PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Dentin”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Physical properties of the dentin-enamel junction region.

PURPOSE: To determine the physical properties between enamel and dentin at the dentin-enamel junction (DEJ) region of natural tooth structure. MATERIALS AND METHODS: Ultimate tensile cohesive strengths of the DEJ region of human and bovine teeth were measured using a microtensile test, and the nanohardness and Young's modulus from deep enamel to superficial dentin of human teeth were measured using a nanoindentation tester. RESULTS: The mean ultimate tensile cohesive strengths of bovine and human DEJ region were 47.7 MPa and 51.5 MPa, respectively. The nanohardness, dynamic hardness and Young's modulus of the DEJ region showed moderate values between those of enamel and dentin. Comparison of the cohesive strength of the human DEJ region with previous results of the bond strength of resin bonding systems indicate that current resin bonding systems might reproduce the biological adhesion of enamel to dentin in terms of the tensile strength. Moreover, the indentation properties of the DEJ region showed higher values than those of the underlying dentin or of resin impregnated dentin.

Acid Etching, Dental↗

Effect of multiple application of dentin bonding agent on marginal integrity of resin composite.

The purpose of the present study was to examine the effect of multiple application of dentin bonding agent to the adhesive surface on the marginal integrity of resin composite. The effect of multiple applications was evaluated by measuring the wall-to-wall polymerization contraction gap and by SEM observation. Multiple application of dentin bonding agent was found to prevent formation of the contraction gap. Although monomer penetration into the enlarged collagen network has been widely discussed as the possible mechanism of the dentin bonding agent and dentin primer, the true detailed mechanism of the dentinal bonding agent and dentin primer should be consistently explained by the prevention of monomer diffusion into the dentin and water contamination of the adhesive interface.

Acid Etching, Dental↗

Adhesion of resin composite core materials to dentin.

PURPOSE: This study determined (1) the effect of polymerization mode of resin composite core materials and dental adhesives on the bond strength to dentin, and (2) if dental adhesives perform as well to dentin etched with phosphoric acid as to dentin etched with self-etching primer. MATERIALS AND METHODS: Human third molars were sectioned 2 mm from the highest pulp horn and polished. Three core materials (Fluorocore [dual cured], Core Paste [self-cured], and Clearfil Photo Core [light cured]) and two adhesives (Prime & Bond NT Dual Cure and Clearfil SE Bond [light cured]) were bonded to dentin using two dentin etching conditions. After storage, specimens were debonded in microtension and bond strengths were calculated. Scanning electron micrographs of representative bonding interfaces were analyzed. RESULTS: Analysis showed differences among core materials, adhesives, and etching conditions. Among core materials, dual-cured Fluorocore had the highest bond strengths. There were incompatibilities between self-cured Core Paste and Prime & Bond NT in both etched (0 MPa) and nonetched (3.0 MPa) dentin. Among adhesives, in most cases Clearfil SE Bond had higher bond strengths than Prime & Bond NT and bond strengths were higher to self-etched than to phosphoric acid-etched dentin. Scanning electron micrographs did not show a relationship between resin tags and bond strengths. CONCLUSION: There were incompatibilities between a self-cured core material and a dual-cured adhesive. All other combinations of core materials and adhesives produced strong in vitro bond strengths both in the self-etched and phosphoric acid-etched conditions.

Acid Etching, Dental↗

Constancy of bond strength in 5 single-bottle dentin bonding systems.

OBJECTIVE: Historically, wide variations in the shear bond strength of resin composite bonded to dentin have been reported. The purpose of this study was to compare 5 commercially available single-bottle dentin bonding systems while controlling several sources of variation in shear bond strengths. METHOD AND MATERIALS: Extracted molars were stored for 2 weeks in 0.5% Chloramine T. The teeth were mounted, the occlusal enamel was removed to expose middle dentin, and the exposed dentin was etched and treated according to 1 of 6 protocols. Finally, a cylinder of resin-based composite was bonded to the dentin. After 24 hours, specimens were fractured under shear force, and the results were recorded in megapascals. RESULTS: The type of product used was significantly associated with the mean shear bond strength observed. All products exhibited some degree of variation from specimen to specimen. One product, PQ1, exhibited less variation than the other 4 products. CONCLUSION: PQ1 was found to have a significantly higher mean shear bond strength than the other 4 products tested. There was no significant difference between specimens bonded to dry dentin and specimens bonded to wet dentin when using PQ1.

Acetone↗

Effect of calcium removal on dentin bond strengths.

OBJECTIVE: The purpose of this in vitro study was to determine the microtensile bond strengths (mu TBS) of 3 dental adhesives when applied to dentin decalcified with ethylenediaminetetraacetic acid (EDTA). The null hypothesis tested was that the removal of calcium from dentin would not influence the bond strengths. METHOD AND MATERIALS: Eighteen extracted human molars were cut in 2 equal halves. One half served as the control, having no EDTA treatment, while the other half was assigned to 1 of 3 periods (1 hour, 24 hours, or 100 hours) of decalcification with buffered 0.5 mol/L EDTA. Middle dentin was bonded with 1 of 3 dentin adhesive groups: a self-etching primer, Clearfil SE Bond (SE); an acetone-based total-etch adhesive, Prime&Bond NT (NT); and an ethanol- and water-based total-etch adhesive, Single Bond (SB). The specimens were restored with Z-250 resin composite and sectioned in 0.9 +/- 0.2 mm2 sticks that were tested in tensile mode. RESULTS: For each adhesive, the control group (not decalcified) resulted in statistically higher bond strengths than the treatment groups. For specimens that were not decalcified, SE and SB had statistically similar bond strengths, but both resulted in statistically higher bond strengths than NT. For specimens decalcified for 1 hour, SE resulted in statistically higher bond strengths than either SB or NT, which were ranked in the same statistical group. SE was the only dentin adhesive to result in measurable mu TBS after decalcification with EDTA for 24 hours, while SB/24 hour and NT/24 hour specimens debonded spontaneously prior to testing. All the specimens treated with EDTA for 100 hours debonded prior to testing. CONCLUSION: Three conclusions were drawn: (1) All 3 adhesive systems included in this project bonded significantly better to calcified than to decalcified dentin, regardless of their composition; (2) The self-etching primer-based adhesive ranked consistently equal to or better than the 2 total-etch-based adhesives, regardless of the EDTA decalcification time; and (3) Removal of calcium may be more detrimental for adhesives that rely on dentin acid etching than for adhesives based on self-etching primers.

Acetone↗

Effect of three endodontic materials on the bond strength of two composite core materials to dentin.

PURPOSE: This study investigated the effect of dentin treatment with iodine potassium iodide, calcium hydroxide or a biphenol-A- diglycidylether epoxy resin sealer on the dentin bond strength of titanium-reinforced Bis-GMA and urethane dimethacrylate composite materials. MATERIALS AND METHODS: Dentin was exposed in four groups of extracted teeth (20 specimens each). Three groups were treated with one of the contaminants and the fourth group was left uncovered and served as the control group. All specimens were stored for 1 week at 37 degrees C and 100% humidity. The dentin surfaces were cleaned with pumice slurry using a prophylaxis rubber cup, rinsed and dried. Then the dentin surfaces were treated using the conditioner and the primer of the GLUMA adhesive system followed by placement of composite core materials. After 20 minutes, debonding of the core materials was accomplished using a shear-peel test. A two-way analysis of variance and Tukey's multiple range test was performed based upon core type and contaminant type (alpha = 0.05). RESULTS: Titanium-reinforced Bis-GMA composite showed significantly greater bond strength values than the urethane dimethacrylate composite material (p < 0.0001). The mean bond strength values in megapascals for the Bis-GMA resin ranged from 8.47 +/-1.52 for the calcium hydroxide group to 9.81 +/-0.94 for the control group. Mean bond strengths for the urethane dimethacrylate resin ranged from 3.35 +/-0.90 for calcium hydroxide to 3.99 +/-0.88 for iodine potassium iodide groups. Within each core group, no difference in bond strengths were noted compared to the uncontaminated control. CONCLUSION: Pretreatment of the dentin with iodine potassium iodide, calcium hydroxide, or epoxy resin followed by pumicing and using the GLUMA system conditioner and primer had no effect on the bond strength of the two resin composite core materials. However, the titanium reinforced Bis-GMA composite exhibited significantly greater bond strength to dentin than the urethane dimethacrylate based composite.

Analysis of Variance↗

Effect of water quality on the bonding of resin to moist dentin.

PURPOSE: To test the effect of different water samples, used for rinsing the dentin, following acid conditioning, on the bond strength of a resin-based composite (RBC) restorative material (Z100), to dentin using a one-bottle dentin adhesive (Single Bond). MATERIALS AND METHODS: In preliminary experiments two experimental shear bond strength methods were compared, and one was selected which was deemed to permit more uniform application of the adhesive and better light curing. In the definitive experiments there were five experimental groups, according to rinsing water used (1) distilled water as control, (2) water with 3.5 ppm iodine, (3) water 3.0 ppm sodium hypochlorite, (4) water with 2% ethanol, (5) water contaminated with 6 x 10(4) cfu/mL of E. coli BH5V. For each experimental group the shear bond strength to moist dentin from 10 human intact impacted third molars was measured. The dentin samples were etched, washed and gently blotted to leave the dentin moist. Following application of the adhesive and resin, specimens were stored at 37 degrees C for 24 hours prior to testing in an Instron testing machine at a rate of 0.5 mm/minute. RESULTS: Data (in MPa +/- standard deviation) were: Group 1: 21.2 +/- 4.1; Group 2: 20.8 +/- 5.6; Group 3: 21.8 +/- 6.2; Group 4: 22.9 +/- 5.9; Group 5: 19.6 +/- 5.5. These data support the null hypothesis that the water types used in this work had no significant effect on the bonding of a resin composite to dentin (P= 0.74, ANOVA).

Acid Etching, Dental↗

Effect of multiple application of a dentin adhesive on contraction gap width of a resin-based composite.

PURPOSE: To test the efficacy of the multiple application of a total-etch dentin adhesive was investigated by measuring (1) the contraction gap width of a light-activated resin-based composite in a cylindrical dentin cavity and (2) the early tensile bond strength to a flat dentin surface with the Single Bond Dental Adhesive System. MATERIALS AND METHODS: Contraction gap width was measured in a cylindrical dentin cavity (3 mm x 1.5 mm) treated with a single coat or double coats of the Single Bond adhesive and restored with Silux Plus or Z-100. As control, the cavity was treated with an experimental dentin bonding system consisting of EDTA, 35% GM and Clearfil Photo Bond. Early tensile bond strengths of Silux Plus or Z-100 were measured on the flat dentin surface treated with the three bonding procedures as in the contraction gap study within 10 min. after final cure. RESULTS: The contraction gap of Silux Plus and Z-100 was prevented with the double coats of the Single Bond adhesive, whereas the contraction gap of Z-100 was not prevented with the single coat of the Single Bond and the experimental system. When the film thickness of the Single Bond system was less than 2 microm, the gap could not be prevented. The tensile bond strengths of Silux Plus and Z-100 to flat dentin mediated with the three bonding procedures were not significantly different (P>0.05).

Acid Etching, Dental↗

[Studies on bonding interfaces of two dentin adhesives by scanning electron microscopy].

OBJECTIVE: To purpose of this study was to investigate the microstructure and bonding mechanism of bonding interfaces of two current one-bottle dentin bond systems(Prime & Bond NT, PBNT; Prime one Mirage, P-One). METHODS: Fifteen extracted, caries-free human molars were prepared according to a modified method used for microtensile bond strength measurement. Each crown was divided into nearly equal halves with a 5 mm deep slot for accepting treatment of the two dentin bond systems, respectively. After 24 h storage in distilled water at 37 degrees C, the bonded teeth were subjected to two treatments: 5 teeth were observed by and tested for microtensile bond strengths without further treatment and 10 teeth were thermocycled(2400 cycles, between 5 degrees C and 55 degrees C) prior to SEM observation and bond strength testing. Hour-glass shaped microspecimens with a thickness of approximately 0.5 mm were cut from each tooth and used for SEM observation and microtensile bond strength measurement. RESULTS: A typical resin-infiltrated zone (hybrid layer) with a thickness of 3-5 microns and well-formed cone shaped resin tags that penetrated the dentinal tubules were clearly observed at the resin-dentin interfaces in the two bond systems. There were multiple lateral branches of tubular resin tags that interconnected to form a micro-network of resin. No evident differences in SEM images between the two bond systems as well as between thermocycling and without thermocycling in each bond system were found. CONCLUSION: PBNT and P-One provided good resin infiltration, producing a three-dimensional interlocking micro-network of resin tags in the dentin tubules with multiple lateral branches that penetrate the intertubular dentin, which positively influenced the adhesion between dentin and the two bond systems.

Dental Bonding↗

[In-vitro research on the marginal adaptation of composites with the use of different dentin adhesives].

The aim of this investigation was the check and evaluation of 7 various dentin adhesives regarding their influence on the connection between dentin resp. enamel and composite filling. For that cylindrical cavities in dental crowns (enamel cavities) and roots (dentin cavities) were prepared and treated with dentin adhesives and composite materials. One part of the test teeth was subjected to loads storage in aqueous solution and thermocycling. The marginal adaptation of the composite filling was checked by means of the dye penetration test. The evaluation was made after cutting the teeth in the stereo microscope TECHNIVAL 2 (Carl Zeiss Jena) at 16-resp. 25 magnifications and defined criteria. The fillings in cavities bound by enamel exhibited a very good marginal adaptation of the composite. The location of the dentin cavity (crown or root dentin) had no significant influence on the fitting of the filling. A clear penetration of dye could be observed with the fillings in the dentin with and without adhesives, which considerably intensified after thermocycling. Best results with regard to the marginal adaptation were obtained with Scotchbond 2, Mirage-Bond and Cavex-Clearfil-Newbond. A restoration without a marginal gap was not possible.

Composite Resins↗

Permeability of root dentin to epinephrine released from gingival retraction cord.

The permeation of racemic epinephrine across roots of human molar crown segments was studied in vitro. Permeation was measured in the presence of cementum, with cementum removed (dentin exposed), and with and without dentin smear layers. Epinephrine was initially detected at 10 minutes and reached a steady state in 70 minutes. Epinephrine flux (the product of concentration and the flow rate per unit of dentin surface area) significantly increased when both the cementum and dentin smear layers were removed. The T1/2 (half-time in minutes necessary to reach steady-state diffusion) was zero with intact cementum and increased to approximately 40 minutes in dentin with and without smear layers. This study suggests that the permeation of epinephrine across root surfaces is prevented by the presence of cementum and retarded by the presence of dentin smear layers. Also, the data suggest that root dentin is another source of absorption when epinephrine-impregnated retraction cord is applied to the gingival sulcus.

Absorption↗

Adhesive permeability affects composite coupling to dentin treated with a self-etch adhesive.

Dentin bonded with one-step self-etch adhesives does not couple well to chemically-cured composites despite the presence of ternary catalysts in some systems. To determine whether additional factors are responsible for the poor coupling of dentin bonded with these adhesives, the authors used a one-step self-adhesive in which the ternary catalyst is incorporated separately in the brush applicator for activating the adhesive. The activated adhesive was bonded to dentin or prepolymerized composites. For microtensile bond strength evaluation, a dual-cured hybrid composite was used for coupling to the bonded substrates and activated using: (1) the light-cured mode (LC), (2) delayed light-activation (DL) and (3) the chemical-cured mode (CC). In addition, the composite polymerized in the CC mode was coupled to the two substrates bonded with (4) additional experimental adhesive versions without the ternary catalyst and (5) without the ternary catalyst and tertiary amine. Silver tracer penetration into bonded interfaces was examined using TEM by replacing the dual-cured composite with a light-cured or a chemically-cured microfilled composite. In the CC mode, the composites coupled poorly to both substrates bonded with the unactivated adhesive (5). The use of activated adhesives allowed for good coupling of the composites polymerized in all curing modes to bonded composite, but only in the LC mode to bonded dentin. Water-filled channels in the form of water trees and water blisters were present in the adhesive layer under all composite-curing modes in bonded dentin. These features were completely absent in the bonded composites, showing that the source of the water was from dentin. Water blisters were also observed along the adhesive-composite interfaces in bonded dentin when the coupling composites were polymerized using the CC or DL modes.

Adhesives↗

Microtensile bond strength of tooth-colored materials to primary tooth dentin.

PURPOSE: This study measured the microtensile bond strengths of 2 tooth-colored restorative materials with and without conditioning of primary teeth dentin, and examined the micromorphology of the debonded surfaces and material-dentin interfaces. METHODS: Cylindrical specimens of packable composite resin (PCR) and resin-modified glass ionomer cement (RMGIC) bonded to dentin of primary teeth were ground to an hourglass shape and tested for microtensile bond strength. The debonded surfaces and material-dentin interfaces were prepared and examined under a scanning electron microscope (SEM). RESULTS: The microtensile bond strength values (mean +/- SD, in MPa) of PCR (Filtek P60 with Single Bond) and RMGIC (Fuji II LC), with or without the application of Cavity Conditioner (14.8 +/- 5.36, 12.01 +/- 4.43, 11.94 +/- 4.60, respectively), did not differ significantly (P > .05). Partial adhesive and partial cohesive failures within the restorative material predominated. The distributions of failure modes did not differ significantly between groups (P > .05). Under SEM, each material was seen to be closely adapted to dentin. Dentinal tubules were enlarged with etching, and the depth of penetration of resin tags of PCR was greater than for RMGIC. Smear plugs were incompletely removed by cavity conditioning. CONCLUSIONS: The bond strength of the PCR, Filtek P60 with Single Bond, to dentin of primary teeth was comparable to that of the RMGIC, Fuji II LC. Conditioning of the cavity preparation with Cavity Conditioner did not improve the bond strength of Fuji II LC. The distribution of failure modes did not differ between materials.

Acid Etching, Dental↗

Preliminary studies on pulp capping with demineralized dentin.

The use of osteoinductive demineralized dentin matrix in the repair of vital pulp exposures was examined. The pulps of the maxillary first molars of adult male Long Evans rats were exposed and capped with either demineralized dentin particles or guanidinium extracted demineralized dentin particles; then covered with a glass ionomer cement restoration. The animals were sacrificed after two weeks and the maxillae were dissected free, fixed in formaldehyde and demineralized. Histologic examination revealed that in those cases where the protective glass ionomer restoration was intact, both groups showed some healing. There was some preliminary indication that the extent of reactive matrix formation was greater in the osteoinductive group. In both groups, odontoblast-like cells appeared to incorporate some of the dentin particles into the reparative dentin bridge. This preliminary work suggests that osteoinductive factors present in demineralized incisor dentin might be used to guide the formation of a dentin bridge in a rat model for vital pulp exposures.

Animals↗

Glutaraldehyde in bonding systems disinfects dentin in vitro.

PURPOSE: To study the dentin disinfecting capacity of glutaraldehyde-containing bonding agents. MATERIALS AND METHODS: Uniformly sized bovine dentin blocks infected with Enterococcus faecalis ATCC 29212 were treated according to manufacturer's instructions with a three-step bonding system (Syntac Classic), its single components, or Gluma Primer. Bacterial growth from dentinal filings obtained immediately after application of the bonding agents was assessed at different dentin depths. Minimal inhibitory concentration and minimal bactericidal concentration of glutaraldehyde against E. faecalis were determined. RESULTS: Both Gluma Primer and Syntac Adhesive disinfected dentin, while the other components failed to do so. This was explained by the high antibacterial efficacy of glutaraldehyde even at low concentrations. Applied in consecutive order, the Syntac bonding system disinfected dentin blocks equally well with or without previous application of Gluma Primer. CONCLUSION: Under the conditions of the current study, bonding agents containing glutaraldehyde appear to be good dentin disinfectants compatible with bonding systems. However, their effect on pulp tissue awaits further clarification.

Animals↗

Phosphoric acid as a dentin etchant.

This study determined the effect of phosphoric acid (H3PO4) application to dentin on the shear bond strength (SBS) and microleakage of an experimental bonding system. Thirty human maxillary permanent first and second molars were used for the SBS evaluation. In 15 of the teeth the Dentin Conditioner was applied to dentin for 30 seconds (A), while in the remaining 15 teeth the smear layer was removed by the application of a 37% H3PO4 gel for 20 seconds (B). The Primers 1 and 2 were mixed and applied to the conditioned dentin followed by the application of the Dentin Bonding Resin prior to the placement in three increments of the Bisfil-M composite. The specimens were stored in physiological saline at 37 degrees C for 24 hours prior to applying a shear load at a crosshead speed of 0.5 mm. inch-1 in an Instron machine. Shear bond strengths were expressed in MPa. Circular Class V preparations were made on the roots of 30 maxillary permanent canines, 15 restored using the Dentin Conditioner (C) and 15 by removing the smear layer with the H3PO4 gel (D). Microleakage of the restorations was determined quantitatively by means of a spectrophotometric method. The quantitative microleakage was expressed as microgram dye/restoration. The data were analyzed by the Student t-test. The following results were obtained: A: 14.2 +/- 2.2 MPa; B: 7.2 +/- 4.2 MPa; C: 30.0 +/- 28.6 micrograms dye/restoration; (D) 10.3 +/- 8.2 micrograms dye/restoration. Removing the smear layer with H3PO4 reduced the SBS to dentin but decreased the quantitative microleakage significantly.

Acid Etching, Dental↗

Effect of bur-cut dentin on bond strength using two all-in-one and one two-step adhesive systems.

PURPOSE: To compare the microtensile bond strength (MTBS) of two all-in-one adhesive systems and one experimental two-step self-etching adhesive system to two types of bur-cut dentin. MATERIALS AND METHODS: Using one of the three adhesives, Xeno CF Bond (Xeno), Prompt L-Pop (PL), or the experimental two-step system ABF (ABF), resin composite was bonded to flat buccal and root dentin surfaces of eight extracted human premolars. These surfaces were produced using either regular-grit or superfine-grit diamond burs. After storage overnight in 37 degrees C water, the bonded specimens were sectioned into six or seven slices approximately 0.7 mm thick perpendicular to the bonded surface. They were then subjected to microtensile testing. The surfaces of the fractured specimens were observed microscopically to determine the failure mode. In addition, to observe the effect of conditioning, the two types of bur-cut dentin surfaces were conditioned with the adhesives, rinsed with acetone, and observed with SEM. RESULTS: When Xeno and PL were bonded to dentin cut with a regular-grit diamond bur, MTBS values were lower than to superfine bur-cut dentin, and failures occurred adhesively at the interface, whereas the experimental two-step adhesive showed no significant difference in microtensile bond strength between two differently cut surfaces. CONCLUSION: The all-in-one adhesives tested here improved bond strengths when bonded to superfine bur-cut dentin as a substrate, whereas the experimental two-step adhesive system showed unchanged bonding to both regular and superfine bur-cut dentin surfaces.

Acetone↗

Effects of diamond bur particle size on dentin bond strength.

PURPOSE: To evaluate the influence of particle size of originally designed diamond burs on resin adhesion to sound young human permanent dentin. METHODS: The buccal surfaces of 105 premolars were used. Six test groups were prepared. The adhesive systems and resin-based composites used for Groups 1-3 were Clearfil SE Bond (SE) and Clearfil AP-X, and for Groups 4-6, Single Bond (SB) and Z250. Flat dentin surfaces were finely ground with 25 microm particle size IW-G5 diamond bur (IW-G5, Groups 1 and 4), 50 microm particle size IW-G4 diamond bur (IW-G4, Groups 2 and 5), or 600-grit SiC paper (#600, Groups 3 and 6). The microstructure of the prepared dentin, SE primed or SB etched dentin, and resin-dentin interfaces of each group (3 teeth/group) were studied using SEM. Shear bond strengths (SBS) in MPa were tested (10 teeth/group), and the failed surfaces were observed using SEM. Data was statistically analyzed using ANOVA and Fisher's PLSD at P < 0.05. RESULTS: The dentin ground with the IW-G5 or IW-G4 bur was rougher than the dentin ground with the 600-grit SiC paper. The mean SBS (MPa) for Groups 1-6 were: 32.3 +/- 5.0, 27.6 +/- 6.4, 21.3 +/- 3.6, 5.9 +/- 2.9, 6.5 +/- 3.1 and 5.3 +/- 2.0. The SBS of Groups 1-3 (SE groups) were significantly higher than those of Groups 4-6 (SB groups). The SBS of Group 1 (IW-G5, SE group) was significantly higher than those of Groups 2 (IW-G4, SE group) and 3 (#600, SE group), and the SBS of Group 2 was significantly higher than that of Group 3. There was no significant difference for SBS among Groups 4, 5 and 6. Fracture mode after SBS test mainly showed mixed fracture (adhesive and cohesive resin fracture) for the SE groups, and adhesive fracture for the SB groups.

Analysis of Variance↗