PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Electrochemical study of a new methylene blue/silicon oxide nanocomposition mediator and its application for stable biosensor of hydrogen peroxide.

A novel organic-inorganic nanocomposite of methylene blue (MB) and silicon oxide was synthesized and characterized by TEM, FTIR, and UV-vis. The as-prepared material was able to transfer the electron of the MB to electrode and was different from other SiO2 spheres structurally. It can be used as mediator to construct a biosensor with horseradish peroxidase (HRP) coimmobilized in the gelatine matrix and cross-linked with formaldehyde. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen peroxide (H2O2). The linear range for H2O2 determination was from 1 x 10(-5) to 1.2 x 10(-3) M, with a detection limit of 4 x 10(-6) M based on S/N = 3. Moreover, the lifetime is more than 3 months under dry conditions at 4 degrees C.

Biosensing Techniques↗

Using silver nanoparticle to enhance current response of biosensor.

In this paper, we present a simple procedure to increase the sensitivity of a glucose biosensor. The feasibility of an amperometric glucose biosensor based on immobilization of glucose oxidase (GOx) in silver (Ag) sol was investigated for the first time. GOx was simply mixed with Ag nanoparticles and cross-linked with a polyvinyl butyral (PVB) medium by glutaraldehyde. Then a platinum electrode was coated with the mixed solution. The effects of the amount of the Ag particles used, with respect to the current response for enzyme electrodes, were studied. A set of experimental results indicate that the current response for the enzyme electrode containing hydrophobic Ag sol increased from 0.531 to 31.17 microA in the solution of 10 mmol/L beta-D glucose. The time reaching the steady-state current response reduced from 60 to 20s, three times less than those without Ag particles involved.

Biosensing Techniques↗

Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood.

A carbon nanotube modified biosensor for monitoring total cholesterol in blood was studied. This sensor consists of a carbon working electrode and a reference electrode screen-printed on a polycarbonate substrate. Cholesterol esterase, cholesterol oxidase, peroxidase and potassium ferrocyanide were immobilized on the screen-printed carbon electrodes. Multi-walled carbon nanotubes (MWCN) were added to prompt electron transfer. Experimental results show that the carbon nanotube modified biosensor offers a reliable calibration profile and stable electrochemical properties.

Biosensing Techniques↗

Chemiluminescence biosensor system for lactic acid using natural animal tissue as recognition element.

A new method based on natural animal tissue porcine kidney as recognition element for chemiluminescence sensing of lactic acid is proposed in this paper. The principle for lactic acid sensing is that lactic acid is oxidized by oxygen under the catalysis of alpha-hydroxy acid oxidase in the tissue column to produce hydrogen peroxide, which can react with luminol in the presence of potassium ferricyanide to generate a CL signal. The experimental results show that the CL emission intensity was linear with lactic acid concentration in the range of 1-1000 micromol/L and the detection limit (3sigma) for lactic acid was 0.2 micromol/L. The biosensor could be used continuously for 6h with no significant changes in the response. More than 240 measurements were carried out during this time. A complete analysis, including sampling and washing, could be performed in 1.5 min with a relative standard deviation of 1.12% for 100 micromol/L lactic acid. The reproducibility among tissue columns was satisfactory (RSD among columns is less than 5%). The biosensor has been applied successfully to the analysis of lactic acid in plasma and milk samples.

Animals↗

Electrogenerated chemiluminescence biosensor with alcohol dehydrogenase and tris(2,2'-bipyridyl)ruthenium (II) immobilized in sol-gel hybrid material.

An ethanol biosensor based on electrogenerated chemiluminescence detection was developed. Electrogenerated chemiluminescence reagent tris(2,2'-bipyridyl)ruthenium (II) and alcohol dehydrogenase were immobilized in the same sol-gel hybrid film. The copolymer poly(vinyl alcohol) with 4-vinylpyridine and cation exchanger Nafion were incorporated into sol-gel film to provide the microenvironment for retaining the activity of enzyme and immobilize tris(2,2'-bipyridyl)ruthenium (II). The design was simpler than the previous two-layer format. The experimental conditions, such as scan rate, pH and concentration of the cofactor were investigated. The intensity of electrogenerated chemiluminescence increased linearly with ethanol concentration from 2.5x10(-5) to 5.0x10(-2) M and detection limit was 1.0x10(-5) M. The prepared biosensor exhibited high sensitivity, wide linear range and good stability.

2,2'-Dipyridyl↗

A novel optical biosensor format for the detection of clinically relevant TP53 mutations.

The TP53 gene has been the subject of intense research since the realisation that inactivation of this gene is common to most cancer types. Numerous publications have linked TP53 mutations in general or at specific locations to patient prognosis and therapy response. The findings of many studies using general approaches such as immunohistochemistry or sequencing are contradictory. However, the detection of specific mutations, especially those occurring in the structurally important L2 and L3 zinc binding domains, which are the most common sites of TP53 mutations, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. In this study, the TI-SPR-1 surface plasmon resonance system and Texas Instruments Spreeta chips were used to develop a DNA biosensor based on thiolated probes complementary to these domains. The sensors were able to detect these mutations in both oligonucleotides and PCR products with normal and mutant TP53 DNA, but the difference in hybridisation signal was small. Preliminary experiments to enhance the signal using Escherichia coli mismatch repair proteins, MutS and single strand binding protein were carried out. It was found that MutS was unable to bind to mismatch oligonucleotides, but single strand binding protein was able to bind to single stranded probes, which had not hybridised to the target, resulting in a three-fold increase in the sensitivity of the biosensor. While further work needs to be carried out to optimise the system, these preliminary experiments indicate that the TI-SPR-1 can be used for the detection of clinically relevant mutations in the TP53 gene and that the sensitivity can be increased significantly using single strand binding protein. This system has a number of advantages over current mutation detection technologies, including lower cost, ease of sensor preparation and measurement procedures, technical simplicity and increased speed due to the lack of need for gel electrophoresis.

Biosensing Techniques↗

A cell array biosensor for environmental toxicity analysis.

In this study, a cell-based array technology that uses recombinant bioluminescent bacteria to detect and classify environmental toxicity has been implemented to develop two biosensor arrays, i.e., a chip and a plate array. Twenty recombinant bioluminescent bacteria, having different promoters fused with the bacterial lux genes, were immobilized within LB-agar. About 2 microl of the cell-agar mixture was deposited into the wells of either a cell chip or a 384-well plate. The bioluminescence (BL) from the cell arrays was measured with the use of highly sensitive cooled CCD camera that measured the bioluminescent signal from the immobilized cells and then quantified the pixel density using image analysis software. The responses from the cell arrays were characterized using three chemicals that cause either superoxide damage (paraquat), DNA damage (mitomycin C) or protein/membrane damage (salicylic acid). The responses were found to be dependent upon the promoter fused upstream of the lux operon within each strain. Therefore, a sample's toxicity can be analyzed and classified through the changes in the BL expression from each well. Moreover, a time of only 2 h was needed for analysis, making either of these arrays a fast, portable and economical high-throughput biosensor system for detecting environmental toxicities.

Arabidopsis Proteins↗

Rapid PCR confirmation of E. coli O157:H7 after evanescent wave fiber optic biosensor detection.

Escherichia coli O157:H7 is an enteric pathogen of public health importance, which is monitored by several government agencies. Many rapid detection tests have been developed to identify foodstuff and water supplies contaminated by E. coli O157:H7. However, these methods can be time consuming (24-48 h) due to the need to culture the bacteria to confirm detection results. Fiber optic biosensors can rapidly detect pathogens from complex matrices, yet confirmation tests can take up to 10h to complete. In addition, fiber optic biosensors can also be used to reduce the impact of PCR inhibitors present in complex matrices such as food and water. This paper presents methodologies to reduce the time necessary for confirmation from 10 to about 2 h, by direct PCR of bacteria from the fiber optic waveguides without the need for culture or enrichment steps.

Antibodies, Bacterial↗

Electron transfer mediator micro-biosensor fabrication by organic plasma process.

We propose a new strategy for constructing a mediator-type biosensor as a Bio-MicroElectroMechanical Systems (BioMEMS) application. A vinylferrocene plasma-polymerized film (PPF) was deposited directly onto the surface of an electrode under dry conditions. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly crosslinked network structure. This technique, capable of polymeric deposition of any kind of monomer, can also serve the purpose of anti-fouling coating, or layer-to-layer interface creation. With a subsequent plasma process, additional polymeric layer of hydrophilic acetonitrile was superimposed onto the existing vinylferrocene-PPF surface to offer crucial features such that the wettability could be adjusted for a better electron transfer, and amino functional groups could be attached to immobilize a large amount of enzyme. Based upon this scheme, the device fabrication could be designed in a manner that the whole procedure was made up of dry wafer-handling processes, which is compatible with mass production. A prototype device was fabricated to have an array of needle-shaped amperometric micro-biosensors. The resultant thin polymer layer carried a large number of the mediator molecules, accomplishing a lower overpotential (+410 mV) and a rapid response time (<5s). Stressing the advantages of the plasma polymerization process together with some additional features accomplished in our device fabrication, we would discuss new possibilities in the field of BioMEMS.

Biosensing Techniques↗

The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix.

The glucose oxidase (GOD) is entrapped in the composite of carbon nanotubes/chitosan and direct electron transfer reaction between GOD and electrode takes place. The electron transfer rate of GOD is greatly enhanced to 7.73 s(-1) in the system, which is more than one-fold higher than that of flavin adenine dinucleotide adsorbed on the carbon nanotubes (3.1 s(-1)). This maybe results from the conformational change of GOD in the microenvironment enabling the accessibility of active site for GOD to the electrode. Additionally, the bioactivity of GOD modified in the composite on electrode surface is kept. So as-prepared electrode can be used as a glucose biosensor exhibiting higher sensitivity (0.5 microA mM(-1)) and better stability. The facile procedure of immobilizing GOD will promote the developments of electrochemical research for protein, biosensors and other bioelectrochemical devices.

Adsorption↗

Nanoparticle-based DNA biosensor for visual detection of genetically modified organisms.

Although screening of raw ingredients and food products for genetically modified organisms (GMO) may be accomplished by detecting either the exogenous DNA or the novel protein, DNA is the preferred analyte because of its superior stability during food processing. The development of DNA biosensors is of increasing importance due to the growing demand for rapid and reliable methods for GMO detection. We report the first DNA biosensor in a dry-reagent dipstick configuration for visual detection and confirmation of GMO-related sequences by hybridization within minutes. The sensor is disposable and does not require special instrumentation. It detects the 35S promoter and nopaline synthase (NOS) terminator sequences that are present in the majority of transgenic plants. The target sequences are amplified by the polymerase chain reaction (PCR) and hybridized (7min) with probes bearing oligo(dA) tail. The biotinylated product is applied to the sensor followed by immersion in the appropriate buffer. Migration of the buffer rehydrates gold nanoparticles conjugated to oligo(dT), which hybridize with the oligo(dA) tails. The hybrids are captured by immobilized streptavidin at the test zone of the sensor giving a characteristic red line due to the accumulation of the nanoparticles. The excess of nanoparticle conjugates are captured at the control zone by immobilized oligo(dA) strands. Amplified 35S or NOS DNA is detectable at 0.16nM. Soybean powder certified reference material with 0.1% GMO content is clearly detectable after 35 and 40 amplification cycles for 35S and NOS sequence, respectively. The sensor was also applied to real samples from various sources.

Biosensing Techniques↗

Development of a novel, multi-analyte biosensor system for assaying cell division: identification of cell proliferation/death precursor events.

A novel, miniaturized biosensor system was created by combining the electrophysiological response of immobilized cells with superoxide-sensing technology, optical and fluorescence microscopy. Vero cells were immobilized in a calcium alginate matrix (at a density of 1.7 x 10(6) cells ml(-1)). A 0.5 cm x 0.5 cm piece of cell-containing gel matrix was aseptically adhered on a glass microscope slide with a microfabricated gold electrode array, sealed with a cover slip and provided with Dulbecco's medium +10% (v/v) fetal calf serum every day by means of a capillary feeding tube. During a culture period of 7 days, the membrane potential of immobilized cells was continuously monitored, while cell division was assayed with an optical microscope. In addition, daily measurements of immobilized cell membrane potential, viability, RNA and calcium concentration, radical oxygen species (ROS) and glutathione accumulation, were conducted by fluorescence microscopy after provision of an appropriate dye. Superoxide accumulation was assayed by covering the electrodes with superoxide dismutase (SOD). Maximum cell membrane potential values and superoxide production were observed upon initiation of cell division. Using the novel biosensor, we were able to correlate seven different cell physiological parameters to each other and formulate a model for ROS-mediated signaling function on cell division and death. In addition, we were able to predict cell proliferation or death by comparing the relative response of the electrophysiological and superoxide sensor during the culture period.

Animals↗

Fiber-optic biosensor to assess circulating phagocyte activity by chemiluminescence.

We describe herein the construction of a novel computerized multi-sample temperature-controlled luminometer for a fiber array-based biosensor to monitor circulating phagocyte activity. It can perform simultaneously integral measurements of chemiluminescence emitted from up to six samples containing less than 0.5 microl whole blood while the samples and detector do not change their position during the measurement cycle. The optical fibers in this luminometer are used as both light guides and solid phase sample holders. The latter feature of the instrument design simplifies the assessment process of both the extra-cellular and the intra-cellular parts of the phagocyte-emitted chemiluminescence using the same system. We describe some examples or proof of principle for the use of the biosensor. This new technology may find use in a wide range of analytical luminescence applications in biology, biophysics, biochemistry, toxicology and clinical medicine.

Biosensing Techniques↗

Protection of mammalian cell used in biosensors by coating with a polyelectrolyte shell.

In order to detect xenoestrogens which induce perturbations of mammalian cells, design of biosensor using a mammalian cell line enable to detect these compounds is necessary. MELN cell line is suitable to detect estrogen activity, since they are stably transfect with an estrogen regulated luciferase gene. To realize this biosensor, it appeared necessary to add a protection to the mamalian cell, which is devoided, of the wall protecting yeasts or plant cells. With this aim in view, MELN cells have been isolated with a polyelectrolyte shell using the layer-by-layer technique. Among several polyelectrolyte-couples, the best cell survival (>80%) was obtained by alternating the polycation poly-diallyldimethyl ammonium chloride layer and the negatively charged poly-styrene sulfonate. We observed that the composition of the buffer used for layer-deposition was crucial to preserving cell viability, e.g. potassium ions were preferred to sodium ions during the coating. Furthermore, viability was increased when cells were allowed to recover for 2 h between each bilayer deposition. The use of engineered mammalian cells that synthesize luciferase as a response to exposure to estradiol, demonstrated that coating not only permits cell survival, but also allows essential metabolic functions, such as RNA and protein synthesis to take place. Capsule formation allows free diffusion of small molecules, while it prevents internalization in the cells of proteins larger than 60 kDa.

Ammonium Chloride↗

Enzyme inhibition-based biosensors for food safety and environmental monitoring.

Analytical technology based on sensors is an extremely broad field which impacts on many major industrial sectors such as the pharmaceutical, healthcare, food, and agriculture industries as well as environmental monitoring. This review will highlight the research carried out during the last 5 years on biosensors that are based on enzyme inhibition for determination of pollutants and toxic compounds in a wide range of samples. Here the different enzymes implicated in the inhibition, different transducers forming the sensing devices, and the different contaminants analyzed are considered. The general application of the various biosensors developed, with emphasis on food and environmental applications, is reviewed as well as the general approaches that have been used for enzyme immobilization, the enzyme catalysis, and the inhibition mechanism.

Biosensing Techniques↗

Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor.

Several neural diseases appear related to the neurotransmitter acethylcholine (ACh) and its metabolite choline (Ch) brain levels so that their simultaneous determination is essential. A cross-talk and interference free dual electrode amperometric biosensor for the simultaneous determination of both analytes has been developed. Acetylcholinesterase (AChE) and choline oxidase (ChO) were immobilized by glutaraldehyde co-crosslinking with bovine serum albumin. A very efficient rejection of electroactive interferents has been achieved by a novel electrosynthesized polymeric bilayer membrane composed by overoxidised poly(pyrrole) and poly(2-naphthol) films. Sensitivities towards several electroactive interferents ranged from ca. 0.04% (e.g. ascorbate) to ca. 0.3% (e.g. dopamine) of those relevant to ACh and Ch (11 and 15 microA/microM, respectively). Detection limits (at S/N=3) in flow injection analysis were ca. 100 nM for both ACh and Ch at the ChO-AChE electrode and ca. 40 nM for Ch at the ChO sensor. Biosensor performances appear more than adequate for brain tissue homogenates and cerebrospinal fluids analysis where average levels in the low micromolar range are typically found.

Acetylcholine↗

A biosensor based on co-immobilized L-glutamate oxidase and L-glutamate dehydrogenase for analysis of monosodium glutamate in food.

A monosodium glutamate (MSG) biosensor made by co-immobilized L-glutamate oxidase (L-GLOD) and L-glutamate dehydrogenase (L-GLDH) as the bio-component based on substrate recycling for highly sensitive MSG or L-glutamate determination, has been developed. Regeneration of MSG by substrate recycling provided an amplification of the sensor response. Higher signal amplification was found in the presence of ammonium ion. The sensor was standardized to determine MSG in the range of 0.02-3.0 mg/L. Linearity was obtained from 0.02 to 1.2 mg/L in presence of ammonium ion (10 mM) and NADPH (reduced nicotinamide adenine dinucleotide phosphate) (2 mM), but in absence of L-GLDH, the detection limit of MSG is confined to 0.1 mg/L. The apparent Km for MSG with L-GLOD-L-GLDH coupled reaction was 0.4451 mM but 1.9222 mM when only L-GLOD was immobilized. Cross linking with glutaraldehyde in the presence of bovine serum albumin (BSA) as a spacer molecule has been used for the method of immobilization. The response time of the sensor was 2 min. The optimum pH and temperature of the biosensor has been determined as 7+/-2 and 25+/-2 degrees C, respectively. The enzyme immobilized on the membrane was used for over 50 measurements. The standard error of the sample measurement was 4-5%. The activity of the enzyme-immobilized membrane was tested over a period of 60 days.

Amino Acid Oxidoreductases↗

Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp. whole cells adsorbed on glass fiber filters as disposable biocomponent.

An optical microbial biosensor was described for the detection of methyl parathion pesticide. Whole cells of Flavobacterium sp. were immobilized by trapping in glass fiber filter and were used as biocomponent along with optic fiber system. Flavobacterium sp. has the organophosphorus hydrolase enzyme, which hydrolyzes the methyl parathion into detectable product p-nitrophenol. The immobilized microbial biocomponent was disposable, cost-effective and showed high reproducibility and uniformity. The detection of methyl parathion by the use of disposable microbial biocomponent with optical biosensor was simple, single step and direct measurement of very low quantity of the sample. The home made reaction vessel was small and needed only 75 microl of sample. A lower detection limit 0.3 microM methyl parathion was estimated from the linear range (4-80 microM) of calibration plot of organophosphorus hydrolase enzymatic assay. The applicability to synthetic methyl parathion spiked samples was demonstrated.

Aryldialkylphosphatase↗