PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spectrophotometry, Ultraviolet”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Purification of Xenopus transcription factor IIIA and 5 S RNA from 7 S ribonucleoprotein particle by ammonium sulfate precipitation.

A simple and efficient method for purifying Xenopus transcription factor IIIA from the 7 S particle has been developed by taking advantage of the differential solubilities of the protein factor and 5 S RNA in ammonium sulfate solution. Conditions under which ammonium sulfate dissociates the 7 S particle and selectively precipitates factor IIIA while the 5 S RNA moiety remains in the supernatant were found. The method simultaneously purifies, in a nondestructive manner, both factor IIIA and 5 S RNA in high yield. Purification proceeds through several ammonium sulfate precipitations of the 7 S particle. Factor IIIA obtained by this method contains no detectable RNA and is highly active as judged by DNase I footprinting and in vitro transcription of the 5 S RNA gene, as well as reconstitution with 5 S RNA to form the 7 S particle. The molar extinction coefficients of factor IIIA at 205 and 280 nm were determined from the ultraviolet absorption spectra measured with the purified protein.

Ammonium Sulfate↗

On-line post-column fluorescence detection for N-terminal tyrosine-containing peptides in high-performance liquid chromatography.

A detection system based on on-line post-column fluorescence derivatization is described for the determination of N-terminal tyrosine-containing peptides by reversed-phase high-performance liquid chromatography. The peptides are automatically converted into fluorescent derivatives by reaction with hydroxylamine, cobalt (II) and borate after peptide separation on a reversed-phase column (TSKgel ODS-120T) followed by passage through an ultraviolet absorbance detector. The reaction system permits the fluorescence detection at 435 nm (emission) with excitation at 335 nm for N-terminal tyrosine-containing synthetic peptides in as little as picomole amounts. The facile fluorescence detection of N-terminal tyrosine-containing fragments produced from methionine-enkephalin by enzymatic degradation using a rat brain homogenate was achieved by comparison with the ultraviolet absorption detection at 215 nm.

Animals↗

Improved high-performance liquid chromatographic assay for encainide and its metabolites in human body fluids.

Methods reported previously for the determination of encainide and its metabolites in biological fluids have not been extensively described and evaluated. We report an improved high-performance liquid chromatographic assay for the quantification of these compounds in plasma and urine with complete estimation of the accuracy and reproducibility of the analytical method. The major improvements consist of: (1) the use of ethaverine as an appropriate internal standard; (2) the use of the salting-out technique which improves the extraction recovery for the metabolites of encainide and the sensitivity of the assay; and (3) a shift of the ultraviolet absorption wavelength from 254 to 270 nm to increase the selectivity of the detection.

Anilides↗

Analysis of serum iron by gel permeation high-performance liquid chromatography.

A high-performance liquid chromatographic procedure for the determination of serum iron is reported. Serum iron extracted with methyl isobutyl ketone was converted to dibenzoylmethane chelate (molecular weight 725), and it was separated from excess dibenzoylmethane (molecular weight 224) by gel permeation chromatography. The chelate was determined by measuring ultraviolet absorption at 280 nm. Good reproducibility, recovery, and correlation with the conventional colorimetric method were observed.

Chromatography, High Pressure Liquid↗

Interfering basic materials in urine from racing greyhounds.

Three quinoline amines, 2-aminomethylquinoline, 2-hydroxymethylquinoline and quinaldine (2-methylquinoline), are identified in greyhound urine. These amines can interfere in the analysis of greyhound material for basic drugs. This is a special problem in ultraviolet spectrometry since their extinction coefficients are high. Reference analytical data for these quinoline amines and for six related compounds are given. The techniques used are infrared spectrometry, ultraviolet spectrometry, fluorometry, thin-layer chromatography, gas chromatography and mass spectrometry.

Amines↗

Determination of sodium phenobarbital in animal chow by high-pressure liquid chromatography.

An analytical procedure is described for determining residues of sodium phenobarbital in animal chow at levels as low as 0.14 ppm. The methanol extract is subjected to a liquid-liquid cleanup at pH 13 and 1, further cleaned up on a silica gel column and assayed by high-pressure liquid chromatography by using an ultraviolet absorption detector at 210 nm. Data concerning extraction efficiency, partition values and stability of the chemical in animal chow are also presented.

Animal Feed↗

Kinetic and structural properties of diacetyl reductase from hamster liver.

Kinetic and physicochemical properties of hamster liver diacetyl reductase have been examined. The results of kinetic studies on the reduction of diacetyl and NADPH to acetoin and NADP+ suggest that the reaction follows an Ordered Bi Bi mechanism in which NADPH binds first before diacetyl. The enzyme is a tetrameric glycoprotein of single subunits of a molecular weight of 23,500 with a sedimentation coefficient of 6.0S. The enzyme does not contain Zn, Cu, or Fe. The amino acid composition revealed an unusually low proportion of proline residues (0.9%). p-Chloromercuriphenylsulfonate and phenylglyoxal inactivated the enzyme, but the presence of NADPH prevented the loss of activity due to thiol and arginine modification. The enzyme transferred the pro 4S hydrogen atom of NADPH to the substrate and the binding of the enzyme to NADPH resulted in a red shift of the ultraviolet absorption spectrum of the cofactor.

Acetoin Dehydrogenase↗

[Biochemical diagnosis of Smith-Lemli-Opitz syndrome in a patient with congenital adrenal hyperplasia].

AIM: Smith-Lemli-Opitz syndrome is an autosomal recessive disorder caused by 7 dehydrocholesterol D7 reductase deficiency that leads to serum cholesterol deficiency and accumulation of the cholesterol precursor, 7 dehydrocholesterol. We report a three-month-old boy with congenital adrenal hyperplasia and clinical diagnosis of this syndrome. This study was undertaken to confirm biochemically the clinical diagnosis of Smith-Lemli-Opitz syndrome. METHODS: Serum 7 dehydrocholesterol was determined in serum by ultraviolet spectroscopy (qualitatively) using a recently described simple and rapid method, and by gas chromatography (quantitatively). RESULTS: The ultraviolet spectroscopy assay detected serum 7 dehydrocholesterol. This result was confirmed by gas chromatography. Furthermore, the patient showed very low total cholesterol. CONCLUSIONS: The association between Smith-Lemli-Opitz syndrome and congenital adrenal hyperplasia has been reported in only a few cases. Our results suggest that clinical diagnosis of Smith-Lemli-Opitz syndrome can be biochemically confirmed by qualitative measurement of 7 dehydrocholesterol using ultraviolet spectroscopy.

Adrenal Hyperplasia, Congenital↗

The measurement of acetanilide in plasma by spectrophotometric and selected ion monitoring methods.

Plasma samples from volunteers who had received an oral dose of acetanilide have been analysed by gas chromatography mass spectrometry and ultraviolet absorption techniques. The gas chromatography mass spectrometry method involved extraction of the plasma and analysis of the acetanilide using selected ion monitoring with a deuterated internal standard. In the ultraviolet method the plasma was hydrolysed with acid to convert the acetanilide to aniline, and this compound was diazotized and coupled with N-1-naphthylethylene-diamine. The absorbance of the resulting complex was read at 550 nm. Acetanilide levels in plasma determined by the selected ion monitoring method were significantly lower than those measured by spectrophotometry. Pharmacokinetic data calculated from the results obtained using these two assays are very different and illustrate the need for an accurate and specific method of analysis. The major metabolites of acetanilide are shown not to interfere with these assays and the results suggest the possible presence of a new metabolite of acetanilide.

Acetanilides↗

Determination of paracetamol (acetaminophen) in different body fluids and organ samples after solid-phase extraction using HPLC and an immunological method.

A solid-phase extraction method routinely used for serum samples was improved and applied to the qualitative and quantitative determination of paracetamol in different body fluids, e.g. blood, urine, cerebrospinal fluid, synovial fluid, vitreous humor, and in tissue samples. A very simple method showed best results: Body fluids were mixed with phenacetine as internal standard and phosphate buffer (pH 6.8). Then protein was precipitated using acetonitrile. After strong centrifugation the supematant was transferred to a preconditioned Bakerbond C18-SPE-column. Elution with methanol without a prior washing step showed best recovery rates. The extracts were investigated using high-performance liquid chromatography with ultraviolet detection, a photometrical and an immunochemical method.

Acetaminophen↗

A comment on the evaluation of equilibrium constants for alpha-tocopherol interactions with fatty acids by absorbance in the ultraviolet region.

This paper comments on the evaluation of Erin and co-workers (Biochim. Biophys. Acta 774 (1984) 96-102) of equilibrium constants for alpha-tocopherol interactions with fatty acids on the basis of the changes of absorbance in a 200 nm ultraviolet region. It is concluded that the ultraviolet method is inadequate because it is affected by absorption in that region of the solvent, ethanol and fatty acids which they used.

Chemical Phenomena↗

High-performance liquid chromatographic determination of theophylline and its derivatives with electrochemical detection.

Theophylline and its derivatives are determined by high-performance liquid chromatographic separation on a C8 reversed-phase column with electrochemical detection. The analyte is oxidized at 1.24 V (vs. the standard calomel electrode) on a wax-impregnated graphite electrode using classical d.c. and current sampled d.c. modes, and the results obtained compared with those of a 254 nm ultraviolet (UV) detector. Polarographic detection offers greater sensitivity for theophylline than UV detection; further, interferences which hamper UV detection may be selectively eliminated with polarographic detection.

Chromatography, High Pressure Liquid↗

Quality control Fourier transform infrared determination of diazepam in pharmaceuticals.

A quality control procedure has been developed for the determination of diazepam in pharmaceuticals using Fourier transform infrared (FTIR) spectroscopy. The method involves the off-line extraction of diazepam with chloroform by sonication and direct determination in the extracts through peak area measurement in the interval between 1672 and 1682 cm(-1) using a baseline correction defined between 1850 and 1524 cm(-1). For standardization it was used an external calibration line established from standard solutions of diazepam in chloroform. The method provides a limit of detection of 0.04 mg per tablet (n=5), a relative standard deviation (R.S.D.) of 0.5% for 5 independent measurements of a standard solution at a concentration level of 0.76 mg g(-1) and a sampling frequency of the whole procedure of 4 h(-1), being required only 45 s for the measurement step. Results obtained by FTIR agree with those obtained by a reference methodology based on ultraviolet spectrometry and thus the developed procedure offers a good alternative for the determination of diazepam in pharmaceuticals.

Anti-Anxiety Agents↗