PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HPLC gradient formation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Analysis of lipoxygenase kinetics by high-performance liquid chromatography with a polymer column.

Soybean lipoxygenase (LOX; EC 1.12.11.12) catalyzes the oxygenation of polyunsaturated fatty acids, acylglycerols and phosphoglycerols, producing a regio- and enantiospecific hydroperoxide product. The goal of this work was to measure the relative rate of LOX-catalyzed oxidation of mixtures of lipids containing linoleate, using high-performance liquid chromatography (HPLC) and a light-scattering detector (LSD). Previous literature suggested that reversed-phase HPLC with silica-based columns could be used for the separation of individual fatty acids, acylglycerols, phosphoglycerides and their oxidation products. However, these columns produced ineffective separations of phosphoglycerides unless choline chloride and a strong base, such as KOH, are present in the mobile phase. Such modifiers precluded the use of the LSD. It was found that a reversed-phase column based upon an organic polymer support, rather than on silica, was able to separate these mixtures with a ternary solvent gradient of methanol/water/acetonitrile without the need for the addition of modifiers. The oxidation time course of a mixture of linoleic acid, trilinolein and 1-linoleoyl-2-stearoyl-sn-glycero-3-phosphocholine was followed using the developed HPLC method. The results showed that trilinolein and phosphatidylcholine reacted at one-tenth the rate of linoleic acid. The diacylglycerol, 1,3-dilinolein, was oxidized at a rate that was approximately 40% that of linoleic acid, with the formation of mono- and dihydroperoxides as well as other unidentified products.

Chromatography, High Pressure Liquid↗

Direct measurement of steroid sulfate and glucuronide conjugates with high-performance liquid chromatography-mass spectrometry.

Direct detection of several steroid glucuronide and sulfate conjugates was achieved with electrospray reversed-phase HPLC-mass spectrometry. Separation of steroid 17-OH or 5-H epimers conjugated with glucuronide or sulfate could be achieved using gradient elution. Testosterone glucuronide, testosterone sulfate, epitestosterone sulfate and epitestosterone glucuronide were chromatographically resolved, although significant variation in solvent strength was observed between methanol and acetonitrile. Positive ionization mode MS and MS-MS spectra were employed to obtain both quantitative and structural information. Some differences were noted with respect to steroid structure and adduct formation, including significant differences in the stability of epimers in the declustering region of the interface. Negative ionization mode, although having lower limits of detection, did not provide useful structural information in either the MS or MS-MS mode. Using a packed capillary column (300 microns I.D.), a detection limit of 25 pg was achieved for epitestosterone glucuronide.

Chromatography, High Pressure Liquid↗

Kinin formation by catheptic enzyme in rat stomach.

Four uterine-contractile substances (a, b, c and d) were extracted from procedures with acetic acid, n-butanol, distilled water, and methanol from the reaction mixture obtained by incubating rat plasma kininogen with the kininforming enzyme in the rat stomach. Gradient and equilibrium chromatography on SP-Sephadex C-25 columns were carried out with the extract containing these materials (a, b, c and d). The materials could not be separated by chromatography on SP-Sephadex C-25, but were separated by high performance liquid chromatography (HPLC) with a Zorbax ODS reversed-phase column. All the materials (a, b, c and d) contracted the rat uterus and relaxed the rat duodenum. The uterine-contractile activity of the materials was abolished by chymotrypsin, but not by trypsin treatment. The retention times of materials a, c and d on HPLC were different from that of kallidin, MLBK, bradykinin (BK) and neurotensin; but the retention time of material b was equal to that of BK. The content ratio of a: b: c: d was 4: 4: 67: 25, calculated from the uterine-contractile activity of these materials. The apparent molecular weight of the major material c, estimated by gel chromatography, was 1650. Material c contracted the rat uterus (1.2 x 10(-10) g/ml), relaxed the rat duodenum (2 x 10(-10) g/ml), and produced a fall in rabbit blood pressure (4.4 x 10(-8) g/kg). Material c was classified as a biologically BK-like peptide which is distinct from kallidin, MLBK, BK and neurotensin.

Animals↗

Confirmatory assay for the determination of tetracycline, oxytetracycline, chlortetracycline and its isomers in muscle and kidney using liquid chromatography-mass spectrometry.

A confirmatory method is described for the determination of tetracycline, oxytetracycline and chlortetracycline in muscle and kidney using liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry. The tetracyclines were extracted from tissue using glycine-HCl buffer and concentrated using solid-phase extraction. HPLC separation was carried out using a gradient and the tetracyclines were detected using a bench-top LC-MS system. Several ions could be monitored for each tetracycline, allowing ion ratio measurements to be made. The detection limits for the assay were in the region of 10 ng/g in muscle and 20 ng/g in kidney. Validation was carried out at half the maximum residue limit, the maximum residue limit and two times the maximum residue limit. The formation of epimers and tautomers of the tetracyclines, their presence in incurred tissues and difficulties in their accurate quantitation is discussed.

Chromatography, Liquid↗

HPLC determination of ciprofloxacin, cloxacillin, and ibuprofen drugs in human urine samples.

This paper reports, for the first time, a liquid chromatographic method for the simultaneous determination of three frequently co-administered active principles, two antibiotics, ciprofloxacin (CIPRO) and cloxacillin (CLOXA) belonging to the fluoroquinolones and beta-lactam families, respectively, and ibuprofen (IBU), a non-steroidal anti-inflammatory drug. The chromatographic separation was performed on a C-18 analytical column, using isocratic elution with methanol-acetonitrile-pH 3 formate buffer (CT = 0.1 M) (15:12:73, v/v/v) for 3 min and, after that, a linear gradient with methanol-acetonitrile (88:12, v/v) for 8 min. Several absorption spectra were obtained for each peak using a DAD detector. Chromatograms at the maximum absorption wavelength for each analyte, 220 nm for both IBU and CLOXA, and 280 nm for CIPRO were selected as the most suitable. The proposed chromatographic method requires about 15 min per sample. The presence of a urine background was tested and no interference was found. The method was satisfactorily applied to the determination of CIPRO, CLOXA, and IBU, in fortified urine, and in urine samples from a patient undergoing treatment with these three active principles, among others. Limits of quantification in urine were 1.00, 1.70, and 2.87 microg/mL for CIPRO, CLOXA, and IBU, respectively.

Anti-Bacterial Agents↗

Tryptic digest mapping by gradient capillary electrochromatography.

A high performance liquid chromatography (HPLC) system complemented with T-split, capillary detection cell and a high voltage power supply was used for peptide mapping by gradient electrochromatography and nanoliquid chromatography (nano-LC). With capillary columns of 100 microm ID, 6 cm packed with octadecylated 1.5 microm silica particles, the typical analysis time was approximately 10-15 min. The resolution of a tryptic digest of cytochrome c obtained by electrochromatography at 100 kV/m was superior compared to the analysis by nano-LC. Bubble formation caused by Joule heating at currents up to 100 microA was successfully suppressed by using a resistor capillary of 25 microm ID connected to the outlet of the packed column.

Chromatography, Liquid↗

Multiparallel chiral method development screening using an 8-channel microfluidic HPLC system.

The Eksigent Express 800 8-channel microfluidic HPLC system was investigated for carrying out multiparallel screening and development of fast normal phase chiral separations. In contrast to the familiar automated sequential chiral method development approaches that often afford a next day result, the multiparallel approach offers the exciting possibility of near "real time" method development, often affording an optimized method in less than 1 h. In this study, four column types (300 microm i.d.) with two different mobile phases are screened using a universal standard gradient approach. Interestingly, parallel method optimization following initial screening was shown to sometimes lead to surprising and unanticipated outcomes, emphasizing the value of the multiparallel screening approach. A variety of standard test racemates were analyzed, with optimized separation methods for most in the 1- to 2-min range. These results compare favorably with results obtained on a single channel conventional HPLC system using 4.6-mm i.d. columns. In addition, isocratic methods developed on the microbore columns are readily translated to the larger column format.

Benzoin↗

High-throughput peptide synthesis and peptide purification strategy at the low micromol-scale using the 96-well format.

The increasing demand for short- and medium-sized peptides in many fields of biological, medical and pharmaceutical research requires optimized and universally applicable high-throughput synthesis and purification techniques at the low-micromol scale. Here, we describe a continuous peptide synthesis/purification approach using the 96-well format. First, a micromol scale peptide synthesis on resin beads was optimized on a novel miniaturized 96-reaction vessel block employing standard Fmoc/tBu-chemistry. Almost 90% of the synthesized peptides contained the target sequence as the main component, as judged from matrix-assisted laser desorption/ionization (MALDI) mass spectra. Impurities were mostly related to partially protected peptides. Second, we tested the applicability of ion pair reversed-phase solid-phase extraction (IP-RP-SPE) to purify individual peptides. Depending on the length and predicted hydrophobicity of the peptides, elution was performed with 25 or 35% aqueous acetonitrile in the presence of 0.1% trifluoroacetic acid (TFA). Thus, scavengers used during TFA cleavage and partially protected peptides carrying very hydrophobic protecting groups were effectively removed. Using a narrow step gradient, the target peptides were even separated from deleted sequences and protected peptides with similar hydrophobicities. Third, we combined the micromol-scale synthesis in the 96-well format with purification by IP-RP-SPE on a 96-well micro-extraction plate format. This simple, fast and parallel approach was tested on 12-mer and 15-mer peptides to map epitopes of T- and B-cell clones, respectively. Approximately 80% of all peptides were obtained at purities > 90% without purification by RP-HPLC. In summary, this novel approach has several advantages: (i) the micromol-scale reduced the cost of peptide synthesis, (ii) large numbers of peptides were purified faster, (iii) the volumes of eluents and waste were significantly reduced, and (iv) the RP-HPLC column was not contaminated with hydrophobic impurities.

Acetonitriles↗

Determination of the cardiac glycosides digoxin and digitoxin by liquid chromatography combined with isotope-dilution mass spectrometry (LC-IDMS)--a candidate reference measurement procedure.

This article describes a method of high analytical sensitivity, reproducibility and trueness for the determination of digoxin and digitoxin in serum or plasma at therapeutic levels using a combination of high-pressure liquid chromatography (HPLC), isotope-dilution mass spectrometry (IDMS) and caesium-adduct formation. A method for threefold deuterium substitution in the glycosides was developed, which could be performed within 24 hours without distillation giving yields > 98% of the theoretical value. Extraction from a serum or plasma matrix was performed using a liquid-phase extraction with ammonium acetate buffer/tertiary butylmethyl ether/ethyl acetate at pH 9.5. The HPLC-separation used a 10 x 2 mm LiChrospher RP-18 5 microm guard column in combination with a 125 x 2 mm main column of the same material and a gradient containing methanol, caesium ions and formic acid. Quantification of digoxin and digitoxin was made with IDMS using deuterated internal standards and the system run in single ion monitoring (SIM) mode. The methods had a lower limit of determination of 0.25 microg/l for digoxin and digitoxin, a trueness between 97.5 and 104% for digoxin and between 98 and 101% for digitoxin, respectively and had a coefficient of variation of less than 3% in the therapeutic range for both glycosides. Maximally 1 ml serum or plasma was needed for the procedure. The method is used to set target values for materials used in external quality assessment surveys (EQAS) run by INSTAND as part of a national EQAS-programme.)

Calibration↗

Simultaneous determination of testosterone metabolites in liver microsomes using column-switching semi-microcolumn high-performance liquid chromatography.

A sensitive and selective column-switching semi-microcolumn high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of testosterone and eight of its metabolites (6alpha-, 6beta-, 16alpha-, 16beta-, 7alpha-, 2alpha-, and 2beta-hydroxytestosterone, and androstenedione) in liver microsomes. After incubation for 10 min, testosterone and its metabolites were extracted from the microsomes with ethyl acetate, and the extract was evaporated to dryness. The residue was dissolved in the mobile phase and loaded onto the HPLC system. The analytes were first concentrated in a precolumn and subsequently transferred to the analytical column, where they were separated using linear gradient elution. A UV detector set at 254 nm was used to detect the analytes. This newly developed method clearly separated TES and the metabolites with high resolution and was found to be reproducible with intra- and interday variability of <10.7%. This method has been subsequently used to determine the testosterone hydroxylation activities catalyzed by 15 different recombinant CYP isozymes. The results confirmed the formation of stereoselectively hydroxylated metabolites by each CYP isozyme.

Animals↗

Human plasma distribution of free paclitaxel and paclitaxel associated with diblock copolymers.

Amphiphilic diblock copolymer poly (D,L-lactide)-block-methoxy polyethylene glycol was synthesized, and paclitaxel (Taxol) was incorporated into this copolymer above its critical micelle concentration (cmc), resulting in the formation of polymeric micellar paclitaxel (PMT). Free paclitaxel dissolved in acetonitrile (TAX) and PMT, at 10 micrograms of paclitaxel/mL of human plasma, were incubated for 5, 30, and 60 min at 37 degrees C. Following incubation, the plasma was separated into its high-density (HDL), low-density (LDL), very-low-density (VLDL) lipoprotein and lipoprotein-deficient (LPDP) plasma fractions by density gradient ultracentrifugation. Each of these lipoprotein (LP) and LPDP fractions were analyzed for paclitaxel and plasma lipid levels by well-established HPLC and enzymatic assays. When TAX was incubated in human plasma for 5 min, an equal amount of drug was found in the LP and LPDP fractions. This distribution profile did not change following incubation for 30 and 60 min. Of the amount of TAX that was distributed within the LP fraction, 70-75% of TAX was associated with the HDL fraction for all time points studied. The paclitaxel plasma and LP distribution profile for PMT was similar to the distribution profile of TAX, suggesting that the plasma and LP distribution of paclitaxel is independent of the method of paclitaxel delivery and that LP distribution is not a function of mass lipid levels.

Antineoplastic Agents, Phytogenic↗

Use of denaturing HPLC to provide efficient detection of mutations causing guanidinoacetate methyltransferase deficiency.

Guanidinoacetate methyltransferase (GAMT) deficiency is an autosomal recessive error of creatine synthesis characterized by cerebral creatine deficiency, accumulation of guanidinoacetate, mental retardation, epilepsy, and extrapyramidal symptoms. To date, 14 mutations of the GAMT gene in 27 patients have been reported. Mutation analysis was done using direct sequencing of PCR products and denaturing gradient gel electrophoresis in combination with direct sequencing. In contrast, we evaluated the efficiency of a newly developed DHPLC method to detect mutations in the GAMT gene by analysing DNA from 14 GAMT patients with known mutations. PCR amplification of both patient and control DNA was followed by formation of homoduplices and heteroduplices, and their detection by DHPLC. DHPLC identified all mutations tested and is the preferred choice of analytical method.

Base Sequence↗

Toward single-calibrant quantification in HPLC. A comparison of three detection strategies: evaporative light scattering, chemiluminescent nitrogen, and proton NMR.

There is an urgent need for detection technologies that enable accurate and precise quantification of solutions containing small organic molecules in a manner that is rapid, cheap, non-labor-intensive, readily automated, and without a requirement for specific analyte standards. We provide a theoretical analysis that predicts that the logarithmic nature of the working domain of the evaporative light-scattering detector (ELSD) will normally bias toward underestimation of chromatographically resolved impurities, resulting in an overestimation of analyte purity. This analysis is confirmed by experiments with flow injection analysis (FIA) and gradient reversed-phase high performance liquid chromatography (RP-HPLC). Quantification is further compromised by the dependence of response parameters on the matrix composition and hence on the retention time of the analyte. Attempts were made to ameliorate these problems by using the response surface of a single compound to calibrate throughout the HPLC gradient. A chemiluminescent nitrogen detector (CLND) was also used in a similar manner, and the performance of the two techniques were compared against those of each other and that of a reference standard technique. A protocol for this purpose was developed using proton nuclear magnetic resonance (1H NMR) and the ERETIC method to enable quantification by integrating proton signals. The double-blind comparison exercise confirmed molar nitrogen CLND response to be sufficiently stable and robust across a methanol gradient to be used with a single external nitrogenous calibrant to quantify nitrogen-containing compounds of known molecular formula. The performance of HPLC-CLND was very similar to that of NMR, while that of HPLC-ELSD was seen to be significantly worse, showing it to be unsuitable for the purpose of single-calibrant quantification. We report details and experience of our use of RP-HPLC-CLND-MS to characterize and quantify small amounts of solutions of novel compounds at nominal levels of 10mM in microtiter plate (MTP) format.

Journal Article↗

Gradient high-performance liquid chromatographic analysis of enkephalin peptides, their metabolites, and enzyme inhibitors using combined ultraviolet and electrochemical detection II. Application to ocular permeability studies in vitro.

A gradient HPLC method with combined ultraviolet (UV) and electrochemical detection (ED) was used to study the ocular permeability of [D-Ala2]-methionine enkephalinamide (MEA) in vitro. Coulometric ED was selective for MEA and its tyrosine-containing metabolites with quantitation limits between 20 and 60 nM (1.0-3.0 pmol per 50-microl injection), whereas UV detection at 205 nm allowed the determination of several aromatic metabolites and enzyme inhibitors with quantitation limits between 40 and 500 nM (2.0-25.0 pmol). This method was capable of detecting permeability of MEA and metabolite formation in the cornea and conjunctiva in vitro. Furthermore, effects of aminopeptidase inhibitor bestatin and enkephalinase inhibitor SCH 39370 on permeation and metabolism of MEA could be determined.

Aminopeptidases↗

Direct measurement of salicylphenolic glucuronide in human urine.

Indirect measurement of salicylphenolic glucuronide (SPG) has suggested that the formation of this metabolite from therapeutic doses of salicyclic acid (SA) is capacity-limited in humans. A direct high performance liquid chromatographic (HPLC) assay for SPG in human urine is described. SPG was prepared by a published method and purified by HPLC. On treatment with beta-glucuronidase, SPG yielded the expected amount of SA. Spectroscopic data, melting point, and optical rotation of the glucuronide and/or its triacetyl dimethyl ester derivative were consistent with the proposed structure. SPG was assayed using a 5-micron C18 column (temperature 55 degrees C) and fluorescence detection. A nonlinear gradient mobile phase at a flow rate of 2 ml/min was used, beginning with 100% 0.1 M pH 2.1 phosphate buffer and finishing with 84% buffer, 16% acetonitrile. Total run time was 25 min. Urine (10 microliter) was injected directly on the column, and quantitation was performed using urine standards. Within-run precision for SPG ranged from 1.2% at 150 mg/L to 2.4% at 5 mg/L. The limit of detection was less than 1 mg/L. A pilot study in two volunteers, each receiving a single 500-mg dose of sodium salicylate, was carried out to validate the usefulness of the assay.

Adult↗

Alternative high-performance liquid chromatographic peptide separation and purification concept using a new mixed-mode reversed-phase/weak anion-exchange type stationary phase.

This article describes a new complementary peptide separation and purification concept that makes use of a novel mixed-mode reversed-phase/weak anion-exchange (RP/WAX) type stationary phase. The RP/WAX is based on N-(10-undecenoyl)-3-aminoquinuclidine selector, which is covalently immobilized on thiol-modified silica particles (5 microm, 100 A pore diameter) by radical addition reaction. Remaining thiol groups are capped by radical addition with 1-hexene. This newly developed separation material contains two distinct binding domains in a single chromatographic interactive ligand: a lipophilic alkyl chain for hydrophobic interactions with lipophilic moieties of the solute, such as in the reversed-phase chromatography, and a cationic site for anion-exchange chromatography with oppositely charged solutes, which also enables repulsive ionic interactions with positively charged functional groups, leading to ion-exclusion phenomena. The beneficial effect that may result from the combination of the two chromatographic modes is exemplified by the application of this new separation material for the chromatographic separation of the N- and C-terminally protected tetrapeptide N-acetyl-Ile-Glu-Gly-Arg-p-nitroanilide from its side products. Mobile phase variables have been thoroughly investigated to optimize the separation and to get a deeper insight into the retention and separation mechanism, which turned out to be more complex than any of the individual chromatography modes alone. A significant anion-exchange retention contribution at optimal pH of 4.5 was found only for acetate but not for formate as counter-ion. In loadability studies using acetate, peptide masses up to 200 mg could be injected onto an analytical 250 mm x 4 mm i.d. RP/WAX column (5 microm) still without touching bands of major impurity and target peptide peaks. The corresponding loadability tests with formate allowed the injection of only 25% of this amount. The analysis of the purified peptide by capillary high-performance liquid chromatography (HPLC)-UV and HPLC-ESI-MS employing RP-18 columns revealed that the known major impurities have all been removed by a single chromatographic step employing the RP/WAX stationary phase. The better selectivity and enhanced sample loading capacity in comparison to RP-HPLC resulted in an improved productivity of the new purification protocol. For example, the yield of pure peptide per chromatographic run on RP/WAX phase was by a factor of about 15 higher compared to the standard gradient elution RP-purification protocol.

Anion Exchange Resins↗

Simultaneous quantification of retinol, retinal, and retinoic acid isomers by high-performance liquid chromatography with a simple gradiation.

A new method of high-performance liquid chromatography (HPLC) analysis to quantify isomers of retinol, retinal and retinoic acid simultaneously was established. The HPLC system consisted of a silica gel absorption column and a linear gradient with two kinds of solvents containing n-Hexane, 2-propanol, and glacial acetic acid in different ratios. It separated six retinoic acid isomers (13-cis, 9-cis, all-trans, all-trans-4-oxo, 9-cis-4-oxo, 13-cis-4-oxo), three retinal isomers (13-cis-, 9-cis-, and all-trans) and two retinol isomers (13-cis- and all-trans). Human serum samples were subjected to this HPLC analysis and at least, all-trans retinol, 13-cis retinol, and all-trans retinoic acid were detectable. This HPLC system is useful for evaluating retinoic acid formation from retinol via a two-step oxidation pathway. Moreover, it could be applied to monitoring the concentrations of various retinoids, including all-trans retinoic acid in human sera.

Chromatography, High Pressure Liquid↗

The microbial degradation of azimsulfuron and its effect on the soil bacterial community.

AIMS: Azimsulfuron is a recently introduced sulfonylurea herbicide useful in controlling weeds in paddy fields. To date very little information is available on the biodegradation of this pesticide and on its effect on the soil microbial community. The aim of this work was to study its biodegradation both in slurry soil microcosms and in batch tests with mixed and pure cultures. METHODS AND RESULTS: Azimsulfuron was applied to forest bulk soil in order to study its effect on the structure of the bacterial soil community, as detectable by denaturant gradient gel electrophoresis (DGGE) analyses. Biodegradation and abiotic processes were investigated by HPLC analyses. In addition, a microbial consortium was selected, that was able to use azimsulfuron as the sole energy and carbon source. One of the metabolites produced by the consortium was isolated and identified through LC-MS analyses. Cultivable bacteria of the consortium were isolated and identified by 16S rDNA sequencing (1400 bp). CONCLUSIONS: Azimsulfuron treatment seems to have the ability to cause changes in the bacterial community structure that are detectable by DGGE analyses. It is easily biodegraded both in microcosms and in batch tests, with the formation of an intermediate that was identified as 2-methyl-4-(2-methyl-2H-tetrazol-5-yl)-2H-pyrazole-3-sulfonamide. SIGNIFICANCE AND IMPACT OF THE STUDY: The study increases the knowledge on the biodegradation of azimsulfuron and its effects on the soil microbiota.

Bacteria↗