PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Quantitative determination of formaldehyde in cosmetics using combined headspace-solid-phase microextraction-gas chromatography.

The objective of this research was the application of headspace (HS)-solid-phase microextraction (SPME) for the quantitation of formaldehyde present in raw materials and cosmetic formulations. The formaldehyde was derivatized in situ first with pentafluorophenylhydrazine (PFPH), to form a derivative hydrazone. The formed hydrozone was adsorbed on a SPME fiber during headspace extraction under controlled conditions (time, temperature, volume, etc.). After the adsorption step, the SPME fiber was directly transferred into the gas chromatography (GC) injection port in which the analytes were thermally desorbed. Deuterated acetone was used as an internal standard (IS) in order to quantitate the formaldehyde content. For the experiment, a gas chromatograph equipped with a flame ionization detector (GC/FID) was employed. A gas chromatograph/mass spectrometer (GC/MS) was used for the qualitative confirmation of results in this work.

Chromatography, Gas↗

Solid phase microextraction-gas chromatography for quantifying headspace hexanal above freeze-dried chicken myofibrils.

A method using solid phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) was developed and used to determine the oxidation of freeze-dried chicken myofibrils spiked with methyl linoleate. Freeze-dried chicken myofibrils were found to act as a significant reservoir for hexanal. Recovery of hexanal emissions from the headspace above spiked myofibrils was 95% using a 5 min sampling time, with a total analysis time of approximately 12 min/sample. The SPME-GC/MS working linear response was from 0.01 to 10 mg hexanal/L (r( 2) = 0.995). Freeze-dried chicken myofibrils with added methyl linoleate (0.6 mmol/g of protein) were stored at 50 degrees C at water activities of 0.30 and 0.75 for 0, 12, 27, and 50 h. Lipid oxidation was determined using SPME-GC/MS to measure headspace hexanal concentration, the thiobarbituric acid reactive substances assay (TBARS) to quantify malonaldehyde, and a conjugated diene assay. Lipid oxidation was influenced by storage time and water activity. A strong correlation (r = 0.938) existed between SPME-GC/MS and TBARS. The use of SPME-GC/MS was a sensitive and rapid method for detecting hexanal as an indicator of lipid oxidation in chicken myofibrils.

Aldehydes↗

Development and application of polymer-coated hollow fiber membrane microextraction to the determination of organochlorine pesticides in water.

A novel extraction procedure coupled with gas chromatography-mass spectrometric detection for quantification of organochlorine pesticides (OCPs) in water is described. Amphiphilic polyhydroxylated polyparaphenylene (PH-PPP) was synthesized and coated on the surfaces of a porous polypropylene hollow fiber membrane (HFM). Due to the high porosity of the HFM, maximum active surface area to achieve high extraction efficiency is expected. The polymer-coated HFM was used for the extraction of 15 OCPs from water. The extraction efficiency was compared with emerging and established methods such as liquid-phase microextraction (LPME), solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) techniques. We term the current procedure as polymer-coated hollow fiber microextraction (PC-HFME). PC-HFME showed good selectivity and sensitivity. Detection limits for OCPs were in the range of 0.001-0.008 microg l(-1). The sensitivity and selectivity of the coated HFM could be adjusted by changing the characteristics of the coated PH-PPP film.

Hydrocarbons, Chlorinated↗

Headspace-solid phase microextraction-gas chromatography as a tool to define an index that establishes the retention capacity of the wine polymeric fraction towards ethyl esters.

A headspace-solid phase microextraction followed by gas chromatographic analysis (HS-SPME-GC) was developed to be applied in the study of the interactions between the wine polymeric fraction and the ethyl esters: ethyl hexanoate, ethyl octanoate, and ethyl decanoate. Wine models (WM) were prepared with 10% (v/v) aqueous ethanol at pH 3.5 with distinct wine polymeric concentrations prepared from white wine of Vitis vinifera L. var. Fernão-Pires: 1.0 g L(-1) (PWM1), with a polymeric concentration approaching the real one in wine; 10.0 g L(-1) (PWM10); and 30.0 g L(-1) (PWM30), saturated with polymeric fraction. A reference wine model (RWM) was prepared without polymeric fraction. Each volatile compound (4.0 mg L(-1)) was added separately to the RWM and to the WM with the three levels of polymeric material (PWM). From the retention index (RI) calculated for each compound using the formula: [RI = 1 - (C(RWM) - C(PWM))/C(RWM)], where C(RWM) is the concentration of the compound in the RWM and C(PWM) is the concentration of the compound in the given PWM, the retention capacity of each wine polymeric fraction towards the three esters was established. The higher retention indexes were observed for ethyl decanoate, the more hydrophobic compound, and for the PWM with higher concentration. Furthermore, this study also suggested that the retained compounds are dosed to the headspace, which may promote the perception of their aroma for a longer period of time.

Adsorption↗

Solid-phase microextraction-liquid chromatography (SPME-LC) determination of fluoxetine and norfluoxetine in plasma using a heated liquid flow through interface.

A simple and sensitive procedure using solid-phase microextraction coupled with high performance liquid chromatography (HPLC) to analyze fluoxetine (FLU) and its metabolite norfluoxetine (nor-FLU) in plasma samples was developed and validated. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Fluoxetine and norfluoxetine were analyzed by HPLC, using a C18 Phase Sep column (150mmx4.6mm, 3microm) packed "in house", and acetonitrile:acetate buffer 25mmoll(-1) with triethylamine 25mmoll(-1) pH 4.6 (70:30) as the mobile phase. The developed method has shown precision, linearity, specificity, and limit of quantification (LOQ) adequate to assay fluoxetine and norfluoxetine in plasma. Furthermore, the results obtained using the homemade interface has shown an improvement in the desorption process when compared with the results obtained using the off-line mode.

Chromatography, High Pressure Liquid↗

Identification of odor signature chemicals in cocaine using solid-phase microextraction-gas chromatography and detector-dog response to isolated compounds spiked on U.S. paper currency.

Solid-phase microextraction (SPME) combined with gas chromatography (GC) is optimized and applied to the analysis of street-cocaine samples followed by the field-testing of isolated chemicals using certified detector dogs. SPME proves to be a very sensitive and rapid method for isolating odor chemicals from street-cocaine samples. SPME-GC and activated charcoal strip (ACS)-SPME-GC signature profile methods are developed for the detection and quantitation of cocaine-odor chemicals, including the optimization of controllable variables such as fiber chemistry, extraction time, and desorption time. The volatile odor chemicals in representative illicit cocaine samples are identified and quantitated by the ACS-SPME-GC signature profile method and direct injection. Field tests with drug detector dogs show methyl benzoate to be the dominant signature odor chemical along with cocaine on U.S. currency at a threshold level of approximately 1-10 microg when spiked or when 10 ng/s methyl benzoate is diffused from polymer bottles, which is required in order to initiate an alert. No other substance studied initiated consistent responses by the drug dogs. The results indicate that the microgram levels of cocaine that have been reported on circulated U.S. currency are insufficient to signal an alert from law-enforcement trained drug detector dogs.

Animals↗

Multiresidue method for the simultaneous determination of four groups of pesticides in ground and drinking waters, using solid-phase microextraction-gas chromatography with electron-capture and thermionic specific detection.

A common sample preparation procedure capable of efficiently concentrating various groups of pesticides, taking advantage of universal detectors like the mass spectrometer or combined techniques of group selective detectors like gas chromatography-electron capture detection (ECD)/thermionic specific detection (TSD), is desirable in environmental analysis. Six solid-phase microextraction fibres available for analysis of semi-volatiles (7, 30 and 100 microm poly(dimethylsiloxane) (PDMS), 85 microm polyacrylate, 60 microm PDMS-divinylbenzene (PDMS-DVB) and 65 microm Carbowax-DVB) were evaluated and the 60 microm PDMS-DVB was selected for the simultaneous extraction of 34 compounds, included in the organochlorine (OCPs), organophosphorous (OPPs), pyrethroid and triazine pesticide groups. All parameters affecting the extraction efficiency from water samples, namely fibre coating, sample agitation, pH and ionic strength, extraction temperature and time, were optimised. The analytical procedure involves solid-phase microextraction extraction, gas chromatographic separation and subsequent ECD and TSD via a post-column splitter adjusted to a split ratio of 1:10, respectively. Detection limits in the range of 1-10 ng l(-1) for OCPs, 1-30 ng l(-1) for OPPs, 20-30 ng l(-1) for pyrethroids and 8-50 ng l(-1) for triazines are easily attainable with the optimised procedure. The method validated for ground and drinking waters has low cost of implementation and operation although it requires careful maintenance.

Chromatography, Gas↗

Simple analysis of diphenylmethane antihistaminics and their analogues in bodily fluids by headspace solid-phase microextraction-capillary gas chromatography.

Thirteen antihistaminic drugs and their analogues are tested for their extraction by headspace solid-phase microextraction from human whole blood and urine. Their determination is made by using capillary gas chromatography with flame ionization detection. Relatively high recoveries are obtained for terodiline, diphenhydramine, diphenylpyraline, and orphenadrine in urine; but the recoveries in blood extracts are 4-51 times lower than those in urine extracts for all drugs. Benactyzine and piperilate are not suited for the extraction method. The calibration curves are drawn for four drugs spiked to whole blood and for eleven drugs spiked to urine; excellent linearity is confirmed for the drugs. The detection limits for the drugs are 76-473 ng/mL in blood and 13-186 ng/mL in urine. Diphenhydramine is determined for whole blood obtained from a male subject who had received oral administration of 30 mg diphenhydramine-HCl 150 min before the sampling; the concentrations of the drug are 0.12 and 1.22 micrograms/mL for blood and urine, respectively.

Adult↗

Development of a solid phase microextraction-gas chromatography method to determine N-hydroxymethyl-N-methylformamide and N-methylformamide in urine.

A headspace solid phase microextraction (SPME) method has been developed to determine metabolites of dimethylformamide, N-hydroxymethyl-N-methylformamide, and N-methylformamide (NMF) as NMF in urine by gas chromatography with nitrogen-phosphorus detector (GC-NPD). An SPME holder with a 65-microm PDMS/DVB fiber coating was used. Optimal desorption conditions were 250 degrees C for 1 min, adsorption at 80 degrees C for 15 min, and 3.00 mL of sample in the headspace vial. The method presented good resolution, repeatability, recovery, detection limit, ruggedness and response linearity.

Chromatography, Gas↗

MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples.

Solid-phase microextraction coupled to GC-MS was optimised for the determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters and polychlorinated biphenyls (PCBs) in water samples. A 30-microm polydimethylsiloxane fiber was immersed in a 30-ml water sample that contained the analytes of interest (PAHs, PCBs and phthalate esters) and the variables studied were extraction time (15-60 min), extraction temperature (30-90 degrees C), desorption time (1-5 min), desorption temperature (220-270 degrees C) and the addition of sodium chloride (0-9 g). The MultiSimplex programme based on the simplex algorithm was used to establish the optimal conditions. MultiSimplex allowed the simultaneous study of the variables mentioned above and considered the answers of all types of compounds studied in this work. Thus, the optimal conditions obtained allowed the simultaneous determination of PAHs, phthalate esters and PCBs. Furthermore, the accuracy and repeatability of the developed method were calculated from water samples spiked at known concentrations of the analytes. Finally, the optimised method was used to analyse water samples from different sampling points of the Urdaibai and Nerbioi-Ibaizabal estuaries (Biscay, Spain).

Gas Chromatography-Mass Spectrometry↗

Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

Chromatography, Gas↗

Development of headspace solid-phase microextraction-gas chromatography method for the determination of solvent residues in edible oils and pharmaceuticals.

The application of headspace solid-phase microextraction for isolation and enrichment of solvent residues from oils and pharmaceuticals is discussed. The optimal parameters for isolation and preconcentration of common process solvents (hexane, benzene, toluene and selected chloroderivatives of hydrocarbons) were established. Four fiber types (100 microm polydimethylsiloxane (PDMS), 75 microm Carboxen-PDMS, 65 microm PDMS-divinylbenzene and 85 microm polyacrylate) were evaluated to choose the most efficient coating, able to absorb the greatest amount of analytes. GC-flame ionization detection (FID) and GC-electron-capture detection systems were used for quantitative and qualitative analysis, adequately to the appropriate group of the analytes. For all compounds the limit of detection (LOD), linearity, dynamic range, repeatability and intermediate precision were estimated.

Chromatography, Gas↗

Solid-phase microextraction-gas chromatographic-mass spectrometric analysis of volatile compounds from Curcuma wenyujin Y.H. Chen et C. Ling.

A solid-phase microextraction coupled with gas chromatography-mass spectrometry (SPME-GC-MS) for analysis of the volatile compounds from Curcuma wenyujin Y.H. Chen et C. Ling is described. SPME parameters (fiber type, extraction temperature and time, headspace volume and desorption time) and GC conditions were tested. The powdered sample of C. wenyujin Y.H. Chen et C. Ling was directly analyzed by SPME-GC-MS and 72 compounds were identified. The results from SPME-GC-MS were compared with those obtained from steam distillation gas chromatography-mass spectrometry (SD-GC-MS) with a good agreement. The results show that SPME-GC-MS method is a fast, simple and efficient way for the analysis of volatile components from traditional Chinese medicines (TCMs).

Curcuma↗

Solid-phase microextraction-capillary gas chromatography combined with microwave-induced plasma atomic-emission spectrometry for selenite determination.

The use of solid-phase microextraction (SPME) with gas chromatography coupled to microwave-induced plasma atomic-emission detection (GC-MIP-AED) is described for selenite [Se(IV)] speciation. Aqueous standards were derivatised with sodium tetraethyl- or tetrapropylborate and extracted by SPME. Headspace extraction of the ethyl and propyl derivatives was studied. Relevant experimental conditions were optimised, including conditions for derivatisation and extraction and those of gas chromatographic analysis. The limits of detection achieved for headspace sampling of derivatised Se(IV) were in the low ng mL(-1) range for both ethylation and propylation. When the method was applied to analysis of selenite in selenised yeast reference material results were in good agreement with the indicated values.

Journal Article↗

Solid-phase microextraction-gas chromatographic-mass spectrometric method for the determination of the fungicides cyprodinil and fludioxonil in white wines.

A solid-phase microextraction (SPME) followed by a gas chromatographic-mass spectrometric (GC-MS) determination has been developed and validated for the determination of cyprodinil and fludioxonil in white wine samples. Extraction parameters such as the selection of SPME coating, the effect of the temperature, the effect of the headspace volume and the salt addition were studied and optimized, together with GC-MS analytical conditions. The divinylbenzene-Carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fiber was the most appropriate for the determination of the two pesticides in wine. The quality parameters of the proposed method demonstrated a good precision (RSD about 5%), with detection limits of 0.1 and 0.2 microg/l for cyprodinil and fludioxonil, respectively. Fifteen commercial white wine samples produced in Rías Baixas area in Galicia (N.W. Spain) were analyzed with the SPME-GC-MS procedure. Some of the commercial wines (75%) presented the two pesticides in concentrations ranging from 0.9 to 28.6 microg/l. In conclusion, SPME-GC-MS has a great potential for fungicide determination in wines.

Dioxoles↗

Determination of 4-ethylguaiacol and 4-ethylphenol in red wines using headspace-solid-phase microextraction-gas chromatography.

A method for analysing 4-ethylguaiacol and 4-ethylphenol in the aroma of red wines using headspace-solid-phase microextraction is presented. The fibres used were coated with 100 microm of polydimethylsiloxane. Parameters like ionic strength, agitation of the sample, sample volume, temperature of the sample and adsorption/desorption times were studied and optimised to obtain the best extraction results. The linearity of the response was studied in the usual concentration ranges in wines (4-ethylguaiacol, 40-400 microg/l; 4-ethylphenol, 200-1800 microg/l). Repeatability of the method was determined, and the relative standard deviation was about 10%. Limits of detection and limits of quantification were also determined, and the values found were 1 and 5 microg/l for 4-ethylguaiacol and 2 and 5 microg/l for 4-ethylphenol, respectively. All these values were under the sensory thresholds established for these volatile phenols. The presence of interferences due to the matrix composition implies the use of the standard addition technique for both compounds quantification.

Chromatography, Gas↗

Determination of butyltin species in water and sediment by solid-phase microextraction-gas chromatography-flame ionization detection.

A procedure for determination of tetraethyltin (TeET) and tetrabutyltin (TeBT) in water by solid-phase microextraction (SPME) using the headspace approach has been developed. The method has been adapted for the simultaneous determination of mono-, di- and tributyltin species (MBT, DBT and TBT) after derivatization with sodium tetraethylborate in water and sediment samples. The analytical procedures were optimized with respect to stirring conditions, extraction time and extraction temperature. The pH and the amount of derivatizing reagent were also considered in derivatization reaction procedures. The analysis was carried out using gas chromatography equipped with flame ionization detection. The detection limits obtained for TeET and TeBT, in equilibrium conditions (room temperature for TeET and 40 degrees C for TeBT) were 28 and 20 ng/l (as Sn), respectively. The detection limit for butyltin species in water, which was limited by signals which are non-specific for the tin compounds and the sensitivity of the FID system, was found ca. 1 microg/l (as Sn). The SPME method was validated for analysis of sediments by analyzing the certified reference material PACS-2 finding a good agreement with the certified values.

Calibration↗

Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine.

The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was evaluated for the determination of ranitidine. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary column by repeated aspirate/dispense steps. In order to optimize the extraction of ranitidine, several in-tube SPME parameters such as capillary column stationary phase, extraction pH and number and volume of aspirate/dispense steps were investigated. The optimum extraction conditions for ranitidine from aqueous samples were 10 aspirate/dispense steps of 30 microliters of sample in 25 mM Tris-HCl (pH 8.5) with an Omegawax 250 capillary column (60 cm x 0.25 mm I.D., 0.25 micron film thickness). The ranitidine extracted on the capillary column was easily desorbed with methanol, and then transported to the Supelcosil LC-CN column with the mobile phase methanol-2-propanol-5 M ammonium acetate (50:50:1). The ranitidine eluted from the column was determined by ESI-MS in selected ion monitoring mode. In-tube SPME followed by LC-ESI-MS was performed automatically using the HP 1100 autosampler. Each analysis required 16 min, and carryover of ranitidine in this system was below 1%. The calibration curve of ranitidine in the range of 5-1000 ng/ml was linear with a correlation coefficient of 0.9997 (n = 24), and a detection limit at a signal-to-noise ratio of three was ca. 1.4 ng/ml. The within-day and between-day variations in ranitidine analysis were 2.5 and 6.2% (n = 5), respectively. This method was also applied for the analyses of tablet and urine samples.

Anti-Ulcer Agents↗