PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65Linked to original sources

Bone material elasticity in a murine model of osteogenesis imperfecta.

To investigate the source of bone brittleness in the disease osteogenesis imperfecta (OI), biomechanical properties have been measured in the femurs from a homozygous (oim/oim) mutant mouse model of OI, its heterozygous littermates, and wild-type animals. The novel technique of ultrasound critical-angle reflectometry (UCR) was used to determine bone material elasticity matrix from measurements of the pressure and shear wave velocity at different orientations about selected points of the bone specimens. This nondestructive method is the only available means for obtaining measurements of this nature from a single surface. The ultrasound pressure wave velocity showed an increased isotropy in the homozygous compared to the wild-type specimens. This was reflected in a significant decrease in the principal elastic modulus measured along the length of the oim/oim bones (E33) while the modulus along the width (E11) did not change significantly, compared to wild-type specimens. The Poisson's ratio, v12, also had a significantly increased value in oim/oim bones. Measurements of these parameters in heterozygous animals generally fell between those from homozygous and control mice. The differences in the elasticity components in oim/oim bones indicate an altered stress distribution and a modified elastic response to loads, compared to normal bone.

Animals↗

Electrospinning polydioxanone for biomedical applications.

Polydioxanone (PDS) is a colorless, crystalline, bioabsorbable polymer that was first developed specifically for wound closure sutures. The compatibility, degradation rate, and mechanical properties (including shape memory) of PDS are of interest when considering the design of tissue engineering scaffolds. This research presents the electrospinning of PDS to fabricate unique nanofibrous structures for a variety of biomedical applications. Electrospinning is a polymer processing technique that utilizes an electric field to form fibers from a polymer solution or melt and allows the fabrication of nanofibrous non-woven structures. Results demonstrate the ability to control the fiber diameter of PDS as a function of solution concentrations and the fiber orientation with our prototype electrospinning apparatus. The results also show dependence between the fiber orientation and the elastic modulus, peak stress, and strain to failure of PDS in a uniaxial model.

Biocompatible Materials↗

Elastic contributions dominate the viscoelastic properties of sputum from cystic fibrosis patients.

Sputum samples from cystic fibrosis (CF) patients were investigated by oscillatory, creep and steady shear rheological techniques over a range of time scales from 10(-3) to 10(6) s. The viscoelastic changes obtained by mixing sputa with the actin-filament-severing protein gelsolin and with the thiol-reducing agent dithiothreitol (DTT) were also investigated. At small strains sputum behaves like a viscoelastic solid rather than a liquid. A nearly constant steady shear viscosity at low shear rates is only observed after long shearing times which cause irreversible changes in the samples. Creep-recovery tests confirm that sputa exhibit viscoelastic properties, with a significant elastic recovery. The results suggest that measurements of elastic moduli, rather than viscosities are more closely related to the mechanical properties of sputum in situ. Severing of actin filaments lowers the elastic modulus by 30-40%, but maintains viscoelastic integrity, while reduction of thiols in the glycoproteins nearly completely fluidizes the samples.

Cystic Fibrosis↗

Biomechanical properties of tendons during lower-leg lengthening in dogs using the Ilizarov method.

Ten dogs were provided with a circular fixator. Segment resection of the fibula and tibial osteotomy in the right lower leg was performed. 5 days after surgery, a lengthening of the right lower leg by 2.5 cm was performed on 6 dogs using a distraction rate of 0.5 mm, twice per day. 3 dogs with leg lengthening and 2 dogs of the control group without leg lengthening were sacrificed at the end of the distraction phase of 25 days and the remaining dogs after another 25 days. Postmortally the tendons of the tibialis anterior, extensor digitorum longus, peroneus longus and the achilles tendon were taken from the operated right side and the left non-operated control side and were examined biomechanically in cyclic tests. The control group without lengthening showed no changes in the biomechanical properties in the tendons of either side nor in those of the unlengthened left side of the operated dogs. In contrast the biomechanical tests revealed a marked decrease of the elastic modulus, an increase of distraction length and an increase of modulus reduction on the lengthened side compared to the non-operated left side.

Animals↗

Cutaneous extensibility in health and disease.

The results are recorded of a number of studies performed over the last few years using a simple and reproducible method for investigating the extensibility of intact skin. A major advantage of this method lies in the fact that it causes the patient no discomfort and leaves his skin without blemish. We have found abnormal behaviour of skin in response to applied stress in the heritable connective tissue disorders: Ehlers-Danlos Syndrome, cutis laxa, and pseudoxanthoma elasticum, and in the acquired disorders of acromegaly, hypopituitarism and scleroderma. An abnormal elastic modulus, however, was found only in pseudoxanthoma elasticum and the growth-hormone disorders.

Acromegaly↗

Neurotransmission and viscoelasticity in the ovine fetal bladder after in utero bladder outflow obstruction.

Fetal bladder outflow obstruction, predominantly caused by posterior urethral valves, results in significant urinary tract pathology; these lesions are the commonest cause of end-stage renal failure in children, and up to 50% continue to suffer from persistent postnatal bladder dysfunction. To investigate the physiological development of the fetal bladder and the response to urinary flow impairment, we performed partial urethral obstruction and complete urachal ligation in the midgestation fetal sheep for 30 days. By electrical and pharmacological stimulation of bladder strips, we found that muscarinic, purinergic, and nitrergic mechanisms exist in the developing fetal bladder at this gestation. After bladder outflow obstruction, the fetal bladder became hypocontractile, producing less force after nerve-mediated and muscarinic stimulation with suggested denervation, and also exhibited greater atropine resistance. Furthermore, fetal bladder urothelium exerted a negative inotropic effect, partly nitric oxide mediated, that was not present after obstruction. Increased compliance, reduced elasticity, and viscoelasticity were observed in the obstructed fetal bladder, but the proportion of work performed by the elastic component (a physical parameter of extracellular matrix) remained the same. In addition to denervation, hypocontractility may result from a reduction in the elastic modulus that may prevent any extramuscular components from sustaining force produced by detrusor smooth muscle.

Adenosine↗

Fatigue properties of acrylic denture base resins.

Observations were made of fractured surfaces caused by flexural and tensile fatigue tests made in polymethyl methacrylate denture base resins (PMMA). In addition, the changes in dynamic viscoelastic and tensile properties of the materials along with fatigue propagation were investigated. In the tensile and flexural fatigue tests, both the fractured surfaces, which had striations on their surfaces and cracks near the fractured section, closely resembled each other in appearance. On the other hand, all of the tensile properties, such as elastic modulus, toughness and tensile strength, decreased with the increase of the number of stress cycles in the fatigue test. The storage modulus (E') of the material decreased gradually along with fatigue propagation over the whole range of temperatures tested. The loss modulus (E") and mechanical loss tangent (tan delta) increased slightly. The fatigue limit of four commercial denture base resins varied widely from one product to another.

Dental Stress Analysis↗

Effect of admixed high-density polyethylene (HDPE) spheres on contraction stress and properties of experimental composites.

Additives that provide stress relief may be incorporated into dental composites to reduce contraction stress (CS). This study attempted to test the hypothesis that conventional fillers could be replaced by high-density polyethylene (HDPE) spheres in hybrid and nanofill composites to reduce CS, but with minimal effect on mechanical properties. Nanofill and hybrid composites were made from a Bis-GMA/TEGDMA resin having either all silica nanofiller or 75 wt.% strontium glass + 5 wt.% silica and replacing some of the nanofiller or the glass with 0%, 5% (hybrid only), 10% or 20 wt.% HDPE. The surface of the HDPE was either left untreated or had a reactive gas surface treatment (RGST). Contraction stress (CS) was monitored for 10 min in a tensilometer (n = 5) after light curing for 60 s at 390 mW/cm(2). Other specimens (n = 5) were light cured 40 s from two sides in a light-curing unit and aged 1 d in water before testing fracture toughness (K(Ic)), flexure strength (FS), and modulus (E). Results were analyzed by ANOVA with Tukey's multiple comparison test at p < 0.05. There was no difference between composites with RGST and untreated HDPE except for FS-10% HDPE hybrid (RGST higher). An increased level of HDPE reduced contraction stress for both types of composites. Flexure strength, modulus (hybrid only), and fracture toughness were also reduced as the concentration of HDPE increased. SEM showed evidence for HDPE debonding and plastic deformation during fracture of the hybrid composites. In conclusion, the addition of HDPE spheres reduces contraction stress in composites, either through stress relief or a reduction in elastic modulus.

Biomechanical Phenomena↗

Imaging soft samples with the atomic force microscope: gelatin in water and propanol.

We have imaged mica coated with thin gelatin films in water, propanol, and mixtures of these two liquids by atomic force microscopy (AFM). The elastic modulus (Young's modulus) can be tuned from 20 kPa to more than 0.1 GPa depending on the ratio of propanol to water. The resolution is best in pure propanol, on the order of 20 nm, and becomes worse for the softer samples. The degradation in resolution can be understood by considering the elastic indentation of the gelatin caused by the AFM tip. This indentation becomes larger and thus the contact area becomes larger the softer the sample is. Therefore this study may be used to estimate the resolution to be expected with an AFM on other soft samples, such as cells. Nondestructive imaging was possible only by imaging at forces < 1 nN. This was difficult to achieve in contact mode because of drift in the zero load deflection of the cantilever, supposedly caused by temperature drift, but straightforward in tapping mode.

1-Propanol↗

Evaluation of the adjoint equation based algorithm for elasticity imaging.

Recently a new adjoint equation based iterative method was proposed for evaluating the spatial distribution of the elastic modulus of tissue based on the knowledge of its displacement field under a deformation. In this method the original problem was reformulated as a minimization problem, and a gradient-based optimization algorithm was used to solve it. Significant computational savings were realized by utilizing the solution of the adjoint elasticity equations in calculating the gradient. In this paper, we examine the performance of this method with regard to measures which we believe will impact its eventual clinical use. In particular, we evaluate its abilities to (1) resolve geometrically the complex regions of elevated stiffness; (2) to handle noise levels inherent in typical instrumentation; and (3) to generate three-dimensional elasticity images. For our tests we utilize both synthetic and experimental displacement data, and consider both qualitative and quantitative measures of performance. We conclude that the method is robust and accurate, and a good candidate for clinical application because of its computational speed and efficiency.

Algorithms↗

Vitreous cryopreservation maintains the viscoelastic property of human vascular grafts.

Assess the effects of cryopreservation (cryo) and vitrification (vitro) on the viscoelastic properties of blood vessels. Human external Iliac artery vessels were harvested from liver organ donors (n=8). In each case the vessel was segmented into 3 equal parts, which were randomly placed in one of 3 categories: Fresh (stored in 4 degrees C UW for 6 h), Cryo (Placed in 10% Dulbecco's modified Eagle medium (DMEM) and slowly frozen to -196 degrees C), or Vitro (Placed in 40% DMEM and rapidly cooled to -196 degrees C). A pulsatile flow circuit was used to perfuse arterial segments at physiological pulse pressure and flow. Intraluminal pressure was measured using a Millar Mikro-tip catheter transducer, and vessel wall motion was determined with duplex ultrasonography coupled with a novel echo-locked vessel wall tracking system. Diametrical compliance (DC), Petersons elastic modulus (Ep), and stiffness index (beta) were then calculated for each of the three groups over 3 mean pressure ranging from 40 to 80 mmHg. The change in the viscous component of arterial wall (lag phase angle, theta) was calculated from hysteresis plots. No significant changes were observed in the elastic properties of fresh and vitrified vessels (P>0.05 for each of DC, Ep, and beta). Similarly, variation in the wall viscosity between fresh and vitrified vessels appeared to be nonsignificant (theta=12.60+/-4.04 vs. 17.60+/-1.14, respectively). In contrast, statistical analysis of results obtained for cryopreserved vessels to the fresh vessels showed significant reduction in elastic parameter values. There was also a significant increase in the phase angle theta of the cryopreserved vessels (theta=24.30+/-6.32; P<0.001) compared with fresh vessel. Results suggest that vitrification maintains both elastic and viscous components of the mechanical properties of vascular grafts, which is positively correlated with their functional patency. In contrast, damage caused during cryopreservation significantly affects the overall tensile strength and elasticity of the vessel (i.e., Ep and beta), the dynamic properties (DC), and appears to significantly affect the viscous component of the vessel wall (theta), which is likely reduce the patency of the graft for transplantation purposes.

Cryopreservation↗

Low-frequency viscoelastic properties of canine femoral artery in vivo.

Mechanical properties of the canine femoral artery in vivo are measured as a function of frequency (0.0025--0.1 Hz) and as a function of mean pressure (10--16 kPa). Sinusoidal pressure variations are generated with a servo-controlled occluder system. The absolute value of the Young's modulus increases with mean pressure (E = 0.63 X 10(5) exp(0.211P)-N.m-2) at 0.05 Hz; where P is pressure. At heart rate frequencies (average value 2.22 Hz) this relation is: E = 1.25 X 10(5) exp(0.175P) N.m-2. The phase angle of the Young's modulus is independent of pressure at both frequencies. At 0.05 Hz we found: phi = 0.189 - 0.00788 P radians and at 2.22 Hz: phi = 0.0723 + 0.000428 P. The slope of both lines is not significantly different from zero slope (alpha = 0.05). Frequency dependence is studied at a constant pressure level (Pr, average value 14.3 kPa) just below the animals' mean pressure levels (average value 15.9 kPa). The frequency behavior of the elastic modulus is fitted with a function with two poles and two zeros (poles at 0.003 and 0.038 Hz; zeros at 0.0022 and 0.03 Hz).

Animals↗

Visualizing tissue compliance with MR imaging.

We propose a method for visualizing the mechanical properties of tissue based on the use of periodic mechanical compression in conjunction with phase-contrast MR imaging. A specialized mechanical transducer was used to provide programmable compression pulses to the surface of compliant phantoms. These compression pulses were synchronized to a spin-echo sequence with motion-sensitizing gradients to generate phase information reflecting spin displacement throughout the phantom. This sequence was tested with two agarose gel phantoms. The first was a cylinder containing three parallel layers of varying compliance and the second was composed of a semirigid sphere suspended in a uniform layer of decreased elastic modulus. Images showed complex patterns of motion throughout the phantom, which correlated with expected motion behavior of the phantom structures. This indicates that the biomechanical properties of tissues may be elucidated through the use of motion-sensitized MR imaging and suggests that a form of image contrast relating to tissue elasticity may be feasible.

Compliance↗

Accelerating MR elastography: a multiecho phase-contrast gradient-echo sequence.

PURPOSE: To demonstrate the feasibility of using a multiecho phase-contrast (PC) gradient-echo sequence with motion-sensitizing gradient (MSG) to accelerate MR elastography (MRE) acquisitions in comparison to single-echo PC sequences. MATERIALS AND METHODS: The sequence was implemented and compared with a conventional single-echo sequence as the standard of reference in both agarose phantoms and in vivo in the biceps of three healthy volunteers. For reconstruction of the elasticity modulus, a local frequency estimation (LFE) algorithm was used. ETL factors of 1-16 were evaluated. RESULTS: Phantom experiments demonstrated excellent consistency between single-echo and multiecho measurements in terms of wave equivalency, SNR, and reconstructed shear modulus. Additionally, the in vivo MRE examinations showed an excellent correspondence to the single-echo results. Minor loss of wave amplitude was observed at higher ETL factors. CONCLUSION: The results demonstrate that a multiecho sequence is suitable for accelerating MRE in nearly homogeneous tissue, such as muscle. It provides equivalent elasticity values in a significantly reduced scan time compared to a single-echo sequence. The maximum achievable ETL factor must be individually determined for the target tissue.

Acceleration↗

Devices for use as an artificial articular surface in joint prostheses or in the repair of osteochondral defects.

The covering of ultra high molecular weight polyethylene (UHMWPE) and calcium hydroxyapatite (HA)/tricalcium phosphate (TCP) porous solid substrate with polyHEMA hydrogel has been studied aiming at the development of devices to be used as artificial articular surfaces in joint prosthesis or osteochondral repair grafts. Commercial porous UHMWPE was used. Ceramic porous substrate was prepared by load compaction of an HA and TCP powder mixture obtained by aqueous precipitation technique. Two different compaction loads and grain size distribution was used. Polymer particles were added to the powder mixture in order to increase the substrate porosity after the sintering process. The porous substrate was covered with polyHEMA hydrogel by in situ polymerization. Morphological analysis (SEM) showed that a hydrogel layer formed in the porous solid top surface was fixed to the substrate by mechanical interlocking because the porous surface was filled by the hydrogel. After hydrogel covering, the resultant devices showed a decrease in the compressive elastic modulus that was influenced by the porous substrate material.

Calcium Phosphates↗

Methodology for rheological testing of engineered biomaterials at low audio frequencies.

A commercial rheometer (Bohlin CVO120) was used to mechanically test materials that approximate vocal-fold tissues. Application is to frequencies in the low audio range (20-150 Hz). Because commercial rheometers are not specifically designed for this frequency range, a primary problem is maintaining accuracy up to (and beyond) the mechanical resonance frequency of the rotating shaft assembly. A standard viscoelastic material (NIST SRM 2490) has been used to calibrate the rheometric system for an expanded frequency range. Mathematically predicted response curves are compared to measured response curves, and an error analysis is conducted to determine the accuracy to which the elastic modulus and the shear modulus can be determined in the 20-150-Hz region. Results indicate that the inertia of the rotating assembly and the gap between the plates need to be known (or determined empirically) to a high precision when the measurement frequency exceeds the resonant frequency. In addition, a phase correction is needed to account for the magnetic inertia (inductance) of the drag cup motor. Uncorrected, the measured phase can go below the theoretical limit of -pi. This can produce large errors in the viscous modulus near and above the resonance frequency. With appropriate inertia and phase corrections, +/- 10% accuracy can be obtained up to twice the resonance frequency.

Ear, Middle↗

Production and characterization of polymer nanocomposites with highly aligned single-walled carbon nanotubes.

We report the production and characterization of polymer nanocomposites with single-walled carbon nanotubes having improved mechanical properties and exceptional nanotube alignment. High-pressure carbon monoxide nanotubes (HiPco) were efficiently distributed in polystyrene (PS) and polyethylene (PE) with a twin-screw compounder. Nanotube concentrations were 1, 5, 10, and 20 wt% in PE composites and 0.7 wt% in PS composites. PE composites were melt-spun into fibers to achieve highly aligned nanotubes. Polarized Raman spectroscopy shows that the degree of alignment increases with decreasing fiber diameter and decreases with increasing nanotube loading. The orientation distribution function of a 1 wt% HiPco/PE composite had a full width at half-maximum of approximately 5 degrees. The elastic modulus increases up to 450% relative to PE fibers for 20 wt% nanotube loading at an intermediate fiber diameter of 100 microns.

Anisotropy↗

Comparison of damage accumulation measures in human cortical bone.

Elastic modulus degradation, strength reduction, and energy dissipation have traditionally been the properties of choice to monitor the damage process in cortical bone. However, these properties only provide limited insight into the damage process given the complex mechanical nature of bone. In the current study, alternative measures of the damage process were investigated for machined human cortical bone specimens loaded under torsion. Seventy-two bone specimens from 6 human femurs were subjected to a series of torsional relaxation cycles in which damage was induced during a single relaxation cycle and the effects of damage on the elastic, yield, viscous, and failure properties were determined from pre- and post-damage relaxation cycles. The results revealed that degradation of all torsion properties exhibited a significant twist magnitude effect. However, the yield stress and strain, the relaxation rate, and the total relaxation exhibited 5-10 fold greater degradation than both strength and modulus, when residual strength tests were conducted at high shear strain rates. For the loading conditions examined in this study, the results indicated that the relaxation and yield properties of cortical bone are more sensitive to shear damage accumulation and better measures of the damage process than either strength or modulus. Further, the results reveal an important interaction between damage and the viscous behavior of bone which provides new insight into the effects of damage on bone mechanical properties.

Adult↗