PubMed Health⌕ Search

PubMed · 15575294

Development of a solid-phase microextraction-based method for sampling of persistent chlorinated hydrocarbons in an urbanized coastal environment.

Abstract

Solid-phase microextraction (SPME) has been used as an in situ sampling technique for a wide range of volatile organic chemicals, but SPME field sampling of nonvolatile organic pollutants has not been reported. This paper describes the development of an SPME-based sampling method employing a poly(dimethylsiloxane) (PDMS)-coated (100-microm thickness) fiber as the sorbent phase. The laboratory-calibrated PDMS-coated fibers were used to construct SPME samplers, and field tests were conducted at three coastal locations off southern California to determine the equilibrium sampling time and compare the efficacy of the SPME samplers with that of an Infiltrex 100 water pumping system (Axys Environmental Systems Ltd., Sidney, British Columbia, Canada). p,p'-DDE and o,p'-DDE were the components consistently detected in the SPME samples among 42 polychlorinated biphenyl congeners and 17 chlorinated pesticidestargeted. SPME samplers deployed attwo locations with moderate and high levels of contamination for 18 and 30 d, respectively, attained statistically identical concentrations of p,p'-DDE and o,p'-DDE. In addition, SPME samplers deployed for 23 and 43 d, respectively, at a location of low contamination also contained statistically identical concentrations of p,p'-DDE. These results indicate that equilibrium could be reached within 18 to 23 d. The concentrations of p,p'-DDE, o,p'-DDE, or p,p'-DDD obtained with the SPME samplers and the Infiltrex 100 system were virtually identical. In particular, two water column concentration profiles of p,p'-DDE and o,p'-DDE acquired by the SPME samplers at a highly contaminated site on the Palos Verdes Shelf overlapped with the profiles obtained by the Infiltrex 100 system in 1997. The field tests not only reveal the advantages of the SPME samplers compared to the Infiltrex 100 system and other integrative passive devices but also indicate the need to improve the sensitivity of the SPME-based sampling technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eddy Y Zeng, David Tsukada, Dario W Diehl. 2004-11-01. Development of a solid-phase microextraction-based method for sampling of persistent chlorinated hydrocarbons in an urbanized coastal environment.. https://doi.org/10.1021/es049680m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Retention indices as identification tool in pyrolysis-capillary gas chromatography.

Pyrolysis-capillary gas chromatography (Py-cGC) represents important method to identify the analytes in the mixture after thermal degradation. This combines high effective analyte separation on-line coupled with thermal degradation process that depends on analyte structure. System of retention indices has been used for identification of the analytes after on-line pyrolysis and chromatographic separation. The pyrolysate composition has been studied during thermal degradation of polymethylmethacrylate (PMMA) at different pyrolysis temperatures and chromatographic column conditions. Homologues series of n-alkanes have been used for calculation of pyrolysate Kováts retention indices (I) and compared with mass spectrometric (MS) data of pyrolysate model mixture. To identify PMMA thermal degradation products the high density polyethylene (HDPE) as additive standard producing triplets of the olefin homologous series during co-pyrolysis has been used. These homologous series enable to calculate programmed temperature retention indices (ITPGC) to identify the analytes present in the pyrolysate. Calculated I values were compared with published I values databases to identify analytes yielded at different pyrolysis temperatures.

Chromatography, Gas↗

Solid surface mapping by inverse gas chromatography.

Inverse gas chromatography (IGC) at infinite dilution, is a technique for characterising solid surfaces. Current practice is the injection of n-alkane homologous series to obtain the free energy of adsorption of the CH2 group, from which the London component of the solid surface free energy, gamma(d)s, is calculated. A value around 40 mJ/m2 is obtained for poly(ethylene), and 30 mJ/m2 for a clean glass fibre, while the potential surface interactivity of a glass fibre is far greater than that of poly(ethylene). A specific component of the surface, in mJ/m2, should be calculated in order to obtain significant parameters. As applied up to date, when calculating the specific component of the surface energy, the fact that W(sp)a energy values are in a totally different scale than AN or DN values is a major drawback. Consequently, Ka and Kb values obtained are in arbitrary energy units, different from those of the London component measured by injecting the n-alkane series. This paper proposes a method to obtain Ka and Kb values of the surface in the same energetic scale than the London component. The method enables us to correct the traditional London component of a solid, obtaining a new value, where the amount of WaCH2 accounting for Debye interactions with polar sites, is excluded. As a result, an approach to surface mapping is performed in several different substrate materials. We show results obtained on different solid surfaces: poly(ethylene), clean glass fibre, glass beads, chemically modified glass beads and carbon fibre.

Chromatography, Gas↗

Twin comprehensive two-dimensional gas chromatographic system: concept and applications.

A twin GC x GC system has been designed which enables the analysis of a sample by means of two different and independent column combinations simultaneously. Both combinations are incorporated in the same oven, using the same temperature programme, and are fed using a 50:50 column-entrance-split. It is demonstrated that, employing combinations of a conventional non-polar x polar and a reversed-type polar x non-polar column set, the information content is as high, and the analytical performance is as good as when using two separate GC x GC systems. That is, there is an appreciable gain of time and a reduction of costs without any loss of quality. The general usefulness of performing, and comparing two mutually different GC x GC runs is further illustrated with FAMEs in olive oil, and pollutants in a sediment sample.

Chromatography, Gas↗