to secure the contents. The mu-SPE device, which was wetted with dichloromethane, was then placed in a stirred sewage sludge sample solution to extract organophosporous pesticides, used here as model compounds. Tumbling of the extraction device within the sample solution facilitated extraction, and the porous membrane acted as a filter to exclude the extraction of extraneous materials. After extraction, analytes were desorbed in hexane and analyzed using gas chromatography/mass spectrometry. Since the porous membrane afforded protection of the MWCNTs, no further cleanup of the extract was required. The pi-pi electrostatic interaction with the analytes and the large surface area of MWCNTs facilitated the adsorption of analytes, with good selectivity and reproducibility. Under the optimized extraction conditions, the method showed good linearity in the range of 0.1-50 mug/L, repeatability of the extractions (RSD 2-8%, n = 4), and low limits of detection (1-7 pg/g). No analyte carryover effect was observed, and each mu-SPE device could be used for up to 30 extractions. Comparison was made with hollow fiber protected solid-phase microextraction and headspace solid-phase microextraction; mu-SPE was demonstrated to be a fast, accurate, and cost-effective pretreatment method for sewage sludge samples.

Journal Article↗

Supercritical fluid extraction of steroids from biological samples and first experience with solid-phase microextraction-liquid chromatography.

Modern extraction techniques, supercritical fluid extraction (SFE) and solid-phase microextraction (SPME) were used for isolation of four corticosteroids from biological matrices. SFE was applied for extraction from solid matrices--hydromatrix and pig muscle. The effects of various extraction conditions were studied. Good recoveries of corticosteroids from hydromatrix were obtained under moderate extraction conditions and without modification of carbon dioxide. On the contrary, the best recoveries from spiked pig muscle were obtained with modified carbon dioxide. SPME was used for extraction from liquid samples--water and urine. The eventuality of the use of this fast solvent-free technique in steroid analysis is demonstrated. Several extraction conditions were optimized. Extracted steroids were analyzed by HPLC-UV and a special SPME-HPLC interface was used for combination with SPME.

Adrenal Cortex Hormones↗

Simultaneous analysis of thiols, sulphides and disulphides in wine aroma by headspace solid-phase microextraction-gas chromatography.

This paper deals with the improvement of a headspace solid-phase microextraction (HS-SPME) method, developed in a previous work, in order to analyse, simultaneously, thiols, sulphides and disulphides in wines. This can be achieved by applying Carboxen-polydimethylsiloxane fibres and a cryogenic trap to focus the analytes. Under optimum conditions, the HS-SPME procedure developed shows low limits of detection for the sulphides and disulphides studied (0.05-3 micrograms/l) and the thiols can also be analysed and detected at very low levels (0.5-1 microgram/l) with acceptable recoveries and repeatability.

Chromatography, Gas↗

Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis.

In-tube solid-phase microextraction (SPME) is an automated version of SPME that can be easily coupled to a conventional HPLC autosampler for on-line sample preparation, separation and quantitation. It has been termed "in-tube" SPME because the extraction phase is coated inside a section of fused-silica tubing rather than coated on the surface of a fused-silica rod as in the conventional syringe-like SPME device. The new in-tube SPME technique has been demonstrated as a very efficient extraction method for the analysis of polar and thermally labile analytes. The in-tube SPME-HPLC method used with the FAMOS autosampler from LC Packings was developed for detecting polar carbamate pesticides in clean water samples. The main parameters relating to the extraction and desorption processes of in-tube SPME (selection of coatings, aspirate/dispense steps, selection of the desorption solvents, and the efficiency of desorption solvent, etc.) were investigated. The method was evaluated according to the reproducibility, linear range and limit of detection. This method is simple, effective, reproducible and sensitive. The relative standard deviation for all the carbamates investigated was between 1.7 and 5.3%. The method showed good linearity between 5 and 10000 microg/l with correlation coefficients between 0.9824 and 0.9995. For the carbamates studied, the limits of detection observed are lower than or similar to that of US Environmental Protection Agency or National Pesticide Survey methods. Detection of carbaryl present in clean water samples at 1 microg/l is possible.

Carbamates↗

Solid-phase microextraction-gas chromatography-mass spectrometry of biologically active substances in water samples.

A solid-phase microextraction (SPME) method for determining trace amounts of polar, biologically active substances in water systems was developed and compared with solid-phase extraction followed by derivatization and GC-MS. SPME was examined with respect to the simultaneous determination of pharmaceuticals such as ibuprofen, paracetamol, phenazone, carbamazepine, and nonylphenols known to be xenoestrogens. The extraction performance of different SPME fibre coatings was studied. Coatings like polyacrylate and Carbowax-divinylbenzene proved to be the best suited. The optimum extraction time was found to be 30 min and the detection limits were between 0.2 and 50 microg/l. Low concentrations of accompanying organic matter did not impair these limits. One of the main pharmaceutical contaminants found in ground and river water around Leipzig (Germany) was ibuprofen, with a concentration in the ng/l range. The enantioselective metabolism of ibuprofen was investigated.

Estrogens↗

[Determination of organophosphorous pesticide residues in red wine by solid phase microextraction-gas chromatography].

A method for the determination of 12 organophosphorus pesticide residues (OPs) in red wine by fiber solid phase microextraction (SPME) coupled with gas chromatography (GC) was developed and validated. The SPME phase was prepared by sol-gel technology of physical incorporation. The extraction conditions were optimized with the results of stirring rate of 1,250 r/min, NaCl mass concentration of 150 g/L, and extraction time of 30 min. With the sample volume of 25 mL, the relative standard deviations (RSD) of peak areas for most of OPs were below 5%, and the detection limits of OPs were in the range of 5 ng/L-0.38 microg/L. It can be seen from the results that this method has the potential to analyze OPs in other beverages and soft drinking materials.

Beverages↗

Comparison of chloride- and hydride-generation for quantitation of germanium by headspace solid-phase microextraction-inductively coupled plasma-mass spectrometry.

Chloride- and hydride-generation headspace solid-phase microextraction (SPME) techniques have been compared for the detection of trace amounts of germanium by inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS). The conditions for generation of germanium chloride, including acid type and concentration, effect of sodium chloride and extraction time, were investigated. Detection limits of 20 and 92 pg mL(-1) and precisions of 18% (n=11) and 9.7% (n=11) were achieved for chloride and hydride generation, respectively, at a concentration of 10 ng mL(-1). The generated germanium chloride and hydride species identities were characterized and confirmed as GeCl(4) and GeH(4) by use of electron-impact ionization mass spectrometry. Chloride generation coupled with SPME sampling and ICP-TOFMS detection resulted in twofold enhancement of sensitivity compared to GeH(4)and detection limits for continuous hydride generation were 20-fold better than reported atomic fluorescence data.

Journal Article↗

Solid-phase microextraction-gas chromatographic determination of volatile monoaromatic hydrocarbons in soil.

Benzene, toluene, ethylbenzene, three isomers of xylene, and cumene have been isolated and enriched from soil samples by a combination of water extraction at room and elevated temperature and headspace-solid-phase microextraction before their gas chromatographic-mass spectrometric (GC-MS) determination. The conditions used for all stages of sample preparation and chromatographic analysis were optimized. Analytes sampled on a polydimethylsiloxane-coated solid-phase microextraction fiber were thermally desorbed in the split/splitless injector of a gas chromatograph (GC) coupled with a mass spectrometer (MS). The desorption temperature was optimized. The GC separation was performed in a capillary column. Detection limits were found to be of the order of ca. 1 ng g(-1). Relative recoveries of the analytes from soils were found to be highly dependent on soil organic-matter content and on compound identity; they ranged from ca 92 to 96% for sandy soil (extraction at room temperature) and from ca 27 to 55% for peaty soil (extraction at elevated temperature). A few real-world soil samples were analyzed; the individual monoaromatic hydrocarbon content ranged from below detection limits to 6.4 ng g(-1) for benzene and 8.1 for the total of p- + m-xylene.

Journal Article↗

Determination of bisphenol-type contaminants from food packaging materials in aqueous foods by solid-phase microextraction-high-performance liquid chromatography.

A fast screening method consisting of off-line solid-phase microextraction coupled to HPLC and fluorescence detection, suitable for the analysis of several bisphenol derivatives and their degradation products in aqueous solution, has been developed. Detection limits of 0.7 ng ml(-1) for 2,2-bis[4-(glycidyloxy)phenyl]propane, 0.9 ng ml(-1) for bisphenol A bis(3-chloro-2-hydroxypropyl)ether, 1.1 ng ml(-1) for 2,2-bis(4-hydroxyphenyl)propane and 2.4 ng ml(-1) for bisphenol F diglycidyl ether have been achieved working in the linear range 10-500 ng ml(-1). The good analytical features achieved make the proposed method an interesting option for the direct determination of these compounds in aqueous canned food such as peas, tuna, olives, maize, artichokes or palm hearts. Both the optimization process and the results, including the analysis of real samples, are given and discussed.

Benzhydryl Compounds↗

Development of a solid-phase microextraction-based method for sampling of persistent chlorinated hydrocarbons in an urbanized coastal environment.

Solid-phase microextraction (SPME) has been used as an in situ sampling technique for a wide range of volatile organic chemicals, but SPME field sampling of nonvolatile organic pollutants has not been reported. This paper describes the development of an SPME-based sampling method employing a poly(dimethylsiloxane) (PDMS)-coated (100-microm thickness) fiber as the sorbent phase. The laboratory-calibrated PDMS-coated fibers were used to construct SPME samplers, and field tests were conducted at three coastal locations off southern California to determine the equilibrium sampling time and compare the efficacy of the SPME samplers with that of an Infiltrex 100 water pumping system (Axys Environmental Systems Ltd., Sidney, British Columbia, Canada). p,p'-DDE and o,p'-DDE were the components consistently detected in the SPME samples among 42 polychlorinated biphenyl congeners and 17 chlorinated pesticidestargeted. SPME samplers deployed attwo locations with moderate and high levels of contamination for 18 and 30 d, respectively, attained statistically identical concentrations of p,p'-DDE and o,p'-DDE. In addition, SPME samplers deployed for 23 and 43 d, respectively, at a location of low contamination also contained statistically identical concentrations of p,p'-DDE. These results indicate that equilibrium could be reached within 18 to 23 d. The concentrations of p,p'-DDE, o,p'-DDE, or p,p'-DDD obtained with the SPME samplers and the Infiltrex 100 system were virtually identical. In particular, two water column concentration profiles of p,p'-DDE and o,p'-DDE acquired by the SPME samplers at a highly contaminated site on the Palos Verdes Shelf overlapped with the profiles obtained by the Infiltrex 100 system in 1997. The field tests not only reveal the advantages of the SPME samplers compared to the Infiltrex 100 system and other integrative passive devices but also indicate the need to improve the sensitivity of the SPME-based sampling technique.

Chromatography, Gas↗