PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Characterization of the leachate in an urban landfill by physicochemical analysis and solid phase microextraction-GC/MS.

The aim of this study is to evaluate extensively the characterization and identification of major pollutant parameters by paying attention to the organic chemical pollution for unregulated dumping site leachate in Eskişehir/Turkey. The study that is first and only one research has been very important data related with before new sanitary landfill site in Eskişehir city. For this purpose, in this study leachate samples were collected in-situ at monthly interval for a period of 8 months. Firstly, thirty three physicochemical parameters were monitored. Secondly, SPME technique was used for identification of organic pollutants. Meteorological data were also recorded for the same sampling period to correlate meteorological data and physicochemical parameters. Mean values are used in the correlation analysis. Correlation is shown only for the relationship between air temperature and NO(3) (-). No correlation has been found between rain and leachate quality parameters since the amount of rain was very low during the sampling period. However, analysis results were generally decreased in winter season when each parameter and each sampling point are examined separately. According to correlation between every parameter, especially solid content and dissolved oxygen concentration of leachate is affecting to other parameters. Also, sodium and potassium are changing proportionally with same parameters (suspended solids, fixed solids, dissolved oxygen) and high correlation between chloride and heavy metal concentration is showing. The results were statistically evaluated by use of SPSS 10.0 program. Second part of the study, the leachate was extracted by Solid Phase Microextraction (SPME) technique and then analyzed. Of the methodologies tested in this study, the best one selected was based on 100 micro m polydimethylsiloxane coated fiber (PDMS), headspace with heating (Delta HS) sampling mode and an extraction time of 15 min. at a temperature of 50 degrees C. Thirty three organic compounds in leachate were identified by GC/MS.

Dimethylpolysiloxanes↗

Full automation of derivatization--solid-phase microextraction-gas chromatography-mass spectrometry with a dual-arm system for the determination of organometallic compounds in aqueous samples.

The determination of organometallic compounds in aqueous samples by in-vial derivatization and headspace solid-phase microextraction (SPME)-gas chromatography (GC)-mass spectrometry (MS) has been fully automated using a Twin PAL dual-arm robotic system. Linearity, accuracy, sensitivity for a series of n-methyl, n-ethyl, and n-phenyl metal substituted chloride compounds of tin, lead, and mercury were investigated. The automated method was compared to similar manual methods and improved precision, speed and throughput was achieved. By originally programming the Twin PAL dual-arm system with the supplier's software (Cycle Composer, Version 1.5.0) the arms on the robot were only able to work in sequence. However, in order to have a flexible system and exploit time efficiently the robotic arms must work simultaneously. This was accomplished by programming the robot with the new software package called Cruise Control 4-2 for Twin PALs. Compared to Cycle Composer, Cruise Control 4-2 enhanced the speed and throughput of the automated system further. In addition, with a built-in crash prevention protocol and an improved user interface a more user-friendly system was obtained.

Automation↗

Determination of explosives in environmental water samples by solid-phase microextraction-liquid chromatography.

When explosives are present in natural aqueous media, their concentration is usually limited to trace levels. A preconcentration step able to remove matrix interferences and to enhance sensitivity is therefore necessary. In the present study, we evaluated solid-phase microextraction (SPME) technique for the recovery of nine explosives from aqueous samples using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Several parameters, including adsorption and desorption time, coating type, rate of stirring, salt addition, and pH, were optimized to obtain reproducible data with good accuracy. Carbowax coating was the only adsorbent found capable of adsorbing all explosives including nitramines. Method detection limits (MDL) were found to range from 1 to 10 microg/L, depending on the analyte. SPME/HPLC-UV coupling was then applied to the analysis of natural ocean and groundwater samples and compared to conventional solid-phase extraction (SPE/HPLC-UV). Excellent agreement was observed between both techniques, but with an analysis time around five times shorter, SPME/HPLC-UV was considered to be applicable for quantitative analysis of explosives.

Adsorption↗

Rapid study of fragrance loss from commercial soap after use by solid phase microextraction-GC/MS and olfactory evaluation.

A quick and reliable approach was reported to measure the perfume loss in a commercial soap sample after continued use. This work firstly studied the fragrance loss profile in soap scientifically combined and compared with traditional olfactory evaluation. Solid-phase microextraction (SPME), as a simple and effective adsorption and desorption technique, was selected here to eliminate the needs of organic solvents or complicated apparatus; more importantly, SPME kept the soap intact and made it available for continued study. Thanks to control of the sampling time and other extraction parameters, a consistent and reliable result was achieved, which was much better and more detailed than traditional olfactory evaluation done by human beings.

Calibration↗

Determination of gamma-hydroxybutyrate in water and human urine by solid phase microextraction-gas chromatography/quadrupole ion trap spectrometry.

A simple method of detection was developed for gamma-hydroxybutyrate (GHB). The method involves the derivatization of GHB using a hexyl-chloroformate procedure in aqueous media (such as water or urine), extraction of the derivatization product directly from the sample using solid-phase microextraction, and subsequent separation and detection with gas chromatography quadrupole ion trap mass spectrometry. The deuterated form of GHB (GHB-D6) is used as an internal standard for quantitation. The method was linear for GHB-spiked pure water samples from 2 to 150 microg/mL GHB with a detection limit of 0.2 microg/mL. Spiked urine samples showed linearity from 5 to 500 microg/mL GHB with a detection limit of 2 microg/mL. The SPME-GC/MS method is applied to actual case samples, and the results are compared to those values obtained using a conventional GC/MS method. Sensitivity and linearity are comparable to those seen using traditional methods of separation, yet the SPME method is superior due to the simplicity, speed of analysis, reduction in solvent waste, and ability to differentiate between GHB and gamma-butyrolactone (GBL).

Anesthetics, Intravenous↗

Development of a headspace solid-phase microextraction-gas chromatography-mass spectrometry method for the identification of odour-causing volatile compounds in packaging materials.

A method for the identification of volatile organic compounds in packaging materials is presented in this study. These compounds are formed by thermooxidative degradation during the extrusion coating process in the manufacture of packaging. Headspace solid-phase microextraction (HS-SPME) was used as sample preparation technique prior to the determination of the volatile organic compounds by gas chromatography-mass spectrometry (GC-MS). The effects of extraction variables, such as the type of fibre, the incubation temperature, the pre-incubation time, the size of the vial and the extraction time on the amounts of the extracted volatile compounds were studied. The optimal conditions were found to be: carboxen-polydimethylsiloxane 75 microm fibre, 5 min of pre-incubation time, 100 degrees C of incubation temperature, 20-ml vial, and 15 min of extraction time. The chromatograms obtained by HS-SPME and static headspace extraction were compared in order to show that the HS-SPME method surpasses the static headspace method in terms of sensitivity. Twenty-five compounds were identified including carbonyl compounds (such as 3-methyl-butanal, 3-heptanone or octanal), carboxylic acids (such as pentanoic acid or hexanoic acid) known as odour causing compounds and hydrocarbons (such as decane, undecane or dodecane). Finally, the method was applied to different packaging samples (one odour-unacceptable, two odour-acceptable, and three odourless samples) and to the raw materials in order to find out the odour-responsible volatile organic compounds and their source.

Food Packaging↗

Solid-phase microextraction-gas chromatography-mass spectrometry for the analysis of selective serotonin reuptake inhibitors in environmental water.

The continuous contamination of surface waters by pharmaceuticals is of most environmental concern. Selective serotonin reuptake inhibitors (SSRIs) are drugs currently prescribed for the treatment of depressions and other psychiatric disorders and then, they are among the pharmaceuticals that can occur in environmental waters. Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of five SSRIs--venlafaxine, fluvoxamine, fluoxetine, citalopram and sertraline--from water samples. Some of the analytes were not efficiently extracted as underivatized compounds and so, an in situ acetylation step was introduced in the sample preparation procedure. Different parameters affecting extraction efficiency such as extraction mode, fiber coating and temperature were studied. A mixed-level fractional factorial design was also performed to simultaneously study the influence of other five experimental factors. Finally, a method based on direct SPME at 100 degrees C using polydimethylsiloxane-divinylbenzene fibers is proposed. The performance of the method was evaluated, showing good linearity and precision. The detection limits were in the sub-ng/mL level. Practical applicability was demonstrated through the analysis of real samples. Recoveries obtained for river water and wastewater samples were satisfactory in all cases. An important aspect of the proposed method is that no matrix effects were observed. Two of the target compounds, venlafaxine and citalopram, were detected and quantified in a sewage water sample.

Gas Chromatography-Mass Spectrometry↗

Determination of homocysteine and its related compounds by solid-phase microextraction-gas chromatography-mass spectrometry.

The purpose of this study was to develop a simple and accurate analytical method to determine homocysteine (Hcy), cysteine (Cys), and methionine (Met) in aqueous samples. Until now, the most frequently used method for the assay of Hcy, Cys, and Met has been high-performance liquid chromatography with fluorescence detection after fluorescent tagging. The newly developed method involves the employment of the SPME (solid-phase microextraction) technique together with GC-MS. For application to a gas chromatographic system, alkyl formate derivatives were prepared in the form of N(O,S)-alkoxycarbonyl alkyl ester with the analytes in the aqueous samples. The optimum derivatizing regent for N(O,S)-alkoxycarbonyl alkyl ester was chosen by comparing the efficiency of the derivatized analytes in a GC through the SPME method and liquid-liquid extraction. The optimum conditions of the SPME system for the analytes derivatized with N(O,S)-ethoxycarbonyl propyl ester in the aqueous matrix were pH 3.0 and no salt, and 30 min equilibration time using an 85 microm PA (polyacrylate) fiber. The developed method is inexpensive, easy and rapid.

Calibration↗

Determination of ethylphenols in wine by in situ derivatisation and headspace solid-phase microextraction-gas chromatography-mass spectrometry.

Contamination by Brettanomyces is a frequent problem in many wineries that has a dramatic effect on wine aroma and hence its quality. The yeast Brettanomyces/Dekkera is involved in the formation of three important volatile ethylphenols-4-ethylphenol, 4-ethylguaiacol and 4-ethylcatechol-that transmit an unpleasant aroma to wine that has often been described as 'medicinal', 'stable' or 'leather'. This study proposes an in situ derivatisation and headspace solid-phase microextraction- gas chromatography coupled to mass spectrometry method to determine the three ethylphenols in red Brettanomyces-tainted wines. The most important variables involved in the derivatisation (acetic anhydride and base concentration) and the extraction (extraction temperature and salt addition) processes were optimised by experimental design. The optimal conditions using 4 mL of wine in 20-mL sealed vials were 35 muL of acetic anhydride per millilitre of wine, 1 mL of 5.5% potassium carbonate solution and 0.9 g of sodium chloride and the extraction was performed with a divinylbenzene-carboxen-poly(dimethylsiloxane) fibre at 70 degrees C for 70 min. Then, the performance characteristics were established using wine samples spiked with the ethylphenols. For all compounds, the detection limits were below the odour threshold reported in the literature and they were between 2 and 17 microg L(-1) for 4-ethylguaiacol and 4-ethylphenol, respectively. Intermediate precision (as relative standard deviation) was acceptable, with values ranging from 0.3 to 12.1%. Finally, the method was applied in the analysis of aged Brettanomyces-tainted wines.

Journal Article↗

Headspace solid-phase microextraction-gas chromatography--mass spectrometry analysis of the volatile compounds of Evodia species fruits.

In this study the investigation of the aroma compounds of dried fruits of Evodia rutaecarpa (Juss.) Benth. and E. rutaecarpa (Juss.) Benth. var. officinalis (Dode) Huang (i.e. E. officinalis Dode) (Rutaceae family) was carried out to identify the odorous target components responsible for the characteristic aroma of these valuable natural products. To avoid the traditional and more time-consuming hydrodistillation, the analyses were carried out by means of headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). The SPME headspace volatiles were collected using a divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fiber. The extraction conditions were optimized using a response surface experimental design to analyze the effect of three factors: extraction temperature, equilibrium time and extraction time. The best response was obtained when the extraction temperature was around 80 degrees C, equilibrium time near 25 min and extraction time close to 18 min. Analyses were performed by GC-MS with a 5% diphenyl-95% dimethyl polysiloxane (30 m x 0.25 mm I.D., film thickness 0.25 microm) capillary column using He as the carrier gas and a programmed temperature run. The main components of the HS-SPME samples of E. rutaecarpa (concentration >3.0%) were limonene (33.79%), beta-elemene (10.78%), linalool (8.15%), myrcene (5.83%), valencene (4.73%), beta-caryophyllene (4.62%), linalyl acetate (4.13%) and alpha-terpineol (3.99%). As for E. officinalis, the major compounds were myrcene (32.79%), limonene (18.36%), beta-caryophyllene (9.92%), trans-beta-ocimene (6.04%), linalool (5.88%), beta-elemene (7.85%) and valencene (4.62%).

Evodia↗

Strategies for the microextraction of polar organic contaminants in water samples.

In this paper the most recent developments in the microextraction of polar analytes from aqueous environmental samples are critically reviewed. The particularities of different microextraction approaches, mainly solid-phase microextraction (SPME), stir-bar-sorptive extraction (SBSE), and liquid-phase microextraction (LPME), and their suitability for use in combination with chromatographic or electrically driven separation techniques for determination of polar species are discussed. The compatibility of microextraction techniques, especially SPME, with different derivatisation strategies enabling GC determination of polar analytes and improving their extractability is revised. In addition to the use of derivatisation reactions, the possibility of enhancing the yield of solid-phase microextraction methods for polar analytes by using new coatings and/or larger amounts of sorbent is also considered. Finally, attention is also focussed on describing the versatility of LPME in its different possible formats and its ability to improve selectivity in the extraction of polar analytes with acid-base properties by using separation membranes and buffer solutions, instead of organic solvents, as the acceptor solution.

Journal Article↗

Solid-phase microextraction-gas chromatographic-mass spectrometric analysis of garlic oil obtained by hydrodistillation.

Garlic (Allium sativum L.) is highly consumed worldwide. This crop is mainly known for its flavor and odor, although the many medicinal properties that are attributed to it, including anticarcinogenic, antiatherosclerotic, and antithrombotic potential, among several others, have called the attention of scientists since very early times. It is known that sulfur-containing volatiles are the principal compounds responsible for such properties. The aims of this work were to develop a solventless extraction method for sulfur-containing volatiles from garlic, as well as their chemical characterization. Since garlic volatiles are rather thermolabile, low-pressure hydrodistillation was chosen as the extracting method. The analysis of all compounds was performed on an HP-FFAP chromatographic column mounted in a GC-MS system. For volatile transfer and injection method, solid-phase microextraction was selected, with the use of eight different fibers. The most abundant volatile compound was diallyl disulfide, followed by diallyl trisulfide. Among the 47 totally identified compounds, 18 were linear sulfur-containing volatile compounds, 6 were of non-sulfur nature, and the other 23 were cyclic compounds. However, linear sulfur volatiles accounted for 94% of the total amount.

Allyl Compounds↗

High-throughput analysis of bergamot essential oil by fast solid-phase microextraction-capillary gas chromatography-flame ionization detection.

The advantages of using a narrow-bore column in headspace solid-phase microextraction-gas chromatographic (HS-SPME-GC) analysis are investigated. An automated rapid HS-SPME-GC method for the determination of volatile compounds in a complex sample (bergamot essential oil) was developed. A low-capacity (7 microm) SPME fibre was employed, enabling a short equilibration time (15 min). The absorbed volatile compounds were then separated in 12.5 min on a 10 m x 0.1 mm I.D. capillary. The fast GC method was characterized by relatively moderate GC parameters (head pressure: 173 kPa; temperature program rate: 12 degrees C/min). The employment of the low-capacity fibre also suited the reduced sample capacity of the capillary employed, hence column overloading was avoided. Analytical repeatibility was determined in terms of retention times (maximum RSD: 0.32%) and peak areas (maximum RSD: 9.80%). The results obtained were compared to those derived from a conventional HS-SPME-GC (a 30 microm SPME fibre and 0.25 mm I.D. capillary were used) application on the same sample. In this respect, a great reduction of analytical time was obtained both with regard to the conventional SPME equilibration and GC run times, which both required 50 min. Peak resolution was altogether comparable in both applications. Although a slight loss in terms of sensitivity was observed in the rapid approach (generally within the 25-50% range), this did not impair the detection of all peaks of interest. Finally, the selectivities of the 30 and 7 microm fibres were evaluated and, as expected, these were in good agreement.

Chemical Fractionation↗

Solid-phase microextraction-based approach to determine free-base nicotine in trapped mainstream cigarette smoke total particulate matter.

Characterizing nicotine delivery from tobacco products is important in the understanding of their addictive potential. Most previous studies report total nicotine and have not differentiated between nicotine in its protonated or free-base form. Rather than simply determining total nicotine, the method described in this paper determines the amount of free-base nicotine associated with trapped mainstream smoke particulate matter generated using a standardized smoking machine protocol. This method quantitatively determines volatile free-base nicotine associated with the particulate phase portion of mainstream cigarette smoke using solid-phase microextraction combined with gas chromatography-mass spectrometry. The headspace above total particulate matter from mainstream cigarette smoke trapped on a Cambridge filter pad (CFP) was analyzed for free-base nicotine in 26 cigarette brands. The selected cigarette brands were chosen to cover a wide range of tar and nicotine deliveries as measured under Federal Trade Commission machine smoking conditions. In the CFP's headspace the free-base nicotine levels ranged from 0.01 to 0.08 mg/cigarette. The measured ranges of free-base nicotine were remarkably similar over the different tar and nicotine delivery categories of full-flavored, light, and ultralight cigarette brands.

Gas Chromatography-Mass Spectrometry↗

Direct quantitation of volatile organic compounds in packaging materials by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

The quantification of volatile organic compounds (VOCs) in flexible multilayer packaging materials using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) was studied. The analytes imclude 22 compounds such as aldehydes. ketones, carboxylic acids and hydrocarbons formed by thermooxidative degradation of polyethylene during the extrusion coating process in the manufacture of the packaging, and many of them are involved in the unpleasant and undesirable odour of these materials. External standard calibration using a solution of the analytes in an appropriate solvent was the first approach studied. Aqueous solutions of the analytes provided low reproducibility and the reduction of aldehydes to alcohols under the HS-SPME conditions. Hexadecane was chosen as the solvent since its polarity is similar to that of polyethylene and its volatility is lower than that of the analytes. However, hexadecane should be added to the sample before the analysis as it modifies the absorption capacity of the fibre. A 75-microm Carboxen-poly(dimethylsiloxane) fibre was used to extract the VOCs from the headspace above the packaging in a 15-ml sealed vial at 100 degrees C after 5 min of preincubation. The influence of the extraction time on the amount extracted was studied for a standard solution of the analytes in hexadecane, together with the influence of the volume of the standard solution and the amount of the sample placed in the vial. Standard addition and multiple HS-SPME were also studied as calibration methods and the results obtained in the quantitative analysis of a packaging material were compared.

Calibration↗

Headspace solid-phase microextraction-gas chromatography-mass spectrometry applied to quality control in multilayer-packaging manufacture.

A method based on headspace solid-phase microextraction-gas chromatography-mass spectrometry is proposed for the quality control of multilayer packaging and its manufacturing process. Volatile organic compounds (VOCs) are produced in the manufacturing process of the packaging. They can cause organoleptic problems or modify the properties of the packaging depending on the nature and the amount of the VOCs formed. The quantification using packaging samples with a known VOC concentration for the calibration is proposed in order to reduce the analysis time, and the method is validated using a statistical test. Finally, the method is applied to the determination of odour-responsible compounds in multilayer packaging samples obtained under different extrusion-coating conditions, i.e. type of extruder, type of polymer and extrusion speed.

Calibration↗

Solventless sample preparation for pesticides analysis in environmental water samples using solid-phase microextraction-high resolution gas chromatography/mass spectrometry (SPME-HRGC/MS).

Solid-phase micro-extraction (SPME) coupled on line with high resolution gas chromatography and mass spectrometric detection is described for the analysis of pesticides in environmental water samples. Experiments were performed in order to optimize the SPME extraction conditions for selected pesticides including tiomethon, trichorfon, dimethoate, diazinon, malathion, dicofol, methidathion, ethion, bromopropylate and pyrazophos from spiked water solutions. To enhance the SPME efficiency, experimental conditions including the fiber composition, stirring rate, temperature, adsorption time, desorption time and salt concentration were optimized. After validation, the SPME-GC/MS methodology was applied to real-world environmental water samples.

Acrylic Resins↗

Simultaneous detection of some drugs of abuse in saliva samples by SPME technique.

A simple method for the simultaneous determination of many drugs of abuse in saliva is referred [methadone, 2-ethyl-1,5-dimethyl-3,3-diphenylpyrrolinium perchlorate (EDDP), cocaine, cocaethylene, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethyl amphetamine (MDEA), N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine (MBDB), cannabidiol (CBD), Delta(9)-tetrahydrocannabinol (THC), cannabinol (CBN)]. Head space-solid phase microextraction (HS-SPME) and direct immersion-solid phase microextraction (DI-SPME) followed by gas chromatographic/mass spectrometric analyses (GC/MS) were employed, and results obtained with both techniques are discussed. The method was validated testing reproducibility, sensitivity, linearity.

Forensic Medicine↗