PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Scanning Probe”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Assembling of dimeric entities of Cd(II) with 6-mercaptopurine to afford one-dimensional coordination polymers: synthesis and scanning probe microscopy characterization.

The direct reaction between 6-mercaptopurine (6-MP) and Cd(II) under different conditions yields either [Cd2(6-MP)4(NO3)2](NO3)2 (1) or [Cd(6-MP-)2.2H2O]n (4). Compound 1 behaves as the building block of the polymer [Cd(6-MP2-)2]n[Ca(H2O)6]n (3), by deprotonation of 6-MP ligand. In the reaction of 1 to give 3, the dinuclear compound [Cd2(6-MP)4(H2O)2](NO3)4.2H2O (2) can be isolated as an intermediate. Polymers 3 and 4 convert into each other in water via deprotonation-protonation reactions. The structures of compounds 1-3 have been determined by X-ray diffraction. Given the small differences in the arrangement shown in the crystal structures of the polymer 4 and the polyanion of 3, the stabilities and energetics of the two arrangements have been examined by DFT calculations to determine the possibility of identifying new conformations of both polymers. In addition, the two polymers have been characterized on surfaces by means of AFM. The direct reaction between 6-MP and Cd(II) and the deprotonation of the polymer 4 have proven to be useful routes for the isolation of one-dimensional systems on surfaces. The development of new strategies to characterize these types of polymers on surfaces opens the possibility to perform nanoscale studies on their properties and their potential use as nanomaterials.

Journal Article↗

Single polymer chains as specific transducers of molecular recognition in scanning probe microscopy.

A new approach for the specific detection and mapping of single molecule recognition is presented, based on the nonlinear elastic behavior of a single polymer chain. The process of molecular recognition between a ligand and a receptor is inherently accompanied by a decrease in the translational and rotational degrees of freedom of the two molecules. We show that a polymeric tether linked to the ligand can effectively transduce the configurational constraint imposed by molecular recognition into a measurable force, which is dominated by the entropic elasticity of the polymer. This force is specifically characterized by a strong nonlinearity when the extension of the polymer approaches its contour length. Thus, a polymer chain tethering the ligand to an oscillating cantilevered tip gives rise to a highly anharmonic motion upon ligand-receptor binding. Higher-harmonics atomic force microscopy allows us to detect this phenomenon in real time as a specific signature for the probing and mapping of single-molecule recognition.

Entropy↗

Two-photon photopolymerized tips for adhesion-free scanning-probe microscopy.

A hydrophobic polymeric tip of atomic force microscopy has been fabricated by two-photon adsorbed photopolymerization methods (TPAP). The fabrication was performed by a layer-by-layer polymerization of sliced multiple three-dimensional computer-aided design data. The used base resin was composed of acrylate and epoxy, which showed hydrophobic properties after the photopolymerization. For the sharp tip fabrication, we used a "dynamic partial polymerization method" which applied "the threshold effect" of TPAP to maximize the fabrication resolution. To investigate the performance of the fabricated polymeric tip, we have imaged several organic, inorganic, and biological samples using contact or dynamic force mode. The imaging results showed the hydrophobic polymeric tips solved various problems related to the tip adhesion to hydrophilic sample surfaces. Finally, the topographic image resolution of sub-5 nm was obtained using the polymeric tips for the hydrophilic mica surface.

Equipment Design↗

On-substrate lysis treatment combined with scanning probe microscopy revealed chromosome structures in eukaryotes and prokaryotes.

The proper function of the genome largely depends on the higher-order architecture of the chromosome. To understand the detailed chromosome structure in a native state, we developed an on-substrate procedure of subcellular fractionation suitable for the observation by atomic force microscopy (AFM). HeLa cells on a coverslip were successively treated with a detergent and a high-salt solution to remove the cytoplasmic and nucleoplasmic materials. A closer observation of the nucleus by AFM revealed that the interphase chromosome is composed of a granular unit of approximately 80 nm in diameter. Subsequent mild treatment with deoxyribonuclease I (10 U ml(-1)) exposed these units more clearly, which enabled us to uncover the 80-nm granules forming a fibre of approximately 80 nm width. In the cytoplasmic regions, cytoskeletal fibres with varying widths (10-70 nm) were observed. These observations suggest that the 80 nm granular fibre is a fundamental structural unit of the interphase chromosome. This on-substrate procedure was also applied to Escherichia coli. Cells attached on a coverslip were successively treated with lysozyme and detergent to partially release the nucleoid onto the substrate. The AFM observation revealed that the approximately 80 nm fundamental structural unit forms a granular fibre similar to that of HeLa cells. These results suggest that the fundamental mechanism of chromosome packing is common in both prokaryotes and eukaryotes.

Cell Nucleus Structures↗

A new DNA nanostructure, the G-wire, imaged by scanning probe microscopy.

G-DNA is a polymorphic family of quadruple helical nucleic acid structures containing guanine tetrad motifs [G-quartets; Williamson, J.R., Raghuraman, M.K. and Cech, T.R. (1989) Cell 59, 871-880; Williamson, J.R. (1993) Proc. Natl. Acad. Sci. USA 90, 3124-3124]. Guanine rich oligonucleotides that are self-complimentary, as found in many telomeric G-strand repeat sequences, form G-DNA in the presence of monovalent and/or divalent metal cations. In this report we use the atomic force microscope (AFM) to explore the structural characteristics of long, linear polymers formed by the telomeric oligonucleotide d(GGGGTTGGGG) in the presence of specific metal cations. In the AFM these polymers, termed G-wires, appear as filaments whose height and length are determined by the metal ions present during the self-assembly process. The highly ordered, controllable self-assembly of G-wires could provide a basis for developing advanced biomaterials.

Base Sequence↗

[New approaches to the study of viruses using scanning probe microscopy].

Atomic force microscopy was applied for studying individual virus particles. The micromechanism of rotaviruses was studied using the force curves of an atomic force microscope, with the Young's modulus of an individual particle being 1.0 x10(8) +/- 0.3 x 10(8) Pa. The distribution of the mechanical and adhesive properties over the sample surface was analyzed. The application of substrates modified by the corresponding antibodies made it possible to increase the self-descriptiveness of analysis. Some details of applying these substrates in studies of adenoviruses by atomic force microscopy are described. The approaches proposed enable one to extend the set of characteristics describing the virus particle.

Adenoviridae↗

[The new measurement technics in biology and medicine--atomic force microscopy].

Scanning probe microscopy (SPM) has recently become the most dynamically developing technique employed in research investigations. Atomic force microscopy (AFM) that uses a digitally-controlled scanner and a cantilever system with a measurement tip shaped as a cone with the apex radius of 2-50 nm and the application force of 10(-10) N, as well as a system of recording detectors, has allowed for identification of numerous biological structures in a nanometer scale. The paper presents a review of measurement methods that employ the atomic force microscopy and are being used in medicine and biology, along with major achievements accomplished owing to this technique by various investigators, including the authors themselves.

Animals↗

Quality assessment of atomic force microscopy probes by scanning electron microscopy: correlation of tip structure with rendered images.

While image quality from instruments such as electron microscopes, light microscopes, and confocal laser scanning microscopes is mostly influenced by the alignment of optical train components, the atomic force microscope differs in that image quality is highly dependent upon a consumable component, the scanning probe. Although many types of scanning probes are commercially available, specific configurations and styles are generally recommended for specific applications. For instance, in our area of interest, tapping mode imaging of biological constituents in fluid, double ended, oxide-sharpened pyramidal silicon nitride probes are most often employed. These cantilevers contain four differently sized probes; thick- and thin-legged 100 microm long and thick- and thin-legged 200 microm long, with only one probe used per cantilever. In a recent investigation [Taatjes et al. (1997) Cell Biol. Int. 21:715-726], we used the scanning electron microscope to modify the oxide-sharpened pyramidal probe by creating an electron beam deposited tip with a higher aspect ratio than unmodified tips. Placing the probes in the scanning electron microscope for modification prompted us to begin to examine the probes for defects both before and after use with the atomic force microscope. The most frequently encountered defect was a mis-centered probe, or a probe hanging off the end of the cantilever. If we had difficulty imaging with a probe, we would examine the probe in the scanning electron microscope to determine if any defects were present, or if the tip had become contaminated during scanning. Moreover, we observed that electron beam deposited tips were blunted by the act of scanning a hard specimen, such as colloidal gold with the atomic force microscope. We also present a mathematical geometric model for deducing the interaction between an electron beam deposited tip and either a spherical or elliptical specimen. Examination of probes in the scanning electron microscope may assist in interpreting images generated by the atomic force microscope.

DNA↗

Microscopy and single molecule detection in photosynthesis.

Progress in various fields of microscopy techniques brought up enormous possibilities to study the photosynthesis down to the level of individual pigment-protein complexes. The aim of this review is to present recent developments in the photosynthesis research obtained using such highly advanced techniques. Three areas of microscopy techniques covering optical microscopy, electron microscopy and scanning probe microscopy are reviewed. Whereas the electron microscopy and scanning probe microscopy are used in photosynthesis mainly for structural studies of photosynthetic pigment-protein complexes, the optical microscopy is used also for functional studies.

Crystallography↗

Functional tethered lipid bilayers.

Our strategy to provide the structural basis for the build-up of functional tethered membranes focuses on three approaches: the first one is based on the pre-organization of a monomolecular layer of a lipopolymer at the water/air interface which is then transferred to a solid support. Prior to deposition, the substrate is coated with a layer of benzophenone-derivatized silane molecules that allow for a stable covalent attachment by photo-cross-linking of some of the monomer units of the lipopolymer to the support. An alternative concept realizes a layer-by-layer deposition of the various structural elements: (1) the attachment layer with the reactive sites for the chemical stabilization; (2) a polymer 'cushion' prepared by adsorption and simultaneous or subsequent partial covalent binding to the reactive sites; and (3) a lipid monolayer transferred from the water/air interface, that contains a certain amount of lipids with reactive headgroups which, upon binding to the polymer tether, act as anchor lipids stabilizing the whole monolayer/cushion-composite. And finally, we build peptide-supported monolayers by first (self-) assembling amino acid sequences of various lengths via a SH-group near their N-terminus onto Au substances and use then their COO(-)-terminus to chemically attach phosphatidyl-ethanolamine lipids to form a stable monolayer of lipid-peptide conjugates. All the individual preparation steps and the various resulting (multi-) layers are characterized by surface plasmon spectroscopy, X-ray and neutron-reflectometry, contact angle measurements, IR spectroscopy, fluorescence microscopy, scanning probe microscopies, as well as, electrochemical techniques. For all tethering systems, the final membranes' architecture is obtained by fusing lipid vesicles onto the lipid monolayer. Proteins can be incorporated by either fusing vesicles that are loaded with the respective receptors, pores, or ion pumps via a reconstitution procedure, or via a transfer directly from a micellar solution to the pre-formed lipid bilayer at the solid support by a dialysis step. Two structural/dynamical features of tethered membranes which are considered to be of particular functional relevance, i.e. the degree of water uptake and, hence, the degree of swelling of the polymer support, as well as the lateral mobility of the lipid molecules in the membrane, are tested by surface plasmon optics and by measurements of the fluorescence recovery after photobleaching (FRAP), respectively. The results confirm that the presented preparation protocols yield fluid bilayers that mimic certain relevant properties of biological membranes. The functional characterization of tethered membranes, which is briefly summarized, is based on various electrochemical techniques, in particular, impedance spectroscopy, cyclic voltammetry, and chronoamperometric studies. The results obtained for reconstituted H(+)-ATPase from chloroplasts and E. coli and for cytochrome oxidase (with and without cytochrome c) confirm the incorporation of the proteins in an active form, thus, opening opportunities for novel sensor formats or offering a completely new model membrane system.

Biopolymers↗

Simple methods for the direct assembly, functionalization, and patterning of acid-terminated monolayers on Si111.

This article describes mild methods to directly assemble, functionalize, and pattern monolayers of undecylenic acid on hydrogen-terminated Si(111). These monolayers were assembled under very mild conditions from a neat solution of undecylenic acid containing 0.1 mol % 4-(decanoate)-2,2,6,6-tetramethylpiperidinooxy at room temperature without the need for UV light. Because of these mild conditions, monolayers exposing carboxylic acids could be assembled in one step without the need to protect the acid prior to its assembly. The monolayers were extensively characterized by horizontal attenuated total reflection infrared spectroscopy, X-ray photoelectron spectroscopy (XPS), and contact angle goniometry. The monolayers bonded to the silicon surface preferentially through the olefin with no detectable bonds between the carboxylic acids and silicon. The crystallinity of the monolayer was studied by infrared spectroscopy through the antisymmetric--v(a)(CH(2))--and symmetric--v(s)(CH(2))--stretches for methylene. Because it is important for future applications to assemble functional surfaces, methods to react the acid-terminated monolayers with trifluoroacetic anhydride and triethylamine to yield a symmetric anhydride on the monolayer were studied. These anhydrides were reacted with a variety of milligram-quantity amines to yield amide-terminated surfaces. This method was general, and a variety of amines could be bonded to the monolayer. The stabilities of these monolayers upon exposure to ambient conditions and under a variety of solvents were described. Because patterned monolayers have found wide applications, we have developed methods to pattern 1-octadecylamine and poly(ethylenimine) on the micrometer scale using soft lithography. In addition, polymer brushes of polynorbornene with thicknesses from 32 to 150 nm were grown from monolayers patterned with the Grubbs' catalyst. The patterned surfaces were imaged by scanning electron microscopy, scanning probe microscopy, and ellipsometry to determine the thicknesses of the patterns and the fidelity of the method.

Journal Article↗

Two-dimensional supramolecular self-assembly probed by scanning tunneling microscopy.

Supramolecular chemistry has a very large impact on chemistry of current interest and the use of non-covalent but directional forces is appealing for the construction of 'supramolecular architectures'. The invention of scanning probe microscopy techniques has opened new doorways to study these concepts on surfaces. This review deals with recent progress in the study of two-dimensional supramolecular self-assembly on surfaces probed by scanning tunneling microscopy, with a special emphasis on structure, dynamics and reactivity of hydrogen bonded systems.

Adsorption↗

Near-field scanning optical microscopy probes: a comparison of pulled and double-etched bent NSOM probes for fluorescence imaging of biological samples.

Bent near-field optical probes for biological applications have been fabricated using a combination of a two-step chemical etching method and focused ion beam milling to create a well-defined aperture. The transmission efficiencies have been evaluated as a function of laser wavelength (lambda) and aperture size (D) for both large and small core fibres. The probe transmission behaviour follows a (D/lambda)3 relationship. The double-etched probes are compared to pulled probes fabricated from highly GeO2-doped dispersion compensating fibre and a standard single-mode optical fibre. The transmission efficiencies of both types of pulled probes are approximately two orders of magnitude lower than double-etched probes with similar aperture sizes. To demonstrate the utility of the various probes, their imaging performance has been evaluated for samples of polymer beads and phase-separated phospholipid monolayers of dipalmitoylphosphatidylcholine or cholesterol/phosphatidylcholine/sphingomyelin mixtures. Both pulled and double-etched probes are suitable for fluorescence imaging of polymer spheres. However, pulled probes are rapidly damaged at the higher input laser intensities required for fluorescence imaging of monolayer samples doped with < 1% of a fluorescent dye-labelled lipid. The images obtained with the double-etched probes show excellent spatial resolution and signal/noise, illustrating the potential of such probes for imaging of biological samples.

Microscopy, Atomic Force↗

Imaging of DNA by scanning force microscopy.

The scanning probe microscopies applied to the sequencing of DNA is a challenging goal attempted by several groups. But one limitant parameter has been the sample preparation of DNA molecules. Here we report how to hold DNA molecules fixed on mica substrate and we show the three-dimensional configuration of double-stranded DNA obtained with our scanning force microscope. We can image DNA under negative supercoiling, a feature of general importance controlling the activities of DNA. We compared the electron micrographs of a carbon replica of the same DNA specimen with scanning force images which demonstrates well the feasibility and accuracy of our scanning probe measurements.

DNA↗