PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Developments toward a microfluidic system for long-term monitoring of dynamic cellular events in immobilized human cells.

A microfluidic system for long-term real-time monitoring of dynamic cellular events of immobilized human cells was investigated. The luciferase reporter gene activity in the reporter cell line HFF11, based on HeLa cells, was used as the model system. The cells were immobilized on silicon flow-through microchips and continuously supplied with a cell medium at 2 microL/min while maintaining the chip at 37 degrees C. The HFF11 cell line was designed for high-throughput screening of ligands for seven-transmembrane receptors. When a ligand binds, the receptor is activated and a cascade of intracellular reactions starts, ending with the synthesis of the reporter protein Photinus luciferase. The major goal was to develop a microfluidic system for continuous long-term assaying of the intracellular reporter gene activity in real time and determine the conditions, which could minimize cells stress and hence unspecific expression of the reporter gene. In the resulting microfluidic system and assay protocol, the cell microchip could be kept and assayed for a period up to 30 h. The developed system and data outcome was compared with a corresponding microtiter plate performed with the same cell line to highlight the advantages obtained in the microfluidic format.

Animals↗

Torque-actuated valves for microfluidics.

This paper describes torque-actuated valves for controlling the flow of fluids in microfluidic channels. The valves consist of small machine screws (> or =500 microm) embedded in a layer of polyurethane cast above microfluidic channels fabricated in poly(dimethylsiloxane) (PDMS). The polyurethane is cured photochemically with the screws in place; on curing, it bonds to the surrounding layer of PDMS and forms a stiff layer that retains an impression of the threads of the screws. The valves were separated from the ceiling of microfluidic channels by a layer of PDMS and were integrated into channels using a simple procedure compatible with soft lithography and rapid prototyping. Turning the screws actuated the valves by collapsing the PDMS layer between the valve and channel, controlling the flow of fluids in the underlying channels. These valves have the useful characteristic that they do not require power to retain their setting (on/off). They also allow settings between "on" and "off" and can be integrated into portable, disposable microfluidic devices for carrying out sandwich immunoassays.

Immunoassay↗

Microfluidic separation and gateable fraction collection for mass-limited samples.

Integrating multiple analytical processes into microfluidic devices is an important research area required for a variety of microchip-based analyses. A microfluidic system is described that achieves preparative separations by intelligent fraction collection of attomole quantities of sample. The device consists of a main microfluidic channel used to perform electrophoresis, which is interconnected at 90 degrees to two vertically displaced channels via a nanocapillary array membrane. The membrane interconnect contains nanometer-diameter pores that provide fluidic communication between the channels. Sample injection and analyte collection are controlled by application of an electrical bias between the microfluidic channels across the nanocapillary array. After the separation, the automated transfer of the FITC-labeled Arg, Gln, and Gly bands occurs; a fluorescence detector located at the separation/collection channel interconnect is used to generate a triggering signal that initiates suitable voltages to allow near-quantitative transfer of analyte from the separation channel to the second fluidic layer. The ability to achieve such sample manipulations from mass-limited samples enables a variety of postseparation processing events.

Algorithms↗

Investigation into the applicability of the centrifugal microfluidics platform for the development of protein-ligand binding assays incorporating enhanced green fluorescent protein as a fluorescent reporter.

The incorporation of a protein-ligand binding assay into a centrifugal microfluidics platform is described. The platform itself is a disc-shaped polymer substrate, upon which a series of microfluidic channels and reservoirs have been machined. Centrifugal microfluidics platforms require no internal moving parts, and fluid propulsion is achieved solely through rotation of the disc. Fluid flow is controlled by passive valves, the opening of which is dependent on the angular frequency of the rotating platform, the channel dimensions, and the physical properties of the fluid. To evaluate the effectiveness of incorporating a protein-based assay onto the centrifugal microfluidics analytical platform, a class-selective, homogeneous assay for the detection of phenothiazine antidepressants was employed. This class of drugs is known to bind to calmodulin, a calcium binding protein. Specifically, a fusion protein between calmodulin and enhanced green fluorescent protein was utilized. Calmodulin undergoes a conformational change upon binding to phenothiazines that alters the fluorescence properties of the attached fluorescent protein, which can be correlated to the concentration of the drug present. Another important aspect of this work was to study the efficacy of the platform to perform reconstitution assays. To do this, the biological reagent was dried on the platform and rehydrated to carry out the assay. The ability to prealiquot reagents on the platform should enhance its versatility and portability. The integration of protein-based assays in this platform should be useful in the design of analytical systems for high-throughput screening of pharmaceuticals and clinical diagnostics.

Antidepressive Agents↗

Liquid membrane operations in a microfluidic device for selective separation of metal ions.

A three-phase flow, water/n-heptane/water, was constructed in a microchannel (100-microm width, 25-microm depth) on a glass microchip (3 cm x 7 cm) and was used as a liquid membrane for separation of metal ions. Surface modification of the microchannel by octadecylsilane groups induced spontaneous phase separation of the three-phase flow in the microfluidic device, which allows control of interfacial contact time and off-chip analysis using conventional analytical apparatus. Prior to the selective transport of a metal ion through the liquid membrane in the microchannel, the forward and backward extraction of yttrium and zinc ions was investigated in a two-phase flow on a microfluidic device using 2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester (commercial name, PC-88A) as an extractant. The extraction conditions (contact time of the two phases, pH, extractant concentration) in the microfluidic device were examined. These investigations demonstrated that the conventional methodology for solvent extraction of metal ions is applicable to solvent extraction in a microchannel. Finally, we employed the three-phase flow in the microchannel as a liquid membrane and observed the selective transport of Y ion through the liquid membrane. In the present study, we succeeded, for the first time, in the selective separation of a targeted metal ion from an aqueous feed solution to a receiving phase within a few seconds by employing a liquid membrane formed in a microfluidic device.

Cations↗

Pyrosequencing in a microfluidic flow-through device.

To explore genome variation meaningfully, there is a critical need for a high-throughput and inexpensive platform for DNA analysis. Pyrosequencing is a nonelectrophoretic bioluminometric DNA sequencing method that uses a four-enzyme mixture reaction to monitor nucleotide incorporation in real time. Currently, the commercialized pyrosequencing technique is limited to a 96-microtiter plate format. However, high throughput and inexpensive pyrosequencing is required to meet the need of screening large numbers of samples. We present here DNA pyrosequencing on a nanoliter-volume microfluidic platform. The microfluidic approach involves the trapping of the DNA on microbeads in an on-chip filter chamber and flow-through of the pyrosequencing reagents to monitor the reaction in real time. Two single-nucleotide polymorphisms were successfully scored to evaluate the microfluidic platform. In addition to significantly reducing reagent costs, microfluidic systems promise to improve the read length by eliminating intermediate product accumulation by constant removal of unincorporated nucleotides and elimination of dilution effects at each reaction cycle in the current plate format. Although only one filter chamber was used in this study, the platform should be readily adaptable to parallel analyses of nanoliter samples using filter chamber arrays to obtain high-throughput DNA analysis.

Base Sequence↗

Fabrication of discontinuous surface patterns within microfluidic channels using photodefinable vapor-based polymer coatings.

In this report, we introduce a surface modification method for the fabrication of discontinuous surface patterns within microfluidic systems. The method is based on chemical vapor deposition (CVD) of a photodefinable coating, poly(4-benzoyl-p-xylylene-co-p-xylylene), onto the luminal surface of a microfluidic device followed by a photopatterning step to initiate spatially controlled surface binding. During photopatterning, light-reactive groups of the CVD polymer spontaneously react with molecules adjunct to the surface, such as poly(ethylene oxide). We demonstrate the potential of these reactive polymers for surface modification by preventing nonspecific protein adsorption on different substrates including silicon and poly(dimethylsiloxane) as measured by fluorescence microscopy. More importantly, three-dimensional patterns have successfully been created within polymer-based microfluidic channels, establishing spatially controlled, bioinert surfaces. The herein reported surface modification method addresses a critical challenge with respect to surface engineering of microfluidic devices, namely, the fabrication of discontinuous patterns within microchannels.

Light↗

Microfluidic liquid chromatography system for proteomic applications and biomarker screening.

A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p < 0.001, and of 5 proteins that are known to be cancer-specific biomarkers, demonstrating thus the potential applicability of these chips for future high-throughput biomarker screening applications.

Biomarkers, Tumor↗

Microcontact printing-based fabrication of digital microfluidic devices.

Digital microfluidics is a fluid manipulation technique in which discrete droplets are actuated on patterned arrays of electrodes. Although there is great enthusiasm for the application of this technique to chemical and biological assays, development has been hindered by the requirement of clean room fabrication facilities. Here, we present a new fabrication scheme, relying on microcontact printing (microCP), an inexpensive technique that does not require clean room facilities. In microCP, an elastomeric poly(dimethylsiloxane) stamp is used to deposit patterns of self-assembled monolayers onto a substrate. We report three different microCP-based fabrication techniques: (1) selective etching of gold-on-glass substrates; (2) direct printing of a suspension of palladium colloids; and (3) indirect trapping of gold colloids from suspension. In method 1, etched gold electrodes are used for droplet actuation; in methods 2 and 3, colloid patterns are used to seed electroless deposition of copper. We demonstrate, for the first time, that digital microfluidic devices can be formed by microCP and are capable of the full range of digital microfluidics operations: dispensing, merging, motion, and splitting. Devices formed by the most robust of the new techniques were comparable in performance to devices formed by conventional methods, at a fraction of the fabrication time. These new techniques for digital microfluidics device fabrication have the potential to facilitate expansion of this technology to any research group, even those without access to conventional microfabrication tools and facilities.

Biocompatible Materials↗

Profiling pH gradients across nanocapillary array membranes connecting microfluidic channels.

Nanocapillary array membranes (NCAMs), comprised of thin (d approximately 5-10 microm) nuclear track-etched polycarbonate sheets containing approximately 10(8) cm(-2) nearly parallel nanometer-diameter capillaries, may act to gate fluid transport between microfluidic channels to effect, for example, sample collection. There is interest in H+-transport across these NCAMs because there is significant practical interest in being able to process analyte-containing samples under different pH conditions in adjacent layers of an integrated microfluidic circuit and because protons, with their inherently high mobility, present a challenge in separating microfluidic environments with different properties. To evaluate the capability of NCAMs to support pH gradients, the proton transport properties of NCAMs were studied using laser scanning confocal fluorescence microscopy (LSCFM). Spatiotemporal maps of [H+] in microfluidic channels adjacent to the NCAMs yield information regarding diffusive and electrokinetic transport of protons. The NCAMs studied here are characterized by a positive zeta potential, zeta > 0, so at small nanocapillary diameters, the overlap of electrical double layers associated with opposite walls of the nanocapillary establish an energy barrier for either diffusion or electrokinetic transport of cations through the nanometer-diameter capillaries due to the positive charge on the nanocapillary surface. Proton transfer through an NCAM into microchannels is reduced for pore diameters, d < or = 50 nm and ionic strengths I < or = 50 mM, while for large pore diameters or solution ionic strengths, the incomplete overlap of electric double layer allows more facile ionic transfer across the membranes. These results establish the operating conditions for the development of multilevel integrated nanofluidic/microfluidic architectures which can support multidimensional chemical analysis of mass-limited samples requiring sequential operations to be implemented at different pH values.

Electrochemistry↗

Microfluidic sorting of mammalian cells by optical force switching.

Microfluidic-based devices have allowed miniaturization and increased parallelism of many common functions in biological assays; however, development of a practical technology for microfluidic-based fluorescence-activated cell sorting has proved challenging. Although a variety of different physical on-chip switch mechanisms have been proposed, none has satisfied simultaneously the requirements of high throughput, purity, and recovery of live, unstressed mammalian cells. Here we show that optical forces can be used for the rapid (2-4 ms), active control of cell routing on a microfluidic chip. Optical switch controls reduce the complexity of the chip and simplify connectivity. Using all-optical switching, we have implemented a fluorescence-activated microfluidic cell sorter and evaluated its performance on live, stably transfected HeLa cells expressing a fused histone-green fluorescent protein. Recovered populations were verified to be both viable and unstressed by evaluation of the transcriptional expression of two genes, HSPA6 and FOS, known indicators of cellular stress.

Cell Separation↗

Patterned cell culture inside microfluidic devices.

This paper describes a simple plasma-based dry etching method that enables patterned cell culture inside microfluidic devices by allowing patterning, fluidic bonding and sterilization steps to be carried out in a single step. This plasma-based dry etching method was used to pattern cell-adhesive and non-adhesive areas on the glass and polystyrene substrates. The patterned substrate was used for selective attachment and growth of human umbilical vein endothelial cells, MDA-MB-231 human breast cancer cells, NIH 3T3 mouse fibroblasts, and primary rat cortical neurons. Finally, we have successfully combined the dry-patterned substrate with a microfluidic device. Patterned primary rat neurons were maintained for up to 6 days inside the microfluidic devices and the neurons' somas and processes were confined to the cell-adhesive region. The method developed in this work offers a convenient way of micropatterning biomaterials for selective attachment of cells on the substrates, and enables culturing of patterned cells inside microfluidic devices for a number of biological research applications where cells need to be exposed to well-controlled fluidic microenvironment.

Animals↗

Differentiation-on-a-chip: a microfluidic platform for long-term cell culture studies.

Here we demonstrate a microfluidic perfusion system suitable for a long-term (>2 week) culture of muscle cells spanning the whole process of differentiation from myoblasts to myotubes. Cell-adhesive surface microdomains alternating with a robust cell-repellent coating mimic in vivo spatial cues for muscle cell assembly and allow for confining the fusion of myoblasts into aligned, isolated multinucleated myotubes. The microfluidic system provides accurate control of the perfusion rates and biochemical composition of the environment surrounding the cells. Comparing muscle cell-specific differentiation markers and the timing of fusion, we observed no differences in differentiation between microfluidic and traditional cultures. All differentiation assays were fully microfluidic, i.e. they were performed by sequentially changing the fluids in the micro-channels. By delivering fluorescent markers using heterogeneous laminar flows, it was possible to confine a membrane receptor labeling assay to a region smaller than a myotube. Our method can serve as an improved in vitro model for studying muscle cell differentiation and for characterizing extracellular molecules and mechanisms involved in neuromuscular differentiation.

Animals↗

Microfluidic enzymatic-reactors for peptide mapping: strategy, characterization, and performance.

The design and characterization of two kinds of poly(dimethylsiloxane)(PDMS) microfluidic enzymatic-reactors along with their analytical utility coupled to MALDI TOF and ESI MS were reported. Microfluidic devices integrated with microchannel and stainless steel tubing (SST) was fabricated using a PDMS casting technique, and was used for the preparation of the enzymatic-reactor. The chemical modification was performed by introducing carboxyl groups to PDMS surface based on ultraviolet graft polymerization of acrylic acid. The covalent and physical immobilization of trypsin was carried out with the use of the activation reagents 1-ethyl-3-(3-dimethyl aminopropyl)carbodiimide(EDC)/N-hydroxysuccinimide (NHS) and a coupling reagent poly(diallyldimethylammonium chloride)(PDDA), respectively. The properties and success of processes of trypsin immobilization were investigated by measuring contact angle, infrared absorption by attenuated total reflection spectra, AFM imaging and electropherograms. An innovative feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by embedded SST electrode and replaceable tip. The lab-made devices provide an excellent extent of digestion of several model proteins even at the fast flow rate of 3.5 microL min(-1) for the EDC/NHS-made device and 0.8 microL min(-1) for the PDDA-made device, which afford very short residence times of 5 s and 20 s, respectively. In addition, the lab-made devices are less susceptive to memory effect and can be used for at least 50 runs in one week without noticeable loss of activity. Moreover, the degraded PDDA-made device can be regenerated by simple treatment of a HCl solution. These features are the most required for microfluidic devices used for protein analysis.

Dimethylpolysiloxanes↗

Highly sensitive signal detection of duplex dye-labelled DNA oligonucleotides in a PDMS microfluidic chip: confocal surface-enhanced Raman spectroscopic study.

Rapid and highly sensitive detection of duplex dye-labelled DNA sequences in a PDMS microfluidic channel was investigated using confocal surface enhanced Raman spectroscopy (SERS). This method does not need either an immobilization procedure or a PCR amplification procedure, which are essential for a DNA microarray chip. Furthermore, Raman peaks of each dye-labelled DNA can be easily resolved since they are much narrower than the corresponding broad fluorescence bands. To find the potential applicability of confocal SERS for sensitive bio-detection in a microfluidic channel, the mixture of two different dye-labelled (TAMRA and Cy3) sex determining Y genes, SRY and SPGY1, was adsorbed on silver colloids in the alligator teeth-shaped PDMS microfluidic channel and its SERS signals were measured under flowing conditions. Its major SERS peaks were observable down to the concentration of 10(-11) M. In the present study, we explore the feasibility of confocal SERS for the highly sensitive detection of duplex dye-labelled DNA oligonucleotides in a PDMS microfluidic chip.

Colloids↗

An electrochemically driven poly(dimethylsiloxane) microfluidic actuator: oxygen sensing and programmable flows and pH gradients.

We describe the fabrication and performance of an integrated microelectrochemical reactor-a design possessing utility for multiple applications that include electrochemical sensing, the generation and manipulation of in-channel microfluidic pH gradients, and fluid actuation and flow. The device architecture is based on a three-electrode electrochemical cell design that incorporates a Pt interdigitated array (IDA) working (WE), a Pt counter (CE), and Ag pseudo-reference (RE) electrodes within a microfluidic network in which the WE is fully immersed in a liquid electrolyte confined in the channels. The microchannels are made from a conventional poly(dimethylsiloxane)(PDMS) elastomer, which serves also as a thin gas-permeable membrane through which gaseous reactants in the external ambient environment are supplied to the working electrode by diffusion. Due to the high permeability of oxygen through PDMS, the microfluidic cell supports significantly (>order of magnitude) higher current densities in the oxygen reduction reaction (ORR) than those measured in conventional (quiescent) electrochemical cells for the same electrode areas. We demonstrate in this work that, when operated at constant potential under mass transport control, the device can be utilized as a membrane-covered oxygen sensor, the response of which can be tuned by varying the thickness of the PDMS membrane. Depending on the experimental conditions under which the electrochemical ORR is performed, the data establish that the device can be operated as both a programmable pH gradient generator and a microfluidic pump.

Diffusion↗

Rapid method for design and fabrication of passive micromixers in microfluidic devices using a direct-printing process.

We developed a facile and rapid one-step technique for design and fabrication of passive micromixers in microfluidic devices using a direct-printing process. A laser printing mechanism was dexterously adopted to pattern the microchannels with different gray levels using vector graphic software. With the present method, periodically ordered specific bas-relief microstructures can be easily fabricated on transparencies by a simple printing process. The size and shape of the resultant microstructures are determined by the gray level of the graphic software and the resolution of the laser printer. Patterns of specific bas-relief microstructures on the floor of a channel act as obstacles in the flow path for advection mixing, which can be used as efficient mixing elements. The mixing effect of the resultant micromixer in microfluidic devices was evaluated using CCD fluorescence spectroscopy. We found that the mixing performance depends strongly on the gray level values. Under optimal conditions, fast passive mixing with our periodic ordered patterns in microfluidic devices has been achieved at the very early stages of the laminar flow. In addition, fabrication of micromixers using the present versatile technique requires less than an hour. The present method is promising for fabrication of micromixers in microfluidic devices at low cost and without complicated devices and environment, providing a simple solution to mixing problems in the micro-total-analysis-systems field.

Biomedical Technology↗

Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA.

The Enzyme-Linked Immuno-Sorbent Assay, or ELISA, is commonly utilized to quantify small concentrations of specific proteins for a large variety of purposes, ranging from medical diagnosis to environmental analysis and food safety. However, this technique requires large volumes of costly reagents and long incubation periods. The use of microfluidics permits one to specifically address these drawbacks by decreasing both the volume and the distance of diffusion inside the micro-channels. Existing microfluidic systems are limited by the necessary control of extremely low flow rates to provide sufficient time for the molecules to interact with each other by diffusion only. In this paper, we describe a new microfluidic design for the realization of parallel ELISA in stop-flow conditions. Magnetic beads were used both as a solid phase to support the formation of the reactive immune complex and to achieve a magnetic mixing inside the channels. In order to test the detection procedure, the formation of the immune complex was performed off-chip before the reactive beads were injected into the reaction chamber. Anti-streptavidin antibodies were quantified with low picomolar sensitivity (0.1-6.7 pM), a linear range of 2 orders of magnitude and good reproducibility. This work represents the first step toward a new platform for simple, highly effective and parallel microfluidic ELISA.

Alkaline Phosphatase↗