PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Preparation and characteristics of new coating for solid-phase microextraction.

Poly (methylphenylvinylsiloxane) (PMPVS) coating for solid-phase microextraction (SPME) was first prepared by using sol-gel approach and cross-linking of free radical initiation. The extraction properties of the novel coating for aromatic compounds were investigated using a self-made SPME device coupled with a gas chromatograph-flame ionization detector (GC-FID). The coating provided high surface areas and allowed high extraction efficiency. Compared with some commercial SPME stationary phases, the new phase showed better selectivity and sensitivity toward aromatic compounds. Furthermore, PMPVS coating showed good thermal stability and longer lifetime.

Biphenyl Compounds↗

Assay of stability, free and total concentration of chlorhexidine in saliva by solid phase microextraction.

This paper presents the development and application of a solid phase microextraction method for the full investigation of chlorhexidine interaction with saliva during a pharmacokinetic study: chemical stability, binding to proteins, free concentration, total concentration and kinetics of elimination after oral administration. Only 0.1 mL sample were needed for each time point and the concentration of salivary proteins was determined as well. It was shown that chlorhexidine remained stable in the oral cavity for at least 9 h and high concentrations of the drug (2 microg/mL total) were still present even 8 h after mouthrinsing. Supplementary facts were uncovered: while the total concentration followed first-order elimination kinetics, the free concentration remained almost constant for several hours; this showed that the oral cavity acted like a reservoir that slowly released the drug. It was also revealed that following oral administration of chlorhexidine, the normal composition of saliva changed for a few hours, probably as a physiological response to the bitter taste of the medicine. The method had a wide linear range (0.1-40 microg/mL free chlorhexidine) that was perfectly suitable for the study of chlorhexidine retention in the oral cavity. Separation and quantitation were achieved by liquid chromatography coupled to mass spectrometry; no interference from endogenous compounds was observed. This selective and sensitive solid-phase microextraction (SPME) approach for monitoring the free and total concentration of a drug, as well as the concentration of proteins that bind that drug, should prove to be more useful for pharmacokinetic studies than classic methods that only provide the total concentration as a final result.

Chlorhexidine↗

Determination of triazines in soil by microwave-assisted extraction followed by solid-phase microextraction and gas chromatography-mass spectrometry.

A method for determining triazine herbicides in soil samples that combines microwave-assisted extraction with solid-phase microextraction is described. Water containing 1% methanol was employed as extractant. The parameters of solid-phase microextraction and microwave-assisted extraction were investigated. In solid-phase microextraction, particular attention was paid to the negative effect of salt on fiber stability. Our experiments showed that this effect could be effectively reduced by simply washing the fiber with deionized water. The selected triazines could be efficiently extracted by the aqueous extractant at 105 degrees C for 3 min, with 80% output of maximum power (1,200 W). The extraction procedure provided good precision (<7%) and recoveries (76.1-87.2%). The limits of detection were in the range 2-4 microg/kg. Compared with conventional liquid extraction, microwave-assisted extraction-solid-phase microextraction was more efficient, accurate and faster, and used a very small amount of organic solvent (only 250 microL methanol). The extraction of aged spiked soil samples indicated that, although the recoveries were lower than those of freshly spiked samples, they were nevertheless satisfactory for the quantitative analysis of real-world samples.

Gas Chromatography-Mass Spectrometry↗

Comparative study of the whisky aroma profile based on headspace solid phase microextraction using different fibre coatings.

A dynamic headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled to ion trap mass spectrometry (GC-(IT)MS) method was developed and applied for the qualitative determination of the volatile compounds present in commercial whisky samples which alcoholic content was previously adjusted to 13% (v/v). Headspace SPME experimental conditions, such as fibre coating, extraction temperature and extraction time, were optimized in order to improve the extraction process. Five different SPME fibres were used in this study, namely, poly(dimethylsiloxane) (PDMS), poly(acrylate) (PA), Carboxen-poly(dimethylsiloxane) (CAR/PDMS), Carbowax-divinylbenzene (CW/DVB) and Carboxen-poly(dimethylsiloxane)-divinylbenzene (CAR/PDMS/DVB). The best results were obtained using a 75 microm CAR/PDMS fibre during headspace extraction at 40 degrees C with stirring at 750 rpm for 60 min, after saturating the samples with salt. The optimised methodology was then applied to investigate the volatile composition profile of three Scotch whisky samples--Black Label, Ballantines and Highland Clan. Approximately seventy volatile compounds were identified in the these samples, pertaining at several chemical groups, mainly fatty acids ethyl esters, higher alcohols, fatty acids, carbonyl compounds, monoterpenols, C13 norisoprenoids and some volatile phenols. The ethyl esters form an essential group of aroma components in whisky, to which they confer a pleasant aroma, with "fruity" odours. Qualitatively, the isoamyl acetate, with "banana" aroma, was the most interesting. Quantitatively, significant components are ethyl esters of caprilic, capric and lauric acids. The highest concentration of fatty acids, were observed for caprilic and capric acids. From the higher alcohols the fusel oils (3-methylbutan-1-ol and 2.phenyletanol) are the most important ones.

Alcoholic Beverages↗

Fibre selection based on an overall analytical feature comparison for the solid-phase microextraction of trihalomethanes from drinking water.

This paper describes the optimization of solid-phase microextraction (SPME) conditions for three different fibres (Carboxen-polydimethylsiloxane (CAR-PDMS), divinylbenzene-Carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB)) used to determine trihalomethanes (THMs) in water by headspace solid-phase microextraction and gas chromatography (HS-SPME-GC). The influence of temperature and salting-out effect was examined using a central composite design for each fibre. Extraction time was studied separately at the optimum values found for temperature and sodium chloride concentration (40 degrees C and 0.36g mL-1). The HS-SPME-GC-MS method for each fibre was characterised in terms of linearity, detection (LOD) and quantification (LOQ) limits and repeatability. The fibre PDMS-DVB was selected as it provided a broader linear range, better repeatability and lower detection and quantification limits than the others, particularly CAR-PDMS fibre. The accuracy of the proposed method using the PDMS-DVB fibre was checked by a recovery study in both ultrapure and tap water. A blank analysis study showed the absence of memory effects for this fibre. The reproducibility (expressed as a percentage of relative standard deviation) was 6-11% and the detection limits were between 0.078 and 0.52microgL-1 for bromoform and chloroform, respectively. Finally, the method was applied to determine THM concentration in two drinking water samples.

Gas Chromatography-Mass Spectrometry↗

Comparison of three different solid-phase microextraction fibres for analysis of essential oils in yacon (Smallanthus sonchifolius) leaves.

A headspace solid-phase microextraction (HS-SPME) procedure based on three commercialised fibers (100 microm polydimethylsiloxane, 65 microm polydimethylsiloxane-divinylbenzene and 50/30 microm divinylbenzene-Carboxen-polydimethylsiloxane) is presented for the determination of a selected essential oils in dried leaves of yacon (Smallanthus sonchifolius). The extraction performances of these compounds were compared using fibers with one, two and three coatings. The optimal experimental procedures for the adsorption and desorption of target compounds were determined. Significant parameters affecting sorption process such as sample weight, sorption and desorption time and temperature were optimised and discussed. Finally, the optimised procedures were applied successfully for the determination of these compounds in various yacon species. The relative concentration factors of three characteristic components of yacon were measured for relative evaluation of the fiber efficiency. Main essential oils were isolated from dried yacon leaves by appropriate solid-phase microextraction fiber and semi-quantitative analysis of the target volatiles was conducted by gas chromatography-flame ionisation detection (GC-FID) using a capillary column. Three compounds--beta-pinene, caryophylene and y-cadinene were found as the predominant essential oils. Its relative content was important for specification of yacon varieties. Solid-phase microextraction in combination with gas chromatography enabled a rapid and simple determination of relative content of essential oils in yacon.

Asteraceae↗

Solid phase microextraction for quantitative headspace sampling of apple volatiles.

Solid phase microextraction (SPME) was evaluated for use in the quantification of aroma volatile production by Granny Smith apples during cool storage. Particular attention was paid to quantifying alpha-farnesene (3,7,11-trimethyldodeca-1,3(E),6(E),10-tetraene) due to its involvement in superficial scald, a disorder of cool stored apples. Comparison between SPME and solid phase extraction (SPE) showed that the SPME fiber had greater adsorption of high molecular weight (MW) volatiles such as alpha-farnesene. When sampling by SPME, these higher MW volatiles did not equilibrate between apples, headspace, and fiber within sampling times as long as 90 min, while lower MW volatiles equilibrated within 5 min. This behavior was also shown by a simple model system consisting of five selected volatiles dissolved in an involatile, lipophilic liquid (squalane). The less volatile high MW aroma compounds evaporated slowly from the surface of the apples and were depleted from the headspace because of very rapid adsorption by the SPME fiber. The amount of alpha-farnesene adsorbed by the fiber increased with air movement through the system. In a static headspace system, the amount of alpha-farnesene adsorbed by the fiber decreased nonlinearly with increasing distance from the apples, due to adsorption onto the glass walls. While SPME is ideal for rapid, qualitative determination of apple headspace volatiles, the slower equilibration of higher MW volatiles limits its use for quantification in more complex systems.

Chromatography, Gas↗

Nitrogen isotope analysis of ammonium in aqueous solutions using a perfluorosulfonated ionomer membrane for solid-phase microextraction.

The use of custom-made solid-phase microextraction (SPME) fibers coated with a perfluorosulfonated ionomer, Nafion, was investigated for nitrogen isotopic analysis of ammonium in aqueous solutions. Aqueous ammonium was converted to ammonia by addition of a base, followed by absorption from the headspace, desorption in the injection port of a gas chromatograph, and analysis by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Fibers coated with a Nafion tubing were chosen due to a higher fiber-gas distribution constant and a higher Nafion thickness than fibers coated with Nafion solution, both leading to a higher amount of ammonia absorbed at equilibrium. The Nafion membrane-coated fiber absorbed approximately 20 times more than a commercial polydimethylsiloxane (PDMS) fiber. The isotopic fractionation between fiber and gas was 1.0117 +/- 0.0009 (standard deviation, SD, of all measurements) at an initial ammonia gas concentration of 21-210 microM. At 390 microM initial gas concentration it was slightly lower. When sampling from liquid samples, an ammonium concentration of 10 mM was needed to obtain a sufficient amount of ammonia absorbed. Modeling of the absorption at different temperatures showed that the absorption was approximately constant in the temperature range suitable for SPME experiments. Absorption at room temperature was therefore used for simplicity. A pilot study was conducted in which absorption was achieved from a single 9 microL droplet of sample. The preliminary results showed that delta(15)N analysis was possible for only 0.4-0.5 micromol of ammonium with a SD of 0.8 per thousand (n = 5).

Algorithms↗

Truffle aroma characterization by headspace solid-phase microextraction.

In the present study, a headspace solid-phase microextraction (HS-SPME) combined to gas chromatography-mass spectrometry (GC-MS) has been used to fully characterize aroma of truffles of different species. A fiber of medium polarity (for flavors) was used to avoid discrimination towards very non-polar and polar volatile compounds. In a previous work, extraction conditions were optimized by means of an experimental design leading to the following conditions that were used in the present study: extraction temperature, 53 degrees C; extraction time, 13.6 min; and equilibrium time, 5 min. A comparison among different truffles species has been established in terms of qualitative and quantitative differences on volatile composition. By using the optimal extraction conditions and GC-MS it was possible to identify 89 compounds in two different truffle species such as Tuber aestivum and Tuber melanosporum. An attempt has been made in order to be able to determine the influence of different geographical origins on the aroma fraction of such fungi.

Ascomycota↗

Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction.

In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.

Air↗

Determination of low-molecular mass aldehydes by automated headspace solid-phase microextraction with in-fibre derivatisation.

Headspace solid-phase microextraction (HS-SPME) analysis of low-molecular mass (C1-C10) aldehydes in aqueous solutions was investigated, using pentafluorophenylhydrazine (PFPH) and o-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) as in-fibre derivatisation reagents. Analysis of the derivatives was achieved, using GC-flame ionisation detection (FID). A comparison of the two reagents showed that PFBHA was superior to PFPH under the investigated conditions. Fundamental studies of the PFBHA and PFPH reactions showed that the kinetics of the process was limited by the mass transport rate of the analytes to the fibre. The developed PFBHA method gave detection limits in the low to sub-microgram per litre range for most of the aldehydes tested. The method was applied successfully to the analysis of particleboard, wine and fish samples.

Aldehydes↗

Simultaneous determination of sorbic and benzoic acids in food dressing by headspace solid-phase microextraction and gas chromatography.

A facile headspace solid-phase microextraction (HS-SPME) procedure using 85 microm polyacrylate (PA) fiber is presented for the simultaneous determination of preservatives (sorbic and benzoic acids) in food dressing, including Thousand Island Dressing, HellMANN'S Salad Dressing and Tomato Ketchup, by gas chromatography (GC) with flame ionization detector (FID). The method presented preserves the advantages typical of HS-SPME such as simplicity, low intensity of labor, low cost and solvent free. The main factors affecting the HS-SPME process, such as extraction temperature and time, desorption temperature and time, the acidity and salt concentration of the solution, were optimized. Limits of detection (LODs) of the method were 2.00 microg/L for sorbic acid and 1.22 microg/L for benzoic acid. Relative standard deviations (RSDs) for quintuplicate analyses at three concentration levels of 0.10, 2.0 and 20 mg/L ranged between 3.86 and 14.8%. The method also showed good linearity n a range from 0.02 to 40 mg/L with correlation coefficients (R2) of 0.9986 for sorbic acid and 0.9994 for benzoic acid. Recoveries for the two analytes in all the samples tested ranged from 83.44 to 113.2%. Practical applicability was demonstrated through the simultaneous determination of sorbic and benzoic acids in the three complex samples.

Benzoates↗

Determination of phthalates in water samples using polyaniline-based solid-phase microextraction coupled with gas chromatography.

A simple solid-phase microextraction (SPME) device, coupled with gas chromatography-flame ionization detection (GC-FID), was developed to detect trace levels of phthalates in environmental water samples. Polyaniline (PANI) was chosen as the sorbent for the SPME device and was electrochemically deposited on a stainless steel wire to achieve high thermal and mechanical stability. The porous structure of the PANI film, characterized by scanning electron microscopy (SEM), suggested large extraction capability. Key parameters were optimized and five phthalates were selected to evaluate the SPME-GC procedures. The method was also applied to the analysis of lake and river water samples. Control experiments were carried out using commercial polyacrylate (PA) fiber. The new PANI-SPME-GC method offers high accuracy, precision and sensitivity and low detection limits. Thus, the method developed could be used as a new way to monitor the trace levels of phthalates in water medium. A possible extraction mechanism was investigated using electrochemical impedance spectroscopy (EIS).

Acrylates↗

Mechanisms effecting analysis of volatile flavour components by solid-phase microextraction and gas chromatography.

Quantitative properties of solid-phase microextraction (SPME) have been studied in order to investigate a simple and reliable method for analysing volatile flavour components in strawberries. Monitoring the chemical composition profile of berries will be of interest for the producers in order to optimise growth and storage conditions. By the use of SPME and capillary gas chromatography selected standard components were quantified with accuracy within +/-7% and a linear response were found in all concentration ranges studied, covering three orders of magnitude. Equilibrium constants that describe how various components are distributed between the three phases present, sample, headspace and fibre coating were determined. In the system studied, the majority of analytes remained in the sample. This means that repeated analysis can be performed from a single sample without significantly changing the results. The mass transfers of the flavour components, from the sample and into the fibre, were fitted to a transport model assuming that the rate-controlling step is diffusion within the fibre. The experimental results agreed well with the model for most of the components studied. The response for three of the components (geraniol, linalool and trans-2-hexenyl butanoate) did not agree with the model. These components were present in the gas phase in only minute amounts explaining the deviation from the model. Such components will require a long absorption time (longer than 30 min). For quantitative analysis, it is important to use a very precise pre-determined absorption period and well defined sampling conditions. Internal standards can be omitted.

Chromatography, Gas↗

Analysis of aldehydes in water by solid-phase microextraction with on-fiber derivatization.

The solid-phase microextraction (SPME) technique with on-fiber derivatization was evaluated for the analysis of aldehydes in water. The poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber was used and O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) were first loaded onto the fiber. The aldehydes in water sample were agitated into headspace and extracted by SPME with on-fiber derivatization. Gas chromatography/mass spectrometry (GC/MS) was used for the analysis of oximes formed and the adsorption-time profiles were examined. The precision, recovery and method detection limits (MDLs) were evaluated with spiked bidistilled water, chlorinated tap water as well as well water. The relative standard deviations from different spiked water sample were all less than 10% and the recoveries were 100 +/- 15%. With 2 ml of water sample, MDLs were in the range of 0.12-0.34 microg/l. Compared with other techniques, the study shown here provided a simple, fast and reliable method for the analysis of aldehydes in water.

Aldehydes↗

Analysis of acidic pesticides using in situ derivatization with alkylchloroformate and solid-phase microextraction (SPME) for GC-MS.

A solid-phase microextraction (SPME) method was developed for the analysis of acidic pesticide residues in water. The method utilizes in situ derivatization with butylchloroformate (BuCF), followed by on-line SPME extraction using a PDMS fibre, and analysis by GC-MS. Derivatives of the phenoxy acids mechlorprop (MCPP), dichlorprop (DCPP), MCPA and 2,4-D and their phenol degradation products 4-chloro-2-methylphenol and 2,4-dichlorophenol (DCP) were identified. Detection limits at 0.16-2.3 microg/l were achieved. Optimization of derivatization, ion strength, extraction time, SPME-fibre, desorption time and temperature are described. Standard curves in the range 0.5-10.0 microg/l were fitted to a second-degree polynomial. Standard deviation (n = 5) was below 10% for the phenol derivatives, but 20-50% for the phenoxy acids. For method verification groundwater samples from a field experiment were screened for content of MCPP and compared to the results from the HPLC analysis. A good agreement was obtained with respect to identification of positive samples, even though concentrations measured by the SPME were lower than with HPLC. Even if the precision and accuracy do not meet the demands for a strictly quantitative analysis, the SPME method is suitable for screening, because it is cheap, it can be automated, and uses smaller amounts of potential harmful solvents. Also, the method is less labour-intensive, as it requires a minimum of sample preparation when compared to traditional analyses. The acidic pesticides bentazon, dicamba, bromoxynil, ioxynil, dinoseb and DNOC were included in the study but could not be analysed by the current method.

Acids↗

Identification of a pharmaceutical packaging off-odor using solid phase microextraction gas chromatography/mass spectrometry.

The use of a solid phase microextraction (SPME) sampling technique, in conjunction with gas chromatography/mass spectrometry (GC/MS) analysis, to identify an off-odor in a heat-stressed pharmaceutical packaging material is described. The ability of the commercially available polydimethylsiloxane (PDMS) coated microfiber to concentrate a trace volatile compound of interest enabled identification of the odor compound of interest. Despite being present at levels that defied detection using conventional headspace sampling techniques, ethyl-2-mercaptoacetate was determined to be the compound responsible for the offending odor. Formation of the thioester resulted from an unanticipated reaction (either esterification or transesterification) between a common residual solvent (ethanol), present in a commonly used pharmaceutical tablet dispersant, and low-level amounts of reactants or synthetic intermediates of an FDA-approved polyvinyl chloride (PVC)-resin thermal stabilizing agent.

Drug Packaging↗

Solid-phase microextraction for the analysis of human breath.

Solid-phase microextraction (SPME) has been applied to the quantitative determination of ethanol, acetone, and isoprene in human breath. The method involves extraction and preconcentration with a fused silica fiber coated with a polymeric stationary phase, desorption at 200 degrees C, and assay by gas chromatography/mass spectrometry. Three different fiber coatings have been evaluated with regard to sensitivity, linear range, precision, and detection limits. Typical RSD values in the range 2%-6% could be obtained, depending on the fiber coating and the compound investigated. The calibration curves for the compounds are reproducible and linear over the concentration ranges found in human breath samples. The method is capable of detecting concentrations of acetone and isoprene reported for healthy subjects. The influence of temperature and humidity on the extraction process has been studied in detail. A linear relationship between log K versus 1/T allows the calibration of the method for any given temperature. The device is portable, economical, and easy to use in patient sampling.

Acetone↗